Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Low carbon and clean energy scenarios for India: Analysis of targets approach

Low carbon energy technologies are gaining increasing importance in India for reducing emissions as well as diversifying its energy supply mix. The present paper presents and analyses a targeted approach for pushing solar, wind and nuclear technologies in the Indian energy market. Targets for these technologies have been constructed on the basis of Indian government documents, policy announcements and expert opinion. Different targets have been set for the reference scenario and the carbon price scenario. In the reference scenario it is found that in the long run all solar, wind and nuclear will achieve their targets without any subsidy push. In the short run however, nuclear and solar energy require significant subsidy push. Nuclear energy requires a much higher subsidy allocation as compared to solar because the targets assumed are also higher for nuclear energy. Under a carbon price scenario, the carbon price drives the penetration of these technologies significantly. Still subsidy is required especially in the short run when the carbon price is low. It is also found that pushing solar, wind and nuclear technologies might lead to decrease in share of CCS under the price scenario and biomass under both BAU and price scenario, which implies that one set of low carbon technologies is substituted by other set of low carbon technologies. Thus the objective of emission mitigation might not be achieved due to this substitution. Moreover sensitivity on nuclear energy cost was done to represent risk mitigation for this technology and it was found that higher cost can significantly decrease the share of this technology under both the BAU and carbon price scenario.

energy↗

BESSIE: Battery & Energy Storage Supply Chain Analysis, Mitigation Deployment, and Tools

Battery energy storage systems (BESS) and their associated power electronic interfaces are key components to delivering clean and more resilient energy, providing much-needed fast-ramping, emergency discharge, generation, and operations support to the electric grid. These services have grown to be invaluable over the past ten years and will soon be an irreplaceable element of energy delivery. The Idaho National Laboratory (INL) strives to address these challenges through a strategic approach to supply chain risk assessment and mitigation for BESS and related digital energy equipment through the BESSIE project under the Center for Securing Digital Energy Technology. Recognizing that decreasing dependence on a foreign supply chain will take significant time and investment, BESSIE’s focus is strategically addressing battery supply chain risks by pairing short-term steps to operate securely through today’s risks with long-term steps to shape the supply chain over the coming years.

25 ENERGY STORAGE↗

Lower-Energy Requirements for Power-Assist HEV Energy Storage Systems--Analysis and Rationale (Presentation)

Presented at the 27th International Battery Seminar and Exhibit, 15-18 March 2010, Fort Lauderdale, Florida. NREL conducted simulations and analysis of vehicle test data with research partners in response to a USABC request; results suggest that power-assist hybrid electric vehicles (HEVs), like conventional HEVs, can achieve high fuel savings with lower energy requirements at potentially lower cost.

25 ENERGY STORAGE↗

Surrogate-driven Variance-based Sensitivity Analysis of Thermal Storage Tanks in Integrated Energy Systems

Sensitivity analysis and uncertainty quantification are essential steps for enhancing the accuracy of computational models by identifying and mitigating uncertainties. This study focuses on these steps for the Thermal Energy Delivery System at Idaho National Laboratory, specifically targeting the thermocline tank. Using a Modelica/Dymola simulation model, the study perturbed various design parameters and boundary conditions, including shape factor, porosity, outlet temperature, inlet mass flow rate, and system pressure, to predict and quantify uncertainty in the tank’s ax- ial temperature. A dataset of over 1,000 simulations was generated, and surrogate models were developed using the pyMAISE (Michigan Artificial Intelligence Standard Environment) library, which is an Automatic Machine Learning library for nuclear engineering applications. The optimal model, a feedforward neural network with two hidden layers, achieved an R2 score above 0.99 and a mean absolute error below 1 Kelvin. Sensitivity analyses using Sobol indices and Fourier amplitude sensitivity testing methods on this surrogate model revealed that the inlet mass flow rate at initial timestamps and porosity significantly impacts predicted temperatures across all sensors and time steps.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy efficiency and thermal resilience analysis for row houses using representative building energy models

Row houses, a prevalent medium-density urban archetype, were popularized during industrial era to accommodate the working class in the U.S. cities. Today, many of these structures are deteriorating, exacerbating the energy cost for residents with limited economic resources. Moreover, many households that lack Air Conditioning (AC) are vulnerable to extreme summer heat, an issue expected to worsen in the future. Energy-efficient retrofits can help mitigate these challenges. However, current literature provides limited insight into how existing building energy codes impact the energy efficiency and thermal resilience of row houses in current and future weather scenarios. This study provides a detailed method to address this gap by employing calibrated representative energy models of row houses as a baseline, and evaluating the annual energy savings and summertime thermal safety improvements from code compliant retrofits under current and future typical weather conditions. Using Baltimore City as a case study, results show that under current weather, retrofitting row houses yields significant energy savings along with notable thermal resilience improvements. The end unit row house realizes higher energy savings, whereas the interior unit experiences greater thermal resilience improvement after retrofitting. In future, retrofitted row houses can still save energy, but residents will face numerous hours of fatal indoor temperatures without AC in summer. Additionally, findings reveal stark zone-wise variations in thermal safety, and elevated humidity risks in certain zones post-retrofit, emphasizing the need for zonal retrofit strategies and better natural ventilation strategies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Striped Data Analysis Framework

Traditionally, High Energy data analysis is based on the model where data are stored in files and analyzed by running multiple analysis processes, each reading one or more of the data files. This process involves repeated data reduction step, which produces smaller files, which is time consuming and leads to data duplication. We propose an alternative approach to data storage and analysis, based on the Big Data technologies. The idea is to store each element of data once and only once in a distributed scalable database and analyze data by reading only "interesting" pieces of data from the database. To make this approach possible, we developed columnar Striped Data Representation Format as the basis of the framework. Traditional columnar approach allows for efficient analysis of complex data structures. While keeping all the benefits of columnar data representation, striped mechanism goes further by enabling efficient parallelization of computations and flexible dist ribution of data analysis. The framework includes scalable and elastic data storage, compute and user analysis backend components. The framework uses off-the shelf web services and data caching technologies as the compute/data co-location mechanism. Flexible architecture allows the framework run in the cloud using container technologies. The framework offers Python/Jupyter as the user analysis backend platform, but can also run in command line or batch mode. In the article, we will present the results of the FNAL-LDRD-2016-032 FNAL LDRD project, the design, implementation, features and performance characteristics of the Striped Data Analysis Framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deciphering mixotrophic Clostridium formicoaceticum metabolism and energy conservation: Genomic analysis and experimental studies

Clostridium formicoaceticum, a Gram-negative mixotrophic homoacetogen, produces acetic acid as the sole metabolic product from various carbon sources, including fructose, glycerol, formate, and CO 2 . Its genome of 4.59-Mbp contains a highly conserved Wood-Ljungdahl pathway gene cluster with the same layout as that in other mixotrophic acetogens, including Clostridium aceticum , Clostridium carboxidivorans , and Clostridium ljungdahlii . For energy conservation, C. formicoaceticum does not have all the genes required for the synthesis of cytochrome or quinone used for generating proton gradient in H + -dependent acetogens such as Moorella thermoacetica ; instead, it has the Rnf system and a Na + -translocating ATPase similar to the one in Acetobacterium woodii. Furthermore its growth in both heterotrophic and autotrophic media were dependent on the sodium concentration. C. formicoaceticum has genes encoding acetaldehyde dehydrogenases, alcohol dehydrogenases, and aldehyde oxidoreductases, which could convert acetyl-CoA and acetate to ethanol and butyrate to butanol under excessive reducing equivalent conditions.

09 BIOMASS FUELS↗

Cumulative Effects Analysis for Wind Energy Development: Current Practices, Challenges, and Opportunities (IEA Wind White Paper)

The increasing global deployment of wind energy has given rise to concerns about potential adverse effects on certain wildlife species and habitats. The United States and European nations use environmental impact assessments (EIAs) to evaluate the environmental effects of wind energy and inform wind energy planning, siting, and operational processes. A key component of the EIA is the cumulative effects analysis/assessment (CEA). CEAs consider the effects of a proposed development in the context of past, present, and future developments, as well as other (non-wind) activities. However, practitioners worldwide have struggled to implement cost-effective and consistent processes for CEAs. Further, there is no widely accepted scientific methodology to assess cumulative effects. As wind energy deployment continues to expand, developing a consistent and scientifically based approach to CEAs may provide a more comparable across assessments and cost-effective means of reducing risk during siting, operations, and decommissioning/repowering, while minimizing regulatory hurdles. This technical report evaluates the current state of CEA practices, covering both land-based and offshore wind energy development. It focuses on impacts from the preconstruction, construction, and operational phases of the wind farm, which are the phases where most research currently exists. Emerging research addresses impacts from the perspective of life cycle assessments (LCAs), including the impacts of manufacturing and preconstruction (May et al. 2020). The technical report also summarizes CEA processes and guidelines, analysis approaches, and current challenges. Finally, it highlights opportunities for further research and coordination, and includes a geographically organized CEA information resource bank.

17 WIND ENERGY↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of 25Al energy levels observed in the 28Si(p,alpha)25Al reaction

The level structure of {sup 25}Al has been studied at the ORNL Holifield Radioactive Ion Beam Facility (HRIBF) by measuring the angular and energy distributions of alpha particles from the {sup 28}Si(p,{alpha}){sup 25}Al reaction. Proton beams ({approx}10 nA) at laboratory energies of 40- and 42-MeV were generated by the 25 MV tandem accelerator and bombarded a natural silicon target (50 {micro}g/cm{sup 2}). Alpha particles were detected and identified in the Silicon Detector Array (SIDAR) in the 'telescope' configuration [1]. Eighteen levels have been observed and spins for several have been constrained through a distorted-wave Born approximation (DWBA) analysis of the angular distributions.

43 PARTICLE ACCELERATORS↗

New technologies for solar energy silicon - Cost analysis of dichlorosilane process

A reduction in the cost of silicon for solar cells is an important objective in a project concerned with the reduction of the cost of electricity produced with solar cells. The cost goal for the silicon material is about $14 per kg (1980 dollars). The process which is currently employed to produce semiconductor grade silicon from trichlorosilane is not suited for meeting this cost goal. Other processes for producing silicon are, therefore, being investigated. A description is presented of results obtained for the DCS process which involves the production of dichlorosilane as a silicon source material for solar energy silicon. Major benefits of dichlorosilane as a silicon source material include faster reaction rates for chemical vapor deposition of silicon. The DCS process involves the reaction 2SiHCl3 yields reversibly SiH2Cl2 + SiCl4. The results of a cost analysis indicate a total product cost without profit of $1.29/kg of SiH2Cl2.

Yaws, C. L.↗

Regional Hybrid Energy Systems Technoeconomic Analysis

This presentation summarizes the final outputs from a multi-year HFTO-funded project that evaluated the potential for hybridized nuclear power plants to economically produce hydrogen. The focus of this presentation is on the interactions between the electricity system modeling and hydrogen system optimization and the resulting figures of merit. This project partnered with Idaho National Laboratory, Argonne National Laboratory, Electric Power Research Institute, and Xcel Energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDROGEN↗

ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Qualitative Analysis

This report provides a final qualitative analysis of all addenda to ANSI/ASHRAE/IES Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition). All addenda in creating Standard 90.1-2013 were evaluated for their projected impact on energy efficiency. Each addendum was characterized as having a positive, neutral, or negative impact on overall building energy efficiency.

Halverson, Mark A.↗

ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Qualitative Analysis

This report provides the qualitative analysis of all addenda to ANSI/ASHRAE/IES1 Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition). All addenda in creating Standard 90.1-2013 were evaluated for their projected impact on energy efficiency. Each addendum was characterized as having a positive, neutral, or negative impact on overall building energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of time-frequency-analysis techniques applied in building energy data noise cancellation for building load forecasting: A real-building case study

Time-frequency analysis that disaggregates a signal in both time and frequency domain is an important supporting technique for building energy analysis such as noise cancellation in data-driven building load forecasting. There is a gap in the literature related to comparing various time–frequency-analysis techniques, especially discrete wavelet transform (DWT) and empirical mode decomposition (EMD), to guide the selection and tuning of time–frequency-analysis techniques in data-driven building load forecasting. This article provides a framework to conduct a comprehensive comparison among thirteen DWT/EMD techniques with various parameters in a load forecasting modeling task. A real campus building is used as a case study for illustration. The DWT and EMD techniques are also compared under various data-driven modeling algorithms for building load forecasting. The results in the case study show that the load forecasting models trained with noise-cancelled energy data have increased their accuracy to 9.6% on average tested under unseen data. This study also shows that the effectiveness of DWT/EMD techniques depends on the data-driven algorithms used for load forecasting modeling and the training data. Hence, DWT/EMD-based noise cancellation needs customized selection and tuning to optimize their performance for data-driven building load forecasting modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010

This Technical Support Document presents the energy and cost savings analysis that PNNL conducted to measure the potential energy savings of 90.1-2010 relative to 90.1-2004. PNNL conducted this analysis with inputs from many other contributors and source of information. In particular, guidance and direction was provided by the Simulation Working Group under the auspices of the SSPC90.1. This report documents the approach and methodologies that PNNL developed to evaluate the energy saving achieved from use of ASHRAE/IES Standard 90.1-2010. Specifically, this report provides PNNL’s Progress Indicator process and methodology, EnergyPlus simulation framework, prototype model descriptions. This report covers the combined upgrades from 90.1-2004 to 90.1-2010, resulting in a total of 153 addenda. PNNL has reviewed and considered all 153 addenda for quantitative analysis in the Progress Indicator process. 53 of those are included in the quantitative analysis. This report provides information on the categorization of all of the addenda, a summary of the content, and deeper explanation of the impact and modeling of 53 identified addenda with quantitative savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enclosure fire hazard analysis using relative energy release criteria

A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.

Coulbert, C. D.↗