Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Reed Solomon codes for error control in byte organized computer memory systems

A problem in designing semiconductor memories is to provide some measure of error control without requiring excessive coding overhead or decoding time. In LSI and VLSI technology, memories are often organized on a multiple bit (or byte) per chip basis. For example, some 256K-bit DRAM's are organized in 32Kx8 bit-bytes. Byte oriented codes such as Reed Solomon (RS) codes can provide efficient low overhead error control for such memories. However, the standard iterative algorithm for decoding RS codes is too slow for these applications. Some special decoding techniques for extended single-and-double-error-correcting RS codes which are capable of high speed operation are presented. These techniques are designed to find the error locations and the error values directly from the syndrome without having to use the iterative algorithm to find the error locator polynomial.

Lin, S.↗

Optimization of the artificial viscosity in Lagrangian staggered discretization codes. Modeling 1D stand-alone shock - case study

We have developed new measures of errors for numerical shock. The new approach is based on analysis of the structure function, and separation of the errors related to oscillations and shock width, which also include error in the position of the ”center” of the numerical shock. We have demonstrated that those measures correctly characterize the numerical solution. We introduced an objective function in, which both types of errors are weighted, and presented optimal values of the coefficients of the linear and quadratic viscosity for different weights and different Mach numbers.

97 MATHEMATICS AND COMPUTING↗

Validation and Error Characterization for the Global Precipitation Measurement

The Global Precipitation Measurement (GPM) is an international effort to increase scientific knowledge on the global water cycle with specific goals of improving the understanding and the predictions of climate, weather, and hydrology. These goals will be achieved through several satellites specifically dedicated to GPM along with the integration of numerous meteorological satellite data streams from international and domestic partners. The GPM effort is led by the National Aeronautics and Space Administration (NASA) of the United States and the National Space Development Agency (NASDA) of Japan. In addition to the spaceborne assets, international and domestic partners will provide ground-based resources for validating the satellite observations and retrievals. This paper describes the validation effort of Global Precipitation Measurement to provide quantitative estimates on the errors of the GPM satellite retrievals. The GPM validation approach will build upon the research experience of the Tropical Rainfall Measuring Mission (TRMM) retrieval comparisons and its validation program. The GPM ground validation program will employ instrumentation, physical infrastructure, and research capabilities at Supersites located in important meteorological regimes of the globe. NASA will provide two Supersites, one in a tropical oceanic and the other in a mid-latitude continental regime. GPM international partners will provide Supersites for other important regimes. Those objectives or regimes not addressed by Supersites will be covered through focused field experiments. This paper describes the specific errors that GPM ground validation will address, quantify, and relate to the GPM satellite physical retrievals. GPM will attempt to identify the source of errors within retrievals including those of instrument calibration, retrieval physical assumptions, and algorithm applicability. With the identification of error sources, improvements will be made to the respective calibration, assumption, or algorithm. The instrumentation and techniques of the Supersites will be discussed. The GPM core satellite, with its dual-frequency radar and conically scanning radiometer, will provide insight into precipitation drop-size distributions and potentially increased measurement capabilities of light rain and snowfall. The ground validation program will include instrumentation and techniques commensurate with these new measurement capabilities.

Bidwell, Steven W.↗

Modal Correction Method For Dynamically Induced Errors In Wind-Tunnel Model Attitude Measurements

This paper describes a method for correcting the dynamically induced bias errors in wind tunnel model attitude measurements using measured modal properties of the model system. At NASA Langley Research Center, the predominant instrumentation used to measure model attitude is a servo-accelerometer device that senses the model attitude with respect to the local vertical. Under smooth wind tunnel operating conditions, this inertial device can measure the model attitude with an accuracy of 0.01 degree. During wind tunnel tests when the model is responding at high dynamic amplitudes, the inertial device also senses the centrifugal acceleration associated with model vibration. This centrifugal acceleration results in a bias error in the model attitude measurement. A study of the response of a cantilevered model system to a simulated dynamic environment shows significant bias error in the model attitude measurement can occur and is vibration mode and amplitude dependent. For each vibration mode contributing to the bias error, the error is estimated from the measured modal properties and tangential accelerations at the model attitude device. Linear superposition is used to combine the bias estimates for individual modes to determine the overall bias error as a function of time. The modal correction model predicts the bias error to a high degree of accuracy for the vibration modes characterized in the simulated dynamic environment.

Buehrle, R. D.↗

Design and flight test of a differential GPS/inertial navigation system for approach/landing guidance

NASA-Langley has conducted a flight test program evaluating a differential GPS/inertial navigation system's (DGPS/INS) utility as an approach/landing aid. The DGPS/INS airborne and ground components are based on off-the-shelf transport aircraft avionics, namely a global positioning/inertial reference unit (GPIRU) and two GPS sensor units (GPSSUs). Systematic GPS errors are measured by the ground GPSSU and transmitted to the aircraft GPIRU, allowing the errors to be eliminated or greatly reduced in the airborne equipment. Over 120 landings were flown; 36 of these were fully automatic DGPS/INS landings.

Vallot, Lawrence↗

Statistical analysis of modeling error in structural dynamic systems

The paper presents a generic statistical model of the (total) modeling error for conventional space structures in their launch configuration. Modeling error is defined as the difference between analytical prediction and experimental measurement. It is represented by the differences between predicted and measured real eigenvalues and eigenvectors. Comparisons are made between pre-test and post-test models. Total modeling error is then subdivided into measurement error, experimental error and 'pure' modeling error, and comparisons made between measurement error and total modeling error. The generic statistical model presented in this paper is based on the first four global (primary structure) modes of four different structures belonging to the generic category of Conventional Space Structures (specifically excluding large truss-type space structures). As such, it may be used to evaluate the uncertainty of predicted mode shapes and frequencies, sinusoidal response, or the transient response of other structures belonging to the same generic category.

Hasselman, T. K.↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How do tradeoffs in satellite spatial and temporal resolution impact snow water equivalent reconstruction?

Given the tradeoffs between spatial and temporal resolution, questions about resolution optimality are fundamental to the study of global snow. Answers to these questions will inform future scientific priorities and mission specifications. Heterogeneity of mountain snowpacks drives a need for daily snow cover mapping at the slope scale (≤30 m) that is unmet for a variety of scientific users, ranging from hydrologists to the military to wildlife biologists. But finer spatial resolution usually requires coarser temporal or spectral resolution. Thus, no single sensor can meet all these needs. Recently, constellations of satellites and fusion techniques have made noteworthy progress. The efficacy of two such recent advances is examined: (1) a fused MODIS–Landsat product with daily 30 m spatial resolution and (2) a harmonized Landsat 8 and Sentinel 2A and B (HLS) product with 3–4 d temporal and 30 m spatial resolution. State-of-the-art spectral unmixing techniques are applied to surface reflectance products from 1 and 2 to create snow cover and albedo maps. Then an energy balance model was run to reconstruct snow water equivalent (SWE). For validation, lidar-based Airborne Snow Observatory SWE estimates were used. Results show that reconstructed SWE forced with 30 m resolution snow cover has lower bias, a measure of basin-wide accuracy, than the baseline case using MODIS (463 m cell size) but greater mean absolute error, a measure of per-pixel accuracy. However, the differences in errors may be within uncertainties from scaling artifacts, e.g., basin boundary delineation. Other explanations are (1) the importance of daily acquisitions and (2) the limitations of downscaled forcings for reconstruction. Conclusions are as follows: (1) spectrally unmixed snow cover and snow albedo from MODIS continue to provide accurate forcings for snow models and (2) finer spatial and temporal resolution through sensor design, fusion techniques, and satellite constellations are the future for Earth observations, but existing moderate-resolution sensors still offer value.

Edward H. Bair↗

Error control for reliable digital data transmission and storage systems

A problem in designing semiconductor memories is to provide some measure of error control without requiring excessive coding overhead or decoding time. In LSI and VLSI technology, memories are often organized on a multiple bit (or byte) per chip basis. For example, some 256K-bit DRAM's are organized in 32Kx8 bit-bytes. Byte oriented codes such as Reed Solomon (RS) codes can provide efficient low overhead error control for such memories. However, the standard iterative algorithm for decoding RS codes is too slow for these applications. In this paper we present some special decoding techniques for extended single-and-double-error-correcting RS codes which are capable of high speed operation. These techniques are designed to find the error locations and the error values directly from the syndrome without having to use the iterative alorithm to find the error locator polynomial. Two codes are considered: (1) a d sub min = 4 single-byte-error-correcting (SBEC), double-byte-error-detecting (DBED) RS code; and (2) a d sub min = 6 double-byte-error-correcting (DBEC), triple-byte-error-detecting (TBED) RS code.

Costello, D. J., Jr.↗

Error growth in operational ECMWF forecasts

A parameterization scheme used at the European Centre for Medium Range Forecasting to model the average growth of the difference between forecasts on consecutive days was extended by including the effect of error growth on forecast model deficiencies. Error was defined as the difference between the forecast and analysis fields during the verification time. Systematic and random errors were considered separately in calculating the error variance for a 10 day operational forecast. A good fit was obtained with measured forecast errors and a satisfactory trend was achieved in the difference between forecasts. Fitting six parameters to forecast errors and differences that were performed separately for each wavenumber revealed that the error growth rate grew with wavenumber. The saturation error decreased with the total wavenumber and the limit of predictability, i.e., when error variance reaches 95 percent of saturation, decreased monotonically with the total wavenumber.

Kalnay, E.↗

Velocities of Thwaites and Land glaciers

Changes in the area of volume of polar ice sheets are intricately linked to changes in global climate and may severely impact the densely populated coastal regions on Earth. An ice sheet's velocity is a critical parameter, which, together with ice thickness, allows the determination of discharge rates. Using moderate-resolution satellite images such as Landsat, the velocity of floating ice can be measured quickly and relatively inexpensively by tracing crevasse patterns on shelves and ice tongues. Errors in measured velocities are as little as 0.02 km per year, if the following criteria are met: (1) the time interval is longer than 10 years; (2) the velocity is higher than 0.5 km per year; (3) the coregistration points are well dispersed and enclose the area to be measured; and (4) the image pair includes a Landsat 4 or 5 image. The fewer of these conditions that are met, the less accurate the results become; but even for poor conditions, the velocities are generally reliable to near 0.1 km per year. We are in the process of obtaining velocities of all ice shelves and ice tongues along the Bakutis and Ruppert coasts, wherever suitable crevasse patterns exist. So far, we have obtained velocities for the Thwaites and Land glacier tongues.

Lucchitta, B. K.↗

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

Low-Speed Flow Studies Using the Pressure Sensitive Paint Technique

Optical pressure measurements have been made on a NACA 0012 airfoil coated with Pressure Sensitive Paint (PSP) at very low flow speeds (less than 50 m/s). Angle of attack was limited to 5 deg. for most measurements. Effects of temperature gradients and mis-registration errors on PSP response have been established and minimized. By reducing measurement error caused by these effects. PSP sensitivity has been enhanced. Acceptable aerodynamic data at flow speeds down to 20 m/s have been obtained and valid pressure paint response was observed down to 10 m/s. Measurement errors (in terms of pressure and pressure coefficient) using PSP with pressure taps as a reference are provided for the range of flow speeds from 50 m/s to 10 m/s.

Brown, O. C.↗

The Mark III VLBI System

Geodetic measurements have errors in centimeter range. Collection of three reports describes both equipment and results of some measurements taken with Mark III very-long-baseline interferometry (VLBI) system. Has demonstrated high accuracy over short baselines, where phase-delay measurements used. Advanced hardware, called Mark III A, developed to improve system performance and efficiency. Original Mark III hardware and III A subsystem upgrades developed as part of NASA Crustal Dynamics Project at Haystack Observatory.

Rogers, A. E. E.↗

NASA Tech Briefs, February 2010

Topics covered include: Insulation-Testing Cryostat With Lifting Mechanism; Optical Testing of Retroreflectors for Cryogenic Applications; Measuring Cyclic Error in Laser Heterodyne Interferometers; Self-Referencing Hartmann Test for Large-Aperture Telescopes; Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser; Reconfigurable Hardware for Compressing Hyperspectral Image Data; Spatio-Temporal Equalizer for a Receiving-Antenna Feed Array; High-Speed Ring Bus; Nanoionics-Based Switches for Radio-Frequency Applications; Lunar Dust-Tolerant Electrical Connector; Compact, Reliable EEPROM Controller; Quad-Chip Double-Balanced Frequency Tripler; Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers; Radiation-Hardened Solid-State Drive; Use of Nanofibers to Strengthen Hydrogels of Silica, Other Oxides, and Aerogels; Two Concepts for Deployable Trusses; Concentric Nested Toroidal Inflatable Structures; Investigating Dynamics of Eccentricity in Turbomachines; Improved Low-Temperature Performance of Li-Ion Cells Using New Electrolytes; Integrity Monitoring of Mercury Discharge Lamps; White-Light Phase-Conjugate Mirrors as Distortion Correctors; Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer; ICER-3D Hyperspectral Image Compression Software; and Context Modeler for Wavelet Compression of Spectral Hyperspectral Images.

Source record↗

Broadband Performance of TPF's High-contrast Imaging Testbed: Modeling and Simulations

The broadband performance of the high-contrast imaging testbed (HCIT) at JPL is investigated through optical modeling and simulations. The analytical tool is an optical simulation algorithm developed by combining the HCIT's optical model with a speckle-nulling algorithm that operates directly on coronagraphic images, an algorithm identical to the one currently being used on the HCIT to actively suppress scattered light via a deformable mirror. It is capable of performing full three-dimensional end-to-end near-field diffraction analysis on the HCIT's optical system. By conducting speckle-nulling optimization, we clarify the HCIT's capability and limitations in terms of its broadband contrast performance under various realistic conditions. Considered cases include non-ideal occulting masks, such as a mask with optical density and wavelength dependent parasitic phase-delay errors (i.e., a not band-limited occulting mask) and the one with an optical-density profile corresponding to a measured, non-standard profile, as well as the independently measured phase errors of all optics. Most of the information gathered on the HCIT's optical components through measurement and characterization over the last several years at JPL has been used in this analysis to make the predictions as accurate as possible. The best contrast values predicted so far by our simulations obtainable on the HCIT illuminated with a broadband light having a bandwidth of 80nm and centered at 800nm wavelength are Cm=1.1x10-8 (mean) and C4=4.9x10-8 (at 4(lamda)/D), respectively. In this paper we report our preliminary findings about the broadband light performance of the HCIT.

integrated modeling↗

TH-AB-202-05: BEST IN PHYSICS (JOINT IMAGING-THERAPY): First Online Ultrasound-Guided MLC Tracking for Real-Time Motion Compensation in Radiotherapy

Purpose: While MLC tracking has been successfully used for motion compensation of moving targets, current real-time target localization methods rely on correlation models with x-ray imaging or implanted electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging yields volumetric data in real-time (4D) without ionizing radiation. We report the first results of online 4D ultrasound-guided MLC tracking in a phantom. Methods: A real-time tracking framework was installed on a 4D ultrasound station (Vivid7 dimension, GE) and used to detect a 2mm spherical lead marker inside a water tank. The volumetric frame rate was 21.3Hz (47ms). The marker was rigidly attached to a motion stage programmed to reproduce nine tumor trajectories (five prostate, four lung). The 3D marker position from ultrasound was used for real-time MLC aperture adaption. The tracking system latency was measured and compensated by prediction for lung trajectories. To measure geometric accuracy, anterior and lateral conformal fields with 10cm circular aperture were delivered for each trajectory. The tracking error was measured as the difference between marker position and MLC aperture in continuous portal imaging. For dosimetric evaluation, 358° VMAT fields were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using a 3%/3 mm γ-test. Results: The tracking system latency was 170ms. The mean root-mean-square tracking error was 1.01mm (0.75mm prostate, 1.33mm lung). Tracking reduced the mean γ-failure rate from 13.9% to 4.6% for prostate and from 21.8% to 0.6% for lung with high-modulation VMAT plans and from 5% (prostate) and 18% (lung) to 0% with low modulation. Conclusion: Real-time ultrasound tracking was successfully integrated with MLC tracking for the first time and showed similar accuracy and latency as other methods while holding the potential to measure target motion non-invasively. SI was supported by the Graduate School for Computing in Medicine and Life Science, German Excellence Initiative [grant DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗