Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reliability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

In Situ ATR-FTIR Study of the Cathode–Electrolyte Interphase: Electrolyte Solution Structure, Transition Metal Redox, and Surface Layer Evolution

We present a study of the lithium nickel manganese cobalt oxide (LiNi 0.6 Mn 0.2 Co 0.2 O 2 , NMC622) cathode-electrolyte interphase (CEI) during galvanostatic charging and discharging using in situ attenuated total reflectance Fourier transform infrared (ATR-FTIR) methods to investigate the voltage dependent electrolyte solution structure changes at the interface, transition metal (TM) redox chemistry, and cathode/electrolyte interfacial layer evolution. Furthermore, our in situ cell design provides both reliable electrochemical device testing and strong FTIR vibrational absorption signals near the cathode surface. Specifically, advanced spectral analysis elucidates changes of near-surface Li+ ion (de)solvation by solvent molecules during galvanostatic cycling. Moreover, cathode metal-oxygen vibrational absorptions, sensitive to TM redox behaviors and subsequent local structural variations, were correlated to cathode de-lithiation (and lithiation) and electrolyte solution structure changes. In addition, we have detected the formation and evolution of a CEI surface layer on the NMC622 cathode that contributes to the cell's capacity fade.

25 ENERGY STORAGE↗

Report on the Use and Function of the Integrated Operations Capability Analysis Platform (ICAP) and the LWRS Innovation Portal (IP)

The commercial nuclear power industry has achieved excellent safety and reliability performance but is struggling to survive in an electricity market that is increasingly dominated by subsidized renewables and cheap natural gas. These challenges have forced utilities to explore previously uncharted avenues to drastically reduce the operations and maintenance costs of their plants which are the primary drivers of the total cost to produce electricity. The petrochemical industry faced similar challenges some years ago as the costs of extraction and processing were rising while their reservoirs were being depleted along with a drop-in commodity prices that resulted in unsustainable operations. In this challenging climate, they developed a business model called Integrated Operations (IO) that sought to utilize technology to enable news ways of working through the integration of people, technology, process and governance changes. The Light Water Reactor Sustainability (LWRS) program, working with IFE have developed an operating model via transferable learnings from the North Sea O&G industry. This framework is termed “Integrated Operations for Nuclear” (ION). ION is a transformation model that integrates the benefits and features of four principal factors: People, Technology, Process and Governance. The purpose of this report is to describe how to generate an ION business process analysis and utilize this information to reduce O&M costs. In order to make this job easier, DOE LWRS has created a suite of tools that will allow a person who is involved in a transformation effort at their company to build a solid documented business case for embarking on a major transformation effort. These tools, the Integrated Operations Capability Analysis Model (ICAP) and the LWRS Innovation Portal (IP) are described herein with instructions on their use. Instructions on how the interface with the EPRI Business Case Analysis Method (BCAM) are also provided.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

2018 Research Highlight in Manufacturing Analysis: Analysis of Supply Chains and Advanced Manufacturing of Small Hydropower Systems

Hydropower in the United States has been a reliable and critical renewable energy generation resource over the last 100 years, and as of 2016, approximately 101 GW of hydropower and pumped hydropower capacity were installed (DOE 2016). As such, strong manufacturing supply chains have been essential. The U.S. hydropower supply chain is distributed across the country with denser concentrations near manufacturing centers, such as the West Coast, Midwest, Great Lakes, and Northeast (Uria-Martinez, O'Connor, and Johnson 2015). The hydropower manufacturing hubs (such as the Northeast and the Great Lakes vicinity), which produce components for all sizes of hydropower generating equipment, can be seen in Figure 1. The major components for hydropower are the gates, valves, generators, penstocks, transformers, and turbines.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimized Generator Designs for the DTU 10-MW Offshore Wind Turbine using GeneratorSE

Compared to land-based applications, offshore wind imposes challenges for the development of next generation wind turbine generator technology. Direct-drive generators are believed to offer high availability, efficiency, and reduced operation and maintenance requirements; however, previous research suggests difficulties in scaling to several megawatts or more in size. The resulting designs are excessively large and/or massive, which are major impediments to transportation logistics, especially for offshore applications. At the same time, geared wind turbines continue to sustain offshore market growth through relatively cheaper and lightweight generators. However, reliability issues associated with mechanical components in a geared system create significant operation and maintenance costs, and these costs make up a large portion of overall system costs offshore. Thus, direct-drive turbines are likely to outnumber their gear-driven counterparts for this market, and there is a need to review the costs or opportunities of building machines with different types of generators and examining their competitiveness at the sizes necessary for the next generation of offshore wind turbines. In this paper, we use GeneratorSE, the National Renewable Energy Laboratory's newly developed systems engineering generator sizing tool to estimate mass, efficiency, and the costs of different generator technologies satisfying the electromagnetic, structural, and basic thermal design requirements for application in a very large-scale offshore wind turbine such as the Technical University of Denmark's (DTU) 10-MW reference wind turbine. For the DTU reference wind turbine, we use the previously mentioned criteria to optimize a direct-drive, radial flux, permanent-magnet synchronous generator; a direct-drive electrically excited synchronous generator; a medium-speed permanent-magnet generator; and a high-speed, doubly-fed induction generator. Preliminary analysis of leveled costs of energy indicate that for large turbines, the cost of permanent magnets and reliability issues associated with brushes in electrically excited machines are the biggest deterrents for building direct-drive systems. The advantage of medium-speed permanent-magnet machines over doubly-fed induction generators is evident, yet, variability in magnet prices and solutions to address reliability issues associated with gearing and brushes can change this outlook. This suggests the need to potentially pursue fundamentally new innovations in generator designs that help avoid high capital costs but still have significant reliability related to performance.

17 WIND ENERGY↗

Structural analysis of molten materials by a remote fiber optic Raman sensor

This study presents a novel in situ high-temperature fiber optic Raman probe that enables the study of the physical properties and structure of molten samples at temperatures up to 1400 °C. To demonstrate the functionality of the high-temperature fiber optic Raman probe, different composition mold fluxes were evaluated in this report. The Raman spectra at flux molten temperature were successfully collected and analyzed. A deconvolution algorithm was employed to identify peaks in the spectra associated with the molecular structure of the components in each sample. Here, the experimental results demonstrate that the composition-dependent Raman signal shift can be detected at high temperatures, indicating that molten materials analysis using a high-temperature Raman system shows significant promise. This flexible and reliable high-temperature Raman measurement method has great potential for various applications, such as materials development, composition and structure monitoring during high-temperature processing, chemical identification, and process monitoring in industrial production.

47 OTHER INSTRUMENTATION↗

Reliable and efficient solution of genome-scale models of Metabolism and macromolecular Expression

Currently, Constraint-Based Reconstruction and Analysis (COBRA) is the only methodology that permits integrated modeling of Metabolism and macromolecular Expression (ME) at genome-scale. Linear optimization computes steady-state flux solutions to ME models, but flux values are spread over many orders of magnitude. Data values also have greatly varying magnitudes. Furthermore, standard double-precision solvers may return inaccurate solutions or report that no solution exists. Exact simplex solvers based on rational arithmetic require a near-optimal warm start to be practical on large problems (current ME models have 70,000 constraints and variables and will grow larger). We also developed a quadrupleprecision version of our linear and nonlinear optimizer MINOS, and a solution procedure (DQQ) involving Double and Quad MINOS that achieves reliability and efficiency for ME models and other challenging problems tested here. DQQ will enable extensive use of large linear and nonlinear models in systems biology and other applications involving multiscale data.

59 BASIC BIOLOGICAL SCIENCES↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

An analysis of Bayesian estimates for missing higher orders in perturbative calculations

With current high precision collider data, the reliable estimation of theoretical uncertainties due to missing higher orders (MHOs) in perturbation theory has become a pressing issue for collider phenomenology. Traditionally, the size of the MHOs is estimated through scale variation, a simple but ad hoc method without probabilistic interpretation. Bayesian approaches provide a compelling alternative to estimate the size of the MHOs, but it is not clear how to interpret the perturbative scales, like the factorisation and renormalisation scales, in a Bayesian framework. Recently, it was proposed that the scales can be incorporated as hidden parameters into a Bayesian model. In this paper, we thoroughly scrutinise Bayesian approaches to MHO estimation and systematically study the performance of different models on an extensive set of high-order calculations. We extend the framework in two significant ways. First, we define a new model that allows for asymmetric probability distributions. Second, we introduce a prescription to incorporate information on perturbative scales without interpreting them as hidden model parameters. We clarify how the two scale prescriptions bias the result towards specific scale choice, and we discuss and compare different Bayesian MHO estimates among themselves and to the traditional scale variation approach. Finally, we provide a practical prescription of how existing perturbative results at the standard scale variation points can be converted to 68%/95% credibility intervals in the Bayesian approach using the new public code MiHO.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Experimental Characterization of a Grid-Loss Event on a 2.5-MW Dynamometer Using Advanced Operational Modal Analysis: Preprint

This paper experimentally investigates a worst case grid loss event conducted on the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) drivetrain mounted on the 2.5MW NREL dynamic nacelle test-rig. The GRC drivetrain has a directly grid-coupled, fixed speed asynchronous generator. The main goal is the assessment of the dynamic content driving this particular assess the dynamic content of the high-speed stage of the GRC gearbox. In addition to external accelerometers, high frequency sampled measurements of strain gauges were used to assess torque fluctuations and bending moments both at the nacelle main shaft and gearbox high-speed shaft (HSS) through the entire duration of the event. Modal analysis was conducted using a polyreference Least Squares Complex Frequency-domain (pLSCF) modal identification estimator. The event driving the torsional resonance was identified. Moreover, the pLSCF estimator identified main drivetrain resonances based on a combination of acceleration and strain measurements. Without external action during the grid-loss event, a mode shape characterized by counter phase rotation of the rotor and generator rotor determined by the drivetrain flexibility and rotor inertias was the main driver of the event. This behavior resulted in significant torque oscillations with large amplitude negative torque periods. Based on tooth strain measurements of the HSS pinion, this work showed that at each zero-crossing, the teeth lost contact and came into contact with the backside flank. In addition, dynamic nontorque loads between the gearbox and generator at the HSS played an important role, as indicated by strain gauge-measurements.

17 WIND ENERGY↗

An Alternative View of the Dynamical Origin of the P11 Nucleon Resonances: Results from the Excited Baryon Analysis Center

We present an alternative interpretation for the dynamical origin of the P{sub 11} nucleon resonances, which results from the dynamical coupled-channels analysis at Excited Baryon Analysis Center of Jefferson Lab. The results indicate the crucial role of the multichannel reaction dynamics in determining the N* spectrum. An understanding of the spectrum and structure of the excited nucleon (N*) states is a fundamental challenge in the hadron physics. The N* states, however, couple strongly to the meson-baryon continuum states and appear only as resonance states in the {gamma}N and {pi}N reactions. One can expect from such strong couplings that the (multichannel) reaction dynamics will affect significantly the N* states and cannot be neglected in extracting the N* parameters from the data and giving physical interpretations. It is thus well recognized nowadays that a comprehensive study of all relevant meson production reactions with {pi}N,{eta}N,{pi}{pi}N,KY, {hor_ellipsis} final states is necessary for a reliable extraction of the N* parameters. To address this challenging issue, the Excited Baryon Analysis Center (EBAC) of Jefferson Lab has been conducting the comprehensive analysis of the world data of {gamma}N,{pi}N {yields} {pi}N,{eta}N,{pi}{pi}N,KY, {hor_ellipsis} reactions systematically, covering the wide energy and kinematic regions. The analysis is pursued with a dynamical coupled-channels (DCC) model, the EBAC-DCC model, within which the unitarity among relevant meson-baryon channels, including the three-body {pi}{pi}N channel, is fully taken into account.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards smart corrective switching: analysis and advancement of PJM's switching solutions

Transmission switching, as a power flow control mechanism that can reduce costs and improve reliability, has gained a lot of attention during the last decade. Despite its benefits, industry adoption has been very limited due to its computational complexity, stability and AC performance concerns. Pennsylvania New Jersey Maryland (PJM) has published a list of corrective switching solutions to relieve actual and post‐contingency network violations. The list is developed based on operators ’ prior knowledge and offline studies. This study employs a fast AC‐based real‐time contingency analysis (RTCA) tool with corrective transmission switching (CTS) functionality to analyse PJM's switching solutions with actual PJM data. The results show that the RTCA CTS tool is almost always able to find solutions that perform better than, or equally as well as, PJM's solutions. The results also show that PJM's list identifies solutions for only 3% of the problematic contingencies with post‐contingency violations over the course of one week. The RTCA CTS tool, however, is able to find corrective TS solutions for almost all the cases. The results suggest that CTS is ripe for industry adoption. The tool provides significant savings and would pave the road towards a smarter transmission network as an essential ingredient of the future smart grid.

Balasubramanian, Pranavamoorthy↗

A review of lunar chronology revealing a preponderance of 4.34-4.37 Ga ages

In this study, data obtained from Sm-Nd and Rb-Sr isotopic measurements of lunar highlands’ samples are renormalized to common standard values and then used to define ages with a common isochron regression algorithm. The reliability of these ages is evaluated using five criteria that include whether: (1) the ages are defined by multiple isotopic systems, (2) the data demonstrate limited scatter outside uncertainty, (3) initial isotopic compositions are consistent with the petrogenesis of the samples, (4) the ages are defined by an isotopic system that is resistant to disturbance by impact metamorphism, and (5) the rare-earth element abundances determined by isotope dilution of bulk of mineral fractions match those measured by in situ analyses. From this analysis, it is apparent that the oldest highlands’ rock ages are some of the least reliable, and that there is little support for crustal ages older than ~4.40 Ga. A model age for ur-KREEP formation calculated using the most reliable Mg-suite Sm-Nd isotopic systematics, in conjunction with Sm-Nd analyses of KREEP basalts, is 4389 ± 45 Ma. This age is a good match to the Lu-Hf model age of 4353 ± 37 Ma determined using a subset of this sample suite, the average model age of 4353 ± 25 Ma determined on mare basalts with the 146 Sm- 142 Nd isotopic system, with a peak in Pb-Pb ages observed in lunar zircons of ~4340 ± 20 Ma, and the oldest terrestrial zircon age of 4374 ± 6 Ma. The preponderance of ages between 4.34 and 4.37 Ga reflect either primordial solidification of a lunar magma ocean or a widespread secondary magmatic event on the lunar nearside. The first scenario is not consistent with the oldest ages reported for lunar zircons, whereas the second scenario does not account for concordance between ages of crustal rocks and mantle reservoirs.

79 ASTRONOMY AND ASTROPHYSICS↗

How Informative Are Drug‐Drug Interactions of Gene‐Drug Interactions?

Abstract FDA recommendations to manage polymorphic CYP‐mediated drug‐drug interactions (DDIs) and gene‐drug interactions (GDIs) are typically similar. However, DDIs may not always reliably predict GDIs because the victim drug may have multiple metabolic pathways and the perpetrator drug may affect multiple enzymes or transporters. Consequently, it is of great interest to both the pharmaceutical industry and regulatory agencies to determine if DDI studies can be leveraged to inform GDIs or vice versa for dose adjustment and labeling. The objective of this study was to investigate under what circumstances DDIs can be used to predict GDIs for prototypical CYP2C9, CYP2C19, and CYP2D6 substrates. We investigated model substrates for CYP2D6 (metoprolol, dextromethorphan, atomoxetine, and vortioxetine), CYP2C9 (warfarin, flurbiprofen, and celecoxib), and CYP2C19 (omeprazole and clopidogrel). Data on drug exposure for poor metabolizers (GDI) and for DDIs mediated by strong/moderate inhibitors in extensive metabolizers were collected. The impact of DDIs and GDIs on drug exposure was compared using: (1) a descriptive and (2) a physiologically based pharmacokinetic convergence analysis. Results from both approaches indicate that information on DDIs can be used to reliably predict GDIs for CYP2D6 substrates. The situation is more complex for CYP2C9 and CYP2C19 substrates because dose of the inhibitor (CYP2C9) and potency of the inhibitor (CYP2C19) impact the extent to which perpetrator drugs phenotypically convert extensive metabolizers to poor(er) metabolizers.

Lagishetty, Chakradhar V.↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Characterizing Seasonal Variation of the Atmospheric Mixing Layer Height Using Machine Learning Approaches

As machine learning becomes more integrated into atmospheric science, XGBoost has gained popularity for its ability to assess the relative contributions of influencing factors in the atmospheric boundary layer height. To examine how these factors vary across seasons, a seasonal analysis is necessary. However, dividing data by season reduces the sample size, which can affect result reliability and complicate factor comparisons. To address these challenges, this study replaces default parameters with grid search optimization and incorporates cross-validation to mitigate dataset limitations. Using XGBoost with four years of data from the atmospheric radiation measurement (ARM) (Southern Great Plains (SGP) C1 site, cross-validation stabilizes correlation coefficient fluctuations from 0.3 to within 0.1. With optimized parameters, the R value can reach 0.81. Analysis of the C1 site reveals that the relative importance of different factors changes across seasons. Lower tropospheric stability (LTS, ~0.53) is the dominant factor at C1 throughout the year. However, during DJF, latent heat flux (LHF, 0.44) surpasses LTS (0.22). In SON, LTS (0.58) becomes more influential than LHF (0.18). Further comparisons among the four long-term SGP sites (C1, E32, E37, and E39) show seasonal variations in relative importance. Notably, during JJA, the differences in the relative importance of the three factors across all sites are lower than in other seasons. This suggests that boundary layer development in the summer is not dominated by a single factor, reflecting a more intricate process likely influenced by seasonal conditions such as enhanced convective activity, higher temperatures, and humidity, which collectively contribute to a balanced distribution of parameter impacts. Furthermore, the relative importance of LTS gradually increases from morning to noon, indicating that LTS becomes more significant as the boundary layer approaches its maximum height. Consequently, the LTS in the early morning in autumn exhibits greater relative importance compared to other seasons. This reflects a faster development of the mixing layer height (MLH) in autumn, suggesting that it is easier to retrieve the MLH from the previous day during this period. The findings enhance understanding of boundary layer evolution and contribute to improved boundary layer parameterization.

54 ENVIRONMENTAL SCIENCES↗