Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

High Operating Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength

A barrier infrared detector with absorber materials having selectable cutoff wavelengths and its method of manufacture is described. A GaInAsSb absorber layer may be grown on a GaSb substrate layer formed by mixing GaSb and InAsSb by an absorber mixing ratio. A GaAlAsSb barrier layer may then be grown on the barrier layer formed by mixing GaSb and AlSbAs by a barrier mixing ratio. The absorber mixing ratio may be selected to adjust a band gap of the absorber layer and thereby determine a cutoff wavelength for the barrier infrared detector. The absorber mixing ratio may vary along an absorber layer growth direction. Various contact layer architectures may be used. In addition, a top contact layer may be isolated into an array of elements electrically isolated as individual functional detectors that may be used in a detector array, imaging array, or focal plane array.

Ting, David Z.↗

Small Aperture Telescopes for the Simons Observatory

The Simons Observatory (SO) is an upcoming cosmic microwave background(CMB) experiment located on Cerro Toco, Chile, that will map the microwave sky in temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO will consist of one 6-meter Large Aperture Telescope (LAT) fielding∼30,000 detectors and an array of three 0.42-meter Small Aperture Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will allow for the extremely sensitive characterization of the CMB over an-gular scales ranging from an arcmin to tens of degrees, enabling a wide range of scientific output. Here we focus on the SATs targeting degree angular scales with successive dichroic instruments observing at Mid-Frequency (MF: 93/145 GHz), Ultra-High-Frequency (UHF:225/285 GHz), and Low-Frequency (LF: 27/39 GHz). The three SATs will be able to map∼10% of the sky to a noise level of∼2 μK-arcmin when combining 93 and 145 GHz. The multiple frequency bands will allow the CMB to be separated from galactic foregrounds (primarily synchrotron and dust), with the primary science goal of characterizing the primordial tensor-to-scalar ratio, r, at a target level ofσ(r)≈0.003.

Small aperature telescope↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the JWST/MIRI Si:As Detectors

The Mid-Infrared Instrument (MIRI) is a 5 to 28 micron imager and spectrometer that is slated to fly aboard the JWST in 2013. Each of the flight arrays is a 1024x1024 pixel Si:As impurity band conductor detector array, developed by Raytheon Vision Systems. JPL, in conjunction with the MIRI science team, has selected the three flight arrays along with their spares. We briefly summarize the development of these devices, then describe the measured performance of the flight arrays along with supplemental data from sister flight-like parts.

arsenic-doped silicon↗

CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

X-ray↗

Photometry with Multi-anode Microchannel Arrays (mamas) and Charge Injection Devices (cids)

The characteristics of two kinds of detectors are summarized with emphasis on those aspects that would affect their use in high accuracy astronomical photometry. The first type, the multianode microchannel arrays (MAMA), are a family of pulse counting array detectors. Components and operation principles are reviewed and quantum efficiency, noise characteristics, and dynamic range characteristics are described. The second type, charge injection devices (CID), are discussed in reference to their applicability to photometric detection at optical wavelengths.

Timothy, J. G.↗

The Detector Subsystem for the SXS Instrument on the Astro-H Observatory

The Soft X-ray Spectrometer (SXS) instrument on the Astro-H observatory is based on a 36 pixel x-ray calorimeter array cooled to 50 mK in a sophisticated spaceflight cryostat. The SXS is a true spatial-spectral instrument, where each spatially discrete pixel functions as a high-resolution spectrometer. Here we discuss the SXS detector subsystem that includes the detector array, the anticoincidence detector, the first stage amplifiers, the thermal and mechanical staging of the detector, and the cryogenic bias electronics. The design of the SXS detector subsystem has significant heritage from the Suzaku/XRS instrument but has some important modifications that increase performance margins and simplify the focal plane assembly. Notable improvements include x-ray absorbers with significantly lower heat capacity, improved load resistors, improved thermometry, and a decreased sensitivity to thermal radiation. These modifications have yielded an energy resolution of 3.5-4.0 eV FWHM at 6 keV for representative devices in the laboratory, giving considerable margin against the 7 eV instrument requirement. We expect similar performance in flight

Porter, Frederick↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

High precision computing with charge domain devices and a pseudo-spectral method therefor

The present invention enhances the bit resolution of a CCD/CID MVM processor by storing each bit of each matrix element as a separate CCD charge packet. The bits of each input vector are separately multiplied by each bit of each matrix element in massive parallelism and the resulting products are combined appropriately to synthesize the correct product. In another aspect of the invention, such arrays are employed in a pseudo-spectral method of the invention, in which partial differential equations are solved by expressing each derivative analytically as matrices, and the state function is updated at each computation cycle by multiplying it by the matrices. The matrices are treated as synaptic arrays of a neural network and the state function vector elements are treated as neurons. In a further aspect of the invention, moving target detection is performed by driving the soliton equation with a vector of detector outputs. The neural architecture consists of two synaptic arrays corresponding to the two differential terms of the soliton-equation and an adder connected to the output thereof and to the output of the detector array to drive the soliton equation.

Barhen, Jacob↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

Design and Fabrication of Two-Dimensional Superconducting Bolometer Array for SAFIRE

The Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, close-packed bolometer array. SAFIRE is an imaging Fabry-Perot spectrometer operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this instrument. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs (Noise Equivalent Powers) of order 5x10(exp 18)W/square root of Hz. An architecture which permits 512 pixels to be placed adjacent to each other in an area the size of a postage stamp, integrate them with multiplexers, and provide all the necessary wiring interconnections is a complex proposition, but can be achieved. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. The result is a compact array, easily scalable to kilopixel arrays. Engineering results from the first such detector arrays will be presented.

Benford, Dominic↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterojunction-Internal-Photoemission Infrared Detectors

New type of photodetector adds options for design of imaging devices. Heterojunction-internal-photoemission (HIP) infrared photodetectors proposed for incorporation into planar arrays in imaging devices required to function well at wavelengths from 8 to 17 micrometers and at temperatures above 65 K. Photoexcited electrons cross energy barrier at heterojunction and swept toward collection layer. Array of such detectors made by etching mesa structures. HIP layers stacked to increase quantum efficiency. Also built into integrated circuits including silicon multiplexer/readout circuits.

Maserjian, Joseph↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8 m and 12.0 m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M.↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8[mu]m and 12.0[mu]m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M↗

Compact Focal Plane Assembly for Planetary Science

A compact radiometric focal plane assembly (FPA) has been designed in which the filters are individually co-registered over compact thermopile pixels. This allows for construction of an ultralightweight and compact radiometric instrument. The FPA also incorporates micromachined baffles in order to mitigate crosstalk and low-pass filter windows in order to eliminate high-frequency radiation. Compact metal mesh bandpass filters were fabricated for the far infrared (FIR) spectral range (17 to 100 microns), a game-changing technology for future planetary FIR instruments. This fabrication approach allows the dimensions of individual metal mesh filters to be tailored with better than 10- micron precision. In contrast, conventional compact filters employed in recent missions and in near-term instruments consist of large filter sheets manually cut into much smaller pieces, which is a much less precise and much more labor-intensive, expensive, and difficult process. Filter performance was validated by integrating them with thermopile arrays. Demonstration of the FPA will require the integration of two technologies. The first technology is compact, lightweight, robust against cryogenic thermal cycling, and radiation-hard micromachined bandpass filters. They consist of a copper mesh supported on a deep reactive ion-etched silicon frame. This design architecture is advantageous when constructing a lightweight and compact instrument because (1) the frame acts like a jig and facilitates filter integration with the FPA, (2) the frame can be designed so as to maximize the FPA field of view, (3) the frame can be simultaneously used as a baffle for mitigating crosstalk, and (4) micron-scale alignment features can be patterned so as to permit high-precision filter stacking and, consequently, increase the filter bandwidth and sharpen the out-of-band rolloff. The second technology consists of leveraging, from another project, compact and lightweight Bi0.87Sb0.13/Sb arrayed thermopiles. These detectors consist of 30-layer thermopiles deposited in series upon a silicon nitride membrane. At 300 K, the thermopile arrays are highly linear over many orders of magnitude of incident IR power, and have a reported specific detectivity that exceeds the requirements imposed on future mission concepts. The bandpass filter array board is integrated with a thermopile array board by mounting both boards on a machined aluminum jig.

Brown, Ari↗