Electron omnidirectional intensity contours in the earth's outer radiation zone at the magnetic equator.
Outer radiation zone electrons omnidirectional intensity contours at magnetic equator
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Outer radiation zone electrons omnidirectional intensity contours at magnetic equator
A population of early star-forming galaxies is the leading candidate for the re-ionization of the universe. It is still unclear, however, what conditions and physical processes would enable a significant fraction of the ionizing (Lyman continuum) photons to escape from these gas-rich galaxies. In this paper we present the results of the analysis of Hubble Space Telescope Cosmic Origins Spectrograph far-UV (FUV) spectroscopy plus ancillary multi-waveband data of a sample of 22 low-redshift galaxies that are good analogs to typical star-forming galaxies at high redshift. We measure three parameters that provide indirect evidence of the escape of ionizing radiation (leakiness): (1) the residual intensity in the cores of saturated interstellar low-ionization absorption lines, which indicates incomplete covering by that gas in the galaxy; (2) the relative amount of blueshifted Lyα line emission, which can indicate the existence of holes in the neutral hydrogen on the front-side of the galaxy outflow, and (3) the relative weakness of the [S ii] optical emission lines that trace matter-bounded H ii regions. We show that our residual intensity measures are only negligibly affected by infilling from resonance emission lines. We find all three diagnostics agree well with one another. We use these diagnostics to rank-order our sample in terms of likely leakiness, noting that a direct measure of escaping Lyman continuum has recently been made for one of the leakiest members of our sample. We then examine the correlations between our ranking and other proposed diagnostics of leakiness. We find a good correlation with the equivalent width of the Lyα emission line, but no significant correlations with either the flux ratio of the [O iii]/[O ii] emission lines or the ratio of star-formation rates derived from the (dust-corrected) FUV and Hα luminosities. Turning to galaxy properties, we find the strongest correlations with leakiness are with the compactness of the star-forming region (Star formation rate/area) and the speed of the galactic outflow. This suggests that extreme feedback—a high intensity of ionizing radiation and strong pressure from both radiation and a hot galactic wind—combines to create significant holes in the neutral gas. These results not only shed new light on the physical mechanisms that can allow ionizing radiation to escape from intensely star-forming galaxies, they also provide indirect observational indicators that can be used at high redshift where direct measurements of escaping Lyman continuum radiation are impossible.
The paper presents the results of investigation the process of formation of the ordered microstructures of dislocations in the near-surface layer a single-crystal plate of silicon under the action of pulsed laser radiation with microstructured distribution intensity. It has been found that generation of the ordered one-dimensional microstructures of dislocations takes place. The period of these ordered microstructures is d{approx_equal}3 divide 4 {mu}m. A combination of one-dimensional structures of dislocations produces ordered two-dimensional structure of dislocations.
Sunspot structure from two dimensional radiative transfer analysis of center limb intensity profiles made at several heliocentric angles
The most intense source of polarized vacuum UV and X radiation is synchrotron radiation, which exhibits a degree of partially polarized light between about 80-100%. However, the radiation transmitted by vacuum UV monochromators can also be highly polarized. The Seya-Namioka type of monochromator can produce partially polarized radiation between 50-80%. For certain experiments it is necessary to know the degree of polarization of the radiation being used. Also, when synchrotron radiation and a monochromator are combined the polarization characteristic of both should be known in order to make full use of these polarization properties. The polarizing effect of monochromators (i.e., diffraction gratings) have been measured at the Seya angle and at grazing angles for various spectral orders. Experimental evidence is presented which shows that the reciprocity law holds for polarization by reflection where the angle of incidence and diffraction are unequal. These results are reviewed along with the techniques for measuring the degree of polarization.
The gravitational field of the sun acts as a spherical lens to magnify the intensity of radiation from a distant source along a semi-infinite focal line. A spacecraft anywhere on that line in principle could observe, eavesdrop, and communicate over interstellar distances, using equipment comparable in size and power with what is now used for interplanetary distances. If one neglects coronal effects, the maximum magnification factor for coherent radiation is inversely proportional to the wavelength, being 100 million at 1 millimeter. The principal difficulties are that the nearest point on the focal half-line is about 550 times the sun-earth distance, separate spacecraft would be needed to work with each stellar system of interest, and the solar corona would severely limit the intensity of coherent radiation while also restricting operations to relatively short wavelengths.
The possibility of protecting a mirror of a laser on the 4d - 4p transitions of nickel-like tantalum ions against spontaneous X-rays by means of a carbon or potassium filter is considered. It is shown that such filters can transmit 75% - 80% of laser radiation at 44.83 A, attenuating at least by half the intensity of radiation incident on the mirror in other spectral regions, which considerably suppresses the double-pass amplification. (control of laser radiation parameters)
Intense gamma radiation has been observed from the direction of the quasar 3C 279 throughout the energy range from 30 MeV to over 5 GeV by the Energetic Gamma Ray Experiment Telescope (EGRET) during the period June 15-28, 1991. Its spectrum is well represented by a photon differential power-law exponent of 2.0 +/- 0.1, with a photon intensity above 100 MeV of (2.8 +/- 0.4) x 10 exp -6/sq cm s. For E is greater than 100 MeV, the 2-sigma upper limits were 1.0 x 10 exp -6/sq cm s in 1973 from the SAS 2 observations and 0.3 x 10 exp -6/sq cm s for the combined 1976, 1978, and 1980 COS B observations. Hence, there has been a large increase in high-energy gamma-ray intensity relative to the earlier times, as there has been in the radio, infrared, optical, and X-ray ranges. This source is the most distant and by far the most luminous gamma-ray source yet detected.
A number of particle physics experiments are being proposed as part of the Department of Energy HEP Intensity Frontier. Many of these experiments will utilize megawatt level proton beams onto targets to form secondary beams of muons, kaons and neutrinos. These experiments require transverse size measurements of the incident proton beam onto target for each beam spill. Because of the high power levels, most beam intercepting profiling techniques will not work at full beam intensity. The possibility of utilizing optical transition radiation (OTR) for high intensity proton beam profiling is discussed. In addition, previous measurements of OTR beam profiles from the NuMI beamline are presented.
Purpose: To assess the relationship for oropharyngeal (OP) cancer and nasopharyngeal (NP) cancer between the dose received by the swallowing structures and the dysphagia related quality of life (QoL). Methods and Materials: Between 2000 and 2005, 85 OP and 47 NP cancer patients were treated by radiation therapy. After 46 Gy, OP cancer is boosted by intensity-modulated radiation therapy (IMRT), brachytherapy (BT), or frameless stereotactic radiation/cyberknife (CBK). After 46 Gy, the NP cancer was boosted with parallel-opposed fields or IMRT to a total dose of 70 Gy; subsequently, a second boost was given by either BT (11 Gy) or stereotactic radiation (SRT)/CBK (11.2 Gy). Sixty OP and 21 NP cancer patients responded to functional and QoL questionnaires (i.e., the Performance Status Scales, European Organization for Research and Treatment of Cancer H and N35, and M.D. Anderson Dysphagia Inventory). The swallowing muscles were delineated and the mean dose calculated using the original three-dimensional computed tomography-based treatment plans. Univariate analyses were performed using logistic regression analysis. Results: Most dysphagia problems were observed in the base of tongue tumors. For OP cancer, boosting with IMRT resulted in more dysphagia as opposed to BT or SRT/CBK. For NPC patients, in contrast to the first booster dose (46-70 Gy), no additional increase of dysphagia by the second boost was observed. Conclusions: The lowest mean doses of radiation to the swallowing muscles were achieved when using BT as opposed to SRT/CBK or IMRT. For the 81 patients alive with no evidence of disease for at least 1 year, a dose-effect relationship was observed between the dose in the superior constrictor muscle and the 'normalcy of diet' (Performance Status Scales) or 'swallowing scale' (H and N35) scores (p < 0.01)
Purpose: The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over a large number of fractions, it may play a role in hypofractionated [stereotactic body radiation therapy (SBRT)] treatments. This subject has been extensively studied for intensity modulated radiation therapy but less so for volumetric modulated arc therapy (VMAT), particularly in application to hypofractionated regimens. Also, no experimental study has provided full four-dimensional (4D) dose reconstruction in this scenario. The authors demonstrate how a recently described motion perturbation method, with full 4D dose reconstruction, is applied to describe the gradient and interplay effects during VMAT lung SBRT treatments.Methods: VMAT dose delivered to a moving target in a patient can be reconstructed by applying perturbations to the treatment planning system-calculated static 3D dose. Ten SBRT patients treated with 6 MV VMAT beams in five fractions were selected. The target motion (motion kernel) was approximated by 3D rigid body translation, with the tumor centroids defined on the ten phases of the 4DCT. The motion was assumed to be periodic, with the period T being an average from the empirical 4DCT respiratory trace. The real observed tumor motion (total displacement ≤8 mm) was evaluated first. Then, the motion range was artificially increased to 2 or 3 cm. Finally, T was increased to 60 s. While not realistic, making T comparable to the delivery time elucidates if the interplay effect can be observed. For a single fraction, the authors quantified the interplay effect as the maximum difference in the target dosimetric indices, most importantly the near-minimum dose (D{sub 99%}), between all possible starting phases. For the three- and five-fractions, statistical simulations were performed when substantial interplay was found.Results: For the motion amplitudes and periods obtained from the 4DCT, the interplay effect is negligible (<0.2%). It is also small (0.9% average, 2.2% maximum) when the target excursion increased to 2–3 cm. Only with large motion and increased period (60 s) was a significant interplay effect observed, with D{sub 99%} ranging from 16% low to 17% high. The interplay effect was statistically significantly lower for the three- and five-fraction statistical simulations. Overall, the gradient effect dominates the clinical situation.Conclusions: A novel method was used to reconstruct the volumetric dose to a moving tumor during lung SBRT VMAT deliveries. With the studied planning and treatment technique for realistic motion periods, regardless of the amplitude, the interplay has nearly no impact on the near-minimum dose. The interplay effect was observed, for study purposes only, with the period comparable to the VMAT delivery time.
HybridArc is a relatively novel radiation therapy technique which combines optimized dynamic conformai arcs (DCA) and intensity modulated radiation therapy (IMRT). HybridArc has possible dosimetry and efficiency advantages over stand alone DCA and IMRT treatments and can be readily implemented on any linac capable of DCA and IMRT, giving strong motivation to commission the modality. The Delta4 phantom (Scandidos, Uppsala, Sweden) has been used for IMRT and VMAT clinical dosimetric verification making it a candidate for HybridArc commissioning. However the HybridArc modality makes use of several non co-planar arcs which creates setup issues due to the geometry of the Delta4, resulting in possible phantom gantry collisions for plans with non-zero couch angles. An analysis was done determining the feasibility of using the Delta4 fixed at 0° couch angle compared with results obtained using Gafchromic ETB2 film (Ashland, Covington Kentucky) in an anthropomorphic phantom at the planned couch angles. A gamma index analysis of the measured and planned dose distributions was done using Delta4 and DoseLab Pro (Mobius Medical Systems, Houston Texas) software. For both arc and IMRT sub-fields there is reasonable correlation between the gamma index found from the Delta4 and Gafchromic film. All results show the feasibility of using the Delta4 for HybridArc commissioning.
Purpose: A novel optical dosimetry technique for the QA and verification of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) radiotherapy plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: An intensified CCD camera (ICCD) was used to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank. The ICCD acquisition was gated to the Linac, operated for single pulse imaging, and binned to a resolution of 512×512 pixels. The resulting videos were analyzed temporally for regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR) and summed to obtain an overall light distribution, which was compared to the expected dose distribution from the TPS using a gammaindex analysis. Results: The chosen camera settings resulted in data at 23.5 frames per second. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.2% and 95.6% agreement between the light distribution and expected TPS dose distribution based upon a 3% / 3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans respectively. Conclusion: The results from this initial study demonstrate the first documented use of Cherenkov radiation for optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications. NIH R01CA109558 and R21EB017559.
Purpose: To compare biophysical indices of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) treatment plans for whole brain radiation therapy following the NRG-CC001 protocol. Methods: In this retrospective study, a total of fifteen patients were planned with Varian Eclipse Treatment Planning System using VMAT (RapidArc) and IMRT techniques. The planning target volume (PTV) was defined as the whole brain volume excluding a uniform three-dimensional 5mm expansion of the hippocampus volume. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 95% of the target volume receiving 100% of the prescribed dose. The NRG Oncology protocol guidelines were followed for contouring and dose-volume constraints. A single radiation oncologist evaluated all treatment plans. Calculations of statistical significance were performed using Student’s paired t-test. Results: All VMAT and IMRT plans met the NRG-CC001 protocol dose-volume criteria. The average equivalent uniform dose (EUD) for the PTV for VMAT vs. IMRT was respectively (19.05±0.33 Gy vs. 19.38±0.47 Gy) for α/β of 2 Gy and (19.47±0.30 Gy vs. 19.84±0.42 Gy) for α/β of 10 Gy. For the PTV, the average mean and maximum doses were 2% and 5% lower in VMAT plans than in IMRT plans, respectively. The average EUD and the normal tissue complication probability (NTCP) for the hippocampus in VMAT vs. IMRT plans were (15.28±1.35 Gy vs. 15.65±0.99 Gy, p=0.18) and (0.305±0.012 Gy vs. 0.308±0.008 Gy, p=0.192), respectively. The average EUD and NTCP for the optic chiasm were both 2% higher in VMAT than in IMRT plans. Conclusion: Though statistically insignificant, VMAT plans indicate a lower hippocampus EUD than IMRT plans. Also, a small variation in NTCP was found between plans.
Purpose: When treatment intent is to include breast and internal mammary lymph nodes (IMNs) in the clinical target volume (CTV), a significant volume of the heart may receive radiation, which may result in late morbidity. The value of conformal intensity-modulated radiation therapy (IMRT) to avoid heart dose was studied. Methods and Materials: Breast, IMNs, and normal tissues were contoured for 30 consecutive patients previously treated with RT after lumpectomy for left-sided breast cancer. Eleven-beam, conformal, inverse-planned IMRT plans were developed and compared with best standard plans. Conformity Index (CI), Homogeneity Index (HI), and doses to normal tissues were compared. Results: Intensity-modulated RT significantly improved (two-sided paired t test) HI (0.95 vs. 0.74), CI (0.91 vs. 0.48), volume of the heart receiving more than 30 Gy (V30-heart) (1.7% vs. 12.5%), and volume of lung receiving more than 20-Gy (V20-left lung) (17.1% vs. 26.6%), all p < 0.001. The mean Healthy Tissue Volume (HTV = CT set - PTV) dose was similar between IMRT and best standard plans (6.0 and 6.9 Gy, respectively), but IMRT increased the volume of normal tissues receiving low-dose RT: V5-right lung (13.7% vs. 2.0%), V5-right breast (29.2% vs. 7.9%), and V5-HTV (31.7% vs. 23.6%), all p < 0.001. IMRT plans were generated in less than 60 min and treatment delivered in approximately 20 min, suggesting that this technique is clinically applicable. Conclusions: IMRT significantly improved conformity and homogeneity for plans when the breast + IMNs were in the CTV. Heart and lung volume receiving high doses were decreased, but more healthy tissue received low doses. A simple algorithm based on amount of heart included in the standard plan showed limited ability to predict the benefit from IMRT.
Invited John and Naomi Fackler Lectureship in Chemistry and English seminar at Valparaiso University, IN, USA. Actinides are inherently unstable elements that frequently coexist with other radioisotopes, generating intense ionizing radiation fields that drive the formation of non-equilibrium oxidation states. These transient species exert a profound mechanistic influence on the radiation response of actinide-containing systems due to their unique redox chemistry. Despite their importance, they remain poorly understood, yet such insight is essential for advancing actinide science and accurately predicting radiation-driven behavior. Actinide separations—critical for nuclear energy technologies, strategic deterrence, space exploration, and nuclear medicine—depend on precise control of actinide oxidation states to recover targeted elements from complex matrices such as used nuclear fuel. However, during these processes, actinides, their coordination complexes, and the separation media are all exposed to intense, multicomponent (alpha, beta, gamma, etc.) radiation fields that can alter process efficiency, selectivity, and chemical stability. Understanding, controlling, and mitigating radiation-induced reactions is therefore key to innovating and optimizing next-generation separation technologies. This seminar will provide an overview of the nuclear fuel cycle and non-equilibrium actinide radiation chemistry in the context of recovering actinides from used nuclear fuel, with a particular emphasis on direct-dissolution–based reprocessing strategies. We will explore time-resolved electron pulse radiolysis and gamma dose accumulation studies to elucidate the molecular-level roles of radiation-driven, non-equilibrium actinide species in process performance and in the radiolytic stability of organic ligands used for actinide recovery. These insights offer new pathways for designing advanced separation methods and next-generation solvent systems, with broad implications for the future of the nuclear fuel cycle.
We have modeled the fluorescent pumping of electronic and vibrational emissions of molecular hydrogen (H2) within diffuse molecular clouds that are illuminated by ultraviolet continuum radiation. Fluorescent line intensities are predicted for transitions at ultraviolet, infrared, and red visible wavelengths as functions of the gas density, the visual extinction through the cloud, and the intensity of the incident UV continuum radiation. The observed intensity in each fluorescent transition is roughly proportional to the integrated rate of H2 photodissociation along the line of sight. Although the most luminous fluorescent emissions detectable from ground-based observatories lie at near-infrared wavelengths, we argue that the lower sky brightness at visible wavelengths makes the red fluorescent transitions a particularly sensitive probe. Fabry-Perot spectrographs of the type that have been designed to observe very faint diffuse Ha emissions are soon expected to yield sensitivities that will be adequate to detect H2 vibrational emissions from molecular clouds that are exposed to ultraviolet radiation no stronger than the mean radiation field within the Galaxy. Observations of red H2 fluorescent emission together with cospatial 21 cm H I observations could serve as a valuable probe of the gas density in diffuse molecular clouds.
Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.