Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Low temperature barriers for use with in situ processes

A method of forming and maintaining a low temperature zone around at least a portion of a subsurface treatment area is described. The method includes reducing a temperature of heat transfer fluid with a refrigeration system. The heat transfer fluid is circulated through freeze well canisters and placed in a formation around at least a portion of the subsurface treatment area. An initial temperature of the heat transfer fluid supplied to a first freeze well canister is in a range from about -35 .degree. C. to about -55 .degree. C. At least one of the well canisters includes carbon steel. The heat transfer fluid is returned to the refrigeration system.

36 MATERIALS SCIENCE↗

Realization of Magnetostructural Transition and Magnetocaloric Properties of Ni–Mn–Mo–Sn Heusler Alloys

As magnetic cooling refrigerant, Ni–Mn–Sn Heusler alloys have gained significant potentials for a wide range of practical applications as compared with other expensive Ga-doped Ni–Mn based Heusler alloys, toxic As and P doped Mn-based alloys and rare-earth elements like Gd-based alloys. Consequently, an inclusive investigation on magnetostructural transition and magnetocaloric features of Ni{sub 43}Mn{sub 47−x}Mo{sub x}Sn{sub 10} alloys is carried out. The alloys are assembled through arc-melting technique and their X-ray diffraction analysis confirms their B{sub 2}-type crystal structure at room temperature. As the Mo contents are increased, the magnetostructural transition temperature increases for a temperature range between Curie temperature of austenite and martensite phases. Obvious metamagnetic behavior and magnetic hysteresis are observed in isothermal magnetization curves, suggesting that the temperature and magnetic field can be used as robust tools for tuning the structural transformation in Heusler alloys. The noticeable magnetocaloric effect suggests that the prepared alloys can be an attractive choice for magnetic refrigeration applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy-efficient building technologies

Buildings consume one-third of the total final energy produced on the globe and are responsible for almost 40 percent of total carbon dioxide generation annually. The latest carbon dioxide burden of buildings approached 10 Gigatons in the year 2019. Energy-efficient building technologies are necessary to address the climate change induced by greenhouse gases and fulfill the growth in demand and continuously depleting energy reserves. To meet the net-zero carbon footprint goals, sustainable, renewable energy resources, efficient building technologies, and demand management strategies are needed. Achieving zero emissions will require buildings to be equipped with energy-efficient technologies while completely avoiding on-site fossil fuel consumption and being only powered by renewable energy. In this context, this chapter provides an overview of various building technologies, including envelopes, materials, equipment, appliances, and integration concepts, which will play a significant role in lowering the overall energy consumption in both existing building stock and new buildings. Specifically, the following areas are discussed in detail: emerging building envelope designs, thermal comfort and refrigeration equipment, bridging technologies for improved energy efficiency in the ongoing energy transition, hybrid renewable (photovoltaic) configurations, energy storage technologies, miscellaneous appliances, refrigerants, and renewable fuels. The influence of key design and operating characteristics on annual carbon footprint is presented.

Cheekatamarla, Praveen↗

Giant and reversible room-temperature magnetocaloric effect in Ti-doped Ni-Co-Mn-Sn magnetic shape memory alloys

The practical applications of magnetocaloric materials for magnetic refrigeration require not only large magnitude but also reversibility, as well as room-temperature operating temperature, of the magneto caloric effect. However, it is a complex problem to simultaneously meet these demands in the Heusler-type Ni-(Co)-Mn-X (X = In, Sn, Sb, Ga) magnetic shape memory alloys which are a promising candidate for magnetocaloric materials, owing to the interdependence of magnetostructural transformation parameters. In this work, through synergic tuning of magnetostructural transformation parameters via alloying with Ti in Ni 42-x Ti x Co 9 Mn 39 Sn 10 alloys, we achieved a large reversible room-temperature magnetocaloric effect. By alloying with a proper amount of Ti, the martensitic transformation temperature was brought down to room temperature and the sensitivity of transformation temperature to magnetic field change was greatly enhanced with the transformation entropy change still remaining a large value, while the thermal hysteresis and the transformation interval only slightly increased. Thus, the field required to induce the complete and reversible transformation was significantly reduced. As a result, a large reversible room-temperature magnetic entropy change ΔS m of 18.7 J kg -1 K -1 under 5 T was achieved in the Ni 41 Ti 1 Co 9 Mn 39 Sn 10 alloy. This is the first report on reversibleΔS m in Ni-Mn-Sn-based Heusler alloys and the ΔS m we achieved represents the highest reversible ΔS m under 5 T reported heretofore in Ni-Mn-based Heusler alloys. Furthermore, the Ni 41 Ti 1 Co 9 Mn 39 Sn 10 alloy shows good compressive properties and stable martensitic transformation during thermal cycling, beneficial for potential magnetocaloric applications. This study is instructive for the development of high-performance magnetocaloric materials for room-temperature magnetic refrigeration.

36 MATERIALS SCIENCE↗

Quantifying agricultural productive use of energy load in Sub-Saharan Africa and its impact on microgrid configurations and costs

The use of advanced energy technologies for agricultural purposes—such as irrigation, refrigeration, crop processing, and egg incubation—has the potential to increase crop yield, reduce vulnerability to changing precipitation patterns, increase shelf life, strengthen income and employment opportunities in rural areas, and reduce emissions by displacing fossil fuel-based technologies. These productive uses of energy (PUE) in remote areas could potentially be powered by microgrids that additionally serve otherwise unelectrified communities, most of which are located in rural Sub-Saharan Africa. Here, in this paper, we use high-resolution geospatial data to estimate the end-use electricity demand for a range of agricultural PUE across Sub-Saharan Africa, and we share these data in an open-access mapping tool. Next, we use REopt®, a techno-economic optimization model of energy systems, to determine the cost and system sizing implications of incorporating agricultural PUE into microgrid designs in Kenya and Zambia. We estimate the upper bound of agricultural PUE demand for irrigation, milling, shelling, refrigeration, and egg incubation across Sub-Saharan to be 16.8 TWh/yr. We find that incorporating local agricultural PUE into microgrid system designs increases the required system sizing while having minimal impact on the levelized cost of energy of these systems. Our analysis is the first to demonstrate the PUE potential in the agricultural sector at a 10x10-kilometer resolution across Sub-Saharan Africa and to show, at scale, how site-specific PUE can impact the cost and sizing of microgrids that are otherwise deployed to serve local household and community load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ammonia-based chemisorption heat pumps for cold-climate heating applications: A comprehensive review

This paper reviews the state of the art of chemisorption heat pumps that use ammonia as the refrigerant for cold-climate heating applications. In such a system, ammonia vapor is adsorbed by the solid salt through reversible chemisorption reactions, and the thermal effect of the reaction and ammonia phase change is used to extract heat from a cold environment and supply heat to a warm environment. With the high latent heat and low boiling point of ammonia as a low-temperature refrigerant and the high sorption capacity of ammonia-based chemisorption reactions, chemisorption heat pumps have the potential to produce high-efficiency heating, particularly for cold climates. This review first briefly introduces the basics of ammonia-based chemisorption heat pump systems. Then, the latest development of sorbent materials, including ammoniate salts and heat-conductive porous matrix materials, are summarized with the focus on low-temperature heating conditions. The design of system components, as well as cycle configurations, in the literature are summarized. This review concludes with highlights of recent developments on these topics and suggestions of areas for further research.

42 ENGINEERING↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

High-heat transfer lithium-ion batteries: A new era in battery thermal management

Despite advances in lithium-ion battery technology, critical challenges remain that must be addressed to accelerate electric vehicle (EV) adoption and global energy transformation. Significantly improved battery thermal management (BTM) is key to overcoming these challenges. BTM approaches focus on increasing heat transfer coefficients via air, liquid, or refrigerant cooling, but less attention is given to reducing the battery's thermal resistance, a major bottleneck for heat transfer. This work introduces a novel approach to reduce battery thermal resistance by integrating in-plane heat transfer with optimized cell geometry, minimized thermal resistances, and reduced interfacial resistances, representing a departure from previous methods. The standard prismatic can cell incorporating this technology is referred to as the high heat transfer (HHT) battery. An equivalent resistance battery thermal model is developed for speed and accuracy, validated against experimental data in the literature, demonstrating strong correlation and ensuring reliable predictions for real-world performance. Thermal performance metrics of the conventional and HHT batteries are compared using a parametric study with air, liquid, and refrigerant boundary conditions across a range of aspect ratios. The HHT battery shows a heat removal rate up to 20 times higher than a conventional battery. These findings suggest that HHT technology could be transformative for EV battery performance, enabling fast charging, mitigating thermal runaway, extending battery life, reducing cold-weather power loss, increasing reliability, lowering costs, and enabling higher energy density, all critical for EV adoption and energy transformation. Future work will focus on prototyping and real-world testing to refine these findings for commercial-scale applications.

25 ENERGY STORAGE↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Thermal conductance measurements of bolted copper joints for SuperCDMS

Joint thermal conductance testing has been undertaken for bolted copper to copper connections from 60 mK to 26 K. This testing was performed to validate an initial design basis for the SuperCDMS experiment, where a dilution refrigerator will be coupled to a cryostat via multiple bolted connections. Copper used during testing was either gold plated or passivated with citric acid to prevent surface oxidation. Results obtained are well fit by a power law regression of joint thermal conductance to temperature and match well with data collected during a literature review.

Schmitt, R.↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Designing slippery rough surfaces to enhance dropwise condensation of low surface tension fluid

Enhancing low surface tension liquid condensation is critical for achieving high energy efficiency and reducing the size of thermal energy systems. Extensive research has focused on promoting dropwise condensation of these liquids using state-of-the-art coatings on plain surfaces. However, maintaining dropwise condensation with low surface tension fluids is challenging due to rivulet formation, resulting in wetted tails that transition to filmwise condensation at elevated heat fluxes. Here, to address this issue, we uncover the role of surface structures and surface chemistry in the dropwise condensation of low surface tension ethanol on slippery rough surfaces (SRS). High-performance dropwise condensation has been achieved on slippery microchannels grafted with perfluoropolyether. The SRS uniquely facilitates rapid lateral droplet removal, enabling faster directional droplet shedding without rivulet formation. The resulting higher droplet removal frequency on SRS leads to heat transfer coefficients 100 % and 500 % higher than conventional dropwise and filmwise condensation on plain surfaces, respectively. Our findings uncover the pivotal role of rapid droplet removal through slippery microchannels in sustaining dropwise condensation of low surface tension liquids. This study introduces a new paradigm for promoting dropwise condensation using engineered SRS that incorporates surface structure and surface chemistry. The work will provide fundamental design guidelines to design efficient and compact condensers that use costly or flammable low global warming potential refrigerants in future refrigeration systems.

Dropwise condensation↗

Literature Survey and a Universal Evaporation Correlation for Plate type Heat Exchangers

Plate heat exchangers are widely used in the industry. Being compact in nature, they are good candidates to be used as evaporators with reduced charge. Here, a review of the existing evaporation heat transfer coefficient data for plate heat exchangers has been carried out. The literature survey also includes compilation of available Nusselt number correlations. In this work, an attempt has been made to develop a universal Nusselt number correlation that can be used to predict the heat transfer coefficient during evaporation of several key refrigerants using various plate geometries. The predicted values of Nusselt number using proposed correlation were found to be in good agreement with the experimental data of ammonia (R-717), R-134a, R-410A and few relatively new refrigerants. The proposed correlation is valid for 313 < Re eq < 12,700, 0.000136 < Bo eq < 0.0019 and is shown to predict the actual data within ±30% error. The predicted heat transfer coefficient was also found to be in good agreement with results from the major plate exchanger manufacturers.

42 ENGINEERING↗

Depicting the roles of CuO secondary phase and heat treatment in driving the magnetic and magnetocaloric features of Pr 2/3 Sr 1/3 MnO 3 manganite

In this work, we report a detailed experimental study regarding the impact of copper oxide (CuO) secondary phase and heat treatments on the structural, magnetic, and magnetocaloric properties of the near-room temperature Pr 2/3 Sr 1/3 MnO 3 (PSMO) magnetic refrigerant. Our investigations are carried out by using structural and microstructural analyses, alongside magnetization measurements. Here, the analysis of X-ray diffraction data of PSMO(95%)-CuO(5%) (PSMO-CuO) samples shows the coexistence of both CuO and PSMO phases. Further, the microstructural analysis of PSMO-CuO reveals that the addition of CuO significantly enhances the grains size. On the other hand, the added secondary phase markedly reduces the Curie temperature (T c ) from 293 K for PSMO to about 273 K for PSMO-CuO composite while increasing the magnetocaloric effect. This decrease in T c is associated with a significant change from 162° to about 156° in the Mn-OII-Mn bond angle respectively. Moreover, performed investigations regarding the role of heat treatments unveil that the observed changes in the structural and magnetic features are mainly driven by the secondary phase that modify grains size and double-exchange interactions in the PSMO compound. Interestingly, our findings demonstrate that the Curie temperature of the PSMO and accordingly its magnetocaloric effect can be tailored by adding small amounts of CuO without need to substitution on cation sites. In the light of obtained results, a multilayered refrigerant composed of PSMO and PSMO-CuO is proposed to cover the magnetic cooling temperature range close to room-temperature. The resulting entropy change remains practically constant between 273 K and 293 K. Such a behavior is highly appreciated from a practical point of view, particularly in cases where the cooling process is carried out by using the AMR and Ericsson cycles.

36 MATERIALS SCIENCE↗

Behavior of the magnetocaloric effect and critical exponents in La{sub 0.67}Sr{sub 0.33}Mn{sub 1−x}V{sub x}O{sub 3} manganite oxide

We have investigated the magnetocaloric effect along with magnetic phase transition and critical exponent analysis in mixed manganite La{sub 0.67}Sr{sub 0.33}Mn{sub 1−x}V{sub x}O{sub 3} (0≤x≤0.15). To determine the nature of the paramagnetic to ferromagnetic phase transition, found to be of second-order, we performed a critical exponents study by dc-magnetization M(H,T) measurements around the Curie temperature T{sub C}. Modified Arrott plot method has been adopted to study the critical behavior of the compounds at their transition region, the values of critical exponents β, γ and δ are close to those expected for three-dimensional Heisenberg class with short-range interaction. A large magnetic entropy change |ΔS{sub M}| deduced from isothermal magnetization curves, has been observed in our samples with a peak centered on their respective T{sub C}. With increase in vanadium content, the temperature corresponding to the maximum entropy change as well as the magnetic transition temperature gradually shifts to low temperatures. The field dependence of the magnetic entropy change is also analyzed, which shows the power law dependence namely, ΔS{sub M}∝H{sup n}. Relative cooling power increases from 205 J/kg for x=0.00 to 258 J/Kg for x=0.15 making these materials a promising candidates for magnetic refrigeration near room temperature. - Graphical abstract: Scaling plot below and above T{sub C} using the β and γ exponents determined from the Arrot plot method of La{sub 0.67}Sr{sub 0.33}Mn{sub 1−x}V{sub x}O{sub 3} for x=0.15. - Highlights: • The paramagnetic to ferromagnetic phase transition of La{sub 0.67}Sr{sub 0.33}Mn{sub 1−x}V{sub x}O{sub 3} (0≤x≤0.15) is found to be of second-order. • The field dependence of the magnetic entropy shows the power law dependence namely, ΔS{sub M}∝H{sup n}. • Moderate values of −ΔS{sub M}{sup max} and RCP make the La{sub 0.67}Sr{sub 0.33}Mn{sub 1−x}V{sub x}O{sub 3} compounds potential candidates for magnetic refrigeration applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗