Impact of Inverter Based Resource (IBR) Negative Sequence Current Injection on Transmission System Protection.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
NREL and UL co-presented on their joint effort to develop a cybersecurity certification standard for distributed energy resources (DERs) at a meeting of the Cybersecurity Advisory Team for State Solar (CATSS). The advisory team is hosted by NASEO & NARUC. The presentation outlined the benefits of a cybersecurity certification standard, the outcomes of previous initiatives, how this effort reflects the evolving electric grid, and the role of state energy offices. UL explained their role as a trusted third party with expertise to lead this effort and the process from Outline of Investigation (OOI) to a certification standard.
This poster presents the results of using the self-synchronized universal droop controller to enable solar power to provide ancillary services so that the use of solar power can be increased. A 300-node system using the IEEE 123 bus test feeder are modeled on a real time power system simulator with the results presented.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A distributed control system uses a central controller in Internet communication with a local controller to manage grid tie attachment with a battery to form an integrated battery energy storage system (BESS). The BESS is capable of charging or discharging the battery, as well as correcting grid phase with volt amp reactive (VAR) leading or lagging operation modes. Examples shown include simple BESS charging and discharging, BESS integrated with renewable energy sources (here photovoltaic), and direct current fast charge (DCFC) connections with an electric vehicle.
A switching circuit includes a diode, a semiconductor switch, and a first bidirectional switch. The semiconductor switch is configured to conduct a first current from a second terminal to a third terminal of the semiconductor switch when a first on-state signal is sent to a first terminal of the semiconductor switch. An anode of the diode is connected to the second terminal of the semiconductor switch, and a cathode of the diode is connected to the third terminal of the semiconductor switch. The first bidirectional switch includes a first terminal, a second terminal connected to the anode of the diode, and a third terminal and is configured to conduct a second current from the second terminal to the third terminal or from the third terminal to the second terminal when a second on-state signal is sent to the first terminal of the first bidirectional switch.
Explore the source record for details and available documents.
Tin (IV) oxide (SnO 2 ) is a good electron transport material for perovskite photovoltaics high charge carrier mobility and superior stability Low temperature solution processability of SnO 2 low-cost fabrication lightweight and flexible perovskite solar cells on PET-based substrate Direct deposition of solution-processed SnO 2 on the top of perovskite is challenging solvent in compatibility with the perovskite materials To solve this problem, in this study we: synthesized SnO 2 nanoparticles functionalized them with acetate through ligand exchange allowing their dispersion in anhydrous ethanol
In an embodiment, a semiconductor device is provided that includes a lateral transistor device having a source, a drain and a gate, and a monolithically integrated capacitor coupled between the gate and the drain.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The Modbus communication protocol is a widely adopted communication standard in industrial control systems. This communication protocol is known for being reliable and straightforward to implement while being versatile in terms of its operating parameters while supporting multiple formats over various hardware infrastructures and architectures. Many intelligent devices such as Programmable Logic Controllers (PLCs), Human-Machine Interfaces (HMIs), Internet-of-Things (IoT), and various Operational Technologies (OT) utilize Modbus for their communication systems. These types of systems must communicate with each other through a standardized and central communication process. To support the integration of these modular systems, a Field-Programmable Gate Array (FPGA) can act as an embedded central routing fabric for this communication to take place. Embedded systems are versatile enough to interface with various devices and systems to accomplish various goals. Additionally, embedded systems require relatively small physical designs to minimize the required resources to facilitate the intended application by providing low-level system access. This minimization of system resources goes hand in hand with reducing the financial cost of a proposed solution or system. As remotely collaborating researchers often use FPGAs to prototype designs that are required to have a method for data transmission among systems, it is imperative to provide a baseline standard for communications among devices and systems. A typical method of implementing the Modbus RTU communication protocol in an embedded environment is using integrated logic architectures within the FPGA called “Intellectual Property (IP) cores.” IP cores can be designed using integrated logic or circuit designs to function as an embedded processor. These IP cores can then perform the required computational actions to support the Modbus RTU communication protocol by utilizing high-level programming languages such as the C programming language. The hardware description language of Very High-Speed Integrated Circuit Hardware Description Language (VHDL) allows for the control of real hardware at the logic gate and signal level. These logic gates and signals can be designed and controlled to perform desired actions based on the system design. Programming an FPGA using VHDL allows an individual to access the lowest abstraction level of the system during FPGA development. This level of abstraction is referred to as the register-transfer level (RTL), which gives access to manipulating values and variables at the register level. This register-level manipulation provides precision over creating the logical circuit within the FPGA, thus minimizing the required code to perform desired operations. The Modbus RTU communication protocol can be implemented within an FPGA using VHDL programming to establish a standardized and embedded serial communication pathway. This implementation provides a standardized communication protocol to streamline research efforts among researchers, thus increasing the efficiency of research efforts. Additionally, this Modbus RTU implementation requires fewer resources when compared to typical communication protocol implementations that utilize an IP core, reducing the hardware requirement for effective research efforts.