Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Crab Cavity RF Design – Phase 1

The design and construction of electron-ion colliders, EIC, will be facilitated by the development of an SRF “crab crossing” cavity with 0.5 to 1.5 GHz frequency and 20 to 50 MV of total integrated voltage. The development of RF cavities that provide a transverse kick to the particle beam will include RF design, computer modeling, and hardware development. Current state of the art crab cavities provide 2- 5 MV of integrated voltage, and most of the existing designs require complex schemes to damp unwanted RF modes. We propose a novel design for TEM-like, room-temperature, two-bar structures, or hybrid structures with one resonant bar and one input coax per module, which can also be implemented for SRF conditions. Unwanted modes are coupled out of the cavity by the coax input line, and this provides a uniquely simple method to reduce the strength of higher-order modes. Critical phase stability for the crabbing voltage is provided by the low-level RF system, which controls the RF to the input ports of the novel crab cavity design. Designs for a series of cavities, or for multiple-module cavities, will provide the 20-50 MV of integrated voltage in an electron-ion collider, while meeting the critical thermal and mechanical requirements for heat loads, alignment, and phase stability. RF designs for various module alternatives were evaluated in Phase I. A single module of a hybrid design with one resonant bar and one coax input was built for room-temperature, low-power testing with a bead-pull measurement. Several additional designs were explored that made use of a high RT/Q, voltage-efficient, S-mode structure.

Neubauer, Michael↗

Flexible Residential Test Facility: Impact of Infiltration and Ventilation on Measured Cooling Season Energy and Moisture Levels

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture Preliminary Techno-Economic Analysis

This report presents system and economic analysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO{sub 2} capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO{sub 2} for the aminosilicone-based carbon-capture process is $46.04/ton of CO2 as compared to $60.25/ton of CO{sub 2} when MEA is used. The aminosilicone-based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO{sub 2} decreases to $44.12/ton. The aminosilicone-based solvent has a higher thermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lower vapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lower heat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

54 ENVIRONMENTAL SCIENCES↗

Micro-scale heat-exchangers for Joule-Thomson cooling.

This project focused on developing a micro-scale counter flow heat exchangers for Joule-Thomson cooling with the potential for both chip and wafer scale integration. This project is differentiated from previous work by focusing on planar, thin film micromachining instead of bulk materials. A process will be developed for fabricating all the devices mentioned above, allowing for highly integrated micro heat exchangers. The use of thin film dielectrics provides thermal isolation, increasing efficiency of the coolers compared to designs based on bulk materials, and it will allow for wafer-scale fabrication and integration. The process is intended to implement a CFHX as part of a Joule-Thomson cooling system for applications with heat loads less than 1mW. This report presents simulation results and investigation of a fabrication process for such devices.

Gross, Andrew John↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture

This report presents system and economicanalysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO₂ capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. Forcomparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO₂ for the aminosilicone-based carbon-capture process is $46.04/ton of CO₂ as compared to $60.25/ton of CO₂ when MEA is used. The aminosilicone- based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO₂ decreases to $44.12/ton. The aminosilicone-based solvent has a higherthermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lowervapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lowerheat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages overconventional systems using MEA.

Singh, Surinder↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-06100

Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-06100. This package was selected for examination based on several characteristics: - This was the first destructively examined package in which the fiberboard assembly was fabricated from softwood fiberboard. - The package contained a relatively high heat load to contribute to internal temperature, which is a key environmental factor for fiberboard degradation. - The package has been stored in the middle or top of a storage array since its receipt in K- Area, positions that would contribute to increased service temperatures. No significant changes were observed for attributes that were measured during both field surveillance and destructive examination. Except for the axial gap, all observations and test results met identified criteria, or were collected for information and trending purposes. The axial gap met the 1 inch maximum criterion during field surveillance, but was just over the criterion during SRNL measurements. When re-measured at a later date, it again met the criterion. The bottom of the lower fiberboard assembly and the drum interior had two small stains at matching locations, suggestive of water intrusion. However, the fiberboard assembly did not contain any current evidence of excess moisture. No evidence of a degraded condition was found in this package. Despite exposure to the elevated temperatures of this higher-then-average wattage package, properties of the fiberboard and O-rings are consistent with those of new packages.

42 ENGINEERING↗

EXAMINATION OF SHIPPING PACKAGE 9975-05050

Shipping package 9975-05050 was examined in K-Area following its identification as a high wattage package. Elevated temperature and fiberboard moisture content are key parameters that impact the degradation rate of fiberboard within 9975 packages in a storage environment. The high wattage of this package contributes significantly to component temperatures. After examination in K-Area, the package was provided to SRNL for further examination of the fiberboard assembly. The moisture content of the fiberboard was relatively low (compared to packages examined previously), but the moisture gradient (between fiberboard ID and OD surfaces) was relatively high, as would be expected for the high heat load. The cane fiberboard appeared intact and displayed no apparent change in integrity relative to a new package.

42 ENGINEERING↗

Identification of Process Suitable Diluent

The Sigma Team for Minor Actinide Separation (STMAS) was formed within the USDOE Fuel Cycle Research and Development (FCRD) program in order to develop more efficient methods for the separation of americium and other minor actinides (MA) from used nuclear fuel. The development of processes for MA separations is driven by the potential benefits; reduced long-term radiotoxicty of waste placed in a geologic repository, reduced timeframe of waste storage, reduced repository heat load, the possibility of increased repository capacity, and increased utilization of energy potential of used nuclear fuel. The research conducted within the STMAS framework is focused upon the realization of significant simplifications to aqueous recycle processes proposed for MA separations. This report describes the research efforts focused upon the identification of a process suitable diluent for a flowsheet concept for the separation of MA which is based upon the dithiophosphinic acid (DPAH) extractants previously developed at the Idaho National Laboratory (INL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Partnership for Edge Physics Simulation (EPSI)

We propose to develop advanced simulation codes, based upon an extreme parallelism, first principles kinetic approach, to address the challenges associated with the edge region of magnetically confined plasmas. This work is relevant to both existing magnetic fusion facilities and essential for next-generation burning plasma experiments, such as ITER where success is critically dependent upon H-mode operation achieving an edge pedestal of sufficient height for good core plasma performance without producing deleterious large scale edge localized instabilities. The plasma edge presents a well-known set of multi-physics, multi-scale problems involving complex 3D magnetic geometry. Perhaps the greatest computational challenge is the lack of scale separation – temporal scales for drift waves, Alfven waves, ELM dynamics for example have strong overlap. Similar overlap occurs on the spatial scales for the ion poloidal gyro-radius, drift wave and pedestal width. The traditional approach of separating fusion problems into weakly interacting spatial or temporal domains clearly breaks down in the edge. A full kinetic model (full-f model) must be solved to understand and predict the edge physics including non-equilibrium thermodynamic issues arising from the magnetic topology (the open field lines producing a spatially sensitive velocity hole), plasma wall interactions, neutral and atomic physics. The plan here is to model these phenomena within a comprehensive first principles set of equations without the need for the insurmountable multiple-codes coupling issues by building on the XGC1 code developed under the SciDAC Proto-FSP Center for Plasma Edge Simulation (CPES). This proposal includes the critical participants in the XGC1 development. We propose enhancing the capability of XGC1 by including all the important turbulence physics contained in kinetic ion and electron electromagnetic dynamics, by extending the PIC technology to incorporate several positive features found in the Eulerian grid technology, combining the coarse grained XGC0 code into it with a multiscale projective time integration technique to be developed in the project for experimental time scale simulation of the edge multi-physics, and by implementing modern computational technologies to move forward with the extreme scale heterogeneous hardware/software platform development. Ultra-fast edge localized instabilities, involving compressional Alven modes, will be studied using a proper MHD or two-fluid codes employing kinetic closure information from XGC. The proposed research integrates the most important physical processes on overlapping temporal and spatial scales, to study (i) transitions and thresholds for enhanced confinement regimes, (ii) the predictive understanding of the edge pedestal formation, structure and dynamics, (iii) the effect of the edge plasma on the core confinement, (iv) the physics of Edge Localized Modes and their suppression or mitigation via external control techniques, and (v) the heat load on the material wall. Our approach will implement physical models that are valid in their relevant collisionality regimes for current experiments and future burning plasma devices. Comparisons with experimental data will be made at multiple levels including characterization of turbulence dynamics, flux-gradient responses in the energy, particle and momentum channels, and observations of global phenomena such as L-H transitions, momentum generation, ELM dynamics, ELM-free regimes and the tokamak density limit. The proposal team has established strong connections, through joint membership, with other organizations that will be critical for success. These include FASTMath, SUPER and QUEST Institutes respectively for meshing tools and solvers; code performance tuning and uncertainty quantification as well as a proposed Data Management and Visualization Institute.. We will also be teaming with ongoing fusion SciDAC’s: CSWPI for RF-edge plasmas interactions; CEMM for the M3D MHD simulations and with PEPSC for incorporation of energetic particle physics. Finally, the team includes representatives from each of the major U.S. experimental facilities who will coordinate the validation program and the development of synthetic diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Investigation of Turbine Vane Heat Transfer for Alternative Fuels

The focus of this program was to experimentally investigate advanced gas turbine cooling schemes and the effects of and factors that contribute to surface deposition from particulate matter found in coal syngas exhaust flows on turbine airfoil heat transfer and film cooling, as well as to characterize surface roughness and determine the effects of surface deposition on turbine components. The program was a comprehensive, multi-disciplinary collaborative effort between aero-thermal and materials faculty researchers and the Department of Energy, National Energy Technology Laboratory (NETL). The primary technical objectives of the program were to evaluate the effects of combustion of syngas fuels on heat transfer to turbine vanes and blades in land-based power generation gas turbine engines. The primary questions to be answered by this investigation were; What are the factors that contribute to particulate deposition on film cooled gas turbine components? An experimental program was performed in a high-temperature and pressure combustion rig at the DOE NETL; What is the effect of coal syngas combustion and surface deposition on turbine airfoil film cooling? Deposition of particulate matter from the combustion gases can block film cooling holes, decreasing the flow of the film coolant and the film cooling effectiveness; How does surface deposition from coal syngas combustion affect turbine surface roughness? Increased surface roughness can increase aerodynamic losses and result in decreased turbine hot section efficiency, increasing engine fuel consumption to maintain desired power output. Convective heat transfer is also greatly affected by the surface roughness of the airfoil surface; Is there any significant effect of surface deposition or erosion on integrity of turbine airfoil thermal barrier coatings (TBC) and do surface deposits react with the TBC in any way to decrease its thermal insulating capability? Spallation and erosion of TBC is a persistent problem in modern turbine engines; and What advancements in film cooling hole geometry and design can increase effectiveness of film cooling in turbines burning high-hydrogen coal syngas due to the higher heat loads and mass flow rates of the core flow? Experimental and numerical investigations of advanced cooling geometries that can improve resistance to surface deposition were performed. The answers to these questions were investigated through experimental measurements of turbine blade surface temperature and coolant coverage (via infrared camera images and thermocouples) and time-varying surface roughness in the NETL high-pressure combustion rig with accelerated, simulated surface deposition and advanced cooling hole concepts, coupled with detailed materials analysis and characterization using conventional methods of Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), 3-D Surface Topography (using a 3-D stylus profilometer). Detailed surface temperatures and cooling effectiveness could not be measured due to issues with the NETL infrared camera system. In collaboration with faculty startup funding from the principal investigator, experimental and numerical investigations were performed of an advanced film cooling hole geometry, the anti-vortex hole (AVH), focusing on improving cooling effectiveness and decreasing the counter-rotating vortex of conventional cooling holes which can entrain mainstream particulate matter to the surface. The potential benefit of this program is in gaining a fundamental understanding of how the use of alternative fuels will effect the operation of modern gas turbine engines, providing valuable data for more effective cooling designs for future turbine systems utilizing alternative fuels.

10 SYNTHETIC FUELS↗

Computational model of miniature pulsating heat pipes

The modeling work described herein represents Sandia National Laboratories (SNL) portion of a collaborative three-year project with Northrop Grumman Electronic Systems (NGES) and the University of Missouri to develop an advanced, thermal ground-plane (TGP), which is a device, of planar configuration, that delivers heat from a source to an ambient environment with high efficiency. Work at all three institutions was funded by DARPA/MTO; Sandia was funded under DARPA/MTO project number 015070924. This is the final report on this project for SNL. This report presents a numerical model of a pulsating heat pipe, a device employing a two phase (liquid and its vapor) working fluid confined in a closed loop channel etched/milled into a serpentine configuration in a solid metal plate. The device delivers heat from an evaporator (hot zone) to a condenser (cold zone). This new model includes key physical processes important to the operation of flat plate pulsating heat pipes (e.g. dynamic bubble nucleation, evaporation and condensation), together with conjugate heat transfer with the solid portion of the device. The model qualitatively and quantitatively predicts performance characteristics and metrics, which was demonstrated by favorable comparisons with experimental results on similar configurations. Application of the model also corroborated many previous performance observations with respect to key parameters such as heat load, fill ratio and orientation.

97 MATHEMATICS AND COMPUTING↗

Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Improved Refractive Focusing Optic

A diamond optic that can both dissipate the heat load while reducing phase profile errors of the beam will allow a more full realization of the benefits of the previous investments in light sources by allowing experiments that depend on high resolution imaging or spacial resolution. Reducing the x-ray spot size on samples will improve the quality of this information leading to better understanding of materials properties. During Phase I, we explored techniques for characterizing and improving the accuracy of the shape of diamond lenses, particularly in the apex of the parabolic curve, in order to make an optic whose optical performance exceeds what is currently available. We made efforts to reduce the lens surface roughness through a variety of dry etching methods. Additional work sought to make compound lenses with shorter focal lengths and to mount the lenses on copper supports by a variety of methods. Lastly, lenses were made and tested on the 1-BM beamline at APS.

42 ENGINEERING↗

Effects of Hot Streak and Phantom Cooling on Heat Transfer in a Cooled Turbine Stage Including Particulate Deposition

The objective of this research effort was to develop a validated computational modeling capability for the characterization of the effects of hot streaks and particulate deposition on the heat load of modern gas turbines. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. A 1-year no cost extension request was approved for this effort, so the total duration was 4 years. The research effort succeeded in its ultimate objective by leveraging extensive experimental deposition studies complemented by computational modeling. Experiments were conducted with hot streaks, vane cooling, and combinations of hot streaks with vane cooling. These studies contributed to a significant body of corporate knowledge of deposition, in combination with particle rebound and deposition studies funded by other agencies, to provide suitable conditions for the development of a new model. The model includes the following physical phenomena: elastic deformation, plastic deformation, adhesion, and shear removal. It also incorporates material property sensitivity to temperature and tangential-normal velocity rebound cross-dependencies observed in experiments. The model is well-suited for incorporation in CFD simulations of complex gas turbine flows due to its algebraic (explicit) formulation. This report contains model predictions compared to coefficient of restitution data available in the open literature as well as deposition results from two different high temperature turbine deposition facilities. While the model comparisons with experiments are in many cases promising, several key aspects of particle deposition remain elusive. The simple phenomenological nature of the model allows for parametric dependencies to be evaluated in a straightforward manner. This effort also included the first-ever full turbine stage deposition model published in the open literature. The simulations included hot streaks and simulated vane cooling. The new deposition model was implemented into the CFD model as a wall boundary condition, with various particle sizes investigated in the simulation. Simulations utilizing a steady mixing plane formulation and an unsteady sliding mesh were conducted and the flow solution of each was validated against experimental data. Results from each of these simulations, including impact and capture distributions and efficiencies, were compared and potential reasons for differences discussed in detail. The inclusion of a large range of particle sizes allowed investigation of trends with particle size, such as increased radial migration and reduced sticking efficiency at the larger particle sizes. The unsteady simulation predicted lower sticking efficiencies on the rotor blades than the mixing plane simulation for the majority of particle sizes. This is postulated to be due to the preservation of the hot streak and cool vane wake through the vane-rotor interface (which are smeared out circumferentially in the mixing-plane simulation). The results reported here represent the successful implementation of a novel deposition model into validated vane-rotor flow solutions that include a non-uniform inlet temperature profile and simulated vane cooling.

42 ENGINEERING↗

Utilizing geothermal heat for hydrothermal liquefaction of algae

The distribution of utilizable geothermal reservoirs in the US is concentrated in areas of low population density. In order to increase the scale of geothermal operations, we proposed to develop a modular biofuel production facility that directly uses geothermal heat. By transforming geothermal heat to chemical potential energy (rather than electricity), the scale of existing or new geothermal operations can be increased and distributed to areas of higher population density. Simultaneously, the economics of producing biocrude oil is improved significantly where geothermal heat is used, instead of natural gas-fired systems for providing heat and power. In the Phase I project, we demonstrated that it was economically feasible to sustainably produce a biofuel by integrating geothermal heat. It was found that, for the best case scenario at a scale of 10T(biomass)/hr, it was possible to produce a biofuel for $0.26/L, as compared to crude oil at $0.3/L (current selling price). Ultimately this demonstrates that this technology can be economically sustainable when integrated with geothermal heat. We also demonstrated that the addition of modular biofuel-production technologies can be more profitable for a geothermal plant operator. For 1000kg/day scale, it was found that it could be 2.5 times more profitable for a geothermal plant operator to sell bio-oil rather than electricity (with a waste source within 20 miles of the processing facility). Furthermore, as the design of the proposed technology recycles significant heat, requiring between 5% and 20% of the total heat load of the biofuel process to be supplied by the geothermal plant, it is feasible for an operator to initially implement the technology at small scale (i.e. less than 100gal/day) with the plans of scaling up operations in the future. Implementing the technology incrementally may minimize initial the investment and financial risk for the operator. Finally, in the Phase I project, we built and tested a hydrothermal system developed at ARI. We tested three different feedstock types, pure algae feed, algae mixed with manure, and algae with in-situ catalysts (molybdenum trioxide), over a range of temperatures and residence times. In terms of oil products, our results (yield, process times and elemental balance) were similar to what was obtained at PNNL. As such our experiments matched well with the techno-economic design (mass throughput specifications), and will thus well inform the Phase II process design. The experimental data obtained on the hydrothermal treatment of algae indicated that the highest recovery of oil occurred at 250°C. This shows that HTL can be carried out 100°C lower than what is currently considered ‘state of the art’, and thus save significant energy savings. Further, it was found that oil-recovered fractions had lower amounts of nitrogen at lower temperatures, indicating that oil produced at 250°C is of higher quality than if we were to produce fuel at 350°C.

09 BIOMASS FUELS↗

Examination of shipping package 9975-02403

SRNL examined shipping package 9975-02403 following storage of nuclear material in K-Area Complex (KAC). As a result of field surveillance activities in KAC, this package was identified to contain several non-conforming and other conditions. Further examination of this package in SRNL confirmed significant moisture and mold in the bottom layers of the lower fiberboard assembly, and identified additional corrosion along the seam weld and on the bottom of the drum. It was recently recommended that checking for corrosion along the bottom edge of the drum be implemented for packages that are removed from storage, as well as high wattage packages remaining in storage. The appearance of such corrosion on 9975-02403 further indicates that such corrosion may provide an indication of significant moisture concentration and related degradation within the package. This condition is more likely to develop in packages with higher internal heat loads.

99 GENERAL AND MISCELLANEOUS↗

Destructive examination of shipping package 9975-02101

Destructive and non-destructive examinations have been performed on the components of shipping package 9975-02101 as part of the comprehensive Model 9975 package surveillance program. This package is one of ten high-wattage packages that were selected for field surveillance in FY15, and was identified to contain several non-conforming conditions. Most of these conditions (mold, stains, drum corrosion, calculated fiberboard dimensions and fiberboard damage) relate to the accumulation of water in the outer and lower portions of the cane fiberboard assembly. In the short term, this causes local but reversible changes in the fiberboard properties. Long-term effects can include the permanent loss of fiberboard properties (thus far observed only in the bottom fiberboard layers) and reduced drum integrity due to corrosion. The observed conditions must be fully evaluated by KAC to ensure the safety function of the package is being maintained. Three of the other nine FY15 high-wattage packages examined in the K-Area Complex showed similar behavior. Corrosion of the overpack drum has been seen primarily in those packages with relatively severe fiberboard degradation. Visual examination of the drums in storage for external corrosion should be considered as a screening tool to identify additional packages with potential fiberboard degradation. Where overpack drum corrosion has been observed, it is typically heaviest adjacent to the stitch welds along the bottom edge. It is possible that changes to the stitch weld design would reduce the degree of corrosion in this area, but would not eliminate it. Several factors can contribute to the concentration of moisture in the fiberboard, including higher than average initial moisture content, higher internal temperature (due to internal heat load and placement with the array of packages), and the creation of additional moisture as the fiberboard begins to degrade.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗