Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINGERPRINTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

The Determination of the Reaction Rates, Water Vapor Permeability, and Activation Energy for Thermal Oxidation of LDPE Films

To understand the mechanism of degradation of plastics under environmental degradation, thermal oxidation of LDPE thin film from a single manufacturer was studied. Oxidation was carried out in a pressure vessel with control at four temperatures( 22,50,70 and 80°C and at 30 and 50psi oxygen pressures. Cup tests were done to determine the permeability of water vapor across the LDPE film at 60, 70, and 90°C. The extent of oxidation was monitored using ATR-FTIR and the carbonyl content calculated from the spectra. Bands centered at 1711 and 1735 cm-1 was determined resulted from the carbonyl stretches. A broad band at 3100-3600cm -1 is attributed to O-H stretching and the fingerprint region (<1400 cm -1 ) shows evidence of C-O stretches. The permeability and carbonyl content to water vapor increased with temperature, oxidation time, and oxygen pressure. We concluded the observed increase to the result of the disruption of the semi-crystalline structure of the film to produce amorphous regions within which the water vapor is more permeable. This study was a step in the direction for determining a reliable model for the degradation and eventual failure of medium-level power cables in nuclear power plants (NPPs).

Munir, Nouman↗

Curable polysiloxane compositions and slippery materials and coatings and articles made therefrom

The present teachings generally provide curable polysiloxane compositions including a base resin including a surface active polymer. Articles of manufacture including the curable polysiloxane compositions and slippery coatings and materials also are provided. The compositions may be used to provide slippery, lubricious, or repellent materials and coatings and may provide anti-fouling function. The compositions can provide anti-fouling or foul-release function on open surfaces, internal surfaces, membranes; to provide pinning free or low contact angle hysteresis surfaces; to provide homogeneous interface to suppress nucleation; to provide a barrier layer such as anti-corrosion; to provide anti-stain, anti-smudge, anti-fingerprint, anti-soil function.

Kim, Philseok↗

System and method of mapping topology

A system for determining a fingerprint of a structure is provided. The system includes a plurality of granules inserted in a structure having a plurality of fissures, fractures, and cracks (collectively apertures), each granule comprising a membrane, and at least one bubble of compressed gas formed in the membrane, the membrane selectively dissolving in presence of a predetermined fluid and thereby selectively bursting the at least one bubble, thereby generating a concussing vibration, at least at least i) three detection devices for two-dimensional mapping or ii) four detection devices for three-dimensional mapping placed proximate to the structure according to a predetermined placement schedule, and a computing device comprising a processor configured to receive data from the at least three or four detection devices and to determine location of the at least one bubble of each of the plurality of the granules at the time of bursting by triangulating the concussive vibration in order to determine location of the at least one bubble.

Pyrak-Nolte, Laura↗

Probing Majorana wavefunctions in Kitaev honeycomb spin liquids with second-order two-dimensional spectroscopy

Two-dimensional coherent terahertz spectroscopy (2DCS) emerges as a valuable tool to probe the nature, couplings, and lifetimes of excitations in quantum materials. It thus promises to identify unique signatures of spin liquid states in quantum magnets by directly probing properties of their exotic fractionalized excitations. Here, we calculate the second-order 2DCS of the Kitaev honeycomb model and demonstrate that distinct spin liquid fingerprints appear already in this lowest-order nonlinear response $\chi^{(2)}_{yzx}(\omega_1, \omega_2)$ when using crossed light polarizations. We further relate the off-diagonal 2DCS peaks to the localized nature of the matter Majorana excitations trapped by $\mathbb{Z}_2$ flux excitations and show that 2DCS thus directly probes the inverse participation ratio of Majorana wavefunctions. By providing experimentally observable features of spin liquid states in the 2D spectrum, our work can guide future 2DCS experiments on Kitaev magnets.

Qiang, Yihua↗

Curable polysiloxane compositions and slippery materials and coatings and articles made therefrom

The present teachings generally provide curable polysiloxane compositions including a base resin including a surface active polymer. Articles of manufacture including the curable polysiloxane compositions and slippery coatings and materials also are provided. The compositions may be used to provide slippery, lubricious, or repellent materials and coatings and may provide anti-fouling function. The compositions can provide anti-fouling or foul-release function on open surfaces, internal surfaces, membranes; to provide pinning free or low contact angle hysteresis surfaces; to provide homogeneous interface to suppress nucleation; to provide a barrier layer such as anti-corrosion; to provide anti-stain, anti-smudge, anti-fingerprint, anti-soil function.

Kim, Philseok↗

Language-Theoretic Data Analysis to Support ICS Protocol Baselining

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications. Baseline behaviors may vary based on operational context. Expected operations during a maintenance window, for example, may be different from normal operations. Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming. ICS processes generate artifacts expressed across heterogeneous data sources such as network traffic and device logs. This paper explores the hypothesis that such ICS artifacts form a language in the language-theoretic sense. From a theoretical perspective, the variety of implementations of ICS protocols and constrained environment of OT networks provide a rich application domain for language-theoretic approaches. We present several use cases related to the practical construction of system baselines: grammars for data fusion, language dialects for device fingerprinting, and security automata for system baselining

24 POWER TRANSMISSION AND DISTRIBUTION↗

Polycyclic aromatic hydrocarbon emission profiles and removal efficiency by electrostatic precipitator and wetfine scrubber in an iron ore sintering plant

A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and the performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP outlet flue gases is 9.73 {mu}g/N m{sup 3}, and in ESP dust is 0.53 {mu}g/g. Regarding the emission profiles, the most abundant compound is benzo(b)fluoranthene, which has a relative low BaP toxic equivalency factors (TEF) value, followed by dibenzo(a,l)pyrene, which has a very high BaP(TEF) value. The emission profiles in ESP dust and in the flue gases after the ESP show some changes, whereas the fingerprint in ESP and stack flue gases is very similar. The removal efficiency of the ESP and of WS on the total PAH concentration is 5.2 and 59.5%, respectively. 2 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

The ethanol extract of Scutellaria baicalensis and the active compounds induce cell cycle arrest and apoptosis including upregulation of p53 and Bax in human lung cancer cells

Despite a lack of scientific authentication, Scutellaria baicalensis is clinically used in Chinese medicine as a traditional adjuvant to chemotherapy of lung cancer. In this study, cytotoxicity assays demonstrated that crude ethanolic extracts of S. baicalensis were selectively toxic to human lung cancer cell lines A549, SK-LU-1 and SK-MES-1 compared with normal human lung fibroblasts. The active compounds baicalin, baicalein and wogonin did not exhibit such selectivity. Following exposure to the crude extracts, cellular protein expression in the cancer cell lines was assessed using 2D gel electrophoresis coupled with MALDI-TOF-MS/Protein Fingerprinting. The altered protein expression indicated that cell growth arrest and apoptosis were potential mechanisms of cytotoxicity. These observations were supported by PI staining cell cycle analysis using flow cytometry and Annexin-V apoptotic analysis by fluorescence microscopy of cancer cells treated with the crude extract and pure active compounds. Moreover, specific immunoblotting identification showed the decreased expression of cyclin A results in the S phase arrest of A549 whereas the G{sub 0}/G{sub 1} phase arrest in SK-MES-1 cells results from the decreased expression of cyclin D1. Following treatment, increased expression in the cancer cells of key proteins related to the enhancement of apoptosis was observed for p53 and Bax. These results provide further insight into the molecular mechanisms underlying the clinical use of this herb as an adjuvant to lung cancer therapy. - Research Highlights: > Scutellaria baicalensis is a clinical adjuvant to lung cancer chemotherapy in China. > Scutellaria ethanol extracts selectively toxic to A549, SK-LU-1 and SK-MES-1. > Baicalin, baicalein and wogonin were toxic to all lung cancer cell lines. > Proteomics identified increased p53 and BAX in response to Scutellaria extracts.

60 APPLIED LIFE SCIENCES↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

VLLW/Exempt Waste Assay at AWE Using Cronos - 12001

Previous studies have indicated that waste bag photon monitors, such as the CANBERRA Cronos-11, have the potential to assay photon emitting uranium (U) and plutonium (Pu) contaminated wastes at the new UK VLLW/exempt waste thresholds of 1 Bq/g U and 0.15 Bq/g Pu. However, the technique has limitations associated with the operation of its plastic scintillation photon detectors. These include the absence of isotopic information and a variable detector background that is modified by the chemical and physical composition of the waste as well as the presence of any naturally occurring radioactive material (NORM). Hence, it is vital to operate Cronos in a low/non-fluctuating background environment and segregate wastes according to isotopic fingerprint, NORM concentration and waste composition. This paper presents results from subsequent Cronos measurements on a range of uncontaminated waste materials, contaminated wastes from Pu and U facilities and a National Physical Laboratory (NPL) waste package standard. The results were consistent with other assay techniques and show that Cronos can be used for exempt waste assay provided that it is operated in a low/non-fluctuating background area and the waste is well segregated before monitoring. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Container inspection in the port container terminal by using 14 MeV neutrons

A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

42 ENGINEERING↗

On-line measurements of RuO{sub 4} during a PWR severe accident

After the Fukushima accident, it became essential to have a way to monitor in real time the evolution of a nuclear reactor during a severe accident, in order to react efficiently and minimize the industrial, ecological and health consequences of the accident. Among gaseous fission products, the tetroxide of ruthenium RuO{sub 4} is of prime importance since it has a significant radiological impact. Ruthenium is a low volatile fission product but in case of the rupture of the vessel lower head by the molten corium, the air entering into the vessel oxidizes Ru into gaseous RuO{sub 4}, which is not trapped by the Filtered Containment Venting Systems. To monitor the presence of RuO{sub 4} allows making a diagnosis of the core degradation and quantifying the release into the atmosphere. To determine the presence of RuO{sub 4}, FTIR spectrometry was selected. To study the feasibility of the monitoring, high-resolution IR measurements were realized at the French synchrotron facility SOLEIL on the infrared beam line AILES. Thereafter, theoretical calculations were done to simulate the FTIR spectrum to describe the specific IR fingerprint of the molecule for each isotope and based on its partial pressure in the air. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Tolerance Studies of Commercial Strippable Coatings and Fixatives used for Decontamination - 18642

A number of commercially available products, designed for use as strippable coating and fixatives for decontamination purposes, were tested to determine their tolerability to high radiation fields and how they potentially degrade. Each product was cured and exposed to γ-radiation from a Co-60 source, up to a total dose of 500 kGy. Obvious physical colour changes and deformities were detected by visual inspection, and images captured by scanning electron microscope (SEM) showed major differences post-irradiation in some coatings. Other physical changes to the coatings were measured using Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDS); both pre- and post-irradiation. FT-IR suggested that some chemical changes were taking place in the coatings, in particular the C-H bonds and the fingerprint region appeared to be drastically altered in some coatings. EDS data indicated an increase in surface oxygen content as a result of irradiation in the majority of the samples. Additionally, coating samples were subjected to analysis by gas chromatography mass spectrometry (GCMS) in order to determine the evolved gases. The GC-MS results show that short chain hydrocarbons are produced to some degree in all the coatings during irradiation. Finally, three of the best performing coatings were selected and were irradiated using an ion beam, mimicking Pu alpha particles (with energy of around 5.25 MeV). Using the Dalton Cumbrian Facility's 5 MV tandem accelerator, coating samples were irradiated by ∼5.25 MeV He{sup 2+} particles to total dose of approximately 500 kGy. Samples were analysed using SEM, FT-IR, Raman and EDS, as was done for the gamma irradiated samples, allowing a comparison to be made between α-particle and γ-ray damage. Results from the alpha and gamma irradiations showed many similarities for the comparable assessments. A number of spectral changes observed in the FT-IR analysis were consistent across both γ-ray and α-particle irradiated samples. While there were some differences, these may be attributed to the conditions under which the irradiations were carried out. The observed similarities may allow for the inference of alpha degradation by Co-60 gamma irradiation as a more easily accessible method for determining the extent of radiolytic damage. Furthermore, gamma irradiation allows for additional analysis that is currently otherwise not possible to achieve with ion-beam exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion testing needs and considerations for additively manufactured materials in nuclear reactors

Metal additive manufacturing holds significant promise as an enabling technology for the 21st century nuclear energy industry. Metal additive manufacturing (MAM) can allow the fabrication of novel materials and innovative component designs that are not achievable through conventional manufacturing. Due to its very different fabrication methods, as-fabricated MAM components are characteristically different from conventionally manufactured components. MAM materials exhibit very different microstructures from conventional cast or wrought materials. For example, austenitic stainless steels fabricated by laser powder bed fusion exhibit columnar grain structures, dislocation cell structures, and melt pool fingerprints. In addition, MAM fabrication may result in defects such as porosity, incomplete processing of the feedstock (e.g., lack of fusion in melt-based methods), and oxide inclusions. Heat treatments may further evolve the microstructure, microsegregation, and stresses within the component. Furthermore, MAM components have a rough surface with feature sizes on the order of the feedstock material, as opposed to smooth surfaces resulting from conventional machining and forming operations. As a result, the corrosion behavior of MAM components will likely be significantly different from that of conventionally formed components. Corrosive environments for structural materials within advanced reactor environments include molten fluoride and chloride salts, liquid sodium and lead-bismuth, and high-temperature helium. The Advanced Materials and Manufacturing Technologies program within the Department of Nuclear Energy in the United States Department of Energy is assessing the unique concerns of MAM component corrosion and testing methodologies in advanced nuclear reactor environments. We discuss these concerns and testing strategies in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pixel-Registered Multimodal Synchrotron XRF and FTIR Microscopies Reveal Salinity Stress Response Mechanisms in Pistachio

Background: Salinity is a major abiotic stress that negatively affects nearly all plant species at all stages of growth. Drought and poor-quality irrigation cause high soil salinity and salt accumulation via evaporation, reducing crop productivity. Despite its critical importance, the spatial localization of salt ions and associated biochemical changes within plants experiencing high salinity remains largely unknown. In this study, we developed a multimodal imaging pipeline to understand the impact of salinity on the pistachio rootstock UCB-1 (Pistacia atlantica x Pistacia integerrima). We directly link biochemical fingerprints in stem tissue architecture with salt ion localization to provide insights into the strategies pistachio uses to tolerate salinity. Results: We observed that Pistacia spp. exposed to high salt conditions accumulated Ca, Si, Cl, Al and Mg as hotspots within the pith, compared to the control (of which only Ca and Al co-locate). In contrast, there was a decrease in K between the control and salinity treatment. Hotspots of amide I and II were present in the cortex and pith of the salinity treated sample. Additionally, the salinity treatment resulted in an increased abundance of pectin and carbohydrates within the pith compared to the control, and the abundance of esters/carboxylic acid was greater in the salinity treatment. Conclusions: We determined that Cl and K, S and P, and biochemical components polysaccharide and pectin, esters and carboxylic acid, amide I and cellulose are the strongest drivers of salinity- treatment induced variability. In the cortex and phloem/xylem, a negative K-Ca correlation decreases in the salinity treatment. Several hotspots of elements and amide I (proteins) appear under salinity treatment, particularly in the cortex, suggesting an increase in the production of stress-related proteins (in response to high Cl) and/or structural proteins (i.e. Ca). Together, these results indicate that pistachio responds to salinity through ion compartmentalization coupled with a targeted biochemical adjustment, rather than a broadscale tissue-wide response. Overall, these novel, spatially resolved pixel-registered multimodal imaging data provide an enabling platform to understand the mechanisms of salinity tolerance in Pistacia spp and can be broadly applied to studying stress-related phenotype response in various plant tissues.

FTIR spectromicroscopy↗

Ni(II) And Co(II) Sensing By Escherichia Coli RcnR

Escherichia coli RcnR and Mycobacterium tuberculosis CsoR are the founding members of a recently identified, large family of bacterial metal-responsive DNA-binding proteins. RcnR controls the expression of the metal efflux protein RcnA only in response to Ni(II) and Co(II) ions. Here, the interaction of Ni(II) and Co(II) with wild-type and mutant RcnR proteins is examined to understand how these metals function as allosteric effectors. Both metals bind to RcnR with nanomolar affinity and stabilize the protein to denaturation. X-ray absorption and electron paramagnetic resonance spectroscopies reveal six-coordinate high-spin sites for each metal that contains a thiolate ligand. Experimental data support a tripartite N-terminal coordination motif (NH{sub 2}-Xaa-NH-His) that is common for both metals. However, the Ni(II)- and Co(II)-RcnR complexes are shown to differ in the remaining coordination environment. Each metal coordinates a conserved Cys ligand but with distinct M-S distances. Co(II)-thiolate coordination has not been observed previously in Ni(II)-/Co(II)-responsive metalloregulators. The ability of RcnR to recruit ligands from the N-terminal region of the protein distinguishes it from CsoR, which uses a lower coordination geometry to bind Cu(I). These studies facilitate comparisons between Ni(II)-RcnR and NikR, the other Ni(II)-responsive transcriptional regulator in E. coli, to provide a better understanding how different nickel levels are sensed in E. coli. The characterization of the Ni(II)- and Co(II)-binding sites in RcnR, in combination with bioinformatics analysis of all RcnR/CsoR family members, identified a four amino acid fingerprint that likely defines ligand-binding specificity, leading to an emerging picture of the similarities and differences between different classes of RcnR/CsoR proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Protein detection system

The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.

47 OTHER INSTRUMENTATION↗