Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Microwave and gamma radiation observations of soil moisture

The unique dielectric properties of water at microwave wavelengths afford the possibility for remotely sensing the moisture content in the surface layer of the soil. The surface emissivity and reflectivity for the soils at these wavelengths are strong functions of its moisture content. The changes in emissivity can be observed by passive microwave techniques (radiometry) and the change in reflectivity can be observed by active microwave techniques (radar). The difference in the natural terrestrial gamma ray flux measured for wet and dry soil may be used to determine soil moisture. The presence of water moisture in the soil causes an effective increase in soil density, resulting in an increased attenuation of the gamma flux for wet soil and a corresponding lower flux above the ground surface.

Schmugge, T. J.↗

CONSTRAINTS ON THE GALACTIC POPULATION OF TeV PULSAR WIND NEBULAE USING FERMI LARGE AREA TELESCOPE OBSERVATIONS

Pulsar wind nebulae (PWNe) have been established as the most populous class of TeV {gamma}-ray emitters. Since launch, the Fermi Large Area Telescope (LAT) has identified five high-energy (100 MeV < E < 100 GeV) {gamma}-ray sources as PWNe and detected a large number of PWN candidates, all powered by young and energetic pulsars. The wealth of multi-wavelength data available and the new results provided by Fermi-LAT give us an opportunity to find new PWNe and to explore the radiative processes taking place in known ones. The TeV {gamma}-ray unidentified (UNID) sources are the best candidates for finding new PWNe. Using 45 months of Fermi-LAT data for energies above 10 GeV, an analysis was performed near the position of 58 TeV PWNe and UNIDs within 5 Degree-Sign of the Galactic plane to establish new constraints on PWN properties and find new clues on the nature of UNIDs. Of the 58 sources, 30 were detected, and this work provides their {gamma}-ray fluxes for energies above 10 GeV. The spectral energy distributions and upper limits, in the multi-wavelength context, also provide new information on the source nature and can help distinguish between emission scenarios, i.e., between classification as a pulsar candidate or as a PWN candidate. Six new GeV PWN candidates are described in detail and compared with existing models. A population study of GeV PWN candidates as a function of the pulsar/PWN system characteristics is presented.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Observations of Nucleation in a Nondilute Multicomponent Alloy

The chemical pathways leading to gamma'(L1(sub 2)) nucleation from nondilute Ni-5.2 Al-14.2 Cr at. %, gama(fcc), at 873 K are followed with radial distribution functions and isoconcentration surface analyses of direct-space atom-probe tomographic images. Although Cr atoms initially are randomly distributed, a distribution of congruent Ni3Al short-range-order domains (SRO), [R] approx. equals 0.6 nm, results from Al diffusion during quenching. Domain site occupancy develops as their number density increases leading to Al-rich phase separation by gamma'-nucleation, [R]=0.75 nm, after SRO occurs.

Sudbrack, Chantal K.↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

STUDY OF FOUR YOUNG TeV PULSAR WIND NEBULAE WITH A SPECTRAL EVOLUTION MODEL

We study four young pulsar wind nebulae (PWNe) detected in TeV {gamma}-rays, G21.5-0.9, G54.1+0.3, Kes 75, and G0.9+0.1, using the spectral evolution model developed and applied to the Crab Nebula in our previous work. We model the evolution of the magnetic field and the particle distribution function inside a uniformly expanding PWN considering a time-dependent injection from the pulsar and radiative and adiabatic losses. Considering uncertainties in the interstellar radiation field (ISRF) and their distance, we study two cases for each PWN. Because TeV PWNe have a large TeV {gamma}-ray to X-ray flux ratio, the magnetic energy of the PWNe accounts for only a small fraction of the total energy injected (typically a few Multiplication-Sign 10{sup -3}). The {gamma}-ray emission is dominated by inverse Compton scattering off the infrared photons of the ISRF. A broken power-law distribution function for the injected particles reproduces the observed spectrum well, except for G0.9+0.1. For G0.9+0.1, we do not need a low-energy counterpart because adiabatic losses alone are enough to reproduce the radio observations. High-energy power-law indices at injection are similar (2.5-2.6), while low-energy power-law indices range from 1.0 to 1.6. The lower limit of the particle injection rate indicates that the pair multiplicity is larger than 10{sup 4}. The corresponding upper limit of the bulk Lorentz factor of the pulsar winds is close to the break energy of the broken power-law injection, except for Kes 75. The initial rotational energy and the magnetic energy of the pulsars seem anticorrelated, although the statistics are poor.

79 ASTRONOMY AND ASTROPHYSICS↗

Size and Crystallinity in Protein-Templated Inorganic Nanoparticles

Protein cages such as ferritins and virus capsids have been used as containers to synthesize a wide variety of protein-templated inorganic nanoparticles. While identification of the inorganic crystal phase has been successful in some cases, very little is known about the detailed nanoscale structure of the inorganic component. We have used pair distribution function analysis of total X-ray scattering to measure the crystalline domain size in nanoparticles of ferrihydrite, {gamma}-Fe{sub 2}O{sub 3}, Mn{sub 3}O{sub 4}, CoPt, and FePt grown inside 24-meric ferritin cages from H. sapiens and P. furiosus. The material properties of these protein-templated nanoparticles are influenced by processes at a variety of length scales: the chemistry of the material determines the precise arrangement of atoms at very short distances, while the interior volume of the protein cage constrains the maximum nanoparticle size attainable. At intermediate length scales, the size of coherent crystalline domains appears to be constrained by the arrangement of crystal nucleation sites on the interior of the cage. On the basis of these observations, some potential synthetic strategies for the control of crystalline domain size in protein-templated nanoparticles are suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Gamma-ray probes of dark matter substructure

The substructure content of dark matter halos is interesting because it can be affected by complex galaxy physics and dark matter particle physics. However, observing the small scale structure of dark matter is a challenge. The subhalo abundance (mass function, minimum mass) and morphology (density profile, subhalo shape, subsubstructure) contain information about complex astrophysics (halo formation processes) and new exotic fundamental physics (dark matter interactions). Indirect detection of dark matter annihilation radiation (DMAR) in gamma rays may be the most direct method for observing small scale structure. I outline the ways in which gamma rays may probe halo substructure. If substructure is bountiful, it may be responsible for the eventual discovery of DMAR, for instance in galaxy clusters or the diffuse gamma-ray background. Otherwise, the observation of DMAR in places without much substructure, such as the Galactic center, would lead to strict limits on the properties of small scale structure. Properties of the gamma-ray angular power spectrum will also provide information or constraints on Milky Way halo substructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Next-to-leading order QCD predictions for Z,{gamma}*+3-jet distributions at the Tevatron

Using BlackHat in conjunction with SHERPA, we have computed next-to-leading order QCD predictions for a variety of distributions in Z,{gamma}*+1, 2, 3-jet production at the Tevatron, where the Z boson or off-shell photon decays into an electron-positron pair. We find good agreement between the next-to-leading order results for jet p{sub T} distributions and measurements by CDF and D0. We also present jet-production ratios, or probabilities of finding one additional jet. As a function of vector-boson p{sub T}, the ratios have distinctive features which we describe in terms of a simple model capturing leading logarithms and phase-space and parton-distribution-function suppression.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GAMMA-RAY SPECTRAL PROPERTIES OF MATURE PULSARS: A TWO-LAYER MODEL

We use a simple two-layer outer gap model, whose accelerator consists of a primary region and a screening region, to discuss the {gamma}-ray spectrum of mature pulsars detected by Fermi. By solving the Poisson equation with an assumed simple step-function distribution for the charge density in these two regions, the distribution of the electric field and the curvature radiation process of the accelerated particles can be calculated. In our model, the properties of the phase-averaged spectrum can be completely specified by three gap parameters, i.e., the fractional gap size in the outer magnetosphere, the gap current in the primary region, and the gap size ratio between the primary region and the total gap size. We discuss how these parameters affect the spectral properties. We argue that although the radiation mechanism in the outer gap is a curvature radiation process, the observed gamma-ray spectrum can substantially deviate from the simple curvature spectrum because the overall spectrum consists of two components, i.e., a primary region and a screening region. In some pulsars, the radiation from the screening region is so strong that the photon index from 100 MeV to several GeV can be as flat as {approx}2. We show that the fitting fractional gap thickness of the canonical pulsars increases with the spin-down age. We find that the total gap current is about 50% of the Goldreich-Julian value and the thickness of the screening region is a few percent of the total gap thickness. We also find that the predicted {gamma}-ray luminosity is less dependent on the spin-down power (L{sub sd}) for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while the {gamma}-ray luminosity decreases with the spin-down power for pulsars with L{sub sd} {approx}< 10{sup 36} erg s{sup -1}. This relation may imply that the major gap closure mechanism is a photon-photon pair-creation process for pulsars with L{sub sd} {approx}> 10{sup 36} erg s{sup -1}, while it is a magnetic pair-creation process for pulsars with {sub sd} {approx}< 10{sup 36} erg s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Treatment of Nitric Acid-, U(VI)-, and Tc(VII)-Contaminated Groundwater in Intermediate-Scale Physical Models of an In Situ Biobarrier

Metal and hydrogen ion acidity and extreme nitrate concentrations at Department of Energy legacy waste sites pose challenges for successful in situ U and Tc bioimmobilization. In this study, we investigated a potential in situ biobarrier configuration designed to neutralize pH and remove nitrate and radionuclides from nitric acid-, U-, and Tc-contaminated groundwater for over 21 months. Ethanol additions to groundwater flowing through native sediment and crushed limestone effectively increased pH (from 4.7 to 6.9), promoted removal of 116 mM nitrate, increased sediment biomass, and immobilized 94% of total U. Increased groundwater pH and significant U removal was also observed in a control column that received no added ethanol. Sequential extraction and XANES analyses showed U in this sediment to be solid-associated U(VI), and EXAFS analysis results were consistent with uranyl orthophosphate (UO2)3(PO4)2·4H2O(s), which may control U solubility in this system. Ratios of respiratory ubiquinones to menaquinones and copies of dissimilatory nitrite reductase genes, nirS and nirK, were at least 1 order of magnitude greater in the ethanol-stimulated system compared to the control, indicating that ethanol addition promoted growth of a largely denitrifying microbial community. Sediment 16S rRNA gene clone libraries showed that Betaproteobacteria were dominant (89%) near the source of influent acidic groundwater, whereas members of Gamma- and Alphaproteobacteria and Bacteroidetes increased along the flow path as pH increased and nitrate concentrations decreased, indicating spatial shifts in community composition as a function of pH and nitrate concentrations. Results of this study support the utility of biobarriers for treating acidic radionuclide- and nitrate-contaminated groundwater.

09 BIOMASS FUELS↗

Valence quark contribution for the {gamma}N{yields}{delta} quadrupole transition extracted from lattice QCD

Starting with a covariant spectator quark model developed for the nucleon N and the {delta} in the physical pion mass region, we extend the predictions of the reaction {gamma}N{yields}{delta} to the lattice QCD regime. The quark model includes S and D waves in the quark-diquark wave functions. Within this framework, it is the D-wave part in the {delta} wave function that generates nonzero valence contributions for the quadrupole form factors of the transition. Those contributions are however insufficient to explain the physical data, since the pion cloud contributions dominate. To separate the two effects, we apply the model to the lattice regime in a region where the pion cloud effects are negligible and adjust the D-state parameters directly to the lattice data. This process allows us to obtain a better determination of the D-state contributions. Finally, by adding a simple parametrization of the pion cloud, we establish the connection between the experimental data and the lattice data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

22(R)-hydroxycholesterol and pioglitazone synergistically decrease cholesterol ester via the PPARγ–LXRα–ABCA1 pathway in cholesterosis of the gallbladder

Highlights: • Cholesterosis is a metabolic disease characterized by excessive lipid droplets. • Lipid droplet efflux is mediated by the ABCA1 transporter. • 22(R)-hydroxycholesterol can activate LXRα and up-regulate ABCA1. • Pioglitazone up-regulates ABCA1 in a PPARγ–LXRα–ABCA1-dependent manner. • 22(R)-hydroxycholesterol and pioglitazone synergistically decrease lipid droplets. - Abstract: Cholesterosis is a disease of cholesterol metabolism characterized by the presence of excessive lipid droplets in the cytoplasm. These lipid droplets are mainly composed of cholesterol esters derived from free cholesterol. The removal of excess cholesterol from gallbladder epithelial cells (GBECs) is very important for the maintenance of intracellular cholesterol homeostasis and the preservation of gallbladder function. Several lines of evidence have indicated that the activation of either peroxisome proliferator-activated receptor gamma (PPARγ) or liver X receptor α (LXRα) relates to cholesterol efflux. While pioglitazone can regulate the activation of PPARγ, 22(R)-hydroxycholesterol can activate LXRα and is a metabolic intermediate in the biosynthesis of steroid hormones. However, the effect of 22(R)-hydroxycholesterol in combination with pioglitazone on cholesterosis of the gallbladder is unclear. GBECs were treated with pioglitazone, 22(R)-hydroxycholesterol or PPARγ siRNA followed by Western blot analysis for ATP-binding cassette transporter A1 (ABCA1), PPARγ and LXRα. Cholesterol efflux to apoA-I was determined, and Oil Red O staining was performed to monitor variations in lipid levels in treated GBECs. Our data showed that 22(R)-hydroxycholesterol can modestly up-regulate LXRα while simultaneously increasing ABCA1 by 56%. The combination of 22(R)-hydroxycholesterol and pioglitazone resulted in a 3.64-fold increase in ABCA1 expression and a high rate of cholesterol efflux. Oil Red O staining showed an obvious reduction in the lipid droplets associated with cholesterosis in GBECs. In conclusion, the present findings indicate that the anti-lipid deposition action of 22(R)-hydroxycholesterol combined with pioglitazone involves the activation of the PPARγ–LXRα–ABCA1 pathway, increased ABCA1 expression and the efflux of cholesterol from GBECs. Thus, 22(R)-hydroxycholesterol synergistically combined with pioglitazone to produce a remarkable effect on lipid deposition in cholesterosis GBECs.

60 APPLIED LIFE SCIENCES↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗