Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISPLACED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Displacement of plasma protein and conduction velocity in rats under action of acceleration forces and hypokinesia

The permeability of capillary vessels was investigated in order to determine if acceleration alone or following prolonged hypokinesia would induce changes in the vascular wall leading to the penetration by l-albumins and/or proteins with larger molecules. In rats undergoing action of +5 Gz accelerations, no increase in vascular permeability, as tested with the use of (Cr-5k)-globulin, was demostrated. In rats immobilized for 4 weeks before centrifugation, rather weak migration of (Cr-51)-globulin from the vessels was observed. Immobilization resulted also in lowering of conduction velocity in the sciatic nerve.

Baranski, S.↗

Measurements of displacement around holes in composite plates subjected to quasi-static compression

Attempts to develop a whole-field, high sensitivity optical technque for measurement of load induced changes of thickness of composite plates are described. Graphite-epoxy plates of quasi-isotropic layup were used as test specimens. Changes of thickness of three plates, each with a central hole of different size, were measured as a function of applied compressive loads. The first test specimen showed localized zones where no holographic fringes were present, surrounded by zones of low fringe contrast. This was thought to be a result of localized motion or creep. Subsequent tests with an increased time interval between specimen loading and holographic exposure demonstrated no localized zones of absent fringes. No plausible explanation for radical differences in the quality of fringe patterns was found, although the use of specimens having a high quality mirrorized surface provided superior change of thickness patterns. Recommendations for further investigations and changes in test procedure are presented.

Duke, J. C., Jr.↗

Evaluation of an electro-optic remote displacement measuring system

An instrumentation system to provide a noncontact method for measurement of target positions was evaluated. The system employs two electro-optic camera units which give stereo information for use in determining three dimensional target locations. Specially developed, infrared sensitive photodetectors are used in the cameras to sense radiation from light emitting diode targets. Up to 30 of these targets can be monitored with a sampling rate of 312 Hz per target. An important part of the system is a minicomputer which is used to collect the camera data, sort it, make corrections for distortions in the electro-optic system, and perform the necesssary coordinate transformations. If target motions are restricted to locations in a plane which is perpendicular to a camera's optical axis, the system can be used with just one camera. Calibrations performed in this mode characterize accuracies in single camera operation. This information is also useful in determination of single camera contributions to total system errors. For this reason the system was tested in both the single camera and two camera (stereo) modes of operation.

Monteith, J. H.↗

Lunar highland crustal models based on iron concentrations - Isostasy and center-of-mass displacement

Data is introduced on the iron concentrations of the lunar surface which have been refined by means of convolution corrections to restore the spatial resolution and contrast lost by the omnidirectional spectrometer. This refined iron data is synthesized with other orbital seismic, and lunar sample data to derive highland crustal density and thickness, and isostasy and lunar centers of mass models are examined in light of this new information. A model is developed by which highland crustal density is calculated for each highland region from orbital observations of Fe, Mg and Ti concentrations. The results of this model are presented numerically and graphically for 35 highland and two non-highland regions. Density and thickness results are then applied to two long-standing lunar problems: (1) the nature of highland isostasy, which is shown to be controlled by crustal thickness rather than density, and (2) the separation of the moon's mass and figure centers, which is shown to be due to the crustal thickness difference between the lunar near and far sides.

Haines, E. L.↗

Tilt from a head-inverted position produces displacement of visual subjective vertical in the opposite direction

Observers who lie supine with their heads inverted report large (up to 60 deg) tilt of a light line in an otherwise dark room when their heads and/or bodies are tilted. Most observers report that visual subjective vertical is tilted in the direction opposite to the head/body tilt. The results can be interpreted by employing a model developed by Mittelstaedt (1983), which suggests that visual subjective vertical is derived from a gravity vector transduced by vestibular and somesthetic receptors combined with 'idiotropic vectors' that represent the orientation of the observer's own head and body axes.

Parker, D. E.↗

Vertical displacement of the mid-tropospheric water vapor boundary in the tropics derived from the VISSR Atmospheric Sounder (VAS) 6.7-micron channel

A technique for locating areas of upward or downward motion of the upper boundary of the midtropospheric water-vapor envelope over tropical oceans on the basis of GOES Visible/IR Spin-Scan Radiometer (VISSR) Atmospheric Sounder (VAS) 6.7-micron brightness temperatures is developed and demonstrated. The technique employs an analogy to the method developed by Schoeberl and Krueger (1983) for the bottom of the ozone layer and depends on the relationship investigated by Chesters and Uccellini (1982) between 6.7-micron brightness temperature and the pressure of the water-vapor upper boundary. The results of analysis of VAS data for the North Atlantic (20-40 deg N and 35-75 deg W) on September 5-7, 1982, are presented in maps which are shown to be physically consistent and in agreement with conventional upper-air measurements. Refinement of the method to account for horizontal advection and diffusion is suggested.

Stout, J.↗

Explanation of the inward displacement of Io's hot plasma torus and consequences for sputtering sources

Radial profiles of the ion density and flux-tube content in the Io torus have peak values inside Io's orbit, even though Io is the effective source of these ions. Formation of an inward peak constrains either the velocity distributions or source regions of sputtered neutrals. A further constraint is that the ionization of neutrals on trapped trajectories that return to Io's surface must be limited. A dominant sulphur source is most easily reconciled with these constraints.

Linker, J. A.↗

Modeling of the surface static displacements and fault plane slip for the 1979 Imperial Valley earthquake

Three-dimensional finite element modeling techniques are used to synthesize geodetic and seismological results for 1979 Imperial Valley earthquake. The strategy pursued consists of two principal steps. In the first step, the seismologically-derived coseismic fault slip is taken as a function of position in the fault plane and is applied directly to the three-dimensional dislocation model. In the second step, a physical model of stresses and constitutive parameters is perturbed so as to reproduce the observed fault slip. Hence, the principal features of the coseismic slip pattern are explained by a stress-driven fault model in which: (1) a spatially unresolved asperity is found equivalent to a stress drop of 18 MPa averaged over an area of 15 sq km, and (2) driving stress is essentially absent on the fault segment overlapping the 1940 earthquake rupture zone.

Slade, M. A.↗

Fiber-Optic Lateral-Displacement Sensor

Proposed fiber-optic sensor monitors axial position of shaft or bearing in turbomachine. Device senses position of non-magnetic as well as magnetic material and calibrates before assembly in machine. More compact. Concept extends to measure rotational speed of shaft.

Roschak, Edmund J.↗

The role of photographic parameters in laser speckle or particle image displacement velocimetry

The parameters involved in obtaining the multiple exposure photographs in the laser speckle velocimetry method (to record the light scattering by the seeding particles) were optimized. The effects of the type, concentration, and dimensions of the tracer, the exposure conditions (time between exposures, exposure time, and number of exposures), and the sensitivity and resolution of the film on the quality of the final results were investigated, photographing an experimental flow behind an impulsively started circular cylinder. The velocity data were acquired by digital processing of Young's fringes, produced by point-by-point scanning of a photographic negative. Using the optimal photographing conditions, the errors involved in the estimation of the fringe angle and spacing were of the order of 1 percent for the spacing and +/1 deg for the fringe orientation. The resulting accuracy in the velocity was of the order of 2-3 percent of the maximum velocity in the field.

Lourenco, L.↗

Linear capacitive displacement sensor with frequency readout

A simple, inherently linear technique for measuring changes in the separation of the mirrors of an optical cavity is reported. The capacitor, made up of the reflective metallic coatings, is part of a feedback loop which adjusts the frequency of an oscillator to be proportional to the mirror separation. A linearity of 0.2 percent full scale was achieved for separations up to 0.5 mm with a resolution of 10 nm.

Fritsch, Klaus↗

Analog Sensor Of Large-Amplitude Displacements

Noninvasive device measures large amplitudes at low frequencies. Low-angle, light-sensitive system tracks moving leading edge of model. Applications include opening and closing of automatic doors as far and fast as needed.

Miserentino, Robert↗

Measuring Fan-Blade-Tip Displacements

Magnets and Hall-effect transducers used to monitor tip-to-shroud clearances. Mounting permanent magnet in end of fan blade and monitoring tip-to-shroud distance by use of output of Hall-effect transducers affixed to surface of shroud. Transducers provide real-time information. By placing magnets in each fan-blade tip, complete set monitored sequentially as each blade rotates past sensor. Application in many rotating machines, providing surrounding materials nonmagnetic and temperatures not severe.

Berry, Robert F., Jr.↗

Cusp displacement at the magnetopause for large IMF Y component

The magnetic field orientation just earthward of the dayside magnetopause from 95 ISEE and 11 HEOS crossings with /By/ greater than /Bz/ in the adjacent magnetosheath indicate a statistically significant-1-earth-radius shift of the cusps toward dawn (dusk) in the Northern Hemisphere and dusk (dawn) in the Southern Hemisphere for positive (negative) By. This small shift near the magnetopause and the contrasting large shifts of some reported ionospheric cusp signatures are explained in terms of a finite thickness magnetopause model through which the cusps shift gradually from the inner to the outer edge.

Crooker, N. U.↗

Making Displaced Holograms At Two Wavelengths

Two-wavelength holographic system augmented with pair of prisms to introduce small separation between holograms formed simultaneously at two wavelengths on holographic plate. Principal use in study of flows. Gradients in index of refraction of fluid caused by variations in temperature, concentration, or both. Holography at one wavelength cannot be used to distinguish between two types of variations. Difference between spacings of fringes in photographs reconstructed from holograms taken simultaneously at two different wavelengths manipulated mathematically to determine type of variation.

Witherow, William K.↗

Integrated force method versus displacement method for finite element analysis

A novel formulation termed the integrated force method (IFM) has been developed in recent years for analyzing structures. In this method all the internal forces are taken as independent variables, and the system equilibrium equations (EE's) are integrated with the global compatibility conditions (CC's) to form the governing set of equations. In IFM the CC's are obtained from the strain formulation of St. Venant, and no choices of redundant load systems have to be made, in constrast to the standard force method (SFM). This property of IFM allows the generation of the governing equation to be automated straightforwardly, as it is in the popular stiffness method (SM). In this report IFM and SM are compared relative to the structure of their respective equations, their conditioning, required solution methods, overall computational requirements, and convergence properties as these factors influence the accuracy of the results. Overall, this new version of the force method produces more accurate results than the stiffness method for comparable computational cost.

Patnaik, Surya N.↗