Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LUBRICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Lubricant Coating Process

"Peen Plating," a NASA developed process for applying molybdenum disulfide, is the key element of Techniblast Co.'s SURFGUARD process for applying high strength solid lubricants. The process requires two machines -- one for cleaning and one for coating. The cleaning step allows the coating to be bonded directly to the substrate to provide a better "anchor." The coating machine applies a half a micron thick coating. Then, a blast gun, using various pressures to vary peening intensities for different applications, fires high velocity "media" -- peening hammers -- ranging from plastic pellets to steel shot. Techniblast was assisted by Rural Enterprises, Inc. Coating service can be performed at either Techniblast's or a customer's facility.

Source record↗

Thermal Effects on a Low Cr Modification of PS304 Solid Lubricant Coating

PS304 is a high temperature composite solid lubricant coating composed of Ni-Cr, Cr2O3, BaF2-CaF2 and Ag. The effect of reducing chromium content on the formation of voids in the Ni-Cr particles after heat treatment in PS304 coating was investigated. Coatings were prepared with Ni-20Cr or Ni-10Cr powder and in various combinations with the other constituents of PS304 (i.e., chromia, silver and eutectic BaF2-CaF2 powders) and deposited on metal substrates by plasma spray. Specimens were exposed to 650 C for 24 hr or 1090 C for 15 hr and then examined for changes in thickness, coating microstructure and adhesion strength. Specimens with Ni-10Cr generally had less thickness increase than specimens with Ni-20Cr, but there was great variance in the data. Reduction of chromium concentration in Ni-Cr powder tended to reduce the appearance of voids in the Ni-Cr phase after heat exposure. The presence of BaF2-CaF2 resulted in a significant increase in coating adhesion strength after heat treatment, while coatings without BaF2-CaF2 had no significant change. Chemical composition analysis suggested that the void formation was due to oxidation of chromium in the Ni-Cr constituent.

Stanford, Malcolm K.↗

Friction and Wear Characteristics of a Modified Composite Solid Lubricant Plasma Spray Coating

LCR304 is a solid lubricant coating composed of Ni-10Cr, Cr2O3, BaF2-CaF2 and Ag and developed for dimensional stability in high temperature air. This coating is a modification of PS304, which differs in that the Ni-Cr constituent contains 20wt% Cr. The tribological characteristics of LCR304 were evaluated by pin-on-disk and foil air bearing rig testing from 25 to 650 C and compared to previous test results with PS304. For both tests, the friction coefficient decreased as temperature increased from 25 to 650 C. Wear generally decreased with increasing temperature for all pin-on-disk tests. LCR304 coated components produced the least wear of Inconel X-750 counterface materials at 427 and 650 C. These results indicate that the LCR304 coating has potential as a replacement for PS304 in, for example, low cycle (minimum wear) applications where dimensional stability is imperative.

Stanford, M. K.↗

A Study of Spur Gears Lubricated With Grease-Observations From Seven Experiments

To improve understanding of gears operating with a perfluoro type space-qualified grease, seven spur gear experiments were performed. Test conditions were selected to study the influences of torque, lubricant type, and atmosphere. Two testing torques provided nominal pitch-line Hertz stresses greater and lesser than the contact stress limit as recommended by the grease manufacturer. As was expected, all tests resulted in some gear tooth wear. Discoloration of the perfluoro type grease occurred for all tests. Tests in dry nitrogen produced some dark-grey colored perfluoro type grease. Testing in either ambient or dry air produced red debris after short test duration, and for tests of longer duration large amounts of red debris, red grease, and wear were evident. Tests using higher torques produced more debris. The first indications of discoloration occurred more quickly with higher test torques. Total amounts of wear were quite significant, up to four times the profile tolerance for AGMA Class 10 gears.

Krantz, Timothy L.↗

Effect of Test Environment on Lifetime of Two Vacuum Lubricants Determined by Spiral Orbit Tribometry

The destruction rates of a perfluoropolyether (PFPE) lubricant, Krytox 143AC(TradeMark), subjected to rolling contact with 440C steel in a spiral orbit tribometer at room temperature have been evaluated as a function of test environment. The rates in ultrahigh vacuum, 0.21 3 kPa (1.6 Torr) oxygen and one atmosphere of dry nitrogen were about the same. Water vapor in the test environment - a few ppm in one atmosphere of nitrogen - reduced the destruction rate by up to an order of magnitude. A similar effect of water vapor was found for the destruction rate of Pennzane(Registered TradeMark) 2001A , an unformulated multiply alkylated cyclopentane (MAC) hydrocarbon oil.

Pepper, Stephen V.↗

Wear Behavior of Low-Cost, Lightweight TiC/Ti-6Al-4V Composite Under Fretting: Effectiveness of Solid-Film Lubricant Counterparts

The wear behavior of low-cost, lightweight 10-wt% TiC-particulate-reinforced Ti-6Al-4V matrix composite (TiC/Ti- 6Al-4V) was examined under fretting at 296, 423, and 523 K in air. Bare 10-wt% TiC/Ti-6Al-4V hemispherical pins were used in contact with dispersed multiwalled carbon nanotubes (MWNTs), magnetron-sputtered diamondlike carbon/chromium (DLC/Cr), magnetron-sputtered graphite-like carbon/chromium (GLC/Cr), and magnetron-sputtered molybdenum disulphide/titanium (MoS2/Ti) deposited on Ti-6Al-4V, Ti-48Al-2Cr-2Nb, and nickel-based superalloy 718. When TiC/Ti-6Al-4V was brought into contact with bare Ti-6Al-4V, bare Ti-48Al-2Cr-2Nb, and bare nickel-based superalloy 718, strong adhesion, severe galling, and severe wear occurred. However, when TiC/Ti-6Al-4V was brought into contact with MWNT, DLC/Cr, GLC/Cr, and MoS2/Ti coatings, no galling occurred in the contact, and relatively minor wear was observed regardless of the coating. All the solid-film lubricants were effective from 296 to 523 K, but the effectiveness of the MWNT, DLC/Cr, GLC/Cr, and MoS2/Ti coatings decreased as temperature increased.

Miyoshi, Kazuhisa↗

Carbide/fluoride/silver self-lubricating composite

A self-lubricating, friction and wear reducing composite material for use over a wide temperature spectrum from cryogenic temperature to about 900.degree. C. in a chemically reactive environment comprising silver, barium fluoride/calcium fluoride eutectic, and metal bonded chromium carbide.

Sliney, Harold E.↗

NASA PS400: A New Temperature Solid Lubricant Coating for High Temperature Wear Applications

A new solid lubricant coating, NASA PS400, has been developed for high temperature tribological applications. This plasma sprayed coating is a variant of the patented PS304 coating and has been formulated to provide higher density, smoother surface finish and better dimensional stability than PS304. PS400 is comprised of a nickel-molybdenum binder that provides strength, creep resistance and extreme oxidative and dimensional stability. Chromium oxide, silver and barium-calcium fluoride eutectic are added to the binder to form PS400.Tribological properties were evaluated with a pin-on-disk test rig in sliding contact to 650 C. Coating material samples were exposed to air, argon and vacuum at 760 C followed by cross section microscopic analysis to assess microstructure stability. Oil-Free microturbine engine hot section foil bearing tests were undertaken to assess PS400 s suitability for hot foil gas bearing applications. The preliminary results indicate that PS400 exhibits tribological characteristics comparable to the PS304 coating but with enhanced creep resistance and dimensional stability suitable for demanding, dynamic applications.

DellaCorte, C.↗

Effect of Test Environment on Lifetime of Two Vacuum Lubricants Determined by Spiral Orbit Tribometry

The destruction rates of a perfluoropolyether (PFPE) lubricant, Krytox 143AC, subjected to rolling contact with 440C steel in a spiral orbit tribometer at room temperature have been evaluated as a function of test environment. The rates in ultrahigh vacuum, 0.213 kPa (1.6 torr) oxygen and one atmosphere of dry nitrogen were about the same. Water vapor in the test environment-a few ppm in one atmosphere of nitrogen-reduced the destruction rate by up to an order of magnitude. A similar effect of water vapor was found for the destruction rate of Pennzane 2001A, an unformulated multiply alkylated cyclopentane (MAC) hydrocarbon oil.

Pepper, Stephen V.↗

Dry Lubricant Smooths the Way for Space Travel, Industry

Reviving industry standards for coating parts in tungsten disulfide, a dry lubricant developed for the Mariner space probes managed by the Jet Propulsion Laboratory in the 1960s and '70s, Applied Tungstenite, a relatively new Temecula, California-based company, has found a client base in the mushrooming commercial space industry, as well as other manufacturers.

Source record↗

A Solid Film Lubricant Composition for Use at High Sliding Velocities in Liquid Nitrogen

Solid-lubricant-containing compositions can be of value as films and solid bodies for bearing and seal surfaces in low-temperature liquefied gases. An experimental composition including polytetrafluoroethylene (PTFE), an epoxy resin, and lithium-alumina-silicate was studied in friction, wear, and endurance experiments in liquid nitrogen (−320 F). This composition was formulated to approximate the thermal expansion of metals used in cryogenic systems. Hemisphere (3/6-in. radius) rider specimens were used and in most experiments the load was 1000 g. Films (0.005-in. thick) on disk specimens gave good endurance life, low rider wear, and desirable friction (f = 0.02 to 0.07). They functioned at a higher sliding velocity (no failure at 16, 000 ft/min) with copper rider specimens than with stainless steel riders (failure at 9000 ft/min). Solid rider material of the experimental composition had good friction and wear properties at sliding velocities above 4000 ft/min. It is important to use the experimental composition with mating materials having good thermal conductivity.

Wisander, D. W.↗

Hybrid Gear Performance Under Loss-of-Lubrication Conditions

Hybrid composite gear technology is being investigated to increase power density in rotorcraft drive systems. These gears differ from conventional steel gears in that the structural web material is replaced with a lightweight carbon fiber composite. Past studies have focused on performance of this technology under normal operating conditions, however, for this technology to be viable it must also withstand adverse conditions. The study presented here evaluates the performance of hybrid gears under loss-of-lubrication conditions in NASA Glenn Research Centers Contact Fatigue Test Facility. Two experiments are presented using small-scale 3.5 inch (8.9 cm) pitch diameter hybrid gears and compared to a baseline steel gear pair. Results of these tests show that there are limitations to the use of a hexagonal interlock pattern between the steel and composite. There is also evidence that the presence of polymer in the gear during an oil out event has a potential to increase time to failure. Further studies are planned to expand on these initial findings.

Gearbox↗

Hybrid Gear Performance Under Loss-of-Lubrication Conditions

Hybrid composite gear technology is being investigated to increase power density in rotorcraft drive systems. These gears differ from conventional steel gears in that the structural web material is replaced with a lightweight carbon fiber composite. Past studies have focused on performance of this technology under normal operating conditions, however, for this technology to be viable it must also withstand adverse conditions. The study presented here evaluates the performance of hybrid gears under loss-of-lubrication conditions in NASA Glenn Research Centers Contact Fatigue Test Facility. Two experiments are presented using small-scale 3.5 inch (8.9 cm) pitch diameter hybrid gears and compared to a baseline steel gear pair. Results of these tests show that there are limitations to the use of a hexagonal interlock pattern between the steel and composite. There is also evidence that the presence of polymer in the gear during an oil out event has a potential to increase time to failure. Further studies are planned to expand on these initial findings.

Gearbox↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Renewable Fuels and Lubricants Laboratory (Fact Sheet)

This fact sheet describes the Renewable Fuels and Lubricants (ReFUEL) Laboratory at the U.S. Department of Energy National Renewable Energy Laboratory (NREL) is a state-of-the-art research and testing facility for advanced fuels and vehicles. Research and development aims to improve vehicle efficiency and overcome barriers to the increased use of renewable diesel and other nonpetroleum-based fuels, such as biodiesel and synthetic diesel derived from biomass. The ReFUEL Laboratory features a chassis dynamometer for vehicle performance and emissions research, two engine dynamometer test cells for advanced fuels research, and precise emissions analysis equipment. As a complement to these capabilities, detailed studies of fuel properties, with a focus on ignition quality, are performed at NREL's Fuel Chemistry Laboratory.

09 BIOMASS FUELS↗