At least 1,207 records · Page 67

Molecular signatures in response to Isoliquiritigenin in lymphoblastoid cell lines

Highlights: Black-Right-Pointing-Pointer We identified the inhibitory effect of ISL on cell proliferation of LCLs. Black-Right-Pointing-Pointer We found ISL-induced genes and miRNAs through microarray approach. Black-Right-Pointing-Pointer ISL-treated LCLs represented gene expression changes in cell cycle and p53 pathway. Black-Right-Pointing-Pointer We revealed 12 putative mRNA-miRNA functional pairs associated with ISL effect. -- Abstract: Isoliquiritigenin (ISL) has been known to induce cell cycle arrest and apoptosis of various cancer cells. However, genetic factors regulating ISL effects remain unclear. The aim of this study was to identify the molecular signatures involved in ISL-induced cell death of EBV-transformed lymphoblastoid cell lines (LCLs) using microarray analyses. For gene expression and microRNA (miRNA) microarray experiments, each of 12 LCL strains was independently treated with ISL or DMSO as a vehicle control for a day prior to total RNA extraction. ISL treatment inhibited cell proliferation of LCLs in a dose-dependent manner. Microarray analysis showed that ISL-treated LCLs represented gene expression changes in cell cycle and p53 signaling pathway, having a potential as regulators in LCL survival and sensitivity to ISL-induced cytotoxicity. In addition, 36 miRNAs including five miRNAs with unknown functions were differentially expressed in ISL-treated LCLs. The integrative analysis of miRNA and gene expression profiles revealed 12 putative mRNA-miRNA functional pairs. Among them, miR-1207-5p and miR-575 were negatively correlated with p53 pathway- and cell cycle-associated genes, respectively. In conclusion, our study suggests that miRNAs play an important role in ISL-induced cytotoxicity in LCLs by targeting signaling pathways including p53 pathway and cell cycle.

60 APPLIED LIFE SCIENCES↗

Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Controlled reversal of Co/Pt Dots for nanomagnetic logic applications

Domain reversal in perpendicular multilayer films is governed by an intrinsic distribution of anisotropy. However, control of the switching field distribution (SFD) of field-coupled, single domain Co/Pt dots is the key to building large integrated systems for nanomagnetic logic applications. In this work, partial Ga{sup +} focused ion beam (FIB) irradiation of single-domain Co/Pt dots is employed which locally reduces the anisotropy and renders the film-inherent SFD ineffective. Controlled reduction in the switching field compared to non-irradiated dots is achieved, depending on size and dose of irradiation. TEM images of an as-grown and irradiated Co/Pt stack show a change in morphology from distinct Co/Pt interfaces to intermixed and randomly oriented grains due to the Ga{sup +} ion impact. The presented method is highly suitable to control the switching behavior in field-coupled logic devices. Experimental results are used to demonstrate a nanomagnetic fanout operation.

36 MATERIALS SCIENCE↗

SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro experiments. All those developments will be released publicly. This work was supported by grants from Plan Cancer 2009-2013 French national initiative managed by INSERM (Institut National de la Sante et de la Recherche Medicale)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Milestone 1.2.10: Steady-state H 2 “roll over” point data for aluminum alloys 1100 and 6061

Extended (> 50 years) dry storage is being evaluated by the U.S. Department of Energy (DOE) for the disposition of ~ 18 metric tons of aluminum-clad spent nuclear fuel (ASNF). Transition of the current ASNF inventory into dry storage—using the standard DOE canister—necessitates a rigorous, predictive understanding of the long-term physical and chemical factors that may influence the integrity of the proposed storage canister, including radiolytic molecular hydrogen (H 2 ) generation. Current model predictions employ initial radiolytic yields of H 2 , the values of which change as the cladding’s H 2 -precursor inventory is depleted and H 2 itself becomes progressively more involved in radiolytic and surface dissociation processes. Consequently, the absorbed radiation dose that this steady-state H 2 yield corresponds to is essential for the evaluation and improvement of model predictions. Here, we report our findings on the long-term generation of H 2 from the gamma irradiation (≤ 36 MGy) of corroded AA1100 and AA6061 coupons in helium environments at ambient temperature and ~ 50% RH. Our findings show that AA1100 systems reached steady-state by ~ 36 MGy, while higher doses were necessary for AA6061 systems. This discrepancy was attributed to the AA6061 coupons developing a thicker corrosion layer that led to the trapping of H 2 and its precursors, and potentially additional chemistries, ultimately delaying the depletion of H 2 precursors and the system’s “roll over” point. Further, current model predictions—based on previous AA1100 data—do not show steady-state attainment until above 120 MGy, which is not the case for the AA1100 data collected here. Consequently, the new alloy dependent data presented here are important for the continued improvement of predictive computer models for evaluating the feasibility of extended storage of ASNF in helium backfilled canisters.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Possible effects of protracted exposure on the additivity of risks from space radiations

Conventional radiation risk assessments are presently based on the additivity assumption. This assumption states that risks from individual components of a complex radiation field involving many different types of radiation can be added to yield the total risk of the complex radiation field. If the assumption is not correct, the summations and integrations performed to obtain the presently quoted risk estimates are not appropriate. This problem is particularly important in the area of space radiation risk evaluation because of the many different types of high- and low-LET radiation present in the galactic cosmic ray environment. For both low- and high-LET radiations at low enough dose rates, the present convention is that the addivity assumption holds. Mathematically, the total risk, Rtot is assumed to be Rtot = summation (i) Ri where the summation runs over the different types of radiation present. If the total dose (or fluence) from each component is such that the interaction between biological lesions caused by separate single track traversals is negligible within a given cell, it is presently considered to be reasonable to accept the additivity assumption. However, when the exposure is protracted over many cell doubling times (as will be the case for extended missions to the moon or Mars), the possibility exists that radiation effects that depend on multiple cellular events over a long time period, such as is probably the case in radiation-induced carcinogenesis, may not be additive in the above sense and the exposure interval may have to be included in the evaluation procedure. It is shown, however, that "inverse" dose-rate effects are not expected from intermediate LET radiations arising from the galactic cosmic ray environment due to the "sensitive-window-in-the-cell-cycle" hypothesis.

NASA Discipline Number 45-10↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine

Purpose: The objective of the present work was to propose a design of a secondary multileaf collimator (MLC) for a telecobalt machine and optimize its design features through Monte Carlo simulation. Methods: The proposed MLC design consists of 72 leaves (36 leaf pairs) with additional jaws perpendicular to leaf motion having the capability of shaping a maximum square field size of 35 Multiplication-Sign 35 cm{sup 2}. The projected widths at isocenter of each of the central 34 leaf pairs and 2 peripheral leaf pairs are 10 and 5 mm, respectively. The ends of the leaves and the x-jaws were optimized to obtain acceptable values of dosimetric and leakage parameters. Monte Carlo N-Particle code was used for generating beam profiles and depth dose curves and estimating the leakage radiation through the MLC. A water phantom of dimension 50 Multiplication-Sign 50 Multiplication-Sign 40 cm{sup 3} with an array of voxels (4 Multiplication-Sign 0.3 Multiplication-Sign 0.6 cm{sup 3}= 0.72 cm{sup 3}) was used for the study of dosimetric and leakage characteristics of the MLC. Output files generated for beam profiles were exported to the PTW radiation field analyzer software through locally developed software for analysis of beam profiles in order to evaluate radiation field width, beam flatness, symmetry, and beam penumbra. Results: The optimized version of the MLC can define radiation fields of up to 35 Multiplication-Sign 35 cm{sup 2} within the prescribed tolerance values of 2 mm. The flatness and symmetry were found to be well within the acceptable tolerance value of 3%. The penumbra for a 10 Multiplication-Sign 10 cm{sup 2} field size is 10.7 mm which is less than the generally acceptable value of 12 mm for a telecobalt machine. The maximum and average radiation leakage through the MLC were found to be 0.74% and 0.41% which are well below the International Electrotechnical Commission recommended tolerance values of 2% and 0.75%, respectively. The maximum leakage through the leaf ends in closed condition was observed to be 8.6% which is less than the values reported for other MLCs designed for medical linear accelerators. Conclusions: It is concluded that dosimetric parameters and the leakage radiation of the optimized secondary MLC design are well below their recommended tolerance values. The optimized design of the proposed MLC can be integrated into a telecobalt machine by replacing the existing adjustable secondary collimator for conformal radiotherapy treatment of cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-570: Management of Radiation Oncology Patients with Cochlear Implant and Other Bionic Devices in the Brain and Head and Neck Regions

Purpose: To investigate the current status of clinical usage of cochlear implant (CI) and other bionic devices (BD) in the brain and head and neck regions (BH and N) and their management in patients during radiotherapy to ensure patient health and safety as well as optimum radiation delivery. Methods: Literature review was performed with both CIs and radiotherapy and their variants as keywords in PubMed, INSPEC and other sources. The focus was on CIs during radiotherapy, but it also included other BDs in BHȦN, such as auditory brainstem implant, bionic retinal implant, and hearing aids, among others. Results: Interactions between CIs and radiation may cause CIs malfunction. The presence of CIs may also cause suboptimum dose distribution if a treatment plan was not well designed. A few studies were performed for the hearing functions of CIs under irradiations of 4 MV and 6 MV x-rays. However, x-rays with higher energies (10 to 18 MV) broadly used in radiotherapy have not been explored. These higher energetic beams are more damaging to electronics due to strong penetrating power and also due to neutrons generated in the treatment process. Modern CIs are designed with more and more complicated integrated circuits, which may be more susceptible to radiation damage and malfunction. Therefore, careful management is important for safety and treatment outcomes. Conclusion: Although AAPM TG-34, TG-63, and TG-203 (update of TG-34, not published yet) reports may be referenced for management of CIs and other BDs in the brain and H and N regions, a site- and device-specified guideline should be developed for CIs and other BDs. Additional evaluation of CI functions under clinically relevant set-ups should also be performed to provide clinicians with better knowledge in clinical decision making.

60 APPLIED LIFE SCIENCES↗

TEM Approaches for Microstructure-Informed Prediction of Mechanical Properties in Structural Alloys

Predicting the mechanical performance of structural alloys from their evolving microstructure remains a major challenge in materials science, particularly for nuclear structural materials, where irradiation-induced defects span multiple types and length scales and interact through complex mechanisms. The dispersed barrier hardening (DBH) [1] and Friedel–Kroupa–Hirsch (FKH) [2,3] models have been widely used to evaluate the hardening contributions of individual obstacles and to estimate tensile strength from quantified microstructures; however, when multiple size-dependent obstacles coexist and evolve, predicting temperature-dependent tensile strength becomes significantly more complex, and a fully consistent hardening model is still lacking. Transmission electron microscopy (TEM) plays a central role in refining hardening models and enabling predictive assessments of tensile strength evolution by providing quantitative characterization of dislocations, irradiation-induced defects (e.g., dislocation loops and cavities), precipitates, and grain structure (Fig. 1.). These experimentally measured defect densities are incorporated into physically based hardening models with size- and shape- dependent obstacle strengths [4], using root-sum-square superposition for obstacles of comparable strength and linear superposition for dissimilar ones [5]. In addition, recent advances in TEM [6-8], including high-resolution imaging, 4D-STEM strain mapping, EDS/EELS elemental analysis, and flash-polishing-based TEM specimen preparation and extraction-replica methods (Fig. 2), further improve the accuracy of microstructural quantification. By comparison with prior studies as well as our own results, we show that when TEM-derived microstructural information is carefully integrated with physically grounded hardening models, yield strength (or irradiation-induced hardening) measured at room temperature can be predicted with good quantitative agreement across multiple alloy classes. In-situ TEM combined with high-temperature mechanical testing represents an important next step for refining hardening models by directly probing dislocation–obstacle interactions across varying irradiation doses and temperatures [9]. Because the barrier strength factor (α) depends on both temperature and obstacle size, it should not be treated as a constant fitting parameter; rather, it must be explicitly evaluated to achieve physically meaningful predictions of mechanical behaviour at operating temperatures. This presentation therefore discusses why all strengthening contributions (e.g., Peierls stress, solid-solution strengthening, voids, bubbles, dislocation loops, dislocation lines, and grain boundaries) must be considered collectively, why appropriate superposition methods are essential when obstacles possess different barrier strength factors, how hardness measurements can be meaningfully related to tensile properties, and how TEM-derived microstructural information can be systematically incorporated into hardening models. More broadly, it outlines a pathway toward microstructure-informed prediction of mechanical properties and supports the goal of establishing science-based tools for evaluating structural materials in extreme environments [10].

Lin, Yan-Ru [ORNL] (ORCID:0000000339991473)↗

Better Radiation Response and Accident Tolerance of Nanostructured Ceramic Fuel Materials?

The objective of this research is to study structural stability and fission product behavior in nanostructured ZrO 2 and CeO 2 at temperatures and irradiation conditions relevant to operation and accidental scenarios. The fundamental understanding will support the development of innovative fuel forms. Specifically, the proposed work employs novel ion irradiation approaches, complementary characterization techniques, and advanced simulation methods to perform separate and integrated effect studies that expand the fundamental understanding of: Task (1) damage evolution in ceramic fuel materials in a controlled irradiation environment with focus in the transition energy regime where simultaneous energy deposition to both atomic and electronic structures is significant; Task (2) phase and structural stability in nanostructured fuel materials to high-temperature high-dose irradiation; and Task (3) role of the grain boundaries, surface/interface properties on migration and segregation of fission products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PROTEC TM TEAR-OFFS: RESULTS OF LONG TERM TESTING

The Savannah River National Laboratory (SRNL) has completed a series of tests (Phases 1 and 2) to assess the potential use of a Mylar{reg_sign} tear-off system as a primary or secondary protective barrier to minimize acid etching ('frosting'), accidental scratching, and/or radiation damage for shielded cells, glovebox, and/or chemical hood windows. Conceptually, thin, multi-layered sheets of Mylar (referred to throughout this report as the ProTec{trademark} tear-off system) can be directly applied to the shielded cell, glovebox, or hood sash window to serve as a secondary (or primary) barrier. Upon degradation of visual clarity due to accidental scratching, spills/splatters, and/or radiation damage, the outer layer (or sheet) of Mylar could be removed refreshing or restoring the view. Due to the multilayer aspect, the remaining Mylar layers would provide continued protection for the window from potential reoccurrences. Although the concept of using a tear-off system as a protective barrier is conceptually enticing, potential technical issues were identified and addressed as part of this phased study to support implementation of this type of system in the Defense Waste Processing Facility (DWPF). Specific test conditions of interest to the DWPF included the performance of the tear-off system exposed to or under the following conditions: (1) acid(s) (concentrated (28.9 M) HF, concentrated (15.9M) HNO{sub 3}, 6M HCl, and 0.6M H{sub 3}BO{sub 3}); (2) base (based on handling of radioactive sludges with pH of {approx}12-13); (3) gamma radiation (due to radioactive sources or materials being used in the analytical cells); (4) scratch resistance (simulating accidental scratching with the manipulators); and (5) in-situ testing (sample coupons exposed to actual field conditions in DWPF). The results of the Phase 1 study indicated that the ProTec tear-off concept (as a primary or secondary protective barrier) is a potential technical solution to prevent or retard excessive damage that would result from acid etching, base damage (as a result of a sludge spill or splatter), gamma radiation damage, and/or accidental scratching (due to manipulator/tool contact). Although identified as a potential solution, the Phase 1 testing was relatively short-term with exposure times up to 1-2 months for the acid and gamma radiation tests. Phase 2 testing included longer exposure times for the acid resistance (up to 456 days) and gamma radiation exposure (700 days with a cumulative gamma dose of {approx}3.1 x 10{sup 5} rad) assessments. The tear-off system continued to perform well in these longer-term acid resistance testing and gamma exposure conditions. Complete removal of the tear-offs after these long-term exposure times indicate that not only could visual clarity be restored but the mechanical integrity could be retained. The results also provided insight into the ability of the ProTec tear-off system to withstand the chemical and physical abuses expected in off-normal shielded cells operations. The conceptual erasing of scratches or marks by excessive manipulator abuse was demonstrated in the SRNL Shielded Cells mock-up facility through the removal of the outer layer tear-off with manipulators. In addition, the Phase 2 testing included an in-situ assessment of a prototype tear-off system in the DWPF Sampling Cells where the system was exposed to actual field conditions including radioactive sources, acidic and basic environments, dusting, and chemical cleaning solutions over a 5-6 month period. DWPF personnel were extremely satisfied with the performance (including the successful removal of 3 layers with manipulators) of the ProTec tear-off system under actual field conditions. The successful removal of the outer layer tear-offs with the manipulator, using tabs not specifically designed for remote operations, demonstrates that the system is 'manipulator-friendly' and could be implemented in a remote environment. The ability to remove the outer layer tear-off not only regains visual clarity but also reduces waste disposal volumes (i.e., disposal of a thin sheet of Mylar which is 'collapsible' versus the bulk disposal of a rigid Lexan{reg_sign} sheet (alpha shield) or glovebox/sash window) which is more cost effective. The tear-off system could also reduce the number of cell entries needed to replace the Lexan sheet and increase the time interval between glovebox/sash window replacements, which can be costly and time consuming. Although the primary focus of this study addresses the application of the ProTec tear-off system to shielded cells windows, the concept is also potentially applicable to glovebox and hood sash windows. In fact, the tear-off concept is potentially applicable to any system where visual clarity is compromised given the environmental conditions of the test. In addition, the tear-offs could be applied to walls or shelves where a protective barrier would reduce deterioration or discoloration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Data Quality Objectives in Decommissioning Plans

The Data Quality Objectives (DQOs) are applicable and relevant in the design of measurements that provide data for good, effective decision-making. The DQOs provide criteria for the design of measurements and provide a target for assessing the level of data quality that is considered acceptable for effective decision-making. Such targets in the design of measurements help eliminate the acquisition of unnecessary, duplicative or overly precise data. They help provide more efficient use of limited measurement resources. With the application of DQOs, D and D program decisions are identified, DQOs are established, and measurements are designed to provide data that meet the DQOs for each decision point. Since the Historical Site Assessment (HSA), Scoping, Characterization, and Remedial Action Surveys provide data and information to all D and D program decision-making, an integrated approach should be taken where all input requirements are considered, in the design of each survey. The decision points and their linkages form a network of decisions referred to as a decision framework. Since distinct D and D program functions are linked by their decisions, programs proceed through the decision framework, in a uniform fashion, to one endpoint, the decision to release the site. The decision to release the site is based on the ability to pass the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). Therefore, D and D planning has a primary aim, to integrate D and D program efforts in a manner that will allow D and D decision-making to reach one end point, effective MARSSIM decision-making. The Decision Framework is best represented, schematically, by a decision tree. The decision tree is based on 3- decision points and represents a decision in each of the Remediation, Dose Assessment and MARSSIM program functions. The decisions address the extent of excavation, dose modeling approach, and sampling for the MARSSIM Final Status Survey (FSS). The simplified decision rule established for each decision point relies on the questions: deep excavation or not; site-specific modeling or not; and high number of samples or not. For these decision rules, the basic outcomes are yes or no to the questions. As decision-makers proceed through the decision tree, there are 8 different paths available based on the theoretical relationship 2N, where N=3. All the paths lead to the one-end point, MARSSIM decision-making. Data and information from pre-release surveys provide input to each decision (although not illustrated in the decision tree schematic). Here MARSSIM represents a legitimate D and D program with decision-making functions. Since D and D decisions are connected to MARSSIM decisions, as illustrated in the decision tree, D and D decision-making can be captured in the MARSSIM context and the decision tree included in the MARSSIM report. These weighted options were selected because they represent 3-alternate plans (strategies) that could be implemented with equivalent total resources (costs). Hypothetical costing for each D and D program function is indicated at each section of the paths in terms of normalized values 10 and 1, in arbitrary units. Option 1 describes a path where Deep Excavation, Site specific Modeling, and a Low Number of Samples for the FSS are the bases. Option 2 describes a path where Deep Excavation, Screening Values, and a High Number of Samples are the bases. Option 3 utilizes Shallow Excavation, Site-specific Modeling, and a High Number of Samples in the FSS design. Since the 3-options are equivalent in costs, the selection of the best D and D option or MARSSIM Plan for the site could be determined by other factors such as Waste Management, Health and Safety, or Regulatory Compliance. For example, a site with Health and Safety issues may want to utilize Option 3, so that cleanup worker exposure is minimized during excavation. A small site, that has limited technical support, may want to use tables of screening values for dose assessments, and therefore Option 2 may be an appropriate MARSSIM Plan. Another example would be a case for the use of Option 1 where the D and D manager may want to minimize difficulties with getting pass MARSSIM tests. By conducting extensive cleanup and calculating more realistic (less conservative) dose values, more flexibility in MARSSIM is obtained. for any decision framework, there are a number of reasonable paths to be considered in D and D decision-making and that these paths can be viewed as a family of MARSSIM Plans. Optimization of MARSSIM decision-making can occur by selecting, from this family of MARSSIM Plans, the most appropriate plan for the conditions at a specific site. This approach represents a more comprehensive evaluation of D and D options and strategies that regulators and stakeholders would most likely appreciate in the MARSSIM Final Report. In an era of information management, it would be prudent to take advantage of opportunities offered by the application of DQOs and the utilization of its decision-framework. The example utilized of a decision framework, is an overly simplified (N=3) model and is presented for illustrative purposes. A typical D and D project would have many more decision points to consider in formulating the decision framework and its decision tree, and the use of high level computing would be needed.

99 GENERAL AND MISCELLANEOUS↗

Physics Contributions and Clinical Outcome With 3D-MRI-Based Pulsed-Dose-Rate Intracavitary Brachytherapy in Cervical Cancer Patients

Purpose: To assess the physics contributions and clinical outcome with three-dimensional magnetic resonance imaging-guided pulsed-dose-rate (PDR) intracavitary brachytherapy in cervical cancer patients. Methods and Materials: The data from 45 patients with primary locally advanced cervical carcinoma were analyzed. The median tumor cervical volume was 64.0 cm{sup 3} (range, 3-178). Of the 45 patients, 24 (53%) had histologic and/or radiologic pelvic involvement. After pelvic with or without para-aortic concomitant chemoradiotherapy, a PDR brachytherapy boost was delivered to a three-dimensional magnetic resonance imaging-based clinical target volume, taking into account the dose-volume constraints for critical organs and optimization of the target volume coverage. Results: At a median follow-up of 26 months (range, 9-47), the 2-year overall survival and disease-free survival rate was 78% and 73%, respectively. At the last follow-up visit, the disease of all patients remained locally controlled. Adding external beam radiotherapy and PDR using the equivalent dose in 2-Gy fractions model, the median dose received by 100% and 90% of the target was 54.4 Gy{sub {alpha}}{sub /{beta}}{sub 10} and 63.5 Gy{sub {alpha}}{sub /{beta}}{sub 10} for the intermediate-risk clinical target volume and 61.6 Gy{sub {alpha}}{sub /{beta}}{sub 10} and 74.9 Gy{sub {alpha}}{sub /{beta}}{sub 10} for the high-risk clinical target volume, respectively. Of the 45 patients, 23 and 2 developed acute Grade 1-2 and Grade 3 complications, respectively; 21 patients presented with delayed Grade 1-2 complications. One other patient presented with Grade 3 vesicovaginal fistula. No Grade 4 or greater complications, whether acute or delayed, were observed. Conclusion: Magnetic resonance imaging-guided PDR brachytherapy with optimization integrating the limits of tolerance to critical organs allows for excellent local control rates. Moreover, the present results have confirmed that the ability to optimize dwell times can contribute to an improvement in local control rates with a low level of late side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-233: Evaluation of Treatment Delivery Parameters Using High Resolution ELEKTA Log Files

Purpose: As modern linacs have become more technologically advanced with the implementation of IGRT and IMRT with HDMLCs, a requirement for more elaborate tracking techniques to monitor components’ integrity is paramount. ElektaLog files are generated every 40 milliseconds, which can be analyzed to track subtle changes and provide another aspect of quality assurance. This allows for constant monitoring of fraction consistency in addition to machine reliability. With this in mind, it was the aim of the study to evaluate if ElektaLog files can be utilized for linac consistency QA. Methods: ElektaLogs were reviewed for 16 IMRT patient plans with >16 fractions. Logs were analyzed by creating fluence maps from recorded values of MLC locations, jaw locations, and dose per unit time. Fluence maps were then utilized to calculate a 2D gamma index with a 2%–2mm criteria for each fraction. ElektaLogs were also used to analyze positional errors for MLC leaves and jaws, which were used to compute an overall error for the MLC banks, Y-jaws, and X-jaws by taking the root-meansquare value of the individual recorded errors during treatment. Additionally, beam on time was calculated using the number of ElektaLog file entries within the file. Results: The average 2D gamma for all 16 patient plans was found to be 98.0±2.0%. Recorded gamma index values showed an acceptable correlation between fractions. Average RMS values for MLC leaves and the jaws resulted in a leaf variation of roughly 0.3±0.08 mm and jaw variation of about 0.15±0.04 mm, both of which fall within clinical tolerances. Conclusion: The use of ElektaLog files for day-to-day evaluation of linac integrity and patient QA can be utilized to allow for reliable analysis of system accuracy and performance.

60 APPLIED LIFE SCIENCES↗

Progress Towards Prolonged Deployment of SiC JFET-R ICs Into Previously Inaccessible Hostile Environments

This invited presentation describes demonstration of semiconductor integrated circuits (ICs) and ceramic packaging that are arguably the most environmentally durable transistor electronics ever demonstrated. SiC junction field effect transistor-resistor (JFET-R) ICs with two-level interconnect have successfully operated for over 1 year in 500 °C air-ambient [1], 60 days in 460 °C and 9.3 MPa pressure caustic Venus surface environment test chamber [2], and radiation exposure through 7 Mrad(Si) total ionizing dose (TID) and 86 MeV-cm2/mg heavy ion strikes [3]. Furthermore, these ICs have also demonstrated operation from -190 °C to +812 °C (over 1000 °C T-span) without significant change in signal (input /output) or power supply voltages [4]. With modest adjustments, the SiC JFET-R fabrication process is compatible with semiconductor mass-production tools and materials. As an initial step towards this end, the processing that forms the SiC JFETs and resistors (without interconnect) for the NASA Glenn “Generation 12” design prototype JFET-R ICs was conducted at GE Research. Once the COVID-delayed IC interconnect and bond pad fabrication processing on these wafers is completed at NASA Glenn, the resulting chips will be packaged and oven-tested [5]. It is expected that further technology transfer to complete commercial production will lower investment and risk barriers to useful application deployment. For NASA, an initial high-value deployment is opening the Venus surface to extended missions for robotic scientific exploration.

Silicon Carbide↗

Evaluation of Robustness to Setup and Range Uncertainties for Head and Neck Patients Treated With Pencil Beam Scanning Proton Therapy

Purpose: To evaluate the robustness of head and neck plans for treatment with intensity modulated proton therapy to range and setup errors, and to establish robustness parameters for the planning of future head and neck treatments. Methods and Materials: Ten patients previously treated were evaluated in terms of robustness to range and setup errors. Error bar dose distributions were generated for each plan, from which several metrics were extracted and used to define a robustness database of acceptable parameters over all analyzed plans. The patients were treated in sequentially delivered series, and plans were evaluated for both the first series and for the combined error over the whole treatment. To demonstrate the application of such a database in the head and neck, for 1 patient, an alternative treatment plan was generated using a simultaneous integrated boost (SIB) approach and plans of differing numbers of fields. Results: The robustness database for the treatment of head and neck patients is presented. In an example case, comparison of single and multiple field plans against the database show clear improvements in robustness by using multiple fields. A comparison of sequentially delivered series and an SIB approach for this patient show both to be of comparable robustness, although the SIB approach shows a slightly greater sensitivity to uncertainties. Conclusions: A robustness database was created for the treatment of head and neck patients with intensity modulated proton therapy based on previous clinical experience. This will allow the identification of future plans that may benefit from alternative planning approaches to improve robustness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗