Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEALING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Surface sealing of electron beam physical vapor deposited thermal barrier coatings by high-intensity pulsed ion beam

A surface sealing technology by employing high-intensity pulsed ion beam (HIPIB) technique is developed for electron beam physical vapor deposited (EB-PVD) thermal barrier coatings (TBCs) to further improve the high temperature performance. The HIPIB irradiation can deliver a high-density energy up to 100 J/cm{sup 2} into the shallow ion range of about 0.1-10 {mu}m within a short pulse width of less than 1 {mu}s, by which a micrometer-thick bridging layer was achieved on the gap between columnar grains of EB-PVD TBCs under a single pulse of 4.5 J/cm{sup 2}. The thin bridging layer provided atmosphere shielding for the TBCs along with matching strain tolerance of the columnar top coat during thermal cycling. Cyclic oxidation tests at 1050 deg. C demonstrated that weight gain of the sealed TBC samples is decreased by about 60% from 0.8 mg/cm{sup 2} of the as-deposited ones.

36 MATERIALS SCIENCE↗

Structural and Functional Analysis of Surface Proteins from an A(H3N8) Influenza Virus Isolated from New England Harbor Seals

In late 2011, an A(H3N8) influenza virus infection resulted in the deaths of 162 New England harbor seals. Virus sequence analysis and virus receptor binding studies highlighted potential markers responsible for mammalian adaptation and a mixed receptor binding preference. Here, we present a detailed structural and biochemical analysis of the surface antigens of the virus. Results obtained with recombinant proteins for both the hemagglutinin and neuraminidase indicate a true avian receptor binding preference. Although the detection of this virus in new species highlights an increased potential for cross-species transmission, our results indicate that the A(H3N8) virus currently poses a low risk to humans. Cross-species transmission of zoonotic influenza viruses increases public health concerns. Here, we report a molecular and structural study of the major surface proteins from an A(H3N8) influenza virus isolated from New England harbor seals. Furthermore, the results improve our understanding of these viruses as they evolve and provide important information to aid ongoing risk assessment analyses as these zoonotic influenza viruses continue to circulate and adapt to new hosts.

59 BASIC BIOLOGICAL SCIENCES↗

Case Studies of Duct Retrofits and Guidelines for Attic and Crawl Space Duct Sealing

The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $\$$0.92/ft 2 to $\$$1.80/ft 2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Alpha Radiation Damage to the O-Ring Seal of the SAVY-4000 Container

In this memo, the dose to an O-ring from the alpha decay of 238 PuO 2 is calculated. These calculations were made in order to assess possible radiation damage to the O-ring, which could lead to failure and loss of integrity of the seal created by the O-ring. The O-ring being discussed here provides the seal between the lid and bottom of a nuclear materials container. The container will be used for the storage and transport of a number of different radioactive materials. The analysis is made using 238 PuO 2 as it would create the greatest damage to the O-ring when considering the materials that may be stored in it. Contamination of the O-ring is not expected to occur. But in the event radioactive material comes in contact with the O-ring, these calculations provide an estimate of the radiation damage.

07 ISOTOPE AND RADIATION SOURCES↗

Radiological Characterization Technical Report on Californium-252 Sealed Source Transuranic Debris Waste for the Off-Site Source Recovery Project at Los Alamos National Laboratory

This document describes the development and approach for the radiological characterization of Cf-252 sealed sources for shipment to the Waste Isolation Pilot Plant. The report combines information on the nuclear material content of each individual source (mass or activity and date of manufacture) with information and data on the radionuclide distributions within the originating nuclear material. This approach allows for complete and accurate characterization of the waste container without the need to take additional measurements. The radionuclide uncertainties, developed from acceptable knowledge (AK) information regarding the source material, are applied to the summed activities in the drum. The AK information used in the characterization of Cf-252 sealed sources has been qualified by the peer review process, which has been reviewed and accepted by the Environmental Protection Agency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aging of Weapon Seals – An Update on Butyl O-ring Issues

During testing under the Enhanced Surveillance Campaign in 2001, preliminary data detected a previously unknown and potentially serious concern with recently procured butyl o-rings on several programs. All butyl o-rings molded from a proprietary formulation throughout the period circa 1999 through 2001 had less than a full cure. Engineering judgment was that under curing is detrimental and could possibly lead to sub-optimum performance or, in the worst case, premature seal failure. An aging study was undertaken to ensure that suspect o-rings installed in the stockpile will retain sufficient sealing force for a minimum ten-year service life. A new prediction model developed for this study indicates suspect o-rings do not need to be replaced before the ten-year service life. Long-term testing results are reported on a yearly basis to validate the prediction model. This report documents the aging results for the period September 2002 to January 2011.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Proposed Testing to Assess the Accuracy of Glass-To-Metal Seal Stress Analyses

The material characterization tests conducted on 304L VAR stainless steel and Schott 8061 glass have provided higher fidelity data for calibration of material models used in Glass - To - Metal (GTM) seal analyses. Specifically, a Thermo - Multi - Linear Elastic Plastic (thermo - MLEP) material model has be endefined for S S304L and the Simplified Potential Energy Clock nonlinear viscoelastic model has been calibrated for the S8061 glass. To assess the accuracy of finite element stress analyses of GTM seals, a suite of tests are proposed to provide data for comparison to model predictions.

Chambers, Robert S.↗

Wellbore Seal Repair Using Nanocomposite Materials

Nanocomposite wellbore repair materials have been developed, tested, and modeled through an integrated program of laboratory testing and numerical modeling. Numerous polymer-cement nanocomposites were synthesized as candidate wellbore repair materials using various combinations of base polymers and nanoparticles. Based on tests of bond strength to steel and cement, ductility, stability, flowability, and penetrability in opening of 50 microns and less, we identified Novolac epoxy reinforced with multi-walled carbon nanotubes and/or alumina nanoparticles to be a superior wellbore seal material compared to conventional microfine cements. A system was developed for testing damaged and repaired wellbore specimens comprised of a cement sheath cast on a steel casing. The system allows independent application of confining pressures and casing pressures while gas flow is measured through the specimens along the wellbore axis. Repair with the nanocomposite epoxy base material was successful in dramatically reducing the flow through flaws of various sizes and types, and restoring the specimen comparable to an intact condition. In contrast, repair of damaged specimens with microfine cement was less effective, and the repair degraded with application of stress. Post-test observations confirm the complete penetration and sealing of flaws using the nanocomposite epoxy base material. A number of modeling efforts have supported the material development and testing efforts. We have modeled the steel-repair material interface behavior in detail during slant shear tests, which we used to characterize bond strength of candidate repair materials. A numerical model of the laboratory testing of damaged wellbore specimens was developed. This investigation found that microannulus permeability can satisfactorily be described by a joint model. Finally, a wellbore model has been developed that can be used to evaluate the response of the wellbore system (casing, cement, and microannulus), including the use of either cement or a nanocomposite in the microannulus to represent a repaired system. This wellbore model was successfully coupled with a field-scale model of CO 2 injection, to enable predictions of stress and strains in the wellbore subjected to subsurface changes (i.e. domal uplift) associated with fluid injection.

36 MATERIALS SCIENCE↗

Aluminum Clad Spent Nuclear Fuel Task 3: Sealed and Vented Systems Episodic Breathing and Gas Generation Modeling Plan

This document presents the test plan for Task 3 of the Aluminum Clad Spent Nuclear Fuel Long Term Dry Storage Technical Issues Action Plan, which covers modeling and predictions of the generations of corrosive gases within both sealed and vented, subject to episodic breathing, storage systems. This includes aluminum clad spent nuclear fuel (ASNF) that is currently or may in the future be held in dry storage for an extended period. The overall objectives of the Task 3 modeling plan are to: 1. Comprehensively model the combined effects of episodic breathing in vented storage systems/canisters using INL INTEC CPP-603 facility as an example. Both bulk gas phase radiolysis reactions and aluminum cladding surface gas generation reactions will be included into a 3-dimensional computational fluid dynamics (CFD) model to model and predict long-term evolutions of the temperature and concentrations of corrosive gases within unsealed canisters subjected to episodic breathing. 2. Comprehensively model sealed and inert canister storage system using DOE standard canister as an example. 3. Closely integrate with Task 1 and Task 2 for identification of main gas-generation reactions and kinetics and provide simulation results back to Task 1 and 2 to further refine experimental designs. This test plan lays out the technical activities that will be performed to achieve the test objectives described above. Simulations will be performed using the Idaho National Laboratory super computer Falcon.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Main Injector ILA Lambertson Seal Installation

The Main Injector ILA Lambertson magnet uses an 18 inch tapered flange from EVAC. The flange resembles the flange on drawing MD-331910, Flange Weldment MIR Lambertson. Please note that these flanges are heavy. A PALD, portable automotive lifting device, i.e engine hoist, is required as well as the associated lifting fixture, to install the mating flange. The following are the steps to install the EVAC seal drawing MA331512, T/S Conventional Magnet MIR Lambertson Magnet Aluminum Knife Edge Seal.

43 PARTICLE ACCELERATORS↗

Hydrogen Generation Rates for Tank 50 and Saltstone Related Samples using a Sealed Reactor System

This report documents the results of sealed reactor tests to measure the hydrogen generation rate (HGR) from Tank 50 waste, which may be on the order of 10 -10 (ft 3 /h)/gal. Because the estimated HGR limit of detection (LOD) for an open, continuous flow system is approximately 10 -7 (ft 3 /h)/gal a more sensitive method was needed. By accumulating generated gasses in a sealed system without a continuous purge gas, the resulting concentrations can increase the sensitivity of measurement, which is based on time of heating.

08 HYDROGEN↗

Sealed and Insulated Attic Hygrothermal Performance in New California Homes Using Vapor and Air Permeable Insulation—Field Study and Simulation

This project investigated the thermal and moisture performance of a low-cost approach to sealing and insulating attics using glass fiber insulation. The work included a combination of: (1) field measurements of attic and HVAC system performance in two new, high-performance homes in California’s Central Valley (Fresno), and (2) hygrothermal simulations of attic performance. Each field study attic was continuously monitored at multiple locations for over a year for wood moisture content, air humidity, condensation, temperature, and heat flux, together with on-site weather and solar conditions. The Fresno test home showed periodic condensation and high surface wood moisture content, but no surface mold or degradation upon visual inspection at the end of the test period. The Clovis test home showed less indication of high moisture levels—either from surface condensation or wood moisture content—but did have visible suspected mold growth on the inside of the North sheathing at the end of the field testing. These results show the limitations of current moisture measurement techniques focused on wood moisture content, rather than potential for mold growth. From a thermal/energy perspective the attics were close to indoor conditions thereby realizing the design intent for reducing duct system losses. Simulated site HVAC energy savings for sealed vs. vented attics averaged 18% across California climate regions (8% TDV energy savings). Savings were dominated by heating energy reductions; cooling savings were substantially lower. The moisture issues are investigated in greater detail in the simulations. First, we identified the climate regions and house characteristics that are associated with increased risk of mold growth or wood rot in new CA homes. Climate region was very important in determining risk, as were house features that reduced outside air exchange (e.g., 1-story homes, very tight envelopes, very tight attics, no IAQ fan), along with those that increased flow of moist air from the living space to the attic (e.g., supply ventilation fans, larger ceiling leaks, duct leakage). Second, we investigated several approaches to reduce moisture risks, and the best approach was to use a vapor retarder on the inner face of the fiberglass insulation. Both the field and simulation results indicate that the use of air and vapor permeable insulation can be acceptable from a thermal/energy point of view, but additional measures need to be taken to reduce moisture risks, primarily from mold growth.

42 ENGINEERING↗

Photoluminescence Spectroscopy to Determine Residual Stresses in Glass-to-Metal Seals

In components with two materials, such as glass-to-metal (GtM) seals, residual stress can reduce long-term reliability. Therefore, it is important to be able to accurately measure residual stress within these components. The residual stress can be from a large strain due to the mismatch of thermo-physical response of the two materials or a small strain due to stress and/or structural relaxation. Both modeling and experimental measurements were conducted on multiple GtM seals constructed with CGI 930 glass with purposely added alumina particles. The alumina particles have an established Cr fluorescence pattern and the shift in position of these peaks can accurately measure the strain of the alumina crystals. Photoluminescence spectroscopy (PLS) technique was utilized due to its non-destructive nature and high spatial resolution. PLS scans of these components were analyzed and compared to the models developed previously.

36 MATERIALS SCIENCE↗

Energy Harvesting Remotely Monitored Sealing Array (RMSA) (Field Test Annual Report)

Sandia National Laboratories (SNL) is investigating photovoltaic (PV) cell configurations, integrating them with the battery-operated Remotely Monitored Sealing Array (RMSA), and testing and evaluating performance for enhanced battery life under various lighting conditions at a facility at the Savannah River Site (SRS) or Savannah River National Laboratory (SRNL). Unattended safeguards equipment (e.g. seals) incorporates many low-power electronic circuits, which are often powered by expensive and environmentally toxic lithium batteries. These batteries must periodically be replaced, adding a radiological hazard for both safeguards inspectors and operators. An extended field test of these prototype PV energy harvesting (EH) RMSAs at an operational nuclear facility will give additional data and allow for an analysis of this technology in a variety of realistic conditions, which will be documented in a final report. RMSAs are used for this testing, but SNL envisions energy harvesting technology may be applicable to additional safeguards equipment.

14 SOLAR ENERGY↗

Unreviewed Disposal Question Evaluation: Disposal of the Perma-Fix Environmental Services Macroencapsulated Sealed Sources at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This Unreviewed Disposal Question Evaluation assesses whether the Perma-Fix Environmental Services Macroencapsulated Sealed Sources is suitable for shallow land burial at the Area 5 Radioactive Waste Management Site on the Nevada National Security Site. Disposal of the waste stream meets all performance objectives in DOE M 435.1-1, “Radioactive Waste Management Manual,” Chapter IV, Section P. The Perma-Fix Environmental Services Macroencapsulated Sealed Sources waste stream is recommended for acceptance without conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress Report for the Pathfinder Project: A Laser-Based / Fiber Optic IAEA Seal That Implements Spectral Interferometry

This is the first progress report for the Laser / Fiber-Optic Based IAEA Seal. This seal implements spectral interferometry, which is crucial for its resilience to tampering. Indeed, based on our understanding of telecommunications-based fiber optic technology, it is essentially impossible to tamper with the fiber without detection either immediately (with an active system) or subsequently (with a passive system).

36 MATERIALS SCIENCE↗

Container Evaluation: Analysis of the Swagelok Knuckle with Viewport as an Approved Hermetically Sealed Inner Container

This report outlines the results from the water ingress test, helium leak test and additional atmosphere testing for the Swagelok knuckle with viewport container further referred to as the SKV. This container is constructed from a standard union vacuum fitting, 1.33” conflat to 0.5” male VCR, a 1.33” conflat fused silica lensed viewport fitting, and a 0.5 inch VCR cap. The primary intended use of this container is to store Pu metal samples in the vault for a time interval exceeding 40 years. The samples need to be contained in an air free environment to ensure that the material does not oxidize over time. The container viewport is a critical design feature that will help the operators visually inspect and evaluate the state of the metal samples prior to opening the container. These containers are advertised as leak tight, but experimental tests were performed to test the water resistant criteria and the gas leaking criteria set forth by the TA-55 Criticality Safety Program. The results of the water ingress test show that the container is water-tight, with no signs of water penetrating the container within the required guidelines outlined in TA55-AP-522. The preliminary He leak test performed demonstrate that the conflat window port and VCR cap are able to maintain a hermetic seal. Additionally, all containers will be He leak tested independently by the manufacturer prior to shipping to LANL. A third voluntary test was added to assess the container’s ability to hold atmosphere, with successful results indicating the container is able to hold inert atmosphere to prevent lanthanum metal oxidation. It is the conclusion of the authorsthat there is enough evidence through the test conducted and outlined within this document that the proposed container meets the definition of a water-tight container, and it is able to provide a hermetic seal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗