Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

ASSESSING MATERIAL DEGRADATION EFFECTS ON LONG TERM STORAGE STRUCTURAL ANALYSES

PNNL staff are currently working to conduct analyses, integrate experimental data, and develop the technical basis for extended long term storage and subsequent transportation of used nuclear fuel. Analyses will serve to augment the experimental work by addressing degradation phenomena not readily obtainable through experimentation, such as low temperature creep over very long periods of time. Analyses can also address issues such as concrete degradation that may not require a comprehensive R&D program to resolve, as well as evaluation of engineering design solutions that can be implemented to mitigate the amount and extent of experimental data needed. Most importantly, analyses are necessary to determine how much degradation any structure, system, or component can experience and still maintain its ability to meet its safety functions. This paper focuses on various structural modeling issues that are affected by material degradation in extended long term storage scenarios. Typical storage cask and transportation package designs have a safety basis that includes a number of structural static or dynamic finite element analysis (FEA) models. Some of the features of these standard models need to be reconsidered when the fuel is in an extended long term storage state. In this paper, a number of standard safety basis FEA models are discussed and evaluated for their applicability to long term storage scenarios. A vertical handling drop analysis is used to illustrate a case where additional modeling is needed to define the loads and loading history needed to properly evaluate material degradation in long term storage scenarios.

Klymyshyn, Nicholas A.↗

Multi factor Assessment for Decarbonization via Technically Viable Carbon Storage

Final poster presenting research under EDX4CCS portfolio, Task 21, on multi-factor assessment for technically viable carbon storage. To date, carbon storage viability assessments have focused on the technically recoverable storage resources to estimate the volume of carbon storage in reservoirs targeted for geologic carbon sequestration. The Carbon Storage Technical Viability Approach (CS TVA) was developed to account for all factors determining the viability of carbon storage at a given site, including socioeconomic and environmental aspects in addition to the classic subsurface geologic assessment. Abstract accepted to the American Geophysical Union Fall Meeting 2023.

Mark-Moser, Mackenzie K.↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Modeling the Cost of Onshore CO2 Pipeline Transport and Onshore CO2 Saline Storage

This paper describes the FECM/NETL CO2 Transport Cost Model (CO2_T_COM), a technoeconomic model of CO2 transport by pipeline, and the FECM/NETL CO2 Saline Storage Cost Model (CO2_S_COM), a technoeconomic model of storage of CO2 in a deep, subsurface saline formation. The results of applying CO2_T_COM to calculate break-even CO2 prices to transport CO2 at different mass flow rates and different distances are presented. Similarly, CO2_S_COM is used to calculate the break-even CO2 price for storing CO2 in 314 potential storage formations across the US. These break-even prices are used to construct cost-supply curves for CO2 storage which are presented on a national and regional basis. CO2_T_COM and CO2_S_COM are the most comprehensive open source technoeconomic models available for analyzing CO2 pipeline transport and CO2 saline storage. To be presented at the SPE?AAPG/SEG Carbon Capture Utilization and Storage Conference in Houston, TX, March 11-13, 2024.

Morgan, David↗

Systems, methods, and devices for failure detection of one or more energy storage devices

An energy storage device management system can include a management portion for charging/discharging an energy storage device and an ultrasound interrogation portion for passing ultrasound energy through the energy storage device during charge/discharge cycles. A memory stores a stream of capture data instances derived from ultrasound energy exiting the energy storage device and baseline ultrasound data instances corresponding with the energy storage device during normal charging/discharging thereof. A processor can compare each capture data instance with the baseline ultrasound data and detect abnormal operating states of the energy storage device. A warning system can issue a notification when abnormal operating states are detected.

Kowalski, Jeffrey A.↗

Considerations for Thermal Annealing of Zr-Alloy Cladding During Dry Storage

In January 2025, the U.S. Department of Energy (DOE) sponsored a technical workshop with fuel vendors that provided a forum for increased collaboration on backend fuel cycle research. The workshop reviewed observations of thermal annealing of irradiated zirconium alloys in simulated dry storage conditions and discussed implications to the industry’s interest in reducing wet storage to optimize operational flexibility and the expected trend of increasing discharge burnup (and decay heats), which could lead to an increase in dry storage temperatures. One approach to accommodate increased decay heats in dry storage is to increase the regulatory temperature limit during dry storage, which is now 400°C. However, this could lead to thermal annealing of the cladding, which will tend to increase creep rates, creep strains, and ductility while decreasing yield strength. These considerations are compounded by bonding between the pellet and cladding at high burnup, which results in the pellet carrying more load during fuel rod deformations, especially in bending, which is the dominant deformation phenomenon in canister drop analyses. Because the U.S. Nuclear Regulatory Commission (NRC) recommends yield strength as a primary failure criterion for accident analyses in storage and transportation, particularly for canister drop scenarios, the purpose of the workshop was to develop options for alternative failure criterion that could replace yield strength in canister drop analyses. Topics discussed were (1) the regulatory framework, (2) the effect of thermal annealing on microhardness and tensile properties of cladding materials, (3) the effect of thermal annealing on fuel rod failure during bending, bending fatigue, and pinch loading, and (4) an alternative failure criterion for canister drop analyses. This paper provides a summary of the key discussions and outcomes of the workshop

Cantonwine, Paul [ORNL] (ORCID:0009000522247033)↗

Performance of an Isobaric Hybrid Compressed Air Energy Storage System at Minimum Entropy Generation

Efficient, large-scale, and cost-effective energy storage systems provide a means of managing the inherent intermittency of renewable energy sources and drastically increasing their utilization. Compressed air energy storage (CAES) and its derivative architectures have received much attention as a viable solution; however, optimization objectives for these systems have not been thoroughly investigated in the literature. In this work, a hybrid thermal and compressed air energy storage (HT-CAES) system is investigated that mitigates the shortcomings of the otherwise attractive conventional CAES systems and its derivatives—shortcomings such as strict geological locations, low energy densities, and the production of greenhouse gas emissions. The HT-CAES system allows a portion of the available energy to operate a compressor and the remainder to be converted and stored in the form of heat through joule/resistive heating in a high-temperature, sensible, thermal energy storage medium. Internally reversible and irreversible HT-CAES system assumptions were investigated, in addition to regenerative and non-regenerative design configurations. Several system optimization criteria were examined—including maximum energy efficiency, maximum exergy efficiency, maximum work output, and minimum entropy generation—with a focus on whether the latter may lead to conclusive design guidelines in a real system. It is shown that an HT-CAES system designed based on a minimum entropy generation objective may operate at a lower energy and exergy efficiency as well as lower output power than otherwise achievable. Furthermore, optimization objective equivalence is shown to be limited to certain design conditions.

25 ENERGY STORAGE↗

Evaluation of a high-moisture stabilization strategy for harvested microalgae blended with herbaceous biomass: Part I—Storage performance

Here, algal biomass is becoming increasingly attractive as a feedstock for biofuel production. However, the swing in algal biomass production between summer and winter months poses a challenge for delivering predictable, constant feedstock supply to a conversion facility. Drying is one approach for stabilizing algal biomass produced in excess during high productivity summer months for utilization during low productivity months, yet drying is energy intensive and thus costly. Wet, anaerobic storage, or ensiling, is a low-cost approach that is commonly used to preserve high moisture herbaceous feedstock. The potential for microalgae stabilization without the need for drying was investigated in this study by simulating ensiling, in which oxygen limitation drives anaerobic fermentation of soluble sugars to organic acids, dropping the pH and thereby stabilizing the material. Algal biomass, Scenedesmus obliquus , was blended with corn stover and stored in acidic, anaerobic conditions at 60% moisture (wet basis) to simulate wet storage by means of ensiling. Results demonstrate that algae and corn stover blends were successfully preserved in anaerobic, acidic conditions for 30 days with < 2% dry matter loss occurring during storage compared to 21% loss in aerobic, non-acidified conditions. Likewise, Scenedesmus obliquus stored alone at 80% moisture (wet basis) in acidified, anaerobic conditions for 30 days, resulted in dry matter losses of 6–14%, compared to 44% loss in neutral pH, anaerobic storage and 37% loss in a neutral pH, aerobically stored condition. Additional experiments were performed at a larger scale in which an algae and corn stover blend was subject to mechanical oxygen exclusion and a Lactobacillus acidophilus inoculum, resulting in 8% loss over 35 days and further indicating that acidic, anaerobic conditions can stabilize microalgae biomass. In summary, the stabilization of harvested algae can be achieved through anaerobic storage, securing a feedstock that is labile yet of high value.

09 BIOMASS FUELS↗

Modeling of thermal storage systems in MILP distributed energy resource models

Thermal energy storage (TES) and distributed generation technologies, such as combined heat and power (CHP) or photovoltaics (PV), can be used to reduce energy costs and decrease CO 2 emissions from buildings by shifting energy consumption to times with less emissions and/or lower energy prices. To determine the feasibility of investing in TES in combination with other distributed energy resources (DER), mixed integer linear programming (MILP) can be used. Such a MILP model is the well-established Distributed Energy Resources Customer Adoption Model (DER-CAM); however, it currently uses only a simplified TES model to guarantee linearity and short run-times. Loss calculations are based only on the energy contained in the storage. This paper presents a new DER-CAM TES model that allows improved tracking of losses based on ambient and storage temperatures, and compares results with the previous version. A multi-layer TES model is introduced that retains linearity and avoids creating an endogenous optimization problem. The improved model increases the accuracy of the estimated storage losses and enables use of heat pumps for low temperature storage charging. Ultimately,results indicate that the previous model overestimates the attractiveness of TES investments for cases without possibility to invest in heat pumps and underestimates it for some locations when heat pumps are allowed. Despite a variation in optimal technology selection between the two models, the objective function value stays quite stable, illustrating the complexity of optimal DER sizing problems in buildings and microgrids.

25 ENERGY STORAGE↗

Model-based optimal design of active cool thermal energy storage for maximal life-cycle cost saving from demand management in commercial buildings

This article provides a method in comprehensive evaluation of cost-saving potential of active cool thermal energy storage (CTES) integrated with HVAC system for demand management in non-residential building. The active storage is beneficial by shifting peak demand for peak load management (PLM) as well as providing longer duration and larger capacity of demand response (DR). In this research, a model-based optimal design method using genetic algorithm is developed to optimize the capacity of active CTES aiming for maximizing the life-cycle cost saving concerning capital cost associated with storage capacity as well as incentives from both fast DR and PLM. In the method, the active CTES operates under a fast DR control strategy during DR events while under the storage-priority operation mode to shift peak demand during normal days. The optimal storage capacities, maximum annual net cost saving and corresponding power reduction set-points during DR event are obtained by using the proposed optimal design method. Lastly, this research provides guidance in comprehensive evaluation of cost-saving potential of CTES integrated with HVAC system for building demand management including both fast DR and PLM.

25 ENERGY STORAGE↗

Cryogenic energy storage: Standalone design, rigorous optimization and techno-economic analysis

Energy storage allows flexible use and management of excess electricity and intermittently available renewable energy. Cryogenic energy storage (CES) is a promising storage alternative with a high technology readiness level and maturity, but the round-trip efficiency is often moderate and the Levelized Cost of Storage (LCOS) remains high. The complex flowsheets with intricate thermodynamics at cryogenic temperatures as well as the presence of multiple loops and refrigeration cycles pose considerable challenges for rigorous model-based design and optimization of CES systems. We present an optimization strategy that couples rigorous process simulation and Bayesian optimization with flowsheet decomposition and identification of hidden coupling constraints to optimally design standalone CES systems. Further refinement is done via a local search using the limited-memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Here our results indicate that it is possible to achieve more than 52% round-trip efficiency and an LCOS of $153/MWh for a standalone 100 MW/400 MWh CES system limited to short-term storage with daily charging–discharging. However, a detailed techno-economic assessment reveals that the LCOS considering total capital investment may exceed $267/MWh when all direct and indirect costs of installation and operation are considered.

25 ENERGY STORAGE↗

Hybrid-energy approach enabled by heat storage and oxy-combustion to generate electricity with near-zero or negative CO 2 emissions

We assess a hybrid-energy approach that modifies a steam-turbine power plant to use renewable energy sources (electricity, plus options for geothermal and solar heat), plus fossil fuel (natural gas and coal) and/or waste biomass (e.g., Douglas fir woodchips). Heat storage allows heat to be created during periods of excess energy supply and for that heat to be converted to electricity when demanded. Excess electricity, such as from variable renewable energy (VRE), is used to generate oxygen for oxy-combustion furnaces that create very-hot, high-purity CO 2 that heats granular rock beds in insulated vessels. Cool CO 2 leaving the beds is dried, sent to compressors powered by excess VRE electricity, before being sent by pipeline to geologic CO 2 storage. Very-hot CO 2 transfers high-grade heat from storage to the power plant in a closed loop that returns medium-grade heat back to storage, allowing low- and medium-grade renewable-heat sources to be stacked beneath combustion heat, with all heat sources being converted to electricity at the same (high) thermal efficiency. Reliable, on-demand power may be generated with near-zero CO 2 emissions with fossil fuel and with negative CO 2 emissions with waste biomass. Our analyses show that with fossil fuel, up to 35% of gross power can be derived from renewable sources, while for waste biomass, it can be entirely derived from renewable sources. Because our approach has the potential to ensure that grids have a continuous supply of clean energy and because electricity is only generated once, when demanded, it could serve as an efficient alternative to bulk energy storage.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Near-isothermal-isobaric compressed gas energy storage

In this paper, the effectiveness of storing energy by compressing and expanding a condensable gas is evaluated. A high efficiency energy storage system, which stores energy by compressing/expanding gas (air) using a liquid (water) piston has been recently introduced and extensively studied. With the use of the liquid piston, the inefficient gas turbomachines used in conventional gas compression/expansion systems are replaced with high efficiency hydraulic machines. Utilizing heat transfer techniques and replacing the non-condensable air with a condensable gas (i.e. CO 2 , synthetic refrigerants, hydrocarbon refrigerants, etc.) have been proposed as methods to improve energy density and roundtrip efficiency of such systems, leading to near isothermal and near isobaric charge/discharge processes. In order to investigate the effectiveness of the proposed concept, a miniature lab-scale experimental setup was designed and built to investigate the compression/expansion characteristics and energy storage efficiency of a system utilizing R134a as the energy storage (primary) working fluid, and mineral refrigerant oil as the liquid piston (secondary) working fluid. Several tests are carried out to quantify energy storage efficiency and energy density. It is found that improving heat transfer rates from/into the storage fluid results in increased efficiency and energy density. A heat-transfer enhancement strategy to achieve near isothermal, isobaric expansion and compression is proposed and investigated experimentally. Some results are generalized and presented in non-dimensional form which can be applied to describe and/or design scaled-up systems. Lastly, a potential working fluid for a scaled-up system is discussed.

25 ENERGY STORAGE↗

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Re-additization of commercial biodiesel blends during long-term storage

Commercial biodiesel blends were aged at 43 degrees C while monitoring stability. The oxidation stability -- or oxidation reserve expressed as Rancimat induction period (IP) -- gradually decreased from its initial value. At a predetermined IP threshold, an antioxidant was used to restore IP to the ASTM D7467 specification minimum of 6 h, referred to as re-additization. At lower IP values, the amount of antioxidant required increased significantly, and the effectiveness tended to be reduced. Once IP fell to essentially zero, the acid content increased to above the allowable limit and insoluble material was also detected. Storage life was increased relative to the as-received fuels as evidenced by longer time to produce acids. Experience in the field may vary based on storage conditions; however, these results indicate re-additization can significantly increase storage life of biodiesel blends when used with regular monitoring of IP and acid number. An assessment of the storage stability of the as-received fuels showed that the initial IP did not predict storage behavior, although fuels above the specification minimum remained stable for >12 weeks accelerated aging (1 year simulated).

25 ENERGY STORAGE↗