Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

SARS-CoV-2 Cases Reported on International Arriving and Domestic Flights: United States, January 2020–December 2021

Objectives. To describe trends in the number of air travelers categorized as infectious with SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2; the virus that causes COVID-19) in the context of total US COVID-19 vaccinations administered, and overall case counts of SARS-CoV-2 in the United States. Methods. We searched the Quarantine Activity Reporting System (QARS) database for travelers with inbound international or domestic air travel, a positive SARS-CoV-2 lab result, and a surveillance categorization of SARS-CoV-2 infection reported during January 2020 to December 2021. Travelers were categorized as infectious during travel if they had arrival dates from 2 days before to 10 days after symptom onset or a positive viral test. Results. We identified 80 715 persons meeting our inclusion criteria; 67 445 persons (83.6%) had at least 1 symptom reported. Of 67 445 symptomatic passengers, 43 884 (65.1%) reported an initial symptom onset date after their flight arrival date. The number of infectious travelers mirrored the overall number of US SARS-CoV-2 cases. Conclusions. Most travelers in the study were asymptomatic during travel, and therefore unknowingly traveled while infectious. During periods of high community transmission, it is important for travelers to stay up to date with COVID-19 vaccinations and consider wearing a high-quality mask to decrease the risk of transmission. (Am J Public Health. 2023;113(8):904–908. https://doi.org/10.2105/AJPH.2023.307325 )

Public, Environmental & Occupational Health↗

Oxygen isotope evidence for input of magmatic fluids and precipitation of Au-Ag-tellurides in an otherwise ordinary adularia-sericite epithermal system in NE China

Abstract Tellurium-rich (Te) adularia-sericite epithermal Au-Ag deposits are an important current and future source of precious and critical metals. However, the source and evolution of ore-forming fluids in these deposits are masked by traditional bulk analysis of quartz oxygen isotope ratios that homogenize fine-scale textures and growth zones. To advance understanding of the source of Te and precious metals, herein, we use petrographic and cathodoluminescence (CL) images of such textures and growth zones to guide high spatial resolution secondary ion mass spectroscopy (SIMS) oxygen isotope analyses (10 µm spot) and spatially correlated fluid inclusion microthermometric measurements on successive quartz bands in contemporary Te-rich and Te-poor adularia-sericite (-quartz) epithermal Au-Ag vein deposits in northeastern China. The results show that large positive oxygen isotope shifts from –7.1 to +7.7‰ in quartz rims are followed by precipitation of Au-Ag telluride minerals in the Te-rich deposit, whereas small oxygen isotope shifts of only 4‰ (–2.2 to +1.6‰) were detected in quartz associated with Au-Ag minerals in the Te-poor deposits. Moreover, fluid-inclusion homogenization temperatures are higher in comb quartz rims (avg. 266.4 to 277.5 °C) followed by Au-Ag telluride minerals than in previous stages (~250 °C) in the Te-rich deposit. The Te-poor deposit has a consistent temperature (~245 °C) in quartz that pre- and postdates Au-Ag minerals. Together, the coupled increase in oxygen isotope ratios and homogenization temperatures followed by precipitation of Au-Ag tellurides strongly supports that inputs of magmatic fluid containing Au, Ag, and Te into barren meteoric water-dominated flow systems are critical to the formation of Te-rich adularia-sericite epithermal Au-Ag deposits. In contrast, Te-poor adularia-sericite epithermal Au-Ag deposits show little or no oxygen isotope or fluid-inclusion evidence for inputs of magmatic fluid.

Geochemistry & Geophysics↗

Engineering a pure Dirac regime in ZrTe$_5$

Real-world topological semimetals typically exhibit Dirac and Weyl nodes that coexist with trivial Fermi pockets. This tends to mask the physics of the relativistic quasiparticles. Using the example of ZrTe _5 5 , we show that strain provides a powerful tool for in-situ tuning of the band structure such that all trivial pockets are pushed far away from the Fermi energy, but only for a certain range of Van der Waals gaps. Our results naturally reconcile contradicting reports on the presence or absence of additional pockets in ZrTe _5 5 , and provide a clear map of where to find a pure three-dimensional Dirac semimetallic phase in the structural parameter space of the material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Whole program Adaptive Error Detection and Mitigation

Our project investigated methods to detect soft errors in computing systems. Such detection schemes must have low overheads and also generate no false positives. Our solutions focused on control-space error detection based on changing addressing schemes so that faults tend to cascade – rather than being masked. Our solutions also addressed data-space error detection by synthesizing error detectors based on rigorous floating-point error analysis.

42 ENGINEERING↗

Bat Impact Minimization Technology: An Improved Bat Deterrent for the Full Swept Rotor Area of Any Wind Turbine

The growth in the number of wind turbine generators has led to a significant number of fatal interactions with bat species. The need to reduce the number of bat fatalities while minimizing power losses is the greatest conservation challenge for wind energy development in parts of the country, according to the American Wind Wildlife Institute. Technological solutions that can also allow turbines to operate normally would generate the maximum electricity and avoid financial losses. Bats use echolocation to perceive their surroundings by listening to features of echoes from their high frequency vocal signals reflecting from targets. In this project, Frontier Wind built on previous research demonstrating that ultrasonic noise can mask echolocation and act as a repellent or deterrent to bat flight activity. Whereas the initial study only broadcast ultrasonic transmissions from the center of the turbine, the Strike Free™ system developed for this project extended the ultrasonic coverage to the entire area swept by the turbine blades. Frontier Wind designed the system components and their integration and then tested them in the lab and in the field at Pattern Energy’s Hatchet Ridge Wind Facility near Redding, California. The researchers used an acoustic model to determine the optimal configuration of transmitters along the blades to provide sound transmission coverage across the turbine rotor swept area volume. The custom ultrasonic transmitters were designed specifically for the echolocation frequencies of the four main bat species that have been shown to have died at Hatchet Ridge, although the transmitters can be customized for different frequencies as needed in other geographic locations. The Strike Free™ system shows promise for reducing bat fatalities, and the path to commercialization requires further testing to validate and optimize performance in the field.

17 WIND ENERGY↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Uncertainty analysis of Resource Demand Model for Covid-19

As part of the Department of Energy response to the novel coronavirus pandemic of 2020, a modeling effort was sponsored by the DOE Office of Science. One task of this modeling effort at Sandia was to develop a model to predict medical resource needs given various patient arrival scenarios. Resources needed include personnel resources (nurses, ICU nurses, physicians, respiratory therapists), fixed resources (regular or ICU beds and ventilators), and consumable resources (masks, gowns, gloves, face shields, sedatives). This report documents the uncertainty analysis that was performed on the resource model. The uncertainty analysis involved sampling 26 input parameters to the model. The sampling was performed conditional on the patient arrival streams that also were inputs to the model. These patient arrival streams were derived from various epidemiology models and had a significant effect on the projected resource needs. In this report, we document the sampling approach, the parameter ranges used, and the computational workflow necessary to perform large-scale uncertainty studies for every county and state in the United States.

59 BASIC BIOLOGICAL SCIENCES↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applicability for MELCOR Accident Code System (MACCS) to Model the Atmospheric Transport of Biological Contaminants

Characterization of airborne transmission behavior for biological contaminants is a critical aspect in developing public health guidelines in the event of an outbreak. Guidelines such as safe separation distances and physical protections (mask and face-shields) are heavily influenced by the particular biological airborne transmission risk, which depends on a multitude of factors and is not easily or readily determined, therefore potentially lagging behind the time sensitive need to inform effective public health guidelines. Herein is proposed a means to leverage the substantial investment over the last three decades of the Nuclear Regulatory Commission in the MACCS code suite developed at Sandia National Laboratories. This work includes augmenting the MACCS code to represent biological rather than radioactive contaminants in the atmosphere, therefore characterizing the airborne transmission risk for such contaminants and helping to inform critical and time sensitive public health guidelines.

54 ENVIRONMENTAL SCIENCES↗

Practices Implemented by DOE Better Plants Program Partners to Mitigate COVID-19

Screening for symptoms, maintaining physical distance, sanitizing surfaces, wearing appropriate face masks, maintaining good personal hygiene, and reconfiguring HVAC air management are the major activities that the DOE BP partners have implemented to mitigate COVID-19. This article shares some specific practices that BP program partners have implemented for these activities. The energy impact of some practices has also been discussed and some rules of thumb have been provided to estimate energy penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CONFIDANTE Demonstration Prototype Report

This report summarizes design optimization and performance evaluation studies for a new prototype CONFIDANTE (CONfirmation using a Fast-neutron Imaging Detector with Anti-image Null-positive Time Encoding) warhead confirmation system. It was found that a spherical mask geometry and a 2” diameter cylindrical central detector is expected to best discriminate between the parametrically varied source distributions that were evaluated. The optimized design as fabricated and its performance was evaluated in a series of laboratory measurements. The performance was in good agreement with the design studies, with demonstrated discrimination between objects with differences in scale on the order of 5 centimeters or better at 1 meter stand-off

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer Learning using Denoising Auto-Encoders for Cellular-Level Annotation of Tumor in Pathology Slides

Adversarial examples can produce altered classifications using only seemingly innocuous, imperceptible perturbations to the original image. The imperceptibility of adversarial perturbations suggests that the corresponding classifiers use decision criteria different than those of a human. In a medical setting, inexplicable decision criteria confound a pathologist’s willingness to trust machine-generated annotations. Here, we analyze denoising tumor detection models to see if they are robust to imperceptible adversarial perturbations. Moreover, to be more fully trusted by pathologists, we require tumor detectors that generate interpretable annotations which segment pathology slides into tumorous and normal regions at the cellular level. We therefore compare transfer learning based on two different autoencoder architectures, one derived from a deep denoising bottleneck autoencoder and one from an over-complete sparse autoencoder. Both autoencoders were first trained in an unsupervised manner on a set of pathology slides drawn from the Camelyon16 dataset. The latent representations produced by each autoencoder were then passed to separate neural networks that were trained in a supervised manner on binary tumor-normal masks generated by pathologists at cellular resolution. Both tumor detectors supported better than 90% AUC PR as measured by the area under the precision/recall curve on a held-out pathology slide. To assess the underlying decision criteria used by both tumor detectors, we constructed imperceptible adversarial examples which reduced the AUC PR of both models to less than 70%. Random noise of the same amplitude had almost no effect on the AUC PR of either model. Additionally, each tumor detector was resistant to adversarial “transfer” attacks targeting the other. The adversarial perturbations showed strong characteristic differences: the deep denoising models perturbations were a very diffuse, seemingly unrecognizable pattern while the sparse coding models perturbations showed traces of tissue cells.

47 OTHER INSTRUMENTATION↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Spatially and Temporally Resolved Velocimetry for Hypersonic Flows

The development of new hypersonic flight vehicles is limited by the physical understanding that may be obtained from ground test facilities. This has motivated the present development of a temporally and spatially resolved velocimetry measurement for Sandia National Laboratories (SNL) Hypersonic Wind Tunnel (HWT) using Femtosecond Laser Electronic Excitation Tagging (FLEET). First, a multi-line FLEET technique has been created for the first time and tested in a supersonic jet, allowing simultaneous measurements of velocities along multiple profiles in a flow. Secondly, two different approaches have been demonstrated for generating dotted FLEET lines. One employs a slit mask pattern focused into points to yield a dotted line, allowing for two- or three-component velocity measurements free of contamination between components. The other dotted-line approach is based upon an optical wedge array and yields a grid of points rather than a dotted line. Two successful FLEET measurement campaigns have been conducted in SNL’s HWT. The first effort established optimal diagnostic configurations in the hypersonic environment based on earlier benchtop reproductions, including validation of the use of a 267 nm beam to boost the measurement signal-to-noise ratio (SNR) with minimal risk of perturbing the flow and greater simplicity than a comparable resonant technique at 202 nm. The same FLEET system subsequently was reconstituted to demonstrate the ability to make velocimetry measurements of hypersonic turbulence in a realistic flow field. Mean velocity profiles and turbulence intensity profiles of the shear layer in the wake of a hypersonic cone model were measured at several different downstream stations, proving the viability of FLEET as a hypersonic diagnostic.

33 ADVANCED PROPULSION SYSTEMS↗