Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental Test Range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Engine-Scale Combustor Rig Designed, Fabricated, and Tested for Combustion Instability Control Research

Low-emission combustor designs are prone to combustor instabilities. Because active control of these instabilities may allow future combustors to meet both stringent emissions and performance requirements, an experimental combustor rig was developed for investigating methods of actively suppressing combustion instabilities. The experimental rig has features similar to a real engine combustor and exhibits instabilities representative of those in aircraft gas turbine engines. Experimental testing in the spring of 1999 demonstrated that the rig can be tuned to closely represent an instability observed in engine tests. Future plans are to develop and demonstrate combustion instability control using this experimental combustor rig. The NASA Glenn Research Center at Lewis Field is leading the Combustion Instability Control program to investigate methods for actively suppressing combustion instabilities. Under this program, a single-nozzle, liquid-fueled research combustor rig was designed, fabricated, and tested. The rig has many of the complexities of a real engine combustor, including an actual fuel nozzle and swirler, dilution cooling, and an effusion-cooled liner. Prior to designing the experimental rig, a survey of aircraft engine combustion instability experience identified an instability observed in a prototype engine as a suitable candidate for replication. The frequency of the instability was 525 Hz, with an amplitude of approximately 1.5-psi peak-to-peak at a burner pressure of 200 psia. The single-nozzle experimental combustor rig was designed to preserve subcomponent lengths, cross sectional area distribution, flow distribution, pressure-drop distribution, temperature distribution, and other factors previously found to be determinants of burner acoustic frequencies, mode shapes, gain, and damping. Analytical models were used to predict the acoustic resonances of both the engine combustor and proposed experiment. The analysis confirmed that the test rig configuration and engine configuration had similar longitudinal acoustic characteristics, increasing the likelihood that the engine instability would be replicated in the rig. Parametric analytical studies were performed to understand the influence of geometry and condition variations and to establish a combustion test plan. Cold-flow experiments verified that the design values of area and flow distributions were obtained. Combustion test results established the existence of a longitudinal combustion instability in the 500-Hz range with a measured amplitude approximating that observed in the engine. Modifications to the rig configuration during testing also showed the potential for injector independence. The research combustor rig was developed in partnership with Pratt & Whitney of West Palm Beach, Florida, and United Technologies Research Center of East Hartford, Connecticut. Experimental testing of the combustor rig took place at United Technologies Research Center.

DeLaat, John C.↗

A SiC NMOS Linear Voltage Regulator for High-Temperature Applications

The first SiC integrated circuit linear voltage regulator is reported. The voltage regulator uses a 20-V supply and generates an output of 15 V, adjustable down to 10 V. It was designed for loads of up to 2 A over a temperature range of 25-225 degrees C. It was, however, successfully tested up to 300 degrees C. The voltage regulator demonstrated load regulations of 1.49% and 9% for a 2-A load at temperatures of 25 and 300 degrees C, respectively. However, the load regulation is less than 2% up to 300 degrees C for a 1-A load. The line regulation with a 2-A load at 25 and 300 degrees C was 17 and 296 mV/V, respectively. The regulator was fabricated in a Cree 4H-SiC 2-mu m experimental process and consists of 1000, 32/2-mu m NMOS depletion MOSFETs as the pass device, an integrated error amplifier with enhancement MOSFETs, and resistor loads, and uses external feedback and compensation networks to ensure operational integrity. It was designed to be integrated with high-voltage vertical power MOSFETs on the same SiC substrate. It also serves as a guide to future attempts for voltage regulation in any type of integrated SiC circuitry.

Valle-Mayorga, JA↗

Experimental Study of the Microstructure and Micromechanical Properties of Laser Cladded Ni-based Amorphous Composite Coatings

(Ni{sub 0.6}Fe{sub 0.4}){sub 65}B{sub 18}Si{sub 10}Nb{sub 4}C{sub 3} amorphous composite coating was successfully fabricated on AISI 1045 steel substrate by using laser cladding process with coaxial powder feeding equipment. The microstructure and phase distribution of the coating were investigated by using x-ray diffraction, scanning electron microscopy and transmission electron microscope. The mechanical properties of the coating were examined by using microhardness testing and nanoindentation. The experimental results indicated that the volume fraction of amorphous phase increased with the decrease in laser cladding heat input, leading to an improvement of mean microhardness and nanohardness. NbC particles in a size ranging between 150 and 1650 nm were found embedding in the amorphous composite coatings in all situations. The presence of the NbC particles can contribute to an improvement of 96.7 HV in hardness on the basis of experimental results, while theoretical prediction suggests an improvement of 92.5 HV by using Orowan-Ashby equation.

36 MATERIALS SCIENCE↗

Performance evaluation of a Terry GS-2 steam impulse turbine with air-water mixtures

Terry steam turbines are widely used in various industries because of their robust design. Within the nuclear power generation industry, they are used in the Reactor Core Isolation Cooling System to remove decay heat during reactor isolation events. During the Fukushima Daiichi nuclear power station disaster in Japan in 2011, the Reactor Core Isolation Cooling System and associated Terry turbine operated for over 70 hours in Unit 2; this runtime is well beyond the expected operating duration. Theories suggest the turbine was subjected to a two-phase inlet flow, which could degrade the turbine performance. In this work, an experimental test rig was constructed to test a full-scale Terry model GS-2 steam turbine under two-phase air/water flows. Steady-state efficiency and torque performance maps of the turbine were developed over a range of turbine inlet pressures (1.38–4.83 bar or 20–70 psia), air mass fractions (0.05–1.0) and rotational speeds up to 4000 RPM. Furthermore, turbine performance followed expected trends with torque varying linearly and efficiency varying quadratically with rotational speed. In addition, high-speed images of the two-phase flow entering the turbine were also analyzed to understand how changes in inlet pressure and air mass fraction affect the flow regime and homogenization. The present tests with air–water two-phase mixtures are an important step towards providing an understanding of the full-scale Terry turbine’s behavior and performance curves under two-phase conditions. The results of this work will be combined with air/water and steam/water data gathered using a small-scale Terry ZS-1 steam turbine in order to understand the scaling relationship between large and small size Terry turbines and fluid pairs. The combined data set will enable further development of analytical models over a wide range of conditions and may be used to provide technical justification for expanded use of the Terry turbines in nuclear power plant safety systems and other systems.

42 ENGINEERING↗

Waveguide transition with vacuum window for multiband dynamic nuclear polarization systems

A low loss waveguide transition section and oversized microwave vacuum window covering several frequency bands (94 GHz, 140 GHz, 188 GHz) is presented. The transition is compact and was optimized for multiband Dynamic Nuclear Polarization (DNP) systems in a full-wave simulator. The window is more broadband than commercially available windows, which are usually optimized for single band operation. It is demonstrated that high-density polyethylene with urethane adhesive can be used as a low loss microwave vacuum window in multiband DNP systems. The overall assembly performance and dimensions are found using full-wave simulations. The practical aspects of the window implementation in the waveguide are discussed. To verify the design and simulation results, the window is tested experimentally at the three frequencies of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density-driven ionization potential depression and its effects on material properties

Changes in ionization potential at high density drive changes in material transport properties and often in crystal structure and equation of state. Current models used to describe and predict these effects have not been tested in regimes much beyond ~200 GPa, because of limitations in experimental techniques. Now, however, high-energy laser facilities with flexible pulse-shaping capabilities have made it possible to reach pressures in the 1000 GPa range, while maintaining temperatures below 1 eV. We have used these new methods to ramp-compress cobalt and magnesium and have measured shifts in the k-shell emission lines to infer changes in ionization stage, and x-ray diffraction to measure changes in crystal structure. In the case of cobalt, commonly-used detailed models for effective ionization based on isolated-atom electronic structure are shown to give the wrong answer, while self-consistent density-functional-theory-based models reproduce the data well. In the case of magnesium, zero-kelvin density functional theory predictions of density-driven electron localization in lattice interstitials (so-called electride phases) at high pressure are found to be too simple to describe material evolution along a laser ramp-compression pathway. Instead, by a combination of experiment, first-principles theory and evolutionary structure-searching algorithms, we have discovered several unexpected lower-symmetry metastable structures. First principles results find that the density of localized interstitial charge in the high-pressure magnesium phases is too low to be measurable with x-ray diffraction, and the body of theory work which has predicted high pressure electride phases for many systems, based on analysis of electron localization function, needs to be re-examined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Snowmass 2021 Whitepaper: Proton Structure at the Precision Frontier

An overwhelming number of theoretical predictions for hadron colliders require parton distribution functions (PDFs), which are an important ingredient of theory infrastructure for the next generation of high-energy experiments. This whitepaper summarizes the status and future prospects for determination of high-precision PDFs applicable in a wide range of energies and experiments, in particular in precision tests of the Standard Model and in new physics searches at the high-luminosity Large Hadron Collider and Electron–Ion Collider. We discuss the envisioned advancements in experimental measurements, QCD theory, global analysis methodology, and computing that are necessary to bring unpolarized PDFs in the nucleon to the N2LO and N3LO accuracy in the QCD coupling strength. Special attention is given to the new tasks that emerge in the era of the precision PDF analysis, such as those focusing on the robust control of systematic factors both in experimental measurements and theoretical computations. Various synergies between experimental and theoretical studies of the hadron structure are explored, including opportunities for studying PDFs for nuclear and meson targets, PDFs with electroweak contributions or dependence on the transverse momentum, for incisive comparisons between phenomenological models for the PDFs and computations on discrete lattice, and for cross-fertilization with machine learning/AI approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A search for the effect of a high frequency spark on boundary-layer transition at Mach 8.5

An experimental investigation of the use of a high frequency spark to promote early boundary layer transition on a wind tunnel model was conducted at a Mach number of 8.5. Test variables included four electrode configurations, a frequency range from 10 kHz to 50 kHz, and various power inputs to the spark. The general conclusion obtained from this investigation is that over the parameter range, the high frequency spark is ineffective in inducing early transition at the test Mach number.

Anders, J. B.↗

Design and experimental results for a turbine with jet flap stator and jet flap

The overall performance and detailed stator performance of a negative hub reaction turbine design featuring a moderately low solidity jet flap stator and a jet flap rotor were determined. Testing was conducted over a range of turbine expansion ratios at design speed. At each expansion ratio, the stator jet flow and rotor jet flow ranged up to about 7 and 8 percent, respectively, of the turbine inlet flow. The performance of the jet flap stator/jet flap rotor turbine was compared with that of a turbine which used the same jet flap rotor and a conventional, high solidity plan stator. The effect on performance of increased axial spacing between the jet stator and rotor was also investigated.

Bettner, J. L.↗

Aerodynamic performance of a ceramic-coated core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a core turbine vane with a ceramic coating was investigated experimentally in a two-dimensional cascade of 10 vanes. The vane was first tested with a rough coating and then retested after the coating had been smoothed. The test fluid was atmospheric air. The cascade tests covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey results and overall performance in terms of flow angle, weight flow, and kinetic energy loss. The performance of the ceramic-coated vanes is compared with the performance of an uncoated vane having a similar profile.

Stabe, R. G.↗

The U.S.-NSF/NASA

The five-year research and development plan of the NSF/NASA Wind Energy Conversion Systems (WECS) program is outlined. The program includes mission studies to determine energy use patterns and requirements and define specific applications for wind energy systems, wind energy resource assessment and development, and development of cost-effective components and subsystems. The program is also directed towards the development of energy storage systems to make wind powered systems firm power sources where appropriate. A 100 kW experimental wind generator (Model Zero) is being designed as a flexible test bed for a variety of system components. Designs will be developed for units in the 50 to 200 kW and 500 to 3000 kW size ranges.

Source record↗

Design and performance of a fixed, nonaccelerating, guide vane cascade that operates over an inlet flow angle range of 60 deg

A unique set of wind tunnel guide vanes are designed with an inverse design code and analyzed with a panel method and an integral boundary layer code developed at the NASA Lewis Research Center. The fixed guide vanes, 80 feet long with 6-foot chord length, were designed for the NASA Ames 40 x 80/80 x 120 ft Wind Tunnel. Low subsonic flow is accepted over a 60 deg range of inlet angle from either the 40 x 80 leg or the 80 x 120 leg of the wind tunnel, and directed axially into the main leg of the tunnel where drive fans are located. Experimental tests of 1/10-scale models were conducted to verify design calculations.

Sanz, J. M.↗

Shutdown characteristics of the Mod-O wind turbine with aileron controls

Horizontal-axis wind turbines utilize partial or full variable blade pitch to regulate rotor speed. The weight and costs of these systems indicated a need for alternate methods of rotor control. Aileron control is an alternative which has potential to meet this need. The NASA Lewis Research Center has been experimentally testing aileron control rotors on the Mod-U wind turbine to determine their power regulation and shutdown characteristics. Experimental and analytical shutdown test results are presented for a 38 percent chord aileron-control rotor. These results indicated that the 38 percent chord ailerons provided overspeed protection over the entire Mod-O operational windspeed range, and had a no-load equilibrium tip speed ratio of 1.9. Thus, the 38 percent chord ailerons had much improved aerodynamic braking capability when compared with the first aileron-control rotor having 20 percent chord ailerons.

Miller, D. R.↗

Design and performance of a fixed, nonaccelerating guide vane cascade that operates over an inlet flow angle range of 60 deg

A unique set of wind tunnel guide vanes are designed with an inverse design code and analyzed with a panel method and an integral boundary layer code developed at the NASA Lewis Research Center. The fixed guide vanes, 80 feet long with 6-foot chord length, were designed for the NASA Ames 40 x 80/80 x 120 ft Wind Tunnel. Low subsonic flow is accepted over a 60 deg range of inlet angle from either the 40 x 80 leg or the 80 x 120 leg of the wind tunnel, and directed axially into the main leg of the tunnel where drive fans are located. Experimental tests of 1/10-scale models were conducted to verify design calculations.

Sanz, J. M.↗

Investigation to advance prediction techniques of the low-speed aerodynamics of V/STOL aircraft

A computer program, VSAERO, has been applied to a number of V/STOL configurations with a view to advancing prediction techniques for the low-speed aerodynamic characteristics. The program couples a low-order panel method with surface streamline calculation and integral boundary layer procedures. The panel method--which uses piecewise constant source and doublet panels-includes an iterative procedure for wake shape and models boundary layer displacement effect using the source transpiration technique. Certain improvements to a basic vortex tube jet model were installed in the code prior to evaluation. Very promising results were obtained for surface pressures near a jet issuing at 90 deg from a flat plate. A solid core model was used in the initial part of the jet with a simple entrainment model. Preliminary representation of the downstream separation zone significantly improve the correlation. The program accurately predicted the pressure distribution inside the inlet on the Grumman 698-411 design at a range of flight conditions. Furthermore, coupled viscous/potential flow calculations gave very close correlation with experimentally determined operational boundaries dictated by the onset of separation inside the inlet. Experimentally observed degradation of these operational boundaries between nacelle-alone tests and tests on the full configuration were also indicated by the calculation. Application of the program to the General Dynamics STOL fighter design were equally encouraging. Very close agreement was observed between experiment and calculation for the effects of power on pressure distribution, lift and lift curve slope.

Maskew, B.↗

High-resolution liquid-crystal heat-transfer measurements on the end wall of a turbine passage with variations in Reynolds number

Local heat-transfer coefficients were experimentally mapped on the end-wall surface of a three-times turbine vane passage in a static, single-row cascade operated with room-temperature inlet air over a range of Reynolds numbers. The test surface was a composite of commercially available materials: a Mylar sheet with a layer of cholesteric liquid crystals, which change color with temperature, and a heater made of a polyester sheet coated with vapor-deposited gold, which produces uniform heat flux. After the initial selection and calibration of the composite sheet, accurate, quantitative, and continuous heat-transfer coefficients were mapped over the end-wall surface. The local heat-transfer coefficients (expressed as nondimensional Stanton number) are presented for inlet Reynolds numbers (based on vane axial chord) from 0.83 x 10(5) to 3.97 x 10(5).

Hippensteele, Steven A.↗