At least 1,207 records · Page 67

In situ observations of magnetosonic waves modulated by background plasma density

We report in situ observations by the Van Allen Probe mission that magnetosonic (MS) waves are clearly relevant to the background plasma number density. As the satellite moved across dense and tenuous plasma alternatively, MS waves occurred only in lower density region. As the observed protons with “ring” distributions provide free energy, local linear growth rates are calculated and show that magnetosonic waves can be locally excited in tenuous plasma. With variations of the background plasma density, the temporal variations of local wave growth rates calculated with the observed proton ring distributions show a remarkable agreement with those of the observed wave amplitude. Therefore, the paper provides a direct proof that background plasma densities can modulate the amplitudes of magnetosonic waves through controlling the wave growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of cell adhesion force by vertical forcible detachment using an arrowhead nanoneedle and atomic force microscopy

Graphical abstract: - Highlights: • We developed a method to measure cell adhesion force by detaching cell using an arrowhead nanoneedle and AFM. • A nanofilm consisting of fibronectin and gelatin was formed on cell surface to reinforce the cell cortex. • By the nanofilm lamination, detachment efficiencies of strongly adherent cell lines were improved markedly. - Abstract: The properties of substrates and extracellular matrices (ECM) are important factors governing the functions and fates of mammalian adherent cells. For example, substrate stiffness often affects cell differentiation. At focal adhesions, clustered–integrin bindings link cells mechanically to the ECM. In order to quantitate the affinity between cell and substrate, the cell adhesion force must be measured for single cells. In this study, forcible detachment of a single cell in the vertical direction using AFM was carried out, allowing breakage of the integrin–substrate bindings. An AFM tip was fabricated into an arrowhead shape to detach the cell from the substrate. Peak force observed in the recorded force curve during probe retraction was defined as the adhesion force, and was analyzed for various types of cells. Some of the cell types adhered so strongly that they could not be picked up because of plasma membrane breakage by the arrowhead probe. To address this problem, a technique to reinforce the cellular membrane with layer-by-layer nanofilms composed of fibronectin and gelatin helped to improve insertion efficiency and to prevent cell membrane rupture during the detachment process, allowing successful detachment of the cells. This method for detaching cells, involving cellular membrane reinforcement, may be beneficial for evaluating true cell adhesion forces in various cell types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A large gap of radio frequency dielectric barrier atmospheric pressure glow discharge

A large gap was acquired between electrodes (up to 5.5 mm) of Ar atmospheric pressure glow discharge in radio frequency dielectric barrier discharge (rf-DBD). The discharge of Ar plasma was characterized by I-V curve and Lissajous plot, and the effective power of the discharge was calculated based on the measured Lissajous plot and found to be higher than 90% of the input power. To gain a thorough understanding of the mechanism, the rf-DBD with a single dielectric barrier layer operating in gamma mode glow discharge of N{sub 2} plasma was diagnosed in spatial resolution through optical emission spectroscopy. It was concluded that secondary electron emission might be responsible for the sustainable glow discharge in the large gap rf-DBD plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of gas mixing ratio on etch behavior of ZrO{sub 2} thin films in BCl{sub 3}/He inductively coupled plasma

This article reports a study carried out on a model-based analysis of the etch mechanism for ZrO{sub 2} thin films in a BCl{sub 3}/He inductively coupled plasma. It was found that an increase in the He mixing ratio at a fixed gas pressure and input power results in an increase in the ZrO{sub 2} etch rate, which changes from 36 to 57 nm/min for 0-83% He. Langmuir probe diagnostics and zero-dimensional plasma modeling indicated that both plasma parameters and active species kinetics were noticeably influenced by the initial composition of the BCl{sub 3}/He mixture, resulting in the nonmonotonic or nonlinear behaviors of species densities. Using the model-based analysis of etch kinetics, it was demonstrated that the behavior of the ZrO{sub 2} etch rate corresponds to the ion-flux-limited etch regime of the ion-assisted chemical reaction.

36 MATERIALS SCIENCE↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spontaneous symmetry breaking in magnetized dust flows

Toroidal dust flows in magnetized anodic plasmas are driven by an azimuthal Hall component of the ion drag. By means of Langmuir probe measurements, it was found that the ion drag has a strong radial gradient. This finding is supported by the rotation velocities obtained by particle tracking analysis. The topology of shear flows is also attributed to the radial gradient of the ion drag. Furthermore, from a critical comparison of particle image velocimetry and particle tracking, a much better agreement between the measured rotation velocity and simulations could be achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oblique ion collection in the drift approximation: How magnetized Mach probes really work

The anisotropic fluid equations governing a frictionless obliquely flowing plasma around an essentially arbitrarily shaped three-dimensional ion-absorbing object in a strong magnetic field are solved analytically in the quasineutral drift approximation, neglecting parallel temperature gradients. The effects of transverse displacements traversing the magnetic presheath are also quantified. It is shown that the parallel collection flux density dependence upon the external Mach number is n{sub {infinity}}c{sub s} exp[-1-(M{sub parallel}{infinity}-M{sub perpendicular}cot {theta})], where {theta} is the angle (in the plane of field and drift velocity) of the object-surface to the magnetic-field and M{sub parallel{infinity}} is the external parallel flow. The perpendicular drift, M{sub perpendicular}, appearing here consists of the external E and B drift plus a weighted sum of the ion and electron diamagnetic drifts that depends upon the total angle of the surface to the magnetic field. It is that somewhat counterintuitive combination that an oblique (transverse) Mach probe experiment measures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Immersion Ion Implantation with Solid Targets for Space and Aerospace Applications

This paper describes successful results obtained by a new type of plasma source, named as Vaporization of Solid Targets (VAST), for treatment of materials for space and aerospace applications, by means of plasma immersion ion implantation and deposition (PIII and D). Here, the solid element is vaporized in a high pressure glow discharge, being further ionized and implanted/deposited in a low pressure cycle, with the aid of an extra electrode. First experiments in VAST were run using lithium as the solid target. Samples of silicon and aluminum alloy (2024) were immersed into highly ionized lithium plasma, whose density was measured by a double Langmuir probe. Measurements performed with scanning electron microscopy (SEM) showed clear modification of the cross-sectioned treated silicon samples. X-ray photoelectron spectroscopy (XPS) analysis revealed that lithium was implanted/deposited into/onto the surface of the silicon. Implantation depth profiles may vary according to the condition of operation of VAST. One direct application of this treatment concerns the protection against radiation damage for silicon solar cells. For the case of the aluminum alloy, X-ray diffraction analysis indicated the appearance of prominent new peaks. Surface modification of A12024 by lithium implantation/deposition can lower the coefficient of friction and improve the resistance to fatigue of this alloy. Recently, cadmium was vaporized and ionized in VAST. The main benefit of this element is associated with the improvement of corrosion resistance of metallic substrates. Besides lithium and cadmium, VAST allows to performing PIII and D with other species, leading to the modification of the near-surface of materials for distinct purposes, including applications in the space and aerospace areas.

36 MATERIALS SCIENCE↗

Laser-induced fluorescence measurements of argon and xenon ion velocities near the sheath boundary in 3 ion species plasmas

The Bohm sheath criterion is studied with laser-induced fluorescence in three ion species plasmas using two tunable diode lasers. Krypton is added to a low pressure unmagnetized DC hot filament discharge in a mixture of argon and xenon gas confined by surface multi-dipole magnetic fields. The argon and xenon ion velocity distribution functions are measured at the sheath-presheath boundary near a negatively biased boundary plate. The potential structures of the plasma sheath and presheath are measured by an emissive probe. Results are compared with previous experiments with Ar–Xe plasmas, where the two ion species were observed to reach the sheath edge at nearly the same speed. This speed was the ion sound speed of the system, which is consistent with the generalized Bohm criterion. In such two ion species plasmas, instability enhanced collisional friction was demonstrated [Hershkowitz et al., Phys. Plasmas 18(5), 057102 (2011).] to exist which accounted for the observed results. When three ion species are present, it is demonstrated under most circumstances the ions do not fall out of the plasma at their individual Bohm velocities. It is also shown that under most circumstances the ions do not fall out of the plasma at the system sound speed. These observations are also consistent with the presence of the instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Galileo attitude and articulation control system - A radiation-hard, high precision, state-of-the-art control system

The Galileo mission and spacecraft, consisting of a Jupiter-orbiter and an atmospheric entry probe, are discussed. Components will include: magnetometers and plasma-wave antennas on a boom, high-gain antenna, probe vehicle, two different bus electronics packages, and a radioisotope thermoelectric generator. Instruments, investigators and objectives are tabulated for both probe science and orbiter science investigations. Requirements in the design of the attitude and articulation control system are very stringent because of the complex dynamics, flexible body effects, the need for autonomy, and the severe radiation environment in the Jupiter nighborhood. Galileo was intended to be ready for launch via Space Shuttle in May of 1986.

Stephenson, R. Rhoads↗

Measurement of sheath thickness at a floating potential

In a cylindrical Langmuir probe measurement, ion current is collected from the surface of the sheath surrounded at probe tip, not at the surface of the probe tip. By using this, the sheath thickness can be obtained, if we know some unknown parameters, such as ion current, plasma density, and electron temperature. In this paper, we present a method to measure sheath thickness by using a wave cutoff method and a floating harmonic method. The measured result is in a good agreement with Allen-Boyd-Reynolds theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High repetition rate plasma mirror device for attosecond science

This report describes an active solid target positioning device for driving plasma mirrors with high repetition rate ultra-high intensity lasers. The position of the solid target surface with respect to the laser focus is optically monitored and mechanically controlled on the nm scale to ensure reproducible interaction conditions for each shot at arbitrary repetition rate. We demonstrate the target capabilities by driving high-order harmonic generation from plasma mirrors produced on glass targets with a near-relativistic intensity few-cycle pulse laser system operating at 1 kHz. During experiments, residual target surface motion can be actively stabilized down to 47 nm (root mean square), which ensures sub-300-as relative temporal stability of the plasma mirror as a secondary source of coherent attosecond extreme ultraviolet radiation in pump-probe experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion velocity and plasma potential measurements of a cylindrical cusped field thruster

Measurements of the most probable time-averaged axial ion velocities and plasma potential within the acceleration channel and in the plume of a straight-channeled cylindrical cusped field thruster operating on xenon are presented. Ion velocities for the thruster are derived from laser-induced fluorescence measurements of the 5d[4]{sub 7/2}-6p[3]{sub 5/2} xenon ion excited state transition centered at {lambda}=834.72nm. Plasma potential measurements are made using a floating emissive probe with a thoriated-tungsten filament. The thruster is operated in a power matched condition with 300 V applied anode potential for comparison to previous krypton plasma potential measurements, and a low power condition with 150 V applied anode potential. Correlations are seen between the plasma potential drop outside of the thruster and kinetic energy contours of the accelerating ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Outer midplane scrape-off layer profiles and turbulence in simulations of Alcator C-Mod inner-wall limited discharges

A region of steep plasma gradients, the so-called ”narrow-feature”, has been found in the near scrape-off layer (SOL) of inner-wall limited (IWL) discharges. Dedicated IWL discharges were carried out in Alcator C-Mod [E.S. Marmar et al., Nucl. Fusion 55, (2015)] to study this phenomenon, allowing detailed observations of the plasma profiles and fluctuations. Langmuir probe (LP) measurements show a clear two decay length n e and T e profile structure at the outer midplane. The Gas-Puff Imaging (GPI) diagnostic shows large turbulent fluctuations across the last closed flux-surface, hence supporting the hypothesis that turbulent phenomena play a role in setting the profile steepness. We have carried out the flux-driven non-linear turbulence simulations of two C-Mod discharges which allows a three-way comparison between LP, GPI, and simulation data. Observations and simulations correlate the steep gradient region characterizing the narrow feature with sheared poloidal flows and a deviation of the plasma potential from its floating value. Furthermore, the E x B shear rate exceeds the linear ballooning growth rate, indicating that the narrow feature could result from the effects of sheared flows, although causality could not be established. The fluctuation level in the narrow feature remains of order unity across the entire SOL, indicating that the transport reduction in the near-SOL cannot result from a simple quench rule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atom probe analysis of AlN interlayers in AlGaN/AlN/GaN heterostructures

Atom probe tomography was used to characterize AlN interlayers in AlGaN/AlN/GaN heterostructures grown by plasma-assisted molecular beam epitaxy (PAMBE), NH{sub 3}-based molecular beam epitaxy (NH{sub 3}-MBE), and metal-organic chemical vapor deposition (MOCVD). The PAMBE-grown AlN interlayer had the highest purity, with nearly 100% of group-III sites occupied by Al. The group-III site concentrations of Al for interlayers grown by NH{sub 3}-MBE and MOCVD were {approx}85% and {approx}47%, respectively. Hall measurements were performed to determine the two-dimensional electron gas mobility and sheet concentration. Sheet concentrations were {approx}25%-45% higher with molecular beam epitaxy than with MOCVD, and these results matched well with atom probe data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time control of electron density in a capacitively coupled plasma

Reactive ion etching (RIE) is sensitive to changes in chamber conditions, such as wall seasoning, which have a deleterious effect on process reproducibility. The application of real time, closed loop control to RIE may reduce this sensitivity and facilitate production with tighter tolerances. The real-time, closed loop control of plasma density with RF power in a capacitively coupled argon plasma using a hairpin resonance probe as a sensor is described. Elementary control analysis shows that an integral controller provides stable and effective set point tracking and disturbance attenuation. The trade off between performance and robustness may be quantified in terms of one parameter, namely the position of the closed loop pole. Experimental results are presented, which are consistent with the theoretical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗