Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Infrared Thermometer (IRT) Instrument Handbook

The Infrared Thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the equivalent blackbody brightness temperature of the scene in its field of view. The downwelling version has a narrow field of view for measuring sky temperature and for detecting clouds. The upwelling version has a wide field of view for measuring the narrowband radiating temperature of the ground surface.

47 OTHER INSTRUMENTATION↗

Microwave Radiometer Profiler (MWRP) Instrument Handbook

The Microwave Radiometer Profiler (MWRP) provides time-series measurements of brightness temperatures from 12 channels between 22.235 and 58.80 GHz. These channels are sensitive to the presence of liquid water and precipitable water vapor and to the atmospheric temperature and humidity profile.

47 OTHER INSTRUMENTATION↗

Tower Camera (TWR CAM) Instrument Handbook

The NSA-C1 Utqiagvik tower camera is installed at a height of 40 meters above the ground at the topmost boom of the meteorological tower. The camera’s main field of view is directed at the tundra south of the tower, where the 10m Tip Tower is located. The camera captures images of the Tip Tower and the surrounding ground every 30 minutes. Since September 2017, the camera model is the AXIS Q6045-E Mk II PTZ Dome Network Camera. The tower camera images provide a qualitative look at the progression of the seasons at Utqiagvik. The tower camera images are useful for determining the fractional snow or vegetation cover. Additionally, the camera provides a glimpse of on-site weather conditions, showing the changing weather and/or ground conditions.

47 OTHER INSTRUMENTATION↗

Astro2020 APC White Paper: The MegaMapper: a z > 2 Spectroscopic Instrument for the Study of Inflation and Dark Energy

MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at 2¡z¡5. A 6.5-m Magellan telescope will be coupled with DESI spectrographs to achieve multiplexing of 20,000. MegaMapper would be located at Las Campanas Observatory to fully access LSST imaging for target selection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weighing Bucket Rain Gauge Instrument Handbook

The OTT precipitation gauge is used for automatic determination of the intensity and amount of precipitation. In contrast to conventional precipitation gauges, the Pluvio2 works using the balance principle. The gauge reliably recognizes precipitation by determining the weight of the collecting bucket. A high-precision stainless steel load cell, hermetically sealed against environmental influences, is used as the sensor element. An integrated temperature sensor compensates for the temperature changes in the weighing mechanism. These sensors have been found to be stable for years. The orifice of the gauge is heated and when snow/ice precipitation occurs, the weight of its water equivalent is the amount observed.

42 ENGINEERING↗

Aircraft Video Camera (CAM-AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF) video cameras are installed in the cockpit of ARM’s research aircraft looking forward and in the belly of the plane looking down at the ground. Prior to the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign in the Azores during 2017, the P1344 camera was flown in the forward (cockpit) position and the P1347 camera was flown in the nadir (belly) position. Since only the forward camera was flown for ACE-ENA and the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina during 2018–2019, the camera with the higher resolution (P1347) was moved to the cockpit.

47 OTHER INSTRUMENTATION↗

Detector Instrumentation, Energy Reconstruction and Data Analysis in the DUNE and NOvA Neutrino Experiments

Neutrino oscillations are so far the only experimental observation beyond the standard model since its development four decades ago. The remaining fundamental questions that can be answered by long-baseline neutrino oscillations are (1) the CP violation (whether neutrinos and antineutrinos behave the same way in oscillation), and (2) the mass hierarchy ($m_3>m_{1,2}$ or $m_{1,2}>m_3$), and (3) the octant of $\theta_{23}$ ($\theta_{23}>45^\circ, =45^\circ$ or $<45^\circ$). The PI's group at UCI focuses on long-baseline neutrino experiments DUNE and NOvA, key components of DOE's Intensity Frontier program. NOvA is the current major U.S.-based long-baseline neutrino experiment aiming to solve the mass hierarchy and $\theta_{23}$ octant. It is taking $\nu$ and $\bar{\nu}$ data from the NuMI beam at Fermilab. DUNE is the next-generation flagship neutrino experiment in the U.S. which is designed to decisively determine neutrino CP violation, mass hierarchy and $\theta_{23}$ octant. DUNE is Fermilab's first priority, and has been established as an international collaboration. During the period covered by the report, the PI's group has been exceptionally productive, with leading contributions to DUNE argon-purity monitoring detectors, NOvA/DUNE deep-learning reconstruction, and NOvA oscillation and near detector (ND) analyses. The group also is actively involved in DUNE/NOvA detector operation, data production, calibration, software upgrade and maintenance, and ProtoDUNE cold electronic QA/QC. Specifically, we have made accomplishments in the following four research projects: 1) Purity monitor R\&D and data analysis for DUNE, 2) Deep-learning-based energy reconstruction at NOvA and DUNE, 3) Oscillation analysis at NOvA, and 4) $\nu$-e elastic scattering analysis at NOvA.

47 OTHER INSTRUMENTATION↗

Application-Specific Implementations: Self-Consistent Analysis, Uncertainty Estimation, Instrumentation Effects

When UF 6 is located on the bottom of a cylindrical container lying flat, the Hage-Cifarelli formalism can be used to reconstruct the multiplication of the UF 6 and the strength of the 234 U (a,n) source, from which the 235 U can be inferred. However, when the UF 6 sticks to the ends or to the sides of the container, the reconstruction is no longer predictive in terms of source strength. The same conclusions were reached, whether one uses 3 He tubes or scintillators to detect the neutrons. Feynman’s point theory underlying the reconstruction would need to be improved to address the differences in source strenghts observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single-Channel Tricolor Absorption Photometer (STAP) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (MOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook describes the principles and operations of the single-channel tricolor absorption photometer, Model 9406.

47 OTHER INSTRUMENTATION↗

Interactive Radiation Detection Instrumentation

This presentation will be presented at the International Joint Meeting on Nuclear/Radiological Security for Major Public Events in Minneapolis, Minnesota during January 30 - February 2, 2018 sponsored by DOE/NNSA Office of Nuclear Incident Policy and Cooperation and the International Atomic Energy Agency. .

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Instrumentation Testbed (AIT) - antiNeutrino Experiment One (NEO) (Q1 FY2021)

In anticipation of the planned June 2021 design review, conceptual design, costing, and documentation efforts continued. The quarter was highlighted by the completion of three significant milestones: 1) 50% conceptual design and costing of the AIT facility, 2) bottom-up cost estimates for NEO, and 3) parametric NEO performance estimates (via the Big Trade Study). Because cost estimates exceed available funding levels, the project team started (late Dec 2020) a value engineering/pivot exercise to align costs with available funds. This exercise is anticipated to consume the project team for most of Q2. The end-result expectation (of the exercise) is a programmatically feasible and scientifically relevant AIT-NEO conceptual design that is aligned with available funds.

42 ENGINEERING↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multispectral and Thermal Imager Onboard Aerial Platforms Instrument Handbook

The MicaSense Altum imager is an off-the-shelf, synchronized multispectral and thermal camera, combined with a Global Positioning System (GPS) unit and downwelling light sensor (DLS). The Altum takes images of the land surface within its field of view (FOV) across five visible bands and one longwave infrared thermal band. The sensor records the radiance and converts it to digital numbers. Imagery is radiometrically corrected, taking into account the sensor calibration, lens distortions, vignette effects, sun angle, and atmospheric effects (scattering and absorption). The photogrammetry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composite image using the technique of structure from motion image capture to construct a dense cloud and 3D model of the surface, which is used to produce a digital elevation model of the terrain surveyed and orthomosaic imagery. Land surface leaf area index, albedo, and surface skin temperature are provided for the user. The user can perform raster calculations on the imagery to produce various other vegetative indices, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). This code is provided with the readme file for each data set. The images have a resolution of 20-60 cm/pixel, which are subsampled to 100 cm/pixel.

47 OTHER INSTRUMENTATION↗