Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers

This protocol describes key steps in performing and analyzing femtosecond pump-probe experiments that combine a femtosecond optical laser with a free-electron laser. This includes methods to establish the spatial and temporal overlap between the optical and free-electron laser pulses during the experiment, as well as important aspects of the data analysis, such as corrections for arrival time jitter, which are necessary to obtain high-quality pump-probe data sets with the best possible temporal resolution. These methods are demonstrated for an exemplary experiment performed at the FLASH (Free-electron LASer Hamburg) free-electron laser in order to study ultrafast photochemistry in gas-phase molecules by means of velocity map ion imaging. However, most of the strategies are also applicable to similar pump-probe experiments using other targets or other experimental techniques.

47 OTHER INSTRUMENTATION↗

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering

Energy storage has become more and more a limiting factor of today's sustainable energy applications, including electric vehicles and green electric grid based on volatile solar and wind sources. The pressing demand of developing high-performance electrochemical energy storage solutions, i.e., batteries, relies on both fundamental understanding and practical developments from both the academy and industry. The formidable challenge of developing successful battery technology stems from the different requirements for different energy-storage applications. Energy density, power, stability, safety, and cost parameters all have to be balanced in batteries to meet the requirements of different applications. Therefore, multiple battery technologies based on different materials and mechanisms need to be developed and optimized. Incisive tools that could directly probe the chemical reactions in various battery materials are becoming critical to advance the field beyond its conventional trial-and-error approach. Here, we present detailed protocols for soft X-ray absorption spectroscopy (sXAS), soft X-ray emission spectroscopy (sXES), and resonant inelastic X-ray scattering (RIXS) experiments, which are inherently elemental-sensitive probes of the transition-metal 3d and anion 2p states in battery compounds. We provide the details on the experimental techniques and demonstrations revealing the key chemical states in battery materials through these soft X-ray spectroscopy techniques.

25 ENERGY STORAGE↗

Integrated Computational Materials Engineering (ICME) for Third Generation Advanced High-Strength Steel Development

This paper presents an overview of a four-year project focused on development of an integrated computational materials engineering (ICME) toolset for third generation advanced high-strength steels (3GAHSS). Following a brief look at ICME as an emerging discipline within the Materials Genome Initiative, technical tasks in the ICME project will be discussed. Specific aims of the individual tasks are multi-scale, microstructure-based material model development using state-of-the-art computational and experimental techniques, forming, toolset assembly, design optimization, integration and technical cost modeling. The integrated approach is initially illustrated using a 980 grade transformation induced plasticity (TRIP) steel, subject to a two-step quenching and partitioning (Q&P) heat treatment, as an example.

Savic, Vesna↗

Spectroscopic Study of L Hypernuclei with Electron Beams at Jefferson Lab

The missing mass spectroscopy of L hypernuclei with the (e, e'K^+) reaction was started from 2000 at Jefferson Lab. In this fifteen years, various hypernuclei (A = 7 - 52) including hyperon (L, S^0) productions have been studied with newly developed experimental techniques. The (e, e'K^+) reaction spectroscopy of L hypernuclei features its capability of absolute missing mass calibration and production of new species of hypernuclei which are the isospin partners of well studied hypernuclei by (K^-, pi-) and (pi^+, K^+) reactions. In this paper, we will review how we established the (e, e'K^+) spectroscopic study of hypernuclei.

Nakamura, Satoshi↗

Fundamental electrode kinetics

Report presents the fundamentals of electrode kinetics and the methods used in evaluating the characteristic parameters of rapid-charge transfer processes at electrode-electrolyte interfaces. The concept of electrode kinetics is outlined, followed by the principles underlying the experimental techniques for the investigation of electrode kinetics.

Elder, J. P.↗

Study of in-situ degradation of thermal control surfaces

Experimental technique used in study of damage mechanism to semiconductor pigments exposed to ultraviolet radiation can be adapted for investigations of surface chemistry and may be used analytically to determine contamination.

Gilligan, J. E.↗

Nonequilibrium ionization measurements in hydrogen-helium mixtures

Time-resolved emission measurements of several atomic line and continuum radiation channels were made behind the incident shock wave of an electric arc shock tube. Test times and nonequilibrium ionization times were obtained for shock velocities up to 2.5 X 10,000 m/sec in a 0.2 H2 - 0.8 He gas mixture. The shock-heated test gas was found to be free from driver gas contamination, and the test times were adequate to achieve steady state conditions. An activation energy of 4 eV was obtained from the nonequilibrium ionization time measurements. Modifications of experimental technique to determine the effect of test gas impurity level on ionization time measurements are discussed.

Leibowitz, L. P.↗

Long range radio tracking of sea turtles and polar bear: Instrumentation and preliminary results

Instrumentation developed for studies of path behavior of the green sea turtle and migration movement of polar bear is described. Preliminary results bearing on navigation ability in these species are presented. Both species operate in difficult environments, and the problems faced in the design of electronic instrumentation for these studies are not completely specified at this time. However, the critical factors yet to be understood are primarily related to the behavior of instrumented animals. The data obtained with these experimental techniques are included, first to illustrate the technique and, second to provide initial preliminary results bearing on animal navigation.

Baldwin, H. A.↗

Flutter technology for space shuttle

The development of analytical and experimental techniques needed to predict space shuttle flutter boundaries and insure adequate flutter margins and anticipated problems associated with aeroelastic-model and full-scale testing to validate flutter clearance are considered. Results illustrating the best available tools for subsonic and supersonic flutter prediction are presented. Programs currently underway which will help overcome the difficult problems envisioned for the transonic wind-tunnel and flight flutter test program are also discussed.

Goetz, R. C.↗