FRIB Cryogenic Distribution System and Status

The MSU-FRIB cryogenic distribution system supports the 2 K primary, 4 K primary, and 35 - 55 K shield operation of more than 70 loads in the accelerator and the experimental areas. It is based on JLab and SNS experience with bayonet-type disconnects between the loads and the distribution system for phased commissioning and maintenance. The linac transfer line, which features three separate transfer line segments for additional independence during phased commissioning at 4 K and 2 K, connects the folded arrangement of 49 cryomodules and 4 superconducting dipole magnets and a fourth transfer line supports the separator area cryo loads. The pressure reliefs for the transfer line process lines, located in the refrigeration room outside the tunnel/accelerator area, are piped to be vented outdoors. The transfer line designs integrate supply and return flow paths into a combined vacuum space. The main linac distribution segments are produced in a small number of standard configurations; a prototype of one such configuration has been fabricated at Jefferson Lab and has been installed at MSU to support testing of a prototype FRIB cryomodule.

Ganni, Venkatarao↗

Testing of a 4 K to 2 K heat exchanger with an intermediate pressure drop

Most large sub-atmospheric helium refrigeration systems incorporate a heat exchanger at the load, or in the distribution system, to counter-flow the sub-atmospheric return with the super-critical or liquid supply. A significant process improvement is theoretically obtainable by handling the exergy loss across the Joule-Thompson throttling valve supplying the flow to the load in a simple but different manner. As briefly outlined in previous publications, the exergy loss can be minimized by allowing the supply flow pressure to decrease to a sub-atmospheric pressure concurrent with heat exchange flow from the load. One practical implementation is to sub-divide the supply flow pressure drop between two heat exchanger sections, incorporating an intermediate pressure drop. Such a test is being performed at Jefferson Lab's Cryogenic Test Facility (CTF). This paper will briefly discuss the theory, practical implementation and test results and analysis obtained to date.

Knudsen, Peter N.↗

Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

Knudsen, Peter N.↗

Commissioning and operational results of the 12 GeV helium compression system at Jlab

The new compressor system at Jefferson Lab (JLab) for the 12 GeV upgrade was commissioned in the spring of 2013 and incorporates many design changes, discussed in previous publications, to improve the operational range, efficiency, reliability and maintainability as compared to previous compressor skids used for this application. The 12 GeV helium compression system has five compressors configured with four pressure levels supporting three pressure levels in the new cold box. During compressor commissioning the compressors were operated independent of the cold box over a wide range of process conditions to verify proper performance including adequate cooling and oil removal. Isothermal and volumetric efficiencies over these process conditions for several built-involume ratios were obtained. This paper will discuss the operational envelope results and the modifications/improvements incorporated into the skids.

Knudsen, Peter N.↗

Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

Analysis of data obtained during the spring 2013 commissioning of the new 4.5-K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required a higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes. This testing demonstrated the modifications resulted in a LN consumption significantly lower than the expected design for the nominal and maximum capacity modes and equal to the expected design for the pure refrigeration mode (which is the most demanding). The testing also demonstrated that the refrigerator system has a good and fairly constant performance over this wide capacity range and different modes of operation. Also, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure ? Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behavior of the system to a pulsed load.

Knudsen, P.↗

Online helium inventory monitoring of JLab cryogenic systems

There are five cryogenic plants at Jefferson Lab which support the LINAC, experiment hall end-stations and test facility. The majority of JLab's helium inventory, which is around 15 tons, is allocated in the LINAC cryo-modules, with the majority of the balance of helium distributed at the cryogenic-plant level mainly as stored gas and liquid for stable operation. Due to the organic evolution of the five plants and independent actions within the experiment halls, the traditional inventory management strategy suffers from rapid identification of potential leaks. This can easily result in losses many times higher than the normally accepted (average) loss rate. A real-time program to quickly identify potential excessive leakage was developed and tested. This program was written in MATLAB© for portability, easy diagnostics and modification. It interfaces directly with EPICS to access the cryogenic system state, and with and NIST REFPROP© for real fluid properties. This program was validated against the actual helium offloaded into the system. The present paper outlines the details of the inventory monitoring program, its validation and a sample of the achieved results.

42 ENGINEERING↗

Applicability of ASST-A Helium Refrigeration System for JLab End Station Refrigerator

The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab's four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab's Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

42 ENGINEERING↗

A smart alarm for particle accelerator beamline operations

We present the initial results of a proof-of-concept 'smart alarm' for the Continuous Electron Beam Accelerator Facility injector beamline at Jefferson Lab. To minimize machine downtime and improve operational efficiency, an autonomous alarm system able to identify and diagnose unusual machine states is needed. Our approach leverages a trained neural network capable of alerting operators (a) when an anomalous condition exists in the beamline and (b) identifying the element setting that is the root cause. The tool is based on an inverse model that maps beamline readings (diagnostic readbacks) to settings (beamline attributes operators can modify). The model takes as input readings from the machine and computes machine settings which are compared to control setpoints. Instances where predictions differ from setpoints by a user-defined threshold are flagged as anomalous. Given data corresponding to 354 anomalous injector configurations, the model can narrow the root cause of an anomalous condition to three potential candidates with 94.6% accuracy. Furthermore, compared to the current method of identifying anomalous conditions which raises an alarm when machine parameters drift outside their normal tolerances, the data-driven model can identify 83% more anomalous conditions.

43 PARTICLE ACCELERATORS↗

The cross-section measurement for the 3 H($e, e'K^+)nnΛ$ reaction

The small binding energy of the hypertriton leads to predictions of the non-existence of bound hypernuclei for isotriplet three-body systems such as nnΛ. However, invariant mass spectroscopy at GSI has reported events that may be interpreted as the bound nnΛ state. The nnΛ state was sought by missing-mass spectroscopy via the (e, e'K + ) reaction at Jefferson Lab’s experimental Hall A. The present experiment has higher sensitivity to the nnΛ-state investigation in terms of better precision by a factor of about three. The analysis shown in this article focuses on the derivation of the reaction cross-section for the 3 H(γ*, K + )X reaction. Events that were detected in an acceptance, where a Monte Carlo simulation could reproduce the data well (|δp/p| < 4%), were analyzed to minimize the systematic uncertainty. No significant structures were observed with the acceptance cuts, and the upper limits of the production cross-section of the nnΛ state were obtained to be 21 and $31 nbsr -1 at the 90% confidence level when theoretical predictions of (-B Λ , Γ) = (0.25, 0.8) MeV and (0.55, 4.7) MeV, respectively, were assumed. The cross-section result provides valuable information for examining the existence of nnΛ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

String-based axial and helicity-flip GPDs: A comparison to lattice QCD

We construct an analytic, string-based representation of the nucleon’s axial and helicity-flip conformal moments of generalized parton distributions (GPDs) that holds for skewness and for both the quark and gluon channels. The starting point is the Mellin-Barnes resummation of the conformal partial-wave expansion, where the moments are parametrized by open- (Reggeon) and closed-string (Pomeron) trajectories with slopes determined by experimental form factors and meson/glueball spectroscopy. The forward limits are fixed by the empirical unpolarized and polarized parton distributions. Polynomiality, crossing symmetry, and support are satisfied by construction. After next-to-leading order Dokshitzer-Gribov-Lipatov-Altarelli-Parisi/Efremov-Radyushkin-Brodsky-Lepage evolution to μ = 2 GeV our analytic framework (i) reproduces some of the currently available lattice moments of E and H˜ in the nonsinglet sector, (ii) predicts sea-quark and gluon polarized moments that will be testable by forthcoming simulations and experiments at Jefferson Lab and the future Electron-Ion Collider, and (iii) yields axial and helicity-flip GPDs in x-space in reasonable agreement with lattice QCD.

Gauge-gravity dualities↗

Nucleon resonances with hidden charm in γ p reactions

Here, we add the resonant γp → N* c¯c → J/ψp amplitudes to examine the effects of N* c¯c excitations on the cross sections of γp→J/ψp in the near threshold energy region covered by the recent experiments at Jefferson Lab. The N* c¯c → MB transition matrix elements are determined from the partial decay widths predicted by the considered meson-baryon coupled-channel models of N* c¯c .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam asymmetry Σ for the photoproduction of η and η ' mesons at E γ = 8.8 GeV

In this work, we report on the measurement of the beam asymmetry $\Sigma$ for the reactions $\vec{\gamma}p\rightarrow p\eta$ and $\vec{\gamma}p \rightarrow p\eta^{\prime}$ from the GlueX experiment, using an 8.2–8.8-GeV linearly polarized tagged photon beam incident on a liquid hydrogen target in Hall D at Jefferson Lab. These measurements are made as a function of momentum transfer $-t$, with significantly higher statistical precision than our earlier $\eta$ measurements, and are the first measurements of $\eta^{\prime}$ in this energy range. We compare the results to theoretical predictions based on $t$--channel quasi-particle exchange. Furthermore, we compare the ratio of $\Sigma_{\eta}$ to $\Sigma_{\eta^{\prime}}$ to these models, as this ratio is predicted to be sensitive to the amount of $s\bar{s}$ exchange in the production. We find that photoproduction of both $\eta$ and $\eta^{\prime}$ is dominated by natural parity exchange with little dependence on $-t$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electroweak probes of ground state densities

Background: Elastic electron scattering has been used for decades to paint the most accurate picture of the proton distribution in atomic nuclei. This stands in stark contrast to the neutron distribution that is traditionally probed using hadronic reactions that are hindered by large uncertainties in the reaction mechanism. Spurred by new experimental developments, it is now possible to gain valuable insights into the neutron distribution using exclusively electroweak probes. Purpose: In this work, we aim to assess the information content and complementarity of the following three electroweak experiments in constraining the neutron distribution of atomic nuclei: (a) parity-violating elastic electron scattering, (b) coherent elastic neutrino-nucleus scattering, and (c) elastic electron scattering of unstable nuclei. Methods: Relativistic mean-field models informed by the properties of finite nuclei and neutron stars are used to compute ground state densities and form factors of a variety of nuclei. All the models follow the same fitting protocol, except for the assumed—and presently unknown—value of the neutron skin thickness of 208 Pb. This enables one to tune the density dependence of the symmetry energy without compromising the success in reproducing well known physical observables. Results: We found that the ongoing PREX-II and upcoming CREX campaigns at Jefferson Lab will play a vital role in constraining the weak form factor of xenon and argon, liquid noble gases that are used for the detection of both neutrinos and dark matter particles. Conclusions: Remarkable new advances in experimental physics have opened a new window into ground state densities of atomic nuclei using solely electroweak probes. The diversity and versatility of these experiments reveal powerful correlations that impose important nuclear structure constraints. In turn, these constraints provide quantitative theoretical uncertainties that are instrumental in searches for new physics and insights into the behavior of dense matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lepton scattering from Ar 40 and Ti 48 in the quasielastic peak region

Neutron and proton spectral functions of 40 Ar, 40 Ca, and 48 Ti isotopes are computed using the ab initio self-consistent Green's function approach. The resulting radii and charge distributions are in good agreement with available experimental data. The spectral functions of Ar and Ti are then utilized to calculate inclusive (e,e') cross sections within a factorization scheme and are found to correctly reproduce the recent Jefferson Lab measurements. Based on these successful agreements, the weak charged and neutral current double-differential cross sections for neutrino- 40 Ar scattering are predicted in the quasielastic region. Finally, results obtained by replacing the (experimentally inaccessible) neutron spectral distribution of 40 Ar with the (experimentally accessible) proton distribution of 48 Ti are compared and the accuracy of this approximation is assessed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the photon beam asymmetry in γ → p → K + Σ 0 at E γ = 8.5 GeV

We report measurements of the photon beam asymmetry $\Sigma$ for the reaction $\vec{\gamma} p\to K^+\Sigma^0$(1193) using the GlueX spectrometer in Hall D at Jefferson Lab. Data were collected using a linearly polarized photon beam in the energy range of 8.2-8.8 GeV incident on a liquid hydrogen target. The beam asymmetry $\Sigma$ was measured as a function of the Mandelstam variable $t$, and a single value of $\Sigma$ was extracted for events produced in the $u$-channel. These are the first exclusive measurements of the photon beam asymmetry $\Sigma$ for the reaction in this energy range. For the $t$-channel, the measured beam asymmetry is close to unity over the $t$-range studied, $-t=(0.1-1.4)~$(GeV/$c$)$^{2}$, with an average value of $\Sigma = 1.00\pm 0.05$. This agrees with theoretical models that describe the reaction via the natural-parity exchange of the $K^{*}$(892) Regge trajectory. A value of $\Sigma = 0.41 \pm 0.09$ is obtained for the $u$-channel integrated up to $-u=2.0$~(GeV/$c$)$^{2}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Novel observation of isospin structure of short-range correlations in calcium isotopes

Short Range Correlations (SRCs) have been identiffed as being responsible for the high momentum tail of the nucleon momentum distribution, n(k). Hard, short-range interactions of nucleon pairs generate the high momentum tail and imprint a universal character on n(k) for all nuclei at large momentum. Triple coincidence experiments have shown a strong dominance of np pairs, but these measurements involve large final state interactions. This paper presents the results from Jefferson Lab experiment E08014 which measured inclusive electron scattering cross-section from Ca isotopes. Here, by comparing the inclusive cross section from 48 Ca to 40 Ca in a kinematic region dominated by SRCs we provide a new way to study the isospin structure of SRCs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Examining the EMC effect using the ${F}_{2}^{n}$ neutron structure function

The persistently mysterious deviations from unity of the ratio of nuclear target structure functions to those of deuterium as measured in deep inelastic scattering (often termed the “EMC effect”) have become the canonical observable for studies of nuclear medium modifications to free nucleon structure in the valence regime. The structure function of the free proton is well known from numerous experiments spanning decades. The free neutron structure function, however, has remained difficult to access. Recently it has been extracted in a systematic study of the global data within a parton distribution function extraction framework and is available from the CTEQ–Jefferson Lab (CJ) Collaboration. Here, we leverage the latter to introduce a new method to study the EMC effect in nuclei by reexamining existing data in light of the the magnitude of the medium modifications to the free neutron and proton structure functions independently. From the extraction of the free neutron from world data, it is possible to examine the nuclear effects in deuterium and their contribution to our interpretation of the EMC effect. In this study, we observe that the ratio of the deuteron to the sum of the free neutron and proton structure functions has some x B and Q 2 dependencies that impact the magnitude of the EMC effect as typically observed. Specifically, different EMC slopes are obtained when data from different x B and Q 2 values are utilized. Furthermore, while a linear correlation persists between the EMC and short range correlation effects, the slope is modified when deuteron nuclear effects are removed.