Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Symmetry, microscopy and spectroscopy signatures of altermagnetism

The recent discovery of altermagnetism was in part motivated by the research of compensated magnets towards highly scalable spintronic technologies. Simultaneously, altermagnetism shares the anisotropic higher-partial-wave nature of ordering with unconventional superfluid phases, which have been at the forefront of research for the past several decades. These examples illustrate the interest in altermagnetism from a broad range of science and technology perspectives. Here we review the symmetry, microscopy and spectroscopy signatures of altermagnetism. We describe the spontaneously broken and retained symmetries that delineate altermagnetism as a distinct phase of matter with d-, g- or i-wave compensated collinear spin ordering. In materials ranging from weakly interacting metals to strongly correlated insulators, the microscopic crystal-structure realizations of the altermagnetic symmetries feature a characteristic ferroic order of anisotropic higher-partial-wave components of atomic-scale spin densities. These symmetry and microscopy signatures of altermagnetism are directly reflected in spin-dependent electronic spectra and responses. Here, we review salient band-structure features originating from the altermagnetic ordering, and from its interplay with spin–orbit coupling and topological phenomena. Throughout, we compare altermagnetism with traditional ferromagnetism and Néel antiferromagnetism, and with magnetic phases with symmetry-protected compensated non-collinear spin orders. We accompany the theoretical discussions with references to relevant experiments.

Jungwirth, Tomas [Czech Academy of Sciences, Pragu↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Subcellular localization of leptin and leptin receptor in breast cancer detected in an electron microscopic study

Leptin (LEP) and leptin receptor (LEPR) have long been found associated with breast cancer. So far no high-resolution method such as electron microscopy has been used to investigate the subcellular localization of leptin and leptin receptor in breast cancer. We collected cancer and non-cancer breast tissues from 51 women with invasive ductal breast cancer. Leptin and leptin receptor in the tissues were estimated using immunohistochemistry (IHC). LEP and LEPR were localized at subcellular level by immunocytochemistry (ICC) using ultra-fine gold particle conjugated antibody, and visualized with transmission electron microscopy (TEM). IHC showed high presence of LEP and LEPR in 65% and 67% respectively of the breast cancer samples, 100% and 0% respectively of the adipose tissue samples, and no high presence in the non-cancer breast tissue samples. On TEM views both LEP and LEPR were found highly concentrated within the nucleus of the cancer cells, indicating that nucleus is the principal seat of action. However, presence of high concentration of LEP does not necessarily prove its over-expression, as often concluded, because LEP could be internalized from outside by LEPR in the cells. In contrast, LEPR is definitely over-expressed in the ductal breast cancer cells. Therefore, we hypothesize that over-expression of LEPR, rather than that of LEP has a fundamental role in breast carcinogenesis in particular, and probably for LEP-LEPR associated tumors in general. - Highlights: • Leptin-leptin receptor complex is localized mostly in and around the nucleus. • Nucleus might be the final seat of action of leptin-leptin receptor complex. • Immunohistochemistry can prove over-expression of leptin receptor, not of leptin. • Over-expression of leptin receptor is of primary importance in breast cancer.

60 APPLIED LIFE SCIENCES↗

Ferroelectric Domain Studies of Patterned (001) BiFeO 3 by Angle-Resolved Piezoresponse Force Microscopy

We have studied the ferroelectric domains in (001) BiFeO 3 (BFO) films patterned into mesas with various aspect ratios, using angle-resolved piezoresponse force microscope (AR-PFM), which can image the in-plane polarization component with an angular resolution of 30 degrees. We observed not only stable polarization variants, but also meta-stable polarization variants, which can reduce the charge accumulated at domain boundaries. We considered the number of neighboring domains that are in contact, in order to analyze the complexity of the ferroelectric domain structure. Comparison of the ferroelectric domains from the patterned and unpatterned regions showed that the elastic relaxation induced by removal of the film surrounding the mesas led to a reduction of the average number of neighboring domains, indicative of a decrease in domain complexity. Finally, we also found that the rectangular BFO patterns with high aspect ratio had a simpler domain configuration and enhanced piezoelectric characteristics than square-shaped mesas. Manipulation of the ferroelectric domains by controlling the aspect ratio of the patterned BFO thin film mesas can be useful for nanoelectronic applications.

36 MATERIALS SCIENCE↗

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING↗

Design and Characterization of a MEMS Probe Scanner for On-chip Atomic Force Microscopy

This paper presents the design and characterization of a microelectromechanical systems (MEMS)-based probe scanner proposed to function as an on-chip atomic force microscope (AFM). The device comprises an in-plane stage with electrostatic actuators and electrothermal displacement sensors. The stage is able to precisely position an AFM probe over a sample to perform tapping-mode AFM imaging. For implementation, a standard silicon-on-insulator (SOI) microfabrication process is used. In a previously reported design, the embedded AFM probe featured only one piezoelectric transducer for simultaneous actuation and sensing, making its use in imaging problematic. To address this issue, the new design features separate actuation and sensing AlN piezoelectric transducers. An extra electrode is also incorporated on the probe that enables canceling the electrical feedthrough from the actuation to sensing. To accommodate the extra signal routing paths, mechanical design of the probe scanner is modified. Device characterization reveals an in-plane displacement range of 8 µm×7 µm with a bandwidth of up to 2.7 kHz. The frequencydomain behavior of the AFM probe is also studied and feedthrough cancellation is performed at the resonant frequency of 127.35 kHz.

42 ENGINEERING↗

Combined infrared and analytical electron microscope studies of interplanetary dust particles

Ultramicrotomed thin sections (less than 100 nm thick) of eight chondritic interplanetary dust particles (IDPs) were studied by analytical electron microscopy and IR microspectroscopy with the objective of identifying IDPs or their specific components with IR spectral transmission characteristics at 10 microns similar to those of comets. Two IDPs are identified whose silicate emission characteristics between 8 and 12 microns are similar to those of comets Halley and Bradfield. Implanted solar flare tracks and sputtered rims resulting from solar wind damage suggest that the minerology and petrography of these IDPs have not been significantly perturbed since ejection from their parent bodies.

Bradley, J. P.↗

Tunneling magnetic force microscopy

We have developed a powerful new tool for studying the magnetic patterns on magnetic recording media. This was accomplished by modifying a conventional scanning tunneling microscope. The fine-wire probe that is used to image surface topography was replaced with a flexible magnetic probe. Images obtained with these probes reveal both the surface topography and the magnetic structure. We have made a thorough theoretical analysis of the interaction between the probe and the magnetic fields emanating from a typical recorded surface. Quantitative data about the constituent magnetic fields can then be obtained. We have employed these techniques in studies of two of the most important issues of magnetic record: data overwrite and maximizing data-density. These studies have shown: (1) overwritten data can be retrieved under certain conditions; and (2) improvements in data-density will require new magnetic materials. In the course of these studies we have developed new techniques to analyze magnetic fields of recorded media. These studies are both theoretical and experimental and combined with the use of our magnetic force scanning tunneling microscope should lead to further breakthroughs in the field of magnetic recording.

Burke, Edward R.↗

Versatile atomic force microscopy setup combined with micro-focused X-ray beam

Micro-focused X-ray beams produced by third generation synchrotron sources offer new perspective of studying strains and processes at nanoscale. Atomic force microscope setup combined with a micro-focused synchrotron beam allows precise positioning and nanomanipulation of nanostructures under illumination. In this paper, we report on integration of a portable commercial atomic force microscope setup into a hard X-ray synchrotron beamline. Details of design, sample alignment procedure, and performance of the setup are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution dichroic imaging of magnetic flux distributions in superconductors with scanning x-ray microscopy

The penetration of magnetic flux into high-temperature superconductors has been observed using a high-resolution technique based on x-ray magnetic circular dichroism. Superconductors coated with thin soft-magnetic layers are observed in a scanning x-ray microscope under the influence of external magnetic fields. Resulting electric currents in the superconductor create an inhomogeneous magnetic field distribution above the superconductor and lead to a local reorientation of the ferromagnetic layer. Measuring the local magnetization of the ferromagnet by x-ray absorption microscopy with circular-polarized radiation allows the analysis of the magnetic flux distribution in the superconductor with a spatial resolution on the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aperiodic reflection diffraction gratings for soft X-ray radiation and their application

We briefly review the works concerned with the development and experimental use of the spectral instruments based on aperiodic reflection gratings whose spacing varies monotonically across the aperture according to a prescribed law (VLS gratings). The review considers the employment of VLS-grating instruments intended for the spectroscopy of laboratory and astrophysical plasmas, including the diagnostics of relativistic laser plasmas, for measuring X-ray laser linewidths, for recording the high-order harmonics of laser radiation, the radiation of fast electric discharges and other laboratory X-ray sources, as well as in reflectometry, X-ray fluorescence analysis and microscopy with the use of synchrotron radiation and laser-plasma radiation, and in emission spectroscopy combined with an electron microscope. Also discussed are achievements in the recently undertaken design and development of special-purpose VLS spectrometers intended for the investigation of the electronic structure of different materials and molecules by the spectroscopic technique of resonant inelastic X-ray scattering of synchrotron radiation. We describe flat-field grazing-incidence spectrometers with concave VLS gratings, which are compatible with modern CCD detectors, as well as plane VLS gratings, which are the key elements of scanning high- and ultrahigh-resolution spectrometers/monochromators with a constant deviation angle and stigmatic (imaging) spectrometers, which are also compatible with CCD detectors. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A bi-channel aided stitching of atomic force microscopy images

Microscopy is an essential tool in scientific research, enabling the visualization of structures at micro- and nanoscale resolutions. However, the field of microscopy often encounters limitations in field-of-view (FOV), restricting the amount of sample that can be imaged in a single capture. To overcome this limitation, image stitching techniques have been developed to seamlessly merge multiple overlapping images into a single, high-resolution composite. The images collected from microscope need to be optimally stitched before accurate physical information can be extracted from post analysis. However, the existing stitching tools either struggle to stitch images together when the microscopy images are feature sparse or cannot address all the transformations of images when performing image stitching. To address these issues, we propose a bi-channel aided feature-based image stitching method and demonstrate its use on Atomic Force Microscopy (AFM) generated Pantoea sp. YR343 biofilm and PTO thin film sample images as experimental data. The topographical channel image of AFM data captures the morphological details of the sample, and a stitched topographical image is desired for researchers. We utilize the amplitude and phase channels of AFM data to maximize the matching features and to estimate the position of the original topographical images and show that the proposed bi-channel aided stitching method outperforms the traditional direct stitching approach in AFM topographical image stitching task. Here, we demonstrated the application on AFM, but similar approaches could be employed of optical microscopy with brightfield and fluorescence channels. We believe this proposed workflow can serve as a valuable augmentation strategy for microscopy image stitching tasks and will benefit the experimentalist to avoid erroneous analysis and discovery due to incorrect stitching.

Atomic force microscopy↗

Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the transcritical mixing of fuels at diesel engine conditions

Whilst the physics of both classical evaporation and supercritical fluid mixing are reasonably well characterized and understood in isolation, little is known about the transition from one to the other in the context of liquid fuel systems. The lack of experimental data for microscopic droplets at realistic operating conditions impedes the development of phenomenological and numerical models. To address this issue we performed systematic measurements using high-speed long-distance microscopy, for three single-component fuels (n-heptane, n-dodecane, n-hexadecane), into gas at elevated temperatures (700–1200 K) and pressures (2–11 MPa). We describe these high-speed visualizations and the time evolution of the transition from liquid droplet to fuel vapour at the microscopic level. The measurements show that the classical atomization and vaporisation processes do shift to one where surface tension forces diminish with increasing pressure and temperature, but the transition to diffusive mixing does not occur instantaneously when the fuel enters the chamber. Rather, subcritical liquid structures exhibit surface tension in the near-nozzle region and then, after time surrounded by the hot ambient gas and fuel vapour, undergo a transition to a dense miscible fluid. Although there was clear evidence of surface tension and primary atomization for n-dodecane and n-hexadecane for a period of time at all the above conditions, n-heptane appeared to produce a supercritical fluid from the nozzle outlet when injected at the most elevated conditions (1200 K, 10 MPa). This demonstrates that the time taken by a droplet to transition to diffusive mixing depends on the pressure and temperature of the gas surrounding the droplet as well as the fuel properties. We summarise our observations into a phenomenological model which describes the morphological evolution and transition of microscopic droplets from classical evaporation through a transitional mixing regime and towards diffusive mixing, as a function of operating conditions. We provide criteria for these regime transitions as reduced pressure–temperature correlations, revealing the conditions where transcritical mixing is important to diesel fuel spray mixing.

02 PETROLEUM↗

In situ radiation damage studies of La{sub x}Sr{sub 1-3x/2}TiO{sub 3} perovskites

Seven perovskite samples in the La{sub x}Sr{sub 1-3x/2}TiO{sub 3} solid solution series were monitored in situ during irradiation with 1.0 MeV Kr{sup 2+} ions using the intermediate voltage electron microscope-Tandem User Facility (IVEM) at Argonne National Laboratory. All the perovskites pass through the crystalline-amorphous transformation. However, the critical temperature for amorphisation T{sub c} of the La{sub x}Sr{sub 1-3x/2}TiO{sub 3} perovskites varies nonlinearly with composition, decreasing from 394{+-}3 K for SrTiO{sub 3} to a minimum of 275{+-}1 K for La{sub 0.2}Sr{sub 0.7}TiO{sub 3}, then increasing with composition again to 865{+-}3 K for La{sub 0.67}TiO{sub 3}. In combination with the work of previous authors, the electron microscopy results and IVEM data in this study suggest that there is a vacancy-assisted recovery mechanism in the cubic perovskites with compositions in the range 0<x<0.2 that may not be directly associated with the cubic-tetragonal phase transformation and that vacancy-enhanced amorphisation occurs for both cubic and orthorhombic perovskites with compositions in the range x={approx}0.2-0.67.

36 MATERIALS SCIENCE↗

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗

Detection of defects buried in metallic samples by scanning microwave microscopy

This paper reports the local detection of buried calibrated metal defects in metal samples by a new experimental technique, scanning microwave microscopy. This technique combines the electromagnetic measurement capabilities of a microwave vector network analyzer with the subnanometer-resolution capabilities of an atomic force microscope. The network analyzer authorizes the use of several frequencies in the range 1-6 GHz, allowing three-dimensional tomographical investigation, which is useful for the detection of bulk defects in metal materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗