Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

MOSAiC-Colorado State University Ice Spectrometer

This data set contains atmospheric ice nucleating particle (INP) measurements, using Colorado State University&rsquo;s (CSU) Ice Spectrometer (IS), of filter collections taken at the U.S. DOE ARM AMF2 site onboard the R/V Polarstern P-deck during the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign. Samples were collected from October 27, 2019 to September 24, 2020. A filter sampler was mounted approximately 15 m above ground level on a railing in proximity to (and approximately 3 m below) the Aerosol Observation System (AOS) inlet. Single-use filter units open to the atmosphere were pre-cleaned and pre-loaded with 47-mm diameter Nuclepore polycarbonate (0.2 &micro;m pore-diameter) filters. Filters were typically drawn for a three-day period, with an average volume of air filtered of 87,000 standard liters. Total volumes were calculated through recorded daily flow rates using a mass flow meter (TSI). After collection, filters were stored and transported frozen until analysis using CSU&rsquo;s IS instrument (McCluskey et al., 2018). Aerosol particles were first re-suspended in 8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and corresponding 11-fold dilutions, were dispensed into polymerase chain reaction (PCR) trays and placed into the aluminum blocks of the IS. Samples were cooled at approximately 0.33 &deg;C min -1 and freezing detected optically with corresponding temperatures recorded. Cumulative INP concentrations were determined through calculating the number of INPs per mL of suspension (Vali, 1971) and converting to concentration per standard L of air by accounting for the proportion of liquid used and volume of air collected. All samples were corrected for the number of INPs on the average of four field blanks (cleaned, handled, transported, and analyzed in the same way without air flow). Two-tailed, 95% confidence intervals for binomial sampling are provided (Agresti and Coull, 1998). Select samples were also heat treated (95 &deg;C for 20 min) to denature and deactivate biological INPs present and digested in 10% H 2 O 2 at 95 &deg;C under UV-B for 20 min to remove any organic carbon INPs. Agresti, A, and BA Coull. 1998. "Approximate is better than &ldquo;exact&rdquo; for interval estimation of binomial proportions." American Statistics 52: 119&ndash;126. https://doi.org/10.2307/2685469 McCluskey, CS, J Ovadnevaite, M Rinaldi, J Atkinson, F Belosi, D Ceburnis, &hellip; and PJ DeMott. 2018. "Marine and Terrestrial Organic Ice-Nucleating Particles in Pristine Marine to Continentally Influenced Northeast Atlantic Air Masses." Journal of Geophysical Research: Atmospheres 123 (11): 6196&ndash;6212, https://doi.org/10.1029/2017JD028033 Vali, G. 1971. "Quantitative Evaluation of Experimental Results and the Heterogeneous Freezing Nucleation of Supercooled Liquids." Journal of the Atmospheric Sciences 28: 402-209. https://doi.org/10.1175/1520-0469(1971)028<0402:QEOERA>2.0.CO;2

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra↗

$\beta $ Decays of $^{92}$Rb, $^{96\mathrm {gs}}$Y, and $^{142}$Cs Measured with the Modular Total Absorption Spectrometer and the Influence of $\gamma $ Multiplicity on Total Absorption Spectrometry Measurements

Total absorption spectroscopy is a technique that helps obtain reliable β-feeding patterns of complex decays important for nuclear structure and astrophysics modeling as well as decay heat analysis in nuclear reactors. The need for improved measurements of β-feeding patterns from fission decay products has come to the forefront of experiments that use nuclear reactors as a source of antineutrinos. Furthermore we present more detailed results, in particular the β-decay measurements of 96gs Y, and demonstrate the impact of the β-delayed γ multiplicity on the overall efficiency of Modular Total Absorption Spectrometer used at Oak Ridge National Laboratory to study the decays of fission products abundant during a nuclear fuel cycle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A High-Magnetic-Field Polarized 3He Target for Jefferson Lab’s CLAS12 Spectrometer

We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.

Maxwell, James↗

High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the DT neutron spectrum from cryogenically layered Inertial Confinement Fusion (ICF) implosions. Yield, areal density, apparent ion temperature and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ~200 keV FWHM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear electronic field time-of-flight ion mass spectrometers

Time-of-flight mass spectrometer comprising a first drift region and a second drift region enclosed within an evacuation chamber; a means of introducing an analyte of interest into the first drift region; a pulsed ionization source which produces molecular ions from said analyte of interest; a first foil positioned between the first drift region and the second drift region, which dissociates said molecular ions into constituent atomic ions and emits secondary electrons; an electrode which produces secondary electrons upon contact with a constituent atomic ion in second drift region; a stop detector comprising a first ion detection region and a second ion detection region; and a timing means connected to the pulsed ionization source, to the first ion detection region, and to the second ion detection region.

Funsten, Herbert O↗

In-situ droplet monitoring for self-tuning spectrometers

A laser scattering based imaging technique is utilized in order to visualize the aerosol droplets in an inductively coupled plasma (ICP) torch from an aerosol source to the site of analytical measurements. The resulting snapshots provide key information about the spatial distribution of the aerosol introduced by direct and indirect injection devices: 1) a direct injection high efficiency nebulizer (DIHEN); 2) a large-bore DIHEN (LB-DIHEN); and 3) a PFA microflow nebulizer with a PFA Scott-type spray chamber. Moreover, particle image velocimetry (PIV) is used to study the in-situ behavior of the aerosol before interaction with, for example, plasma, while the individual surviving droplets are explored by particle tracking velocimetry (PTV). Further, the velocity distribution of the surviving droplets demonstrates the importance of the initial droplet velocities in complete desolvation of the aerosol for optimum analytical performance in ICP spectrometries. These new observations are important in the design of the next-generation direct injection devices for lower sample consumption, higher sensitivity, lower noise levels, suppressed matrix effects, and for developing smart spectrometers. For example, a controller can be provided to control the output of the aerosol source by controlling the configuration of the source or the gas flow rate via feedback information concerning the aerosol.

Montaser, Akbar↗