Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Equatorial heating and hemispheric decoupling effects on inner magnetospheric core plasma evolution

We have extended our previous semikinetic study of early stage plasmasphere refilling with perpendicular ion heating by removing the restriction that the northern and southern boundaries are identical and incorporating a generalized transport description for the electrons. This allows investigation of the effects of electron heating and a more realistic calculation of electric fields produced by ion and electron temperature anisotropies. The combination of perpendicular ion heating and parallel electron heating leads to an equatorial electrostatic potential peak, which tends to shield and decouple ion flows in the northern and southern hemispheres. Unequal ionospheric upflows in the northern and southern hemispheres lead to the development of distinctly asymmetric densities and other bulk parameters. At t = 5 hour after the initiation of refiling with different source densities (N(sub north) = 100 cu/cm, N(sub south) = 50 cu/cm), the maximum potential drops of the northern and southern hemispheres are 0.6 and 1.3 V, respectively. At this time the minimum ion densities are 11 and 7 cu/cm for the northern and southern hemispheres. DE 1 observations of asymmetric density profiles by Olsen may be consistent with these predictions. Termination of particle heating causes the reduction of equatorial potential and allows interhemispheric coupling. When the inflows from the ionospheres are reduced (as may occur after sunset), decreases in plasma density near the ionospheric regions are observed while the heated trapped ion population at the equator persists.

Lin, J.↗

Heat flux modeling using ion drift effects in DIII-D H-mode plasmas with resonant magnetic perturbations

The heat flux patterns measured in low-collisionality DIII-D H-mode plasmas strongly deviate from simultaneously measured CII emission patterns, used as indicator of particle flux, during applied resonant magnetic perturbations. While the CII emission clearly shows typical striations, which are similar to magnetic footprint patterns obtained from vacuum field line tracing, the heat flux is usually dominated by one large peak at the strike point position. The vacuum approximation, which only considers applied magnetic fields and neglects plasma response and plasma effects, cannot explain the shape of the observed heat flux pattern. One possible explanation is the effect of particle drifts. This is included in the field line equations and the results are discussed with reference to the measurement. Electrons and ions show different drift motions at thermal energy levels in a guiding center approximation. While electrons hardly deviate from the field lines, ions can drift several centimetres away from field line flux surfaces. A model is presented in which an ion heat flux, based on the ion drift motion from various kinetic energies as they contribute to a thermal Maxwellian distribution, is calculated. The simulated heat flux is directly compared to measurements with a varying edge safety factor q{sub 95}. This analysis provides evidence for the dominate effect of high-energy ions in carrying heat from the plasma inside the separatrix to the target. High-energy ions are deposited close to the unperturbed strike line, while low-energy ions can travel into the striated magnetic topology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of the chemical heat treatment in a semianthracite char on the textural properties and the gasification in air

The effects of the chemical heat treatments of a semianthracite char (AC) on the textural properties and the gasification in air are investigated. Sample AC first was treated with the LiCl/KCl mixture or the mixture formed by LiCl/IKCl and a metallic oxide, M{sub n=1,2}O (MgO, CaO, FeO, CoO, NiO, Cu{sub 2}O or ZnO) at 743, 873 or 1173 K and products obtained they were then washed carefully with water distilled. The information on the textural modifications was deduced of isotherms of CO{sub 2} adsorption to 273 K. The reactivity tests were taken to the temperature 808, 823 and 838 K. As resulting from the AC treatments, on developed the microporosity and on increase the air reactivity, in particular, the first effect is greater when the used mixture went LiCl/KCl/CoO at 1173 K and the second effect are greater when the used mixture went LiCl/KCl/Cu{sub 2}O at 1173 K.

01 COAL, LIGNITE, AND PEAT↗

U-10ZR XRD Follow-on Report: Effects of Background; Extrusion, Heat Treatment

This report is a follow-on report to the previous report, INL/EXT-17-43392 “Modified Peak Ratio Method for Quantitative Texture Analysis of U10Zr Alloys” (Leah Squires, Kevin Tolman, Fidelma DiLemma, Thomas Hartman, and Douglas Porter, [June 2017]) The objective of this work is to investigate the effects of epoxy metallurgical (met) mounts on x-ray diffraction (XRD) and determine a method to account for background separate from the epoxy met mount contribution. Also, both the texturing effects of hot extrusion and cooling in ambient air (i.e., air quenching) on depleted uranium (DU)10Zr rods and the effects of heat treatments on these as-extruded DU10Zr rods are reported to determine the characteristics of texturing of the as-extruded materials and the degree of texture lost through heat treatment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Active control of asymmetric vortical flows around cones using injection and heating

The effectiveness of certain active-control methods for asymmetric flows around circular cones is investigated by using computational solution of the unsteady, compressible full Navier-Stokes equations. Two main methods of active control which include flow injection and surface heating are used. For the flow-injection-control method, flow injection is used either in the normal direction to the surface or in the tangential direction to the surface. For the surface-heating-control method, the temperature of the cone surface is increased. The effectiveness of a hybrid method of flow control which combines normal injection with surface heating has also been studied. The Navier-Stokes equations, subjected to various surface boundary conditions, are solved by using an implicit, upwind, flux-difference splitting, finite-volume scheme for locally-conical flow solutions.

Kandil, Osama A.↗

External Cooling Coupled to Reduced Extremity Pressure Device

Although suited astronauts are currently cooled with a Liquid Cooled Ventilation Garment (LCVG), which can remove up to 85 percent of body heat, their effectiveness is limited because cooling must penetrate layers of skin, muscle, fat, bone, and tissue to reach the bloodstream, where its effect is prominent. Vasoconstriction further reduces the effectiveness by limiting arterial flow when exposed to cold (the frostbite response), resulting in a time constant on the order of 20 minutes from application to maximum effect. This delay can be crucial in severe exposure to hypo- or hyper-thermic conditions, compromising homeostasis. The purpose of this innovation is to provide a lightweight, effective means of delivering heat or cold from an external source directly to the bloodstream. The effectiveness of this ECCREP (External Cooling Coupled to Reduced Extremity Pressure) device is based on not having to penetrate layers of skin, muscle, fat, and tissue, thereby avoiding the thermal lag associated with their mass and heat capacity. This is accomplished by means of an outer boot operating at a slightly reduced pressure than the rest of the body, combined with an inner boot cooled or heated by an external source via water or chemicals. Heat transfer from the external source to the foot takes place by means of circulating water or flexible heat pipes.

Kuznetz, Lawrence H.↗

Limited Role of Absolute Humidity in Intraurban Heat Variability

Abstract Monitoring and understanding the variability of heat within cities is important for urban planning and public health, and the number of studies measuring intraurban temperature variability is growing. Recognizing that the physiological effects of heat depend on humidity as well as temperature, measurement campaigns have included measurements of relative humidity alongside temperature. However, the role the spatial structure in humidity, independent from temperature, plays in intraurban heat variability is unknown. Here we use summer temperature and humidity from networks of stationary sensors in multiple cities in the United States to show spatial variations in the absolute humidity within these cities are weak. This variability in absolute humidity plays an insignificant role in the spatial variability of the heat index and humidity index (humidex), and the spatial variability of the heat metrics is dominated by temperature variability. Thus, results from previous studies that considered only intraurban variability in temperature will carry over to intraurban heat variability. Also, this suggests increases in humidity from green infrastructure interventions designed to reduce temperature will be minimal. In addition, a network of sensors that only measures temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location, allowing for lower-cost heat monitoring networks. Significance Statement Monitoring the variability of heat within cities is important for urban planning and public health. While the physiological effects of heat depend on temperature and humidity, it is shown that there are only weak spatial variations in the absolute humidity within nine U.S. cities, and the spatial variability of heat metrics is dominated by temperature variability. This suggests increases in humidity will be minimal resulting from green infrastructure interventions designed to reduce temperature. It also means a network of sensors that only measure temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location.

Meteorology & Atmospheric Sciences↗

Effects of injection angle orientation on concave and convex surfaces film cooling

The present study employs a transient liquid crystal thermography to measure film cooling performance over constant curvature of concave and convex surfaces. This work investigates detailed distributions of both film cooling effectiveness and heat transfer coefficient on concave and convex surfaces with one row of injection holes inclined stream-wise at 35 at four blowing ratios (0.5, 1.0, 1.5 and 2.0) on four test pieces with different hole configurations. All test models have a row of discrete holes with a stream-wise injection angle {gamma} of 35 and a pitch-to-diameter ratio (P/d) of 3. The current work examines four different injection configurations, one with simple and three with 8 forward-expanded holes. Three compound angles of 0, 45 and 90 with air ({rho}{sub c}/{rho}{sub m} = 0.98) as coolants are tested under the mainstream Reynolds number (Re{sub d}) of 2300 on concave surface, and 1700 on convex surface. Measured results of the concave surface show that both the span-wise averaged heat transfer coefficient and film cooling effectiveness increase with blowing ratios for all tested models. Higher heat transfer levels induced by large flow disturbance of compound-angle injection also lead to poorer overall film cooling performance, especially at high blowing ratio and large span-wise injection angle. Present results show that the best surface protection on the concave surface over the widest range of M can be provided by the forward-expanded holes with {beta} = 0 (Model-B), followed by the forward-expanded holes with {beta} = 45 (Model-C). Convex surface results show that the compound-angle injection indicates increases in both film cooling effectiveness and heat transfer at moderate and high blowing ratios. The forward-expanded hole with simple-angle injection provides the best film performance because of high film cooling effectiveness and low heat transfer coefficient at blowing ratio of 0.5. (author)

42 ENGINEERING↗

Effect of mechanical surface and heat treatments on erosion resistance

The effect of erosion by glass beads and crushed glass and by heat treatments on the erosional resistance of 6061 aluminum alloy and 1045 steel were studied. The aluminum alloy's erosion resistance was found to be insensitive to mechanical surface treatment applied before testing, and was determined to depend on the properties of the work-hardened surface layer; this was also demonstrated for aluminum alloy single crystals. The aluminum alloy heat treatments included annealing, solution, and precipitation. Solution was found to increase erosion resistance but precipitation had the opposite effect. Hardness showed no correlation with erosion resistance for either aluminum alloy steel. The steel tests showed that crushed glass provides an order of magnitude more erosion than glass beads.

Salik, J.↗

The physiological effects of simultaneous exposures to heat and vibration

Determination of the effects of exposure to vibration on the body's ability to handle heat stress, and, if so, identification of the specific vibration parameters (frequency and intensity) for both whole-body (wbv) and segmental-body vibration (sbv) that would have the most detrimental effect on the body's ability to maintain thermal homeostasis were studied. Rectal and skin temperatures, heart rates, localized sweat rates, arm-segment blood perfusion rates, respiration rates, oxygen uptakes, and respiratory exchange ratios were measured in six men (22 to 33 yr) during simultaneous exposures to heat and vibration - either wbv or sbv, and during a heated 50 min recovery period. The heat conditions were T (sub db) = 43.5 + or - 0.5 C (mean + or S.E.M.), and RH = 20 + or - 4%. All vibration exposures were divided into two exposure conditions - identical frequencies but at a high intensity (HI) and a low intensity (LI) level. The HI wbv exposure was for 25 min/day at 5 Hz, 0.37 g-rms; 10 Hz, 0.46 g-rms; 16 Hz, 0.72 g-rms; 30 Hz, 1.40 g-rms; 80 Hz, 3.70 g-rms. The LI wbv exposure was for 2.5 hr/day at the same frequencies but at the following accelerations: 0.14 g-rms; 0.18 g-rms; 0.28 g-rms; 0.55 g-rms; 1.44 g-rms. During the sbv the subject stood and grasped a vibrating, in the Z-axis, hand grip with both hands.

Spaul, W. A.↗

Kinetic phenomena in zero-gap semiconductors CuFeS{sub 2} and CuFeTe{sub 2}: Effect of pressure and heat treatment

Electrical resistivity {rho} and Hal coefficient R are measured as a function of the temperature (T = 1.7-310 K) and the magnetic field (up to H = 28 kOe) in zero-gap semiconductor CuFeS{sub 2} samples subjected to hydrostatic compression and under various heat-treatment conditions. At low temperatures, anomalies are observed in the kinetic effects related to the presence of ferromagnetic clusters: the magnetoresistance at T = 4.2 K and T = 20.4 K acquires a hysteretic character and thermopower {alpha} changes its sign at T < 15 K. The temperature dependence of conduction-electron concentration n in CuFeS{sub 2} has a power form in the temperature range T = 14-300 K, which is characteristic of the intrinsic conductivity in zero-gap semiconductors. In CuFeS{sub 2}, we have n(T) {proportional_to} T{sup 1.2}; in isoelectron compound Cu{sub 1.13}Fe{sub 1.22}Te{sub 2}, we have n(T) {proportional_to} T{sup 1.93}. Heat treatment is found to affect the intrinsic conductivity of CuFeS{sub 2}, as the action of hydrostatic compression (carrier concentration changes); that is, the carrier concentration changes. However, a power form of the n(T) and {rho}(T) dependences is retained.

36 MATERIALS SCIENCE↗

Study of nonlinear ohmic heating and ponderomotive force effects on the self-focusing and defocusing of Gaussian laser beams in collisional underdense plasmas

In the present paper, the propagation characteristics of a linearly polarized gaussian laser beam in a non-isothermal underdense collisional plasma is studied. By considering the effects of the ponderomotive force and ohmic heating of plasma electrons as the nonlinear mechanisms, the second order differential equation of the dimensionless beam width parameter has been obtained and solved at several initial ion temperatures. Furthermore, by using the nonlinear dielectric permittivity of the mentioned plasma medium in the paraxial approximation and its dependence on the propagation characteristics of the gaussian laser pulse, the perturbed electron density n{sub e}/n{sub 0e} is obtained and its variation in terms of the dimensionless plasma length is analyzed at different initial ion temperatures. Our results show that the dimensionless beam width parameter is strongly influenced by the initial plasma ion temperature. It is found that, for the self-focusing regime, the plasma electron density perturbation continuously oscillates between the initial density distribution and a minimum, and for the defocusing regime, the plasma electron density perturbation continuously oscillates between the initial density distribution and a maximum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Target normal sheath acceleration with a large laser focal diameter

In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θ L = 45°) and large focal spot size (w 0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. This deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deconditioning-induced exercise responses as influenced by heat acclimation

A study to determine the effect of heat acclimation and physical training in temperate conditions on changes in exercise tolerance following water-immersion deconditioning is presented. Five young men were tested on a bicycle ergometer before and after heat acclimation and after water immersion. The subjects and the experimental procedure, heat acclimation and exercise training, water immersion, and exercise tolerance are discussed. Heat acclimation resulted in the usual decreases in exercise heart rate and rectal temperature and an increase in sweat rate. Water immersion resulted in substantial diuresis despite water consumed. The results show that heat acclimation provides an effective method of preventing the adverse effects of water-immersion deconditioning on exercise tolerance.

Shvartz, E.↗

The seasonal effect of nitric oxide cooling on the thermospheric U.V. heat budget

The effects of (1) the radiative cooling of vibrationally-excited NO at 5.3 microns and (2) radiation entrapment at 63 microns on the UV heating efficiency 'epsilon' are examined. It is noted that the previously used heating efficiency definition contradicts its logical application, and that the two processes mentioned should be included as cooling phenomena in the energy equations. Comparisons are made with previous work by including O and NO radiative cooling in the calculation of epsilon, which is found to vary from 45 to 60%, depending on how the two radiative cooling mechanisms are included in the calculation. It is also found that the shape of the heating efficiency altitude profile varies with season, while the peak value is nearly invariant.

Richards, P. G.↗

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS↗

Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 1: Unpartitioned Blades

An investigation to determine the effectiveness of icing protection afforded by air-heating hollow steel unpartitioned propeller blades has been conducted In the NACA Cleveland icing research tunnel. The propeller used was a production model modified with blade shank and tip openings to permit internal passage of heated air. Blade-surface and heated-air temperatures were obtained and photographic observations of Ice formations were made with variations In icing intensity and heating rate to the blades. For the conditions of Icing to which the propeller was subjected, it was found that adequate ice protection was afforded with a heating rate of 40 1 000 Btu per hour per blade. With less than 40,000 Btu per hour per blade, ice protection failed because of significant ice accretions on the leading edge. The chordwise distribution of heat was unsatisfactory with most of the available heat dissipated well back of the leading edge on both the thrust and camber face's instead of at the leading edge where it was most needed. A low utilization of available heat for icing protection is indicated by a beat-exchanger effectiveness of approximately 47 percent.

Mulholland, Donald R.↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗