Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The temporal characteristics of the terrestrial radiation belt

The terrestrial radiation belt effects on the detectors in the Wisconsin equipment are considered. The lowest dark count rate observed in orbit, compared with that measured in the thermal vacuum test on the ground, shows no measurable difference for the solar blind ASCOP 541-F photomultiplier tubes while the EMI-6256B tubes show an increase in minimum dark count of a factor of from 20 to 150 times that observed on the ground. All instruments are perturbed when in the South Atlantic anomaly, but the EMI tubes are by far the most sensitive to it. Indeed, the effect never goes away.

Mcnall, J. F.↗

Design and construction of a remote sensing apparatus

The methods of identifying plant and soil types using remote sensing techniques are described. The equipment employed consists of a balloon system and a mobile remote sensing laboratory housing a radiometer which is mounted on a turret mechanism. The radiometer is made up of a telescope whose lenses are replaced by mirrors which channel received radiation into a monochromator. The radiation is then focused onto detectors for measurement of the intensity of the electromagnetic energy as a function of wavelength. Measurements from a wavelength of 0.2 microns to 15 microns are obtained with the system. diagrams are provided.

Maples, D.↗

Laser-excited fluorescence for measuring atmospheric pollution

System measures amount of given pollutant at specific location. Infrared laser aimed at location has wavelength that will cause molecules of pollutant to fluoresce. Detector separates fluorescence from other radiation and measures its intensity to indicate concentration of pollutant.

Menzies, R. T.↗

Stabilized Nd:YAG laser output

Stabilization system consists of feedback-loop-controlled piezoelectric crystal to one of the reflectors to vary optical path length within laser cavity. Average second harmonic of fundamental 1.06 micrometer laser radiation is detected by integrating detector.

Osmundson, J.↗

Optical proximity detector

Sensitive, relatively inexpensive instrument uses phase-detection techniques to sense presence of objects. Phase-sensitive detectors, LED, photodiode with response matched to LED output, and filtering lens allow detector to operate over narrow radiation band, giving selectivity over stray light.

Hermann, W. A.↗

Thin aluminum filters for use on the Apollo Telescope Mount XUV spectrographs

Thin, unbacked, aluminum film filters were used on two extreme ultraviolet (XUV) instruments flown on the Apollo Telescope Mount of Skylab by the Naval Research Laboratory to transmit the XUV radiation while blocking the longer wavelength radiation that would saturate the detector. The requirements placed on these filters - large size, resistance to degradation by high acoustic and vibration fields, and low pinhole transmittances - were far more severe than those placed on any filters previously flown. Special techniques were developed for vacuum evaporation of the aluminum, removal of the films from the substrates, supporting the films and mounting them to obtain finished filters, and storing them so that no degradation took place. A description of these techniques will be given.

Schumacher, R. J.↗

Accurate solar 'constant' determinations by cavity pyrheliometers

Total solar irradiance was observed outside the earth's atmosphere by three types of absolute cavity pyrheliometer in a June 1976 sounding-rocket experiment. The 1367-W/sq m average solar 'constant' result is uncertain by less than + or - 0.5%, the most accurate determination to date. Nearly simultaneous observations by the Nimbus 6 earth-radiation-budget total-irradiance detector of 1389-W/sq m exceeded the rocket result by 1.6%. These recent results are discussed in the context of a summary of solar-constant determinations made above the troposphere by cavity pyrheliometers.

Willson, R. C.↗

The MOM tunneling diode - Theoretical estimate of its performance at microwave and infrared frequencies

A theoretical analysis of the metal-oxide-metal (MOM) antenna/diode as a detector of microwave and infrared radiation is presented with the experimental verification conducted in the far infrared. It is shown that the detectivity at room temperature can be as high as 10 to the 10th per W Hz exp 1/2 at frequencies of 10 to the 14th Hz in the infrared. As a result, design guidelines are obtained for the lithographic fabrication of thin-film MOM structures that are to operate in the 10-micron region of the infrared spectrum.

Sanchez, A.↗

Focal-plane optimization for detector noise limited performance in cryogenic Fourier transform spectrometer /FTS/ sensors

A study was performed to determine the optimum focal plane configuration including optics, filters and detector-preamplifier selection. The configuration was optimized particularly with respect to minimizing the noise level, but fabrication considerations for a cryogenic environment were also taken into account. The noise terms from source, background, detector electronics and charged particle radiation were quantitatively evaluated. It appears that noise equivalent spectral radiance less than 10 to the -11th W/sq cm per sr per kayser can be achieved between 2.5 and 20 microns.

Mcguirk, M.↗

Spectral mapping of Jupiter and the Galilean satellites in the near infrared

A near-infrared mapping spectrometer is included in the science complement of the Galileo Mission, which will explore Jupiter and its satellites in the mid-1980s. The objectives of the infrared mapping spectrometer experiment are to map compositional units on the surfaces of the Jovian satellites and to characterize the mineral content of these units. For Jupiter's atmosphere, this experiment will investigate such areas as cloud properties and the spatial and temporal variability of minor species. The instrument consists of a telescope, a plane grating spectrometer, a Si and InSb detector array, and a passive radiative cooler. The spectral range is 0.7-5.2 microns, covered with a resolution of 0.025 micron. A wobbling secondary mirror in the telescope provides one dimension of spatial scanning, while the other dimension is provided by motion of the spacecraft scan platform.

Carlson, R. W.↗

Imaging antenna array at 119 microns

A focal-plane imaging antenna array has been demonstrated at 119 microns. The array is a line of evaporated silver bow-tie antennas with bismuth microbolometer detectors on a silicon substrate. Radiation is coupled into the array by a lens placed on the back of the substrate. The bolometers are thermally isolated from the silicon substrate with a half-micron layer of polyimide. The array performance is demonstrated by coherent imaging of a series of holes at half the diffraction-limited cut-off frequency.

Neikirk, N. P.↗

A sun acquisition sensor for spacecraft guidance and control

The combination of a strap-down analog sun acquisition sensor (AS) and an on-board digital programmable signal processor results in a versatile guidance and control system. The combination can orient the rotation axis of a spin-stabilized spacecraft to the sun no matter what the initial attitude of the spacecraft. During the sun orientation process, spacecraft spin rate can be sensed and supplied as an input to the control algorithm. If needed, the AS-signal processor combination can be used to perform a rhumb-line turn maneuver. In case of unexpected spacecraft operating conditions, or unplanned pointing directions, the signal processor program can be updated via earth-based transmission of another program to cover the new situation. Using only three radiation-hard cadmium-sulfide detectors, containing no moving parts, needing only a few microwatts of power, included in a volume of 550 cubic cm (a redundant pair), and weighing only 540 grams, the AS is a small, simple, sturdy sensing device.

Birnbaum, M. M.↗

Heavy Cosmic Ray Measurement Aboard Spacelab-1

A stack of CR-39 plastic track detectors was exposed to cosmic radiation during the 10 days mission aboard Spacelab-1. A part of the stack was rotated one revolution within 7 days. The impact time of most of the particles was correlated with the orbit position of the shuttle and thus with geomagnetic field parameters. The analysis of heavy particles with charge Z greater than or equal to 6 in the energy range 50-150 MeV per nucleon with special emphasis on geomagnetically forbidden particles is reported.

Beaujean, R.↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

Ionization Chamber Measures Extreme Ultraviolet

Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

Carlson, Robert W.↗

Cryogenic Shutter Mechanism

Electromagnetic shutter mechanism operates at ambient and cryogenic temperatures to shield optical element, such as mirror, filter, polarizer, beam splitter, or detector, from external light and radiation in cryogenic Dewar equipped with window for optical evaluation. Shutter mechanism in Dewar container alternately shields and exposes optical element as paddle rotates between mechanical stops. Mounted on cold plate of liquid-helium reservoir. Paddle, shaft, and magnet constitutes assembly rotated by electromagnetic field on coil.

Barney, Richard D.↗

X-ray beam method for displacement measurement in hostile environments

A new method of extensometry using an X-ray beam was devised, and the results of current testing reveal it to be highly feasible. This technique has been shown to provide a non-contacting system that is immune to problems associated with density variations in gaseous environments, that plague currently available optical methods. This advantage is a result of the non-refracting penetrating nature of X-rays. The method is based on X-ray-induced X-ray fluorescence of targets, which subsequently serve as fudicial markers. Some target materials have melting points over 1600 degrees C which will facilitate measurement at extremely high temperatures. A highly focused intense X-ray beam, which is produced using a Johansen 'bent crystal', is then scanned across the target, which responds by fluorescing X-rays when stimulated by the incident beam. This secondary radiation is monitored using a detector. By carefully measuring beam orientation, change in target edge position can be determined. Many variations on this basic theme are now possible such as two targets demarcating a gage length, or a beam shadowing method using opaque targets.

Jordan, Eric H.↗

Report of the ultraviolet and visible sensors panel

In order to meet the science objectives of the Astrotech 21 mission set the Ultraviolet (UV) and Visible Sensors Panel made a number of recommendations. In the UV wavelength range of 0.01 to 0.3 micro-m the focus is on the need for large format high quantum efficiency, radiation hard 'solar-blind' detectors. Options recommended for support include Si and non-Si charge coupled devices (CCDs) as well as photocathodes with improved microchannel plate readouts. For the 0.3 to 0.9 micro-m range, it was felt that Si CCDs offer the best option for high quantum efficiencies at these wavelengths. In the 0.9 to 2.5 micro-m the panel recommended support for the investigation of monolithic arrays. Finally, the panel noted that the implementation of very large arrays will require new data transmission, data recording, and data handling technologies.

Timothy, J. Gethyn↗