Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Status of the GAMMA-400 Project

The preliminary design of the new space gamma-ray telescope GAMMA-400 for the energy range 100 MeV-3 TeV is presented. The angular resolution of the instrument, 1-2 deg at E(gamma) approximately 100 MeV and approximately 0.01 at E(gamma) greater than 100 GeV, its energy resolution is approximately 1% at E(gamma) greater than 100 GeV, and the proton rejection factor is approximately 10(exp 6) are optimized to address a broad range of science topics, such as search for signatures of dark matter, studies of Galactic and extragalactic gamma-ray sources, Galactic and extragalactic diffuse emission, gamma-ray bursts, as well as high-precision measurements of spectra of cosmic-ray electrons, positrons, and nuclei.

Galper, A. M.↗

MISR Calibration Issues in High-Contrast Scenes, and Empirical Corrections

We diagnose the potential causes for the Multi-angle Imaging SpectroRadiometer's (MISR) persistent high aerosol optical depth (AOD) bias at low AOD with the aid of coincident MODerate-resolution Imaging Spectroradiometer (MODIS) imagery from NASA's Terra satellite. Internal reflections within the MISR instrument are responsible for a large portion of the high AOD bias in high-contrast scenes, which are especially common as broken-cloud situations over ocean. Discrepancies between MODIS and MISR nadir-viewing near-infrared (NIR) images are used to optimize nine parameters, along with a background reflectance modulation term (that was modeled separately), to represent the observed features. Independent, surface-based AOD measurements from the AErosol RObotic NETwork (AERONET) and the Marine Aerosol Network (MAN) are compared with MISR Research Algorithm (RA) AOD retrievals for 1118 coincidences to validate the corrections when applied to the nadir and off-nadir cameras. Additionally, the calibration coefficients for the red and NIR channels used for MISR over-water aerosol retrievals were reassessed with the RA to be consistent on a camera-by-camera basis. With these corrections, plus the baseline RA corrections applied (except enhanced cloud screening), the median AOD bias in the mid-visible (green) band decreases from 0.010 to 0.002, the RMSE decreases by approx. 10%, and the slope and correlation of the MISR vs. sun photometer Ångström Exponent improves. For AOD558 nm < 0.10 and with additional cloud screening, the median bias for the RA-retrieved AOD in the green band decreases from 0.011 to 0.003, compared to ~ 0.023 for the Standard Algorithm (SA). RMSE decreases by ~ 20% compared to the baseline (uncorrected) RA and by 17-53% compared to the SA. After all corrections and cloud screening are implemented, for AOD558 nm < 0.10, which includes about half the validation data, 68% absolute AOD errors for the RA have dropped to < 0.02 (approx. 0.018).

MISR↗

Identifying Shocked Feldspar on Mars Using Perseverance Spectroscopic Instruments: Implications for Geochronology Studies on Returned Samples

The Perseverance rover (Mars 2020) mission, the first step in NASA’s Mars Sample Return (MSR) program, will select samples for caching based on their potential to improve understanding Mars’ astrobiological, geological, geochemical, and climatic evolution. Geochronologic analyses will be among the key measurements planned for returned samples. Assessing a sample’s shock history will be critical because shock metamorphism could influence apparent sample age. Shock effects in one Mars-relevant mineral class, plagioclase feldspar, have been well- documented using various spectroscopy techniques (thermal infrared reflectance, emission, and transmission spectroscopy, Raman, and luminescence). A subset of these data will be obtained with the SuperCam and SHERLOC (Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals) instruments onboard Perseverance to inform caching decisions for MSR. Here, we review shock indicators in plagioclase feldspar as revealed in Raman, luminescence, and IR spectroscopy lab data, with an emphasis on Raman spectroscopy. We consider how this information may inform caching decisions for selecting optimal samples for geochronology measurements. We then identify challenges and make recommendations for both in situ measurements performed with SuperCam and SHERLOC and for supporting lab studies to enhance the success of geochronologic analyses after return to Earth.

mars↗

Material Inspectability Assessment Related to Lunar Construction Technology Development

For the building of lunar structures on the Moon using lunar regolith-based construction materials, ensuring their structural integrity and employing methods optimal for such tasks is crucial. In this technical memorandum (TM) the detectability of simulated void defects in a cementitious-based lunar construction material is compared between different nondestructive evaluation (NDE) methods, especially methods which have potential to be developed into space qualified instruments. Primarily, simulated voids, introduced during fabrication as foam spheres, were used for this evaluation. Furthermore, smaller, unintended void defects were used to assess the detectability. The results highlights trade-offs between the NDE methods in terms of detection limit, correct size indication, penetration depth, and potential for reduction in size, weight, and power (SWaP).

Nondestructive Evaluation↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept of Very-Asymmetric lepton Collider for dark matter search

Accelerator-based searches for dark matter are aiming for high sensitivity and need an experimental setup with high luminosity. This field of research is often called intensity frontier physics. One of the best motivated portals of interaction between dark matter and ordinary matter is a dark photon which could be observed as a resonance in the invariant mass of the decay products. Electron–positron collisions are known to be the cleanest interaction for such a study. In this paper we propose a scheme for a collider which allows for a luminosity of a few orders of magnitude higher than could be obtained in a conventional symmetric collider and with a few times higher accessible mass than is possible using a positron beam and a fixed target approach. The key concept is based on asymmetric energies: a high-energy circulating positron beam and a low-energy high-intensity electron beam, and optimization of the beam interaction region. We present here a configuration of a collision region of 10 MeV electron and 4 GeV positron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operating advanced scientific instruments with AI agents that learn on the job

Advanced scientific user facilities, such as next generation X-ray light sources and self-driving laboratories, are revolutionizing scientific discovery by automating routine tasks and enabling rapid experimentation and characterizations. However, these facilities must continuously evolve to support new experimental workflows, adapt to diverse user projects, and meet growing demands for more intricate instruments and experiments. This continuous development introduces significant operational complexity, necessitating a focus on usability, reproducibility, and intuitive human-instrument interaction. In this work, we explore the integration of agentic AI, powered by Large Language Models (LLMs), as a transformative tool to achieve this goal. We present our approach to developing a human-in-the-loop pipeline for operating advanced instruments including an X-ray nanoprobe beamline and an autonomous robotic station dedicated to the design and characterization of materials. Specifically, we evaluate the potential of various LLMs as trainable scientific assistants for orchestrating complex, multi-task workflows, which also include multimodal data, optimizing their performance through optional human input and iterative learning. We demonstrate the ability of AI agents to bridge the gap between advanced automation and user-friendly operation, paving the way for more adaptable and intelligent scientific facilities.

Large Language Models↗

Using active learning to improve quasar identification for the DESI spectra processing pipeline

The Dark Energy Spectroscopic Instrument (DESI) survey uses an automatic spectral classification pipeline to classify spectra. QuasarNET is a convolutional neural network used as part of this pipeline originally trained using data from the Baryon Oscillation Spectroscopic Survey (BOSS). In this paper we implement an active learning algorithm to optimally select spectra to use for training a new version of the QuasarNET weights file using only DESI data, with the goal of improving classification accuracy. This active learning algorithm includes a novel outlier rejection step using a Self-Organizing Map to ensure we label spectra representative of the larger quasar sample observed in DESI. We perform two iterations of the active learning pipeline, assembling a final dataset of 5600 labeled spectra, a small subset of the approximately 1.3 million quasar targets in DESI's Data Release 1. When splitting the spectra into training and validation subsets we achieve similar performance to the previously trained weights file in completeness and purity calculated on the validation dataset but do so with less than one tenth of the amount of training data. The new weights also more consistently classify objects in the same way when used on unlabeled data compared to the old weights file. In the process of improving QuasarNET's classification accuracy we discovered a systemic error in QuasarNET's redshift estimation and used our findings to improve our understanding of QuasarNET's redshifts.

Machine learning↗

PAL Experimental Report Form

We constructed the first simultaneous dark- and bright-field X-ray microscope in this experiment, coupling it to simultaneous measurements of the wide-angle Xray diffraction, and the XFEL pulse intensity and energy spectrum on each shot. This experiment established proof of concept for this new advanced measurement technique and demonstrated DFXM at an XFEL for the first time. Within this complex experiment, we also acquired data that advanced our research goals within materials science and mathematics. These included: A preliminary study of how local effects reduce the X-ray damage threshold in diamond; A preliminary study of how X-ray radiation imparts heat into materials based on irreversible phase transitions that occur in boric acid with increasing temperature (based on hydration); A study of X-ray radiation damage from ultrafast thermal cycling and nonthermal melting in bismuth selenide; We also began developing software to automate alignment of compound refractive lenses (CRLs) using stochastic Nelder-Mead optimization methods. This work will expedite and improve the accuracy of alignments for many future experiments using CRLs.

36 MATERIALS SCIENCE↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Random Forest Optimization for Radionuclide Identification

Radionuclide identification through gamma-ray spectroscopy is an indispensable tool in combatting the illicit smuggling of nuclear material. The radionuclide identification devices used in the field need to provide ready-made answers to non-experts, and therefore require sophisticated algorithms that can interpret the underlying data. We investigated the Random Forest classifier as a tool for identifying the radionuclide that is consistent with the data. We were provided with training and validations data sets and used them to optimize the two hyperparameters of the classifiers: maximum features required, and minimum samples used to split each node. The F1 score, a harmonic mean of precision and recall, was used to evaluate the performance of each built classifier. We found the optimal performance with minimum samples of 5 and maximum features of 50, with the F1 score of 0.95.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Rheo-Structural Spectroscopy: Fingerprinting the In Situ Response of Fluids to Arbitrary Flow Fields

The objectives of this project were to develop new sample environments, measurement methodologies and associated modeling tools for characterizing the structural response to arbitrarily complex processing flows using small angle scattering, and to apply these new tools for understanding the fundamental physics governing the structuring of anisotropic particulate and polymeric materials under flow histories and conditions relevant to industrial processing flows. The research resulted in the development and implementation of a new sample environment, the fluidic four roll mill (FFoRM), for in situ small angle neutron and X-ray scattering (SANS/SAXS) measurements. These measurements are capable of generating large data sets that “fingerprint” how a complex fluid responds to a wide range of flow histories involving time variations in deformation type and rate. New modeling tools were developed to extract detailed microstructural information from such data sets, including orientation distribution functions and interparticle correlation functions, as well as reduced-order parametric descriptors of these high-dimensional functions that can be used to readily map, visualize and interpret a fluid’s structural response to its flow history. These new tools were applied to a range of model materials involving elongated particle suspensions in order to provide new insights into the physics of how flow couples with orientational and structural order in complex flows, particularly under non-dilute conditions for which no accurate theories currently exist. Using these investigations, we elucidated a number of new insights into the fundamental phenomena driving such process-structure-property relationships. These findings provide guidance for the further development of rheological models, and ultimately can inform the rational and model-based design of flow processes to achieve optimized orientational ordering that is key to the properties and function of a wide range of energy-relevant materials.

36 MATERIALS SCIENCE↗

Reflective Schmidt corrector

A technique based on the use of an off-axis corrector in two orthogonal planes is presented for optimizing the reflective corrector that is to replace the refractive corrector plate of a Schmidt camera in high resolution space astronomy applications. The technique can easily be applied to any off-axis angle depending on configuration, field of view, and focal ratio of the instrument. It is pointed out, however, that the general performance degrades and the field of view shrinks with increasing off-axis angles.

Korsch, D.↗

Preliminary design of an Earth-based debris detection system using current technology and existing installations

A simple instrument based on present-epoch technology for optical detection of orbital debris is described. The limits of detectability at various altitudes and under different operating conditions for this system are assessed. The kinds of information which can be deduced from this data are examined. Optimal systems for debris detection are discussed. Alternatives and possible improvements from new technologies are also considered.

Morgan, T. H.↗

Mission and sampling analyses for atmospheric satellite experiments

Orbital analyses, instrument-viewing geometry studies, and sampling simulations are performed to define mission concepts for advanced atmospheric research satellite experiments. These analyses are conducted in collaboration with NASA Headquarters and working groups consisting of atmospheric scientists and experiment developers. Analytical techniques are developed and used to optimize geographical coverage, sensor-viewing geometries, data gathering strategies, sampling schemes, orbital characteristics, satellite launch times, and operational modes of the various experiments and mission concepts. Short-term (7 day) Shuttle Missions, the Upper Atmosphere Research Satellite (UARS), and multisatellite missions such as the Earth Observing System (EOS) are being studied. Atmospheric experiments which are being analyzed include nadir-viewing sounders, limb-emission scanners, laser systems, and solar-occultation techniques.

Harrison, Edwin F.↗

Fabrication, Metrology and Modeling of the Space-Based Lidar Telescope for SPARCLE

Over the past 7 years, NASA Marshall Space Flight Center (MSFC) through the Global Hydrology and Climate Center (GHCC) has been working; in collaboration with the University of Alabama in Huntsville (UAH) Center for Applied Optics (CAO), and others; towards demonstrating a solid state coherent Doppler lidar instrument for space-based global measurement of atmospheric winds. The Space Readiness Coherent Lidar Experiment (SPARCLE) was selected by NASA's New Millennium Program to demonstrate the feasibility and technology readiness of space-based coherent wind lidar. The CAO was responsible for the design, development, integration, and testing of the SPARCLE optical system. Operating at 2-micron wavelength, SPARCLE system performance is dominated by the optical quality of the transmitter/receiver optical system. The stringent optical performance requirements coupled with the demanding physical and environmental constraints of a space-based instrument necessitate extensive characterization of the telescope optical performance that is critical to predicting the lidar system efficiency and operation in space. Individual components have been measured prior to assembly and compared to the designed specifications. Based on the individual components, the telescope design was optimized to produce a suitable telescope. Once the telescope is completed, it will be tested and evaluated and the data shall be used to anchor computer based models of the optical system. Commercial optical modeling codes were used to evaluate the performance of the telescope under a variety of anticipated on-orbit environments and will eventually be compared to environmental tests conducted in the course of qualifying the telescope for flight. Detailed analysis using the "as built" data will help to reduce uncertainties within the lidar system model and will increase the accuracy of the lidar performance predictions.

Peters, Bruce R.↗