Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

First plasma processing trial of a quarter-wave resonator cryomodule at the Facility for Rare Isotope Beams

Studies of plasma processing for reduction of field emission in quarter-wave resonator (QWR) cryomodules are underway at the Facility for Rare Isotope Beams (FRIB), where a total of 104 QWRs are presently in operation. Driving the plasma with a higher-order mode allows for less mismatch at the fundamental power coupler and higher plasma density. The first plasma processing trial for FRIB QWRs in a cryomodule was conducted in January 2024. In-bunker cold tests of the cryomodule showed a significant reduction in field emission x-rays after plasma processing.

Glow & corona plasma discharges↗

Hamiltonian parameter inference from resonant inelastic x-ray scattering with active learning

Identifying model Hamiltonians is a vital step toward creating predictive models of materials. Here, in this study, we combine Bayesian optimization with the EDRIXS numerical package to infer Hamiltonian parameters from resonant inelastic x-ray scattering (RIXS) spectra within the single atom approximation. To evaluate the efficacy of our method, we test it on experimental RIXS spectra of NiPS 3 , NiCl 2 , Ca 3 ⁢LiOsO 6 , and Fe 2⁢ O 3 , and demonstrate that it can reproduce results obtained from hand-fitted parameters to a precision similar to expert human analysis while providing a more systematic mapping of parameter space. Our work provides a key first step toward solving the inverse scattering problem to extract effective multi-orbital models from information-dense RIXS measurements, which can be applied to a host of quantum materials. We also propose atomic model parameter sets for two materials, Ca 3⁢ LiOsO 6 and Fe 2⁢ O 3 , that were previously missing from the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IRIXS: a resonant inelastic X-ray scattering instrument dedicated to X-rays in the intermediate energy range

A new resonant inelastic X-ray scattering (RIXS) instrument has been constructed at beamline P01 of the PETRA III synchrotron. This instrument has been named IRIXS (intermediate X-ray energy RIXS) and is dedicated to X-rays in the tender-energy regime (2.5–3.5 keV). The range covers the L 2,3 absorption edges of many of the 4delements (Mo, Tc, Ru, Rh, Pd and Ag), offering a unique opportunity to study their low-energy magnetic and charge excitations. The IRIXS instrument is currently operating at the Ru L 3 -edge (2840 eV) but can be extended to the other 4d elements using the existing concept. The incoming photons are monochromated with a four-bounce Si(111) monochromator, while the energy analysis of the outgoing photons is performed by a diced spherical crystal analyzer featuring (10$\bar{2}$ lattice planes of quartz (SiO 2 ). A total resolution of 100 meV (full width at half-maximum) has been achieved at the Ru L 3 -edge, a number that is in excellent agreement with ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant inelastic X-ray scattering endstation at the 1C beamline of Pohang Light Source II

An endstation for resonant inelastic X-ray scattering (RIXS), dedicated to operations in the hard X-ray regime, has been constructed at the 1C beamline of Pohang Light Source II. At the Ir L 3 -edge, a total energy resolution of 34.2 meV was achieved, close to the theoretical estimation of 34.0 meV, which considers factors such as the incident energy bandpass, intrinsic analyzer resolution, geometrical broadening of the spectrometer, finite beam-size effect and Johann aberration. The performance of the RIXS instrument is demonstrated by measuring the RIXS spectra of Sr 2 IrO 4 . The endstation can be easily reconfigured to measure energy-integrated intensities with very low background for diffuse scattering and diffraction experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers

A major challenge in soft X-ray spectroscopy is the efficient collection of the emitted X-rays by grazing-incidence mirrors. In this energy range, grazing-incidence mirrors are widely used as optics for the collection of light. The small angle of incidence necessarily limits the collection solid angle of soft X-ray spectrometers. We present a new mirror surface, a sagittal collimating diaboloid, that can both collect and focus light from a point source in an aberration-free manner. The usefulness of this optic in increasing throughput is demonstrated with a realistic example design of a moderate-sized (3 m) medium-resolution resonant inelastic X-ray scattering spectrometer.

36 MATERIALS SCIENCE↗

Nuclear Quadrupole Resonance for Substance Detection

This review paper provides a comprehensive overview of recent advances in nuclear quadrupole resonance (NQR) spectroscopy for substance detection, highlighting its principles, methodologies, and applications. The paper elucidates the fundamental physics underlying NQR spectroscopy, emphasizing the interaction between nuclear quadrupole moments and electric field gradients. It explores the various experimental techniques and instrumentation developments that have enabled the sensitive detection and precise characterization of substances containing quadrupolar nuclei. A significant portion of the survey is dedicated to discussing the diverse applications of NQR spectroscopy, including the detection of explosives, drug pharmaceuticals, and material authentication. Furthermore, the survey examines the challenges and limitations associated with NQR spectroscopy, including issues related to signal-to-noise ratio (SNR), temperature dependency, and substance restrictions. Strategies to overcome these challenges are discussed, offering insights into the future directions of NQR spectroscopy research that includes artificial intelligence (AI), internet of things (IoT) integration, incorporating a cloud database for NQR parameter storage, and multi-modal analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Single-Stage Isolated Resonant SiC DC/AC Inverter for Efficient High-Power Applications

This paper presents a single-stage series-resonant dual active half bridge (SR-DAHB) inverter suitable for high power applications. The topology is an isolated dual half-bridge circuit with an unfolding bridge. A combined phase-shift and frequency modulation technique is utilized to generate AC power output. In high-power applications where the switching devices operate at relatively high current and voltage, the switching loss becomes the major portion of the converter’s total loss as the devices are turned on and off under hard switching condition. The primary merit of the proposed single-stage SR-DAHB inverter with the combined phase-shift and frequency modulation control is to significantly reduce the switching loss so that it is not a function of load current. A precise and comprehensive power loss model is developed for both the SR-DAHB and DAHB to optimize the operation of the inverters. The objective of the optimization is to minimize the inverter total loss while calculating the optimum combination of frequency and phase shift. A 1.5 kV, 50 kW prototype was built to demonstrate the performance of the SRDAHB versus DAHB inverters with the combined phase-shift and frequency modulation control, and validate the theoretical analysis.

Tayebi, S. Milad↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

Thermal Analysis of a Polypropylene Capacitor for Resonant Tuning Networks in WPT Applications

This study presents the thermal analysis of polypropylene capacitors operating at high frequencies and high currents used in the resonant tuning networks for electric vehicle (EV) wireless charging systems. The thermal analysis and performance results of the CELEM polypropylene capacitors are presented at different currents for a polyphase wireless power transfer (WPT) system while the study can be expanded to other capacitors by different manufacturers. Thermal equivalent circuit of the capacitor is derived and required cold plate size and design calculations are conducted by modeling the polypropene capacitor in MATLAB. The polypropene capacitor's finite element analysis (FEA) model is developed using COMSOL Multiphysics simulation software, and the thermal characteristics and analysis of the capacitor are presented in this paper.

Aktas, Ahmet↗

A New Design Consideration for Bidirectional Resonant Converters

This paper introduces innovative design considerations for a bidirectional resonant converter, optimized for Electric Vehicle (EV) charging and vehicle-togrid (V2G) applications. By eliminating the need for complex voltage or current gain functions, the proposed design greatly simplifies the development process, making it more accessible for manufacturers and system integrators. This approach not only reduces engineering time and resource investment but also accelerates time-to-market, giving stakeholders a competitive edge in rapidly expanding EV infrastructure markets. In addition, the streamlined design ensures soft switching at maximum output power, leading to higher efficiency and improved durability, which translates to lower operating costs and a longer service life for EV charging equipment. These benefits provide a clear pathway to more cost-effective, scalable, and sustainable EV charging and V2G solutions, enhancing value for stakeholders by facilitating smoother integration into the grid and supporting energy resilience. To validate the benefits, a 60 kW bidirectional charger with a flexible input range of 700−900VDC and an output range of 400−1250VDC was developed, underscoring the design's adaptability and potential for large-scale implementation.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Static Strain Modelling, Calibration, and Measurements for High-Temperature Wireless SAW Resonator Operation

Static strain measurements are relevant for Integrated System Health Monitoring of civil structures, aircrafts, power plants and advanced manufacturing equipment, with implications for safety, process efficiency, and maintenance costs. Wireless strain sensing is highly desirable where the presence of wires poses significant safety concerns, increases maintenance, and thus overall costs, or where they are not feasible, such as in applications which contain moving parts. This paper presents wireless interrogation of surface acoustic wave resonators (SAWRs) fabricated on langasite (LGS) along Euler angles (0°, 138.5°, 32.9°) and aimed at the detection of static strain at hightemperature (HT, above 100°C). Both commercial HT strain gauges and finite element analysis (FEA Abaqus software) were used and compared for SAWR strain calibration from room temperature (RT) to HT. In addition, this work investigated a compromise between high temperature operation vs. sensitivity based on the thickness of ceramic adhesive used. For instance, a reduction in the adhesive thickness from about 150 μm to 135 μm, resulted in a 39% increase in sensitivity at RT. It was also observed that the sensitivity dropped up to 34% from RT to 200°C. Furthermore, wireless operation, calibration, and increase in sensitivity constitute important advances in the use of LGS SAW devices to monitor static stress in high-temperature harsh environments.

42 ENGINEERING↗

TRINIDI: Time-of-Flight Resonance Imaging With Neutrons for Isotopic Density Inference

Accurate reconstruction of 2D and 3D isotope densities is a desired capability with great potential impact in applications such as evaluation and development of next-generation nuclear fuels. Neutron time-of-flight (TOF) resonance imaging offers a potential approach by exploiting the characteristic neutron absorption spectra of each isotope. However, it is a major challenge to compute quantitatively accurate images due to a variety of confounding effects such as severe Poisson noise, background scatter, beam non-uniformity, absorption non-linearity, and extended source pulse duration. We present the TRINIDI algorithm which is based on a two-step process in which we first estimate the neutron flux and background counts, and then reconstruct the areal densities of each isotope and pixel. Both components are based on the inversion of a forward model that accounts for the highly non-linear absorption, energy-dependent emission profile, and Poisson noise, while also modeling the substantial spatio-temporal variation of the background and flux. Further, to do this, we formulate the non-linear inverse problem as two optimization problems that are solved in sequence. We demonstrate on both synthetic and measured data that TRINIDI can reconstruct quantitatively accurate 2D views of isotopic areal density that can then be reconstructed into quantitatively accurate 3D volumes of isotopic volumetric density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of High-Power Wireless Charging Systems and Analysis of Polyphase Wireless Charging System Phase Winding and Resonant Tuning Network Connection Configurations

In spite of the high energy efficiency and environmental benefits of electric vehicles (EVs), adoption rates are increasing at a relatively slow pace, primarily because of EVs’ limited range and long charging durations. To reduce EV charging times to be comparable to refueling times of conventional vehicles, extreme fast charging systems are required. Such charging systems would reduce drivers’ range anxiety and enable long-distance interstate travel with EVs. Here, this substantial target in charging rates with 15–20 minutes of recharging times, requires research and development from grid to batteries with advanced charging systems. Wireless power transfer systems for EV charging applications are flexible, convenient, and highly efficient, and they allow automated charging. This paper reviews the power electronics and winding and resonant tuning network configurations for polyphase wireless power transfer systems for high-power wireless charging applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electronic surface reconstruction of TiO 2 nanocrystals revealed by resonant inelastic x-ray scattering

The identification of lattice multiphases in TiO 2 nanocrystals is studied by high resolution transmission electron microscope and electron diffraction patterns. Based on the spectroscopic analysis using soft x-ray absorption and resonant inelastic soft x-ray scattering, it is believed that the oxygen vacancies at the interface exhibit structural distortion of the TiO$^{8-}_6$ cluster around the defect site as for the multiphase lattice. We elucidate that the extra 3d electrons nearby induce the inelastic scattering features with the excitation energy dependence owing to different energy relaxation processes, a characteristic of the electron-phonon coupling or the nature of the electron-hole pair at the intermediate state. The manifold dd excitations driven by the strong interaction between Ti-3d and O-2p electrons are noticeably rich, coexisting on both Ti and O sites. Finally, this sophisticated experiment can advance the perspective of nanocomposite TiO 2 for various interactions of surface Ti 3+ in applications of future devices.

36 MATERIALS SCIENCE↗

Quantifying the resonant photoemission of radiation damaged Pu

Here, the resonant photoelectron spectroscopy (ResPes) of new and aged δ-Pu(Ga) is reassessed by using the small oxygen contaminant peaks as an independent and quantitative check upon conventional cross-photon-energy normalization. Good agreement is found between the measured oxygen intensities and the atomic cross section calculations. Consistent with earlier analyses, the radiation induced damage in the aged samples is found to compress and sharpen the 5f peaks. This is associated with increased localization of the 5f bands, corresponding to the 5f density of states calculations that show a narrowing of 5f bandwidth with cluster size diminishment.

36 MATERIALS SCIENCE↗

Estimation of elastic properties of an additively manufactured lattice using resonant ultrasound spectroscopy

Development of improved approaches in the characterization of additively manufactured structures continues to be a topic of interest for the advanced manufacturing community. This article will investigate an approach using resonant ultrasound spectroscopy (RUS) to determine the effective elastic constants of an orthotropic lattice structure. The evaluation is performed on a cube shaped 316 L stainless steel test specimen, constructed using selective laser melting techniques. The approach uses RUS techniques in conjunction with the assumption that in the frequency regime of interest, the wavelength of the diagnostic ultrasound is greater than the discrete structural features of the unit cell of the lattice; thus, the AM structure can be treated as an anisotropic continuum with effective material properties and symmetry inherited from the unit cell. The RUS analysis estimates the nine elastic coefficients associated with orthotropic sample symmetry, which, in turn, are used to determine the elastic moduli and Poisson ratios. Current results show good agreement between experiments and modeled data. Comparisons to published results are also in good agreement, indicating the potential applicability of this characterization technique for estimating the linear elastic properties of innovative additive manufactured metal lattice structures.