Design, construction, and testing of no-insulation small subscale solenoids for compact tokamaks

Fusion energy systems studies (FESS) for next-step devices based on the most promising magnetic configurations indicate that high magnetic fields and high current density for magnet coil systems may reduce device size and lower the cost. High current density and radiation resistant fusion magnets are particularly beneficial for low cost, low aspect ratio compact reactor designs such as Fusion Nuclear Science Facility (FNSF), Fusion Pilot Plant (FPP) of low-aspect ratio spherical tokamak (ST) or compact stellarators. Unlike typical high field magnets for nuclear magnetic resonance (NMR), magnetic resonance imaging (MRI), or high energy physics research applications, neutron irradiation damage to organic insulations in the coil winding pack is a critical issue for next generation fusion reactors where orders of magnitude higher neutron fluence than those in present experimental reactors such as ITER are expected. Moreover, a high coil winding pack current density is needed for high field magnets in low cost, compact radial build next step fusion reactors. The slow current charging time, however, is an issue in fully non-insulated coils. In this work, we present the design, construction and testing of subscale Nb3Sn solenoids, up to half the diameter of the central solenoid (CS) for National Spherical Torus Experiment (NSTX), with and without inter-layer insulation for enhancing radiation resistance while improving the winding pack current density and coil performance. The major radius for the NSTX/NSTX-Upgrade (reference for compact ST) is 0.854/0.934 meter, and 4.8 meters for FNSF. The magnetic field for NSTX/NSTX-U at the plasma center is 0.6/1 Tesla and 9 Tesla for FNSF. The inner diameter of the central solenoid coil is 0.2/0.4 meter for NSTX/NSTX-U and 1.2 meters for FNSF. The current charging and discharging behavior of the prototype solenoids was investigated to quantify performance advantages of a simplified coil fabrication without error-prone vacuum pressure impregnation (VPI) for the removal of epoxy organic insulation. Scalability of the no insulation concept for fusion can be addressed via engineered coating for novel insulation on contact resistance or intra-layer no insulations. Radiation resistance and coil winding efficiency were significantly improved in the no insulation coils for next step compact fusion reactors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect Laws of Different Factors on Levitation Characteristics of High-T{sub c} Superconducting Maglev System with Numerical Solutions

The interaction between the high-temperature superconducting (HTS) bulk and permanent magnet guideway (PMG) has been a topic among the existing HTS magnetic levitation systems. Up to now, the theories about the electromagnetic and force characteristics have been relatively consummated. Here, using the finite element model by COMSOL Multiphysics 5.3a, we investigated the impact of the intrinsic and external factors on the levitation characteristics of HTS maglev systems, the application laws are concluded. Factors including the critical current density and geometric dimensions of the bulk superconductor, as well as the moving velocity, are discussed. The effects of the multiple back and forth movements are also analyzed. By comparing calculation results of the distributions of the induced current and the levitation force of the bulk superconductor, we can clearly confirm the effect laws of various factors on the electromagnetic characteristics and levitation force. These observations support the physical parameters that are difficult to be tested by experiments. And they also have a significant contribution to the experimental condition selections and optimization of the high-temperature superconducting magnetic levitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A sufficient condition for the stability of atmospheres with magnetic fields

Using the MHD energy principle, it is shown that P + B sq/8 x pi = constant is a sufficient condition for the stability of magnetized fluid systems with the following properties: the gravitational acceleration g is uniform, the magnetic field lines lie in parallel planes aligned with g, and all quantities are uniform in the direction perpendicular to the plane of the field lines. An example of a stable system is given, consisting of a vertical sheet of plasma supported against gravity by bowed field lines.

Zweibel, E. G.↗

Simple correction for the sample shape and radial offset effects on SQUID magnetometers: Magnetic measurements on Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er) standards

An increased focus on magnetic measurements of oriented single crystals, thin films, and magnetically dilute systems has led to a demand for the measurement of weak magnetic moments. This level of sensitivity and precision can be achieved on SQUID magnetometers by decreasing the size of the detection coils. However, the smaller detection coils can amplify two errors in the magnitude of the measured moment, the sample shape and radial offset effects, which were small and typically unaccounted for on previous magnetometers. We report a simple method to determine the radial offset of a sample by taking advantage of the two basic scan modes, DC and lock-in, typically used on magnetometers. This technique allows for the correction of the sample shape and radial offset effects in order to obtain the true moment of a sample. To show the efficacy of this technique, we report the magnetic properties of Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er). - Graphical abstract: Correction for the sample shape and radial offset effects on SQUID magnetometers using a combination of DC and VSM scan data. - Highlights: • Sample shape and radial offset effects alter the moment measured by magnetometers. • We present a simple method to correct for these sample effects on magnetometers. • We measure magnetic susceptibilities of Ln{sub 2}O{sub 3} to show the efficacy of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermo-magneto coupling in a dipole plasma

We observe the generation of a magnetic moment in a dipole plasma as a levitating magnet-plasma system moves in response to electron cyclotron heating and increasing {beta} (magnetically confined thermal energy). We formulate a thermodynamic model that interprets heating as injection of microscopic magnetic moments; the corresponding chemical potential is the ambient magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle Acceleration and Pitch-angle Evolution in Relativistic Turbulence

Synchrotron radiation detected from relativistic astrophysical objects such as pulsar-wind nebulae and jets from active galactic nuclei depends on the magnetic fields and the distribution functions of energetic electrons in these systems. Relativistic magnetically dominated turbulence has been recognized as an efficient mechanism for structure formation and nonthermal particle acceleration in these environments. Recent numerical simulations of relativistic turbulence have provided insights into the energy distribution functions of accelerated electrons. Much less is currently understood about their pitch angle distributions, which are crucial for accurately interpreting the spectra of synchrotron radiation. We perform a detailed case study of the pitch angle distributions formed during the process of turbulent acceleration for B 0 /δB 0 = 10 and $\tilde{σ}$ 0 ~40, where B0 is the uniform component of the magnetic field, δB0 is the fluctuating component, and $\tilde{σ}$ 0 is the plasma magnetization based on the magnetic fluctuations. We find that even minimal numerical noise can cause substantial pitch angle scattering, but we demonstrate techniques for overcoming the numerical challenges associated with the evolution of very small pitch angles. Our numerical results are consistent with the phenomenological considerations found in C. Vega et al. (2024a, 2025).

79 ASTRONOMY AND ASTROPHYSICS↗

Long-time variation in magnetic structure of Ce(Ir x Rh 1– x ) 3 Si 2 : A new interpretation of time variation

Here, to clarify the key factor for the slow magnetic transitions in CeIr 3 Si 2 and other materials, magnetization and neutron scattering measurements have been carried out on the system Ce(Ir x Rh 1–x ) 3 Si 2 . In this system, a magnetic phase transition is accomplished through slow and fast processes. The fractions of these processes vary with the chemical composition x . A new interpretation of magnetic phase transitions, which includes the coexistence of two processes, is presented.

36 MATERIALS SCIENCE↗

Operando nuclear magnetic resonance rotor insert

A magic angle sample spinning nuclear magnetic resonance system including a housing, a cryogenic fluid in the housing, a magnet in the housing, a probe in the housing, a magic angle sample spinning insert in the probe, a sample battery in the magic angle sample spinning insert, a photovoltaic cell in the magic angle sample spinning insert wherein the photovoltaic cell is connected to the sample battery, an optic fiber operatively connected to the photovoltaic cell, and a laser operatively connected to the optic fiber wherein the laser provides power to charge the sample battery during the magic angle sample spinning nuclear magnetic resonance.

Marple, Maxwell↗

A Comparison Study of Magnetic Bearing Controllers for a Fully Suspended Dynamic Spin Rig

NASA Glenn Research Center (GRC) has developed a fully suspended magnetic bearing system for the Dynamic Spin Rig (DSR) that is used to perform vibration tests of turbomachinery blades and components under spinning conditions in a vacuum. Two heteropolar radial magnetic bearings and a thrust bearing and the associated control system were integrated into the DSR to provide noncontact magnetic suspension and mechanical excitation of the 35 lb vertical rotor with blades to induce turbomachinery blade vibration. A simple proportional-integral-derivative (PID) controller with a special feature for multidirectional radial excitation worked very well to both support and shake the shaft with blades. However, more advanced controllers were developed and successfully tested to determine the optimal controller in terms of sensor and processing noise reduction, smaller rotor orbits, and energy savings for the system. The test results of a variety of controllers we demonstrated up to the rig's maximum allowable speed of 10,000 rpm are shown.

Choi, Benjamin↗

The influence of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation

The influences of electron discharge and magnetic field on calcium carbonate (CaCO{sub 3}) precipitation in water have been successfully investigated. The study used three pairs of magnetic field 0.1 T whilst the electron discharge was generated from television flyback transformer type BW00607 and stainless steel SUS 304 as an electrode. The water sample with an initial condition of 230 mg/L placed in the reactor with flow rate 375 mL/minutes, result showed that the electron discharge can be reduced contain of calcium carbonate the water sample around 17.39% within 2 hours. Meanwhile for the same long period of treatment and flow rate, around 56.69% from initial condition of 520 mg/L of calcium carbonate in the water sample can be achieved by three pairs of magnetic field 0.1 T. When the combination of three pairs of magnetic field 0.1 T and the electron discharge used for treatment, the result showed that the combination of electron discharge and magnetic field methods can be used to precipitate calcium carbonate in the water sample 300 mg/L around 76.66% for 2 hours of treatment. The study then investigated the influence of the polar position of the magnetic field on calcium carbonate precipitation. Two positions of magnetic field were tested namely the system with alternated polar magnetics and the system without inversion of the polar magnetics. The influence of the polar position showed that the percentage reduction in levels of calcium carbonate in the water sample (360 mg/L) is significant different. Result showed that the system without inversion of the polar magnetics is generally lower than the system with alternated polar magnetics, with reduction level at 30.55 and 57.69%, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a Large 5 T Superconducting Magnet for Polarized Target for JLAB Hall B 12 GeV Upgrade Clas12 Detector

Hall B at Jefferson Laboratory (JLAB) will need a 5 T, 78 cm bore polarized target magnet with a field uniformity of {Delta}B/B{sub 0} <; 10{sup -4} in a useful cylinder of the dimensions 0.04 m long x 0.02 m in diameter. The large magnet is designed with a superconducting coil that provides the solenoid with nearly perfect self shielding in order to reduce the fringe field at nearby photo multiplier tubes (PMTs) to less than 3.5 mT. Because the solenoid is also very close to the Clas12 Torus, the nearly perfect shielding provided by the self shielded solenoid greatly reduces force, field, and torque interactions with the six-coil Torus magnet. The solenoid coil consists of 18 coil modules which are made of coils mounted in aluminum plate discs. Each coil module consists of dual double pancake coils with main coils and shield coil partitioned into separate winding cavities in the aluminum plate discs to distribute and reduce radial hoop load and radial coil forces. Each coil module is effectively an enclosed aluminum box and this serves to partition the axial load and thus reduces coil axial forces. Since overall coil forces within each coil module are reduced, this will greatly reduce the number coil training quenches. This is a very important consideration for this solenoid coil because the coil cooling is adiabatic, using in-direct conduction cooling by 4.5 K supercritical helium, which will provide only a relatively small temperature stability margin. Super critical helium is used as per JLAB specification. Detail design of the coil structure, coil assembly, cold mass, and cryogenic control will be presented. The magnet protection system shall be capable of the following features: (1) quench and fault detection, (2) fast discharge of the magnet, (3) limit fault voltages to safe values, (4) monitor interlock signals to prevent unsafe operation, and (5) provide control logic necessary for safe operation of the solenoid. The instrument systems shall be capable of the following features: (1) monitors and display temperatures within the solenoid magnet, (2) measure loads or stress on the magnet suspension, (3) monitor voltages within the solenoid magnet and charging bus, (4) monitor pressures and (5) use data logging system to save all sensor data. These systems will be described and a quench analysis presented.

43 PARTICLE ACCELERATORS↗

System identification of the Large-Angle Magnetic Suspension Test Facility (LAMSTF)

The Large-Angle Magnetic Suspension Test Facility (LAMSTF), a laboratory-scale research project to demonstrate the magnetic suspension of objects over wide ranges of attitudes, has been developed. This system represents a scaled model of a planned Large-Gap Magnetic Suspension System (LGMSS). The LAMSTF system consists of a planar array of five copper electromagnets which actively suspend a small cylindrical permanent magnet. The cylinder is a rigid body and can be controlled to move in five independent degrees of freedom. Five position variables are sensed indirectly by using infra-red light-emitting diodes and light-receiving phototransistors. The motion of the suspended cylinder is in general nonlinear and hence only the linear, time-invariant perturbed motion about an equilibrium state is considered. One of the main challenges in this project is the control of the suspended element over a wide range of orientations. An accurate dynamic model plans an essential role in controller design. The analytical model of the LAMSTF system includes highly unstable real poles (about 10 Hz) and low-frequency flexible modes (about 0.16 Hz). Projection filters are proposed to identify the state space model from closed-loop test data in time domain. A canonical transformation matrix is also derived to transform the identified state space model into the physical coordinate. The LAMSTF system is stabilized by using a linear quadratic regulator (LQR) feedback controller. The rate information is obtained by calculating the back difference of the sensed position signals. The reference inputs contain five uncorrelated random signals. This control input and the system reponse are recorded as input/output data to identify the system directly from the projection filters. The sampling time is 4 ms and the model is fairly accurate in predicting the step responses for different controllers while the analytical model has a deficiency in the pitch axis.

Huang, Jen-Kuang↗

SU-F-T-409: Modelling of the Magnetic Port in Temporary Breast Tissue Expanders for a Treatment Planning System

Purpose: To model the magnetic port in the temporary breast tissue expanders and to improve accuracy of dose calculation in Pinnacle, a commercial treatment planning system (TPS). Methods: A magnetic port in the tissue expander was modeled with a radiological measurement-basis; we have determined the dimension and the density of the model by film images and ion chamber measurement under the magnetic port, respectively. The model was then evaluated for various field sizes and photon energies by comparing depth dose values calculated by TPS (using our new model) and ion chamber measurement in a water tank. Also, the model was further evaluated by using a simplified anthropomorphic phantom with realistic geometry by placing thermoluminescent dosimeters (TLD)s around the magnetic port. Dose perturbations in a real patient’s treatment plan from the new model and a current clinical model, which is based on the subjective contouring created by the dosimetrist, were also compared. Results: Dose calculations based on our model showed less than 1% difference from ion chamber measurements for various field sizes and energies under the magnetic port when the magnetic port was placed parallel to the phantom surface. When it was placed perpendicular to the phantom surface, the maximum difference was 3.5%, while average differences were less than 3.1% for all cases. For the simplified anthropomorphic phantom, the calculated point doses agreed with TLD measurements within 5.2%. By comparing with the current model which is being used in clinic by TPS, it was found that current clinical model overestimates the effect from the magnetic port. Conclusion: Our new model showed good agreement with measurement for all cases. It could potentially improve the accuracy of dose delivery to the breast cancer patients.

60 APPLIED LIFE SCIENCES↗

An innovative tri-directional broadband piezoelectric energy harvester

This paper presents a tri-directional piezoelectric energy harvester that is able to harvest vibration energy over a wide bandwidth from three orthogonal directions. The harvester consists of a main beam, an auxiliary beam, and a spring-mass system, with magnets integrated to introduce nonlinear force and couple the three sub-systems. Theoretical analysis and experiments were performed at constant acceleration under frequency sweeps to acquire frequency responses. The experimental results show that the voltage can achieve more than 2 V over more than 5 Hz of bandwidth with 1 MΩ load in the three orthogonal directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the beam extraction synchronization system at the Fermilab Booster

The new beam extraction synchronization control system called “Magnetic Cogging” was developed at the Fermilab Booster and it replaces a system called “RF Cogging” as part of the Proton Improvement Plan (PIP). [1] The flux throughput goal for the PIP is 2.2×10 17 protons per hour, which is double the present flux. Thus, the flux increase will be accomplished by doubling the number of beam cycles which, in turn, will double the beam loss in the Booster accelerator if nothing else is done.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural and magnetic properties of Y-doped La{sub 0.5}Sr{sub 0.5}MnO{sub 3} manganite system: Evidence of step-like magnetization

The magnetic and transport properties of bulk doped manganite, La{sub 0.5−y}Y{sub y}Sr{sub 0.5}MnO{sub 3} have been studied as a function of yttrium doping, y, for 0 ≤ y ≤ 0.25. In the absence of the yttrium this is a well studied half-doped manganite which is a metallic ferromagnet. The end members of this system (with y = 0 and 0.25) are found to be structurally different (rhombohedral and orthorhombic, respectively) due to the large distortions caused by the yttrium. These distortions make this series of compounds particularly interesting. The magnetization obtained in zero field cooled (ZFC) and field cooled (FC) studies show dramatic changes as the value of y is raised above 0.05. The magnetic behavior is further investigated by a study of the hysteresis loops, frequency dependent susceptibility and studies of the magnetic relaxation. The results are understood in terms of the average size of the cation on the A site, , and the variance, σ{sup 2} (= ∑y{sub i}{sup 2}r{sub i}{sup 2} - {sup 2}). The value of the variance, σ{sup 2}, increases rapidly with doping, y, induces melting of the long range ferromagnetic ordering, exhibiting a stepwise variation of magnetization (metamagnetic like). Based on the present results a magnetic phase diagram has been drawn demonstrating different magnetic phase sequences with the variation of σ{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗