Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

First Science Results from ZEPLIN-III

ZEPLIN-III uses a 12 kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced interactions in the liquid to differentiate between nuclear recoils expected from WIMPs and electron recoil background signals down to approx10 keV nuclear recoil energy. Analysis of 847 kgcentre dotdays of data acquired between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon elastic scattering spin-independent cross-section above 8.1x10approx{sup -8} pb at 60 GeVc{sup -2} with a 90% confidence limit. ZEPLIN-III demonstrated better discrimination at low-energy than previously achieved by any other xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic ray anisotropies to 5 PeV

Several large cosmic ray (CR) detectors have recently provided data on the arrival directions of CR, which taken together with previous data recorded over many decades allow the amplitude and phase of the first harmonic to be derived with reasonable precision and up to higher energies. We find a high degree of consistency amongst the various measurements. The new data indicate that at an energy above ∼ 0.1 PeV a change of the CR anisotropy sets in. The amplitude of the first harmonic, which rises to 3 TeV, then diminishes and begins to rise again. The direction of the phase also changes to the opposite one. A measure of understanding follows from the use of two-dimensional maps of cosmic ray excesses over the mean background. When the energy of cosmic rays approaches the PeV region, the excess of cosmic rays moves from the Galactic Anti-Centre to the opposite direction of the Galactic Centre. The possible role of such potential cosmic ray sources as the supernovae Monogem Ring and Vela, which could help to explain some of the observed results, is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Unraveling cosmological anisotropies within stochastic gravitational wave backgrounds

Identifying the anisotropies in a cosmologically sourced stochastic gravitational wave background (SGWB) would be of significance in shedding light on the nature of primordial inhomogeneities. For example, if SGWB carries isocurvature fluctuations, it would provide evidence for a multi-field inflationary origin of these inhomogeneities. However, this is challenging in practice due to finite detector sensitivity and also the presence of the astrophysical foregrounds that can compete with the cosmological signal. In this work, we explore the prospects for measuring cosmological SGWB anisotropies in the presence of an astrophysical counterpart and detector noise. To illustrate the main idea, we perform a Fisher analysis using a well-motivated cosmological SGWB template corresponding to a first order phase transition, and an astrophysical SGWB template corresponding to extra-galactic binary mergers, and compute the uncertainty with which various parameters characterizing the isotropic and anisotropic components can be extracted. Finally, we also discuss some subtleties and caveats involving shot noise in the astrophysical foreground. Overall, we show that upcoming experiments, e.g., LISA, Taiji, Einstein Telescope, Cosmic Explorer, and BBO, can all be effective in discovering plausible anisotropic cosmological SGWBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma rays and gravitational waves from inelastic Higgs portal dark matter

We explore a simple and predictive dark matter scenario involving a complex scalar field, ϕ , coupled to the Higgs portal with no additional field content. In the UV, the field possesses a global U ( 1 ) symmetry which is broken by mass terms and Higgs portal interactions. In the mass basis, the complex field splits into a pair of real scalars with a small mass splitting (in analogy to pseudo-Dirac fermions), such that the Higgs portal acquires both diagonal and off-diagonal terms with respect to these eigenstates. In the parameter space where the off-diagonal interaction predominates, this scenario is safe from direct detection constraints. Moreover, this model provides a viable explanation for the longstanding Galactic Center γ -ray excess. Additionally, this model influences the Higgs potential in a way that could facilitate a strong first-order electroweak phase transition in the early Universe, potentially leading to a stochastic gravitational wave background that could fall within the reach of upcoming space-based detectors.

Hooper, Dan [Wisconsin U., Madison] (ORCID:0009000↗

Experimental study on discretely modulated continuous-variable quantum key distribution

We present a discretely modulated continuous-variable quantum key distribution system in free space by using strong coherent states. The amplitude noise in the laser source is suppressed to the shot-noise limit by using a mode cleaner combined with a frequency shift technique. Also, it is proven that the phase noise in the source has no impact on the final secret key rate. In order to increase the encoding rate, we use broadband homodyne detectors and the no-switching protocol. In a realistic model, we establish a secret key rate of 46.8 kbits/s against collective attacks at an encoding rate of 10 MHz for a 90% channel loss when the modulation variance is optimal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward a neutrino-limited dark matter search with crystalline xenon

Experiments searching for weakly interacting massive particle dark matter are now detecting background events from solar neutrino-electron scattering. However, the dominant radioactive background in state-of-the-art experiments such as LZ and XENONnT is beta decays from radon contamination. In spite of careful detector material screening, radon progenitor atoms are ubiquitous and long-lived, and radon is extremely soluble in liquid xenon. We propose a change of phase and demonstrate that crystalline xenon offers more than a factor × 500 exclusion against radon ingress, compared with the liquid state. This level of radon exclusion would allow crystallized versions of existing experiments to probe spin-independent cross sections near 10 − 47 cm 2 in roughly 11 years, as opposed to the 35 years required otherwise. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for CP violation in B{sub s}{sup 0{yields}{mu}+}D{sub s}{sup -}X decays in pp collisions at {radical}(s)=1.96 TeV

We have performed a search for CP violation in a sample of B{sub s}{sup 0{yields}{mu}+}D{sub s}{sup -}X decays corresponding to 5 fb{sup -1} of proton-antiproton collisions collected by the D0 detector in Run II at the Fermilab Tevatron Collider. New physics in B{sub s}{sup 0} mixing could contribute a significant CP violating weak phase, which would be observed as a difference in the decay-time distribution for B{sub s}{sup 0{yields}}B{sub s}{sup 0} oscillated states versus that for B{sub s}{sup 0{yields}}B{sub s}{sup 0}. A fit to the decay-time distributions of the B{sub s}{sup 0}/B{sub s}{sup 0} candidates yields the flavor-specific asymmetry a{sub fs}{sup s}=[-1.7{+-}9.1(stat){sub -1.5}{sup +1.4}(syst)]x10{sup -3}, which excludes CP violation due to new physics within the experimental sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ab Initio Uncertainty Quantification of Neutrinoless Double-Beta Decay in 76 Ge

The observation of neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay would offer proof of lepton number violation, demonstrating that neutrinos are Majorana particles, while also helping us understand why there is more matter than antimatter in the Universe. If the decay is driven by the exchange of the three known light neutrinos, a discovery would, in addition, link the observed decay rate to the neutrino mass scale through a theoretical quantity known as the nuclear matrix element (NME). Accurate values of the NMEs for all nuclei considered for use in 0⁢𝜈⁢𝛽⁢𝛽 experiments are therefore crucial for designing and interpreting those experiments. Here, we report the first comprehensive ab initio uncertainty quantification of the 0⁢𝜈⁢𝛽⁢𝛽-decay NME, in the key nucleus 76 Ge. Here, our method employs nuclear strong and weak interactions derived within chiral effective field theory and recently developed many-body emulators. Our result, with a conservative treatment of uncertainty, is an NME of 2.60$^{+1.28}_{−1.36}$, which, together with the best-existing half-life sensitivity and phase-space factor, sets an upper limit for effective neutrino mass of 187$^{+205}_{−62}$ meV. The result is important for designing next generation germanium detectors aiming to cover the entire inverted hierarchy region of neutrino masses.

Ab initio calculations↗

Correlation Processing Of Local Seismic Data: Applications for Autonomous Sensor Deployments

Excavation and operation of an underground facility is likely to produce an extensive suite of seismic signals observable at the surface for perhaps several km. Probably a large fraction of such signals will be correlated, so the design of a monitoring framework should include consideration of a correlation processing capability. Correlation detectors have been shown to be significantly more sensitive than beam-forming power detectors. Although correlation detectors have a limited detection footprint, they can be generalized into multi-rank subspace detectors which are sensitive over a much larger range of source mechanisms and positions. Production of subspace detectors can be automated, so their use in an autonomous framework may be contemplated. Waveform correlation also can be used to produce very high precision phase picks which may be jointly inverted to simultaneously relocate groups of events. The relative precision of the resulting hypocenters is sufficient to visualize structural detail at a scale of less than a few tens of meters. Three possible correlation processor systems are presented. All use a subspace signal detection framework. The simplest system uses a single-component sensor and is capable of detection and classification of signals. The most complicated system uses many sensors deployed around the facility, and is capable of detection, classification, and high-precision source location. Data from a deep underground mine are presented to demonstrate the applicability of correlation processing to monitoring an underground facility. Although the source region covers an area of about 600m by 580m, all but two of the events form clusters at a threshold of 0.7. All the events could have been detected and classified by the subspace detection framework, and high-precision picks can be computed for all cluster members.

58 GEOSCIENCES↗

Time-Resolved Hanbury Brown–Twiss Interferometry of On-Chip Biphoton Frequency Combs Using Vernier Phase Modulation

Biphoton frequency combs (BFCs) are promising quantum sources for large-scale and high-dimensional quantum information and networking systems. In this context, the spectral purity of individual frequency bins will be critical for realizing quantum networking protocols like teleportation and entanglement swapping. Measurement of the temporal autocorrelation function of the unheralded signal or idler photons comprising the BFC is a key tool for characterizing their spectral purity and in turn verifying the utility of the biphoton state for networking protocols. Yet the experimentally obtainable precision for measuring BFC correlation functions is often severely limited by detector jitter. The fine temporal features in the correlation function—not only of practical value in quantum information, but also of fundamental interest in the study of quantum optics—are lost as a result. We propose a scheme to circumvent this challenge through electro-optic phase modulation, experimentally demonstrating time-resolved Hanbury Brown–Twiss characterization of BFCs generated from an integrated 40.5-GHz Si 3 N 4 microring, up to a 3×3-dimensional two-qutrit Hilbert space. Through slight detuning of the electro-optic drive frequency from the comb’s free spectral range, our approach leverages Vernier principles to magnify temporal features, which would otherwise be averaged out by detector jitter. We demonstrate our approach under both continuous-wave and pulsed-pumping regimes, finding excellent agreement with theory. In conclusion, our method reveals not only the collective statistics of the contributing frequency bins but also their temporal shapes—features lost in standard fully integrated autocorrelation measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Beam-Correlated Background Neutrons from the Fermilab Booster Neutrino Beam in ANNIE Phase-I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) aims to make a unique measurement of neutron yield from neutrino-nucleus interactions and to perform R&D for the next generation of water-based neutrino detectors. In this paper, we characterize beam-induced neutron backgrounds in the experimental hall at Fermi National Accelerator Laboratory. It is shown that the background levels are sufficiently low to allow the next stage of the experiment to proceed. These measurements are relevant to other Booster Neutrino Beam (BNB) [1] experiments located adjacent to ANNIE Hall, where dirt neutrons and sky-shine could present similar backgrounds.

Particle identification methods↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Measurements of jet vetoes and azimuthal decorrelations in dijet events produced in pp collisions at √s = 7 TeV using the ATLAS detector

In addition jet activity in dijet events is measured using pp collisions at ATLAS at a centre-of-mass energy of 7TeV, for jets reconstructed using the anti-k t algorithm with radius parameter R=0.6. This is done using variables such as the fraction of dijet events without an additional jet in the rapidity interval bounded by the dijet subsystem and correlations between the azimuthal angles of the dijet s. They are presented, both with and without a veto on additional jet activity in the rapidity interval, as a function of the scalar average of the transverse momenta of the dijet s and of the rapidity interval size. The double differential dijet cross section is also measured as a function of the interval size and the azimuthal angle between the dijet s. These variables probe differences in the approach to resummation of large logarithms when performing QCD calculations. The data are compared to POWERHEG , interfaced to the PYTHIA 8 and HERWIG parton shower generators, as well as to HEJ with and without interfacing it to the ARIADNE parton shower generator. None of the theoretical predictions agree with the data across the full phase-space considered; however, POWERHEG + PYTHIA 8 and HEJ + ARIADNE are found to provide the best agreement with the data. These measurements use the full data sample collected with the ATLAS detector in 7TeV pp collisions at the LHC and correspond to integrated luminosities of 36.1pb –1 and 4.5fb –1 for data collected during 2010 and 2011, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the LUX dark matter experiment

© 2014 Elsevier B.V. The LUX (Large Underground Xenon) experiment aims at the direct detection of dark matter particles via their collisions with xenon nuclei. The 370. kg two-phase liquid xenon time projection chamber measures simultaneously the scintillation and ionization from interactions in the target. The ratio of these two signals provides very good discrimination between potential nuclear recoil and electronic recoil signals to search for WIMP-nucleon scattering. The LUX detector operates at the Sanford Underground Research Facility (Lead, South Dakota, USA) since February 2013. First results were presented in late 2013 setting the world's most stringent limits on WIMP-nucleon scattering cross-sections over a wide range of WIMP masses. A 300 day run beginning in 2014 will further improve the sensitivity and new calibration techniques will reduce systematics for the WIMP signal search.

Horn, Markus↗

Large electric-induced pyroelectric properties in (Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} antiferroelectric ceramics with excess PbO

(Pb{sub 0.87}La{sub 0.02}Ba{sub 0.1}) (Zr{sub 0.7}Sn{sub 0.24}Ti{sub 0.06})O{sub 3} (PLBZST) antiferroelectric ceramics with the addition of 0-9 wt. % excess PbO were fabricated by the conventional solid-state reaction process, and their microstructure, dielectric, and pyroelectric properties were systemically investigated. When excess PbO content was less than 9 wt. %, two pyrochlore phases were formed along with the perovskite phase. Compared with common specimens, PLBZST antiferroelectric ceramics with excess PbO exhibited a higher pyroelectric coefficient and a lower dielectric loss, which are beneficial for the development of pyroelectric devices. Around the Curie temperature, as the excess PbO increased from 0 wt. % to 9 wt. %, PLBZST ceramics' pyroelectric coefficient increased from 1600 {mu}C/m{sup 2}K to 4000 {mu}C/m{sup 2}K, and the figure of merit increased from 40 x 10{sup -5} Pa{sup -0.5} to 140 x 10{sup -5} Pa{sup -0.5} under a 400 V/mm dc field. The largest figure of merit of 200 x 10{sup -5} Pa{sup -0.5}, which is about 8 times higher than that of conventional phase transition materials barium strontium titanate (BST), was obtained in PLBZST ceramics with 6 wt. % excess PbO when a 600 V/mm dc bias field was applied. Therefore, improvement of pyroelectric property is beneficial for the development of infrared detectors.

36 MATERIALS SCIENCE↗

Capability for time-resolved diffraction for material phase in extreme conditions (Q2 FY24 Report)

After a series of development experiments, a new x-ray diffraction diagnostic called FIDDLE (Flexible Imaging Diffraction Diagnostic for Laser Experiments) has been designed, built, and fielded on four shots at NIF. Here we document the initial performance of FIDDLE fielded as the detector in the time-resolved x-ray diffraction experimental platform. Early challenges with EMP have been documented using offline testing in the Target Diagnostics Factory to identify EMP leaks. These techniques were used to guide the application of shielding to weak spots where EM radiation was able to penetrate inside the diagnostic. Application of shielding was found to be effective at reducing EMP leaks, enabling detection of x-ray diffraction on three temporally separated frames during a high pressure (~1Mbar) experiment where lead (Pb) was observed to undergo a phase transition from HCP to BCC.

36 MATERIALS SCIENCE↗

Overview of the Liquid Argon Cryogenics for the Short Baseline Neutrino Program (SBN) at Fermilab

The Short-Baseline Neutrino (SBN) physics program will involve three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-scale through both appearance and disappearance oscillation channels. The Program will be composed of an existing and operational detector known as Micro Boone (170 ton LAr mass) plus two new experiments known as the SBN Near Detector (SBND, ~ 260 ton) and the SBN Far Detector (SBN-FD, ~ 600 tons). Fermilab is now building two new facilities to house the experiments and incorporate all cryogenic and process systems to operate these detectors beginning in the 2018-2019 time frame. The SBN cryogenics are a collaborative effort between Fermilab and CERN. The SBN cryogenic systems for both detectors are composed of several sub-systems: External/Infrastructure (or LN2), Proximity (or LAr), and internal cryogenics. For each detector the External/Infrastructure cryogenics includes the equipment used to store and the cryogenic fluids needed for the operation of the Proximity cryogenics, including the LN2 and LAr storage facilities. The Proximity cryogenics consists of all the systems that take the cryogenic fluids from the external/infrastructure cryogenics and deliver them to the internal at the required pressure, temperature, purity and mass flow rate. It includes the condensers, the LAr and GAr purification systems, the LN2 and LAr phase separators, and the interconnecting piping. The Internal cryogenics is comprised of all the cryogenic equipment located within the cryostats themselves, including the GAr and LAr distribution piping and the piping required to cool down the cryostats and the detectors. These cryogenic systems will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution presents the performance, the functional requirements and the modes of operation of the SBN cryogenics, and details the current status of the design, present and future needs.

Norris, Barry↗