Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The formation of helioseismology lines. III - Partial redistribution effects in weak solar resonance lines

This paper investigates the formation of the Na I D2, K I 769.9 nm and Ba II 455.4 nm resonance lines in the solar atmosphere allowing for partial frequency redistribution (PRD). We show that the influence of PRD is negligible on the solar disk in all three lines for a model of the average quiet-Sun, and even for the more extreme case of a model with a steeper photospheric temperature decline. At the solar limb PRD does affect the intensity profile of the Na I and Ba II resonance lines, but not that of the K I line. Finally, we find that effects of PRD are more pronounced at the limb in the Na I D2 and Ba II 455.4 nm lines when the photospheric temperature gradient is steep.

Uitenbroek, H.↗

Regional changes in muscle mass following 17 weeks of bed rest

This work reports on the muscle loss and recovery after 17 wk of continuous bed rest and 8 wk of reambulation in eight normal male volunteers. Muscle changes were assessed by urinary levels of 3-methylhistidine (3-MeH), nitrogen balance, dual-photon absorptiometry (DPA), magnetic resonance imaging (MRI), and isokinetic muscle performance. The total body lean tissue loss during bed rest calculated from nitrogen balance was 3.9 +/- 2.1 kg. Although the total loss is minimal, DPA scans showed that nearly all of the lean tissue loss occurred in the lower limbs. Similarly, MRI muscle volume measurements showed greater percent loss in the limbs relative to the back muscles. MRI, DPA, and nitrogen balance suggest that muscle atrophy continued throughout bed rest with rapid recovery after reambulaton. Isokinetic muscle strength decreased significantly in the thigh and calf with no loss in the arms and with rapid recovery during reambulation.

Leblanc, Adrian D.↗

Spatial power-spectra from Yohkoh soft X-ray images

We analyze three sequences of images from active regions, and a full disk image obtained by Yohkoh's Soft X-ray Telescope. Two sequences are from a region at center disk observed through different filters, and one sequence is from the limb. After Fourier-transforming the X-ray intensity of the images we find nearly isotropic power-spectra with an azimuthally integrated slope of -2.1 for the center disk, and -2.8 for the limb images. The full-disk picture yields a spectrum of -2.4. These results are different from the active region spectra obtained with the Normal Incidence X-ray Telescope which have a slope of the order of -3.0, and we ascribe this to the difference in temperature response between the instruments. However, both the SXT and NIXT results are consistent with coronal heating as the end result of a downward quasistatic cascade (in lengthscales) of free magnetic energy in the corona, driven by footpoint motions in the photosphere.

Martens, Petrus C. H.↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the far infrared region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 101/cm (99 microns). The instrumental concept and atmospheric measurements are discussed.

Pickett, H. M.↗

Evidence for a spatially extended component of gamma rays from solar flares

We present gamma-ray measurements of a large solar flare that occurred beyond the western solar limb on September 29, 1989. The gamma-ray spectrum shows a neutron capture line which is much stronger than predicted by limb-darkening curves that fit the measurements for flares on the visible hemisphere. We show that this strong neutron capture line can be explained if, in addition to the compact impulsive phase component that normally dominates the total fluence, there is a spatially extended component. For the September 29, 1989 flare we find that such a spatially extended region must subtend more than about 30 deg on the solar surface. We suggest that the extended component could be powered by particles that diffuse from a compact impulsive region or by particles that diffuse into the lower solar atmosphere from a large-scale acceleration site.

Vestrand, W. T.↗

An ultraviolet spectral atlas of the sun between 1190-1730 A

An ultraviolet spectral atlas of different solar regions in the wavelength region 1190-1730 A is presented. The data were obtained with the High Resolution Telescope and Spectrograph during a rocket flight in 1978. The spectral resolution of the instrument was 0.05 A while a spatial resolution of approximately 1.8 arcsec was achieved. The atlas contains spectra of three different quiet regions including pointings at disk center and the extreme limb. Data from an active region close to the solar limb and a prominence have also been included together with an atlas of a so-called explosive event. The selected areas are averaged over several arcsec, ranging from 3.5 to 220 arcsec. The absolute intensities are determined with an accuracy of +/- 30 percent except for the strongest emission lines that are synthesized from spectra with different exposure times. The atlas is available in a machine-readable form together with an IDL program to interactively measure line widths, total intensities, and solar wavelengths.

Brekke, P.↗

Balloon-borne submillimeterwave stratospheric measurements

A new remote sensing instrument, the Submillimeterwave Limb Sounder, has been developed to simultaneously measure ClO, HCl, O3 and HO2 from high altitude balloon and aircraft platforms. The instrument is a double sideband heterodyne radiometer measuring atmospheric thermal emission spectra near 640 GHz from the Earth's limb. The instrument was flown in April and October, 1991 and in February, 1992 on high altitude balloon platforms over the southwestern United States.

Stachnik, R. A.↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the FIR region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 100/cm (100 microns). It is compact and has low power and low data rate requirements so that it may be flown as an auxiliary balloon payload with larger instruments. FILOS has two 0.05/cm bandwidth channels which are currently tuned to a HCl line at 104.2/cm and a pair of OH lines at 101.3/cm. The instrument is described in further detail and results are presented from two recent balloon flights in which OH was measured as a function of time on one hour centers from sunrise to sunset.

Pickett, Herbert M.↗

Responses of large-scale coronal structures to chromospheric activity

We have followed the transit of two active regions across the western solar limb during June 29 through July 2, 1980, as imaged in 3.5-16 keV X-rays by HXIS aboard the SMM. During frequent brightenings of large-scale coronal structures, hard X-ray emission in the 11-16 keV energy band was recorded up to altitudes of 76,000 km. Soft X-rays could be seen in excess of 250,000 km altitude above the photospheric active region. Many X-ray brightenings low in the corona in the active regions were followed by enhancements high in the corona in the large-scale coronal structures. Although subsequent enhancements rarely appeared in the same position, similar portions of the corona brightened intermittently, indicating that the general configuration of the coronal structures above the active regions did not change much, in spite of the frequent energy inputs. These inputs were of two kinds: nonthermal, with very fast response at high coronal altitudes within seconds or tens of seconds, and thermal, with a delay of several minutes. The nonthermal response is short-lived, reflecting the time profile of the primary source; the thermal response is more gradual and longer lasting than the primary source. In some enhancements of large-scale coronal structures both these kinds of response occur and can be clearly recognized. There are also active-region brightenings without any response in the high corona and, vice versa, high-corona brightenings without any obvious primary source; in the latter case, it is likely that the source was hidden behind the limb.

Farnik, Frantisek↗

Six-Degree-Of-Freedom Parallel Minimanipulator

Six-degree-of-freedom parallel minimanipulator stiffer and simpler than earlier six-degree-of-freedom manipulators. Includes only three inextensible limbs with universal joints at ends. Limbs have equal lengths and act in parallel as they share load on manipulated platform. Designed to provide high resolution and high stiffness for fine control of position and force in hybrid serial/parallel-manipulator system.

Tahmasebi, Farhad↗

Galileo imaging results from the second Earth-Moon flyby: Lunar Maria and related units

The second flyby of the Earth-Moon System by Galileo occurred on December 7, 1992, on its trajectory toward Jupiter. The flyby took the spacecraft over the lunar north polar region from the dark farside and continued across the illuminated nearside. This provided the first opportunity to observe northern and northeastern limb regions with a modern, multispectral imaging system with high spatial resolution (up to 1.1 km/pixel). Scientific objectives included compositional assessment of previously uncharacterized mare regions, study of various light plains materials, and assessment of dark mantle deposits (DMD) and dark halo craters (DHC). Color composite images were prepared from ratios of Galileo SSI filter data (0.76/0.41 yields red; 0.76/0.99 yields green; 0.41/0.76 yields blue) and used for preliminary comparison of units. The 0.41/0.76 ratio has been empirically correlated to Ti content of mare soils (blue is relatively high, red is relatively low). The relative strengths of the ferrous one micron absorption in mafic minerals can be compared using the 0.76/0.99 ratio. In addition, relative ages of units analyzed spectrally were determined from crater statistics using Lunar Orbiter images following the techniques of Neukum et al. Mare deposits analyzed include Mare Humboldtianum, central and eastern Mare Frigoris, Mare Crisium and other deposits in the Crisium Basin, and isolated mare patches on the northeastern lunar limb. Preliminary results show a diversity of 0.41/0.76 micron signatures, implying a wide range of titanium contents. Some light plains units are similar to units found at the Apollo 16 site; others may be ancient mare materials. Dark mantle deposits (DMD) analyzed also are available.

Greeley, R.↗

Temperature/pressure and water vapor sounding with microwave spectroscopy

Two intense microwave spectra lines exist in the martian atmosphere that allow unique sounding capabilities: water vapor at 183 GHz and the (2-1) rotational line of CO at 230 GHz. Microwave spectra line sounding is a well-developed technique for the Earth's atmosphere for sounding from above from spacecraft and airplanes, and from below from fixed surface sites. Two simple instruments for temperature sounding on Mars (the CO line) and water vapor measurements are described. The surface sounder proposed for the MESUR sites is designed to study the boundary layer water vapor distribution and the temperature/pressure profiles with vertical resolution of 0.25 km up to 1 km with reduced resolution above approaching a scale height. The water channel will be sensitive to a few tenths of a micrometer of water and the temperature profile will be retrieved to an accuracy between 1 and 2 K. The latter is routinely done on the Earth using oxygen lines near 60 GHz. The measurements are done with a single-channel heterodyne receiver looking into a 10-cm mirror that is canned through a range of elevation angles plus a target load. The frequency of the receiver is sweep across the water and CO lines generating the two spectra at about 1-hr intervals throughout the mission. The mass and power for the proposed instrument are 2 kg and 5-8 W continuously. The measurements are completely immune to the atmospheric dust and ice particle loads. It was felt that these measurements are the ultimate ones to properly study the martian boundary layer from the surface to a few kilometers. Sounding from above requires an orbiting spacecraft with multichannel microwave spectrometers such as the instrument proposed for MO by a subset of the authors, a putative MESUR orbiter, and a proposed Discovery mission called MOES. Such an instrument can be built with less than 10 kg and use less than 15 W. The obvious advantage of this approach is that the entire atmosphere can be sounded for temperature and water vapor in a few hours with somewhat better than a scale height resolution. If a bigger mirror is used (greater than 30 cm) limb sounding geometry can be employed and half scale height resolution achieved to altitudes up to at least 60 km. Again, the measurements are immune to dust and ice loads. Water vapor sensitivity of 0.1 micrometer can be achieved (even with a nadir instrument) and temperature profiles retrieved to an accuracy of better than 2 K from the surface to about 60 km. Winds can be measured from the doppler shifts of CO lines in the limb sounding mode.

Muhleman, D. O.↗

An analysis of Solar Mesospheric Explorer temperatures for the upper stratosphere and mesosphere

We proposed to analyze Solar Mesosphere Explorer (SME) limb profiles of Rayleigh scattered solar flux at wavelengths of 304, 313, and 443 nm to retrieve atmospheric temperature profiles over the 40-65 km altitude region. These temperatures can be combined with the previous analysis of SME 296 nm limb radiances to construct a monthly average climatology of atmospheric temperatures over the 40-90 km, upper stratosphere-mesosphere region, with approximately 4 km vertical resolution. We proposed to investigate the detailed nature of the global temperature structure of this poorly measured region, based on these 1982-1986 SME temperatures. The average vertical structure of temperatures between the stratopause and mesopause has never been determined globally with vertical resolution sufficient to retrieve even scale-height structures. Hence, the SME temperatures provided a unique opportunity to study the detailed thermal structure of the mesosphere, in advance of Upper Atmosphere Research Satellite (UARS) measurements and the Thermosphere Ionosphere Mesosphere Energy and Dynamics (TIMED) mission.

Clancy, R. Todd↗

The role of visual context in manual target localization

During space flight and immediately after return to the 1-g environment of earth, astronauts experience perceptual and sensory-motor disturbances. These changes result from adaptation of the astronaut to the microgravity environment of space. During space flight, sensory information from the eyes, limbs, and vestibular organs is reinterpreted by the central nervous system in order to produce appropriate body movements in the microgravity. This adaptation takes several days to develop. Upon return to earth, the changes in the sensory-motor system are no longer appropriate to a 1-g environment. Over several days, the astronaut must re-adapt to the terrestrial environment. Alterations in sensory-motor function may affect eye-head-hand coordination and, thus, the crewmember's ability to manually locate objects in extrapersonal space. Previous reports have demonstrated that crewmembers have difficulty in estimating joint and limb position and in pointing to memorized target positions on orbit and immediately postflight. The ability to point at or reach toward an object or perform other manual tasks is essential for safe Shuttle operation and may be compromised particularly during re-entry and landing sequences and during possible emergency egress from the Shuttle. An understanding of eye-head-hand coordination and the changes produced during space flight is necessary to develop effective countermeasures. This summer's project formed part of the study of the sensory cues use in the manual localization of objects.

Barry, Susan R.↗

NOAA-9 Earth Radiation Budget Experiment (ERBE) scanner offsets determination

The Earth Radiation Budget Experiment (ERBE) instruments are designed to measure the components of the radiative exchange between the Sun, Earth and space. ERBE is comprised of three spacecraft, each carrying a nearly identical set of radiometers: a three-channel narrow-field-of-view scanner, a two-channel wide-field-of-view (limb-to-limb) non-scanning radiometer, a two-channel medium field-of view (1000 km) non-scanning radiometer, and a solar monitor. Ground testing showed the scanners to be susceptible to self-generated and externally generated electromagnetic noise. This paper describes the pre-launch corrective measures taken and the post-launch corrections to the NOAA-9 scanner data. The NOAA-9 scanner has met the mission objectives in accuracy and precision, in part because of the pre-launch reductions of and post-launch data corrections for the electromagnetic noise.

Avis, Lee M.↗

L-alpha intensity in coronal streamers

White-light images are presently the primary source of information on physical conditions in the solar corona at distances greater than a few tenths of a solar radius above the limb. As a consequence, we still only have an incomplete description of structures extending beyond the solar limb. In particular, streamers, although observed for decades, represent a poorly known phenomenon. SOHO, to be launched in 1995, will be able to make long-term observations of these features up to heights of a few solar radii, both in white light and UV. In this paper we present simulations of L-alpha intensity in coronal streamers, based on the two-dimensional (2D) model developed by Wang et at. (1992, 1993) via a time-dependent numerical relaxation approach. Because the model is 2D, we make an a priori hypothesis about the extension of streamers in the third dimension. L-alpha data, obtained from a rocket (Kohl et al., 1983), allowed us to identify a shape which fits the observations.

Noci, G.↗

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗

SPEAM-II experiment for the measurement of stratospheric NO2, O3 and aerosols

Following the success of the Sunphotometer Earth Atmosphere Measurement (SPEAM-I) experiment, a more involved experiment was developed to fly as part of the second set of Canadian Experiments (CANEX-2) which will fly on the US Space Shuttle in the fall of 1992. The instrument complement includes an IBM-PC compatible control computer, a hand-held diode array spectrophotometer, and an interference-filter, limb imaging radiometer for the measurement of the atmospheric airglow. The hand-held spectrometer will measure nitrogen dioxide, ozone and aerosols. The limb imaging radiometer will observe emissions from the O2(1 DELTA) and O2(1 SIGMA) airglow bands. Only the spectrophotometer will be discussed here.

Mcelroy, C. T.↗