Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DATA CORRELATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Fourth moments reveal the negativity of the Wigner function

The presence of unique quantum correlations is the core of quantum-information processing and general quantum theory. We address the fundamental question of how quantum correlations of a generic quantum system can be probed using correlation functions defined for quasiprobability distributions. In particular, we discuss the possibility of probing the negativity of a quasiprobability by comparing moments of the Wigner function. We show that one must take at least the fourth moments to find the negativity in general and the eighth moments for states with a rotationally invariant Wigner function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainties in nuclear transition matrix elements for neutrinoless {beta}{beta} decay within the projected-Hartree-Fock-Bogoliubov model

The nuclear transition matrix elements M{sup (0{nu})} for the neutrinoless {beta}{beta} decay of {sup 94,96}Zr, {sup 98,100}Mo, {sup 104}Ru, {sup 110}Pd, {sup 128,130}Te, and {sup 150}Nd isotopes in the case of 0{sup +}{yields}0{sup +} transition are calculated using the projected-Hartree-Fock-Bogoliubov wave functions, which are eigenvectors of four different parametrizations of a Hamiltonian with pairing plus multipolar effective two-body interaction. Employing two (three) different parametrizations of Jastrow-type short-range correlations, a set of eight (twelve) different nuclear transition matrix elements M{sup (0{nu})} is built for each decay, whose averages in conjunction with their standard deviations provide an estimate of the model's uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamics of interacting quintessence models: Observational constraints

Interacting quintessence models have been proposed to explain or, at least, alleviate the coincidence problem of late cosmic acceleration. In this paper we are concerned with two aspects of these kind of models: (i) the dynamical evolution of the model of Chimento et al. [L. P. Chimento, A. S. Jakubi, D. Pavon, and W. Zimdahl, Phys. Rev. D 67, 083513 (2003).], i.e., whether its cosmological evolution gives rise to a right sequence of radiation, dark matter, and dark energy-dominated eras, and (ii) whether the dark matter dark energy ratio asymptotically evolves towards a nonzero constant. After showing that the model correctly reproduces these eras, we correlate three data sets that constrain the interaction at three redshift epochs: z{<=}10{sup 4}, z=10{sup 3}, and z=1. We discuss the model selection and argue that even if the model under consideration fulfills both requirements, it is heavily constrained by observation. The prospects that the coincidence problem can be explained by the coupling of dark matter to dark energy are not clearly favored by the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shaping Emission Spectra of Fluorescent Molecules with Single Plasmonic Nanoresonators

We show that plasmonic nanoresonators composed of two gold nanoparticles change not only the intensity but also the spectral shape of the emission of fluorescent molecules. The plasmonic resonance frequency can be tuned by varying the distance between the nanoparticles, which allows us to selectively favor transitions of a fluorescent molecule to a specific vibrational ground state. Experimental data from correlated scattering and fluorescence microscopy agree well with calculations in the framework of generalized Mie theory. Our results show that the widely used description of a dye molecule near a metal surface as a mere two-level system is inadequate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filling the holes in the CaFe 4 As 3 structure: Synthesis and magnetism of CaCo 5 As 3

Here, we investigate single crystals of CaCo 5 As 3 by means of single-crystal x-ray diffraction, microprobe, magnetic susceptibility, heat capacity, and pressure-dependent transport measurements. CaCo 5 As 3 shares the same structure of CaFe 4 As 3 with an additional Co atom filling a lattice vacancy and undergoes a magnetic transition at T M = 16 K associated with a frustrated magnetic order. CaCo 5 As 3 displays metallic behavior and its Sommerfeld coefficient (γ = 70 mJ/mol K 2 ) indicates a moderate enhancement of electron-electron correlations. Transport data under pressures to 2.5 GPa reveal a suppression of T M at a rate of - 0.008 K/GPa. First-principles electronic structure calculations show a complex three-dimensional band structure and magnetic moments that depend on the local environment at each Co site. Our results are compared with previous data on CaFe 4 As 3 and provide a scenario for a magnetically frustrated ground state in this family of compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining the Effects of Environment and Atmospheric Parameters on PV Field Performance

The performance losses due to soiling occurring on any photovoltaic (PV) device are caused by a complex mechanism that involves numerous factors and their interactions. For this reason, the present work analyzes the outputs of reference PV cells installed in various locations, with the aim of contributing to the identification of the most important factors influencing the accumulation of dust on a PV surface. Parameters such as the air-quality indexes, the recurrence and the amount of rainfall and the climate zone are investigated and related to the soiling losses of the PV device.

14 SOLAR ENERGY↗

Characterization and differentiation of aluminum powders used in improvised explosive devices – Part 1: Proof of concept of the utility of particle micromorphometry

Abstract Aluminum (Al) powders are commonly used in improvised explosive devices as metallic fuels, a component of explosive mixtures. These powders can be obtained readily from industrial‐scale and consumer products, and produced using unsophisticated “kitchen chemistry” techniques. This research demonstrates the potential of automated particle micromorphometry for comparisons between known source and questioned Al powders recovered from IEDs, as well as for insight into the method of Al powder manufacture. Al powder samples were obtained from legitimate manufacturers, and 56 samples were produced “in‐house” from Al‐containing spray paints and ball‐milled Al foils. Transmitted light microscope images of Al powder particles were acquired using an automated stage with automated z‐focus; 17 size and shape parameters were measured for all particles. Approximately 37,000–2,500,000 particles/sample were analyzed using an open‐source statistical package with customized code. Dimensionality reduction was required for processing the large datasets: eight of the 17 measured variables were selected based on inspection of the correlation matrix. Data from four subsamples from each of the 56 samples produced using “in‐house” methods were analyzed using ANOVA to assess the within‐ and between‐sample variation. High within‐sample variation was noted; however, ANOVA and post‐hoc Tukey's honestly significant difference (HSD) tests demonstrated that the between‐sample variation was substantially larger than the within‐sample variation. Each sample could be differentiated from all other samples in the test set. Future experiments will focus on ways to reduce the within‐sample variation, and additional statistical and microanalytical methods to classify sources and confidently constrain the method of Al powder manufacture.

Baldaino, JenaMarie↗

Temporal subtraction in chest radiography: Mutual information as a measure of image quality

Purpose: Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or ''lung mask,'' of a previous radiographic image to align with the current image. The gray levels of every pixel in the current image are subtracted from the gray levels of the corresponding pixels in the warped previous image to form a temporal subtraction image. While temporal subtraction images effectively enhance areas of pathologic change, misregistration of the images can mislead radiologists by obscuring the interval change or by creating artifacts that mimic change. The purpose of this study was to investigate the utility of mutual information computed between two registered radiographic chest images as a metric for distinguishing between clinically acceptable and clinically unacceptable temporal subtraction images.Methods: A radiologist subjectively rated the image quality of 138 temporal subtraction images using a 1 (poor) to 5 (excellent) scale. To objectively assess the registration accuracy depicted in the temporal subtraction images, which is the main factor that affects the quality of these images, mutual information was computed on the two constituent registered images prior to their subtraction to generate a temporal subtraction image. Mutual information measures the joint entropy of the current image and the warped previous image, yielding a higher value when the gray levels of spatially matched pixels in each image are consistent. Mutual information values were correlated with the radiologist's subjective ratings. To improve this correlation, mutual information was computed from a spatially limited lung mask, which was cropped from the bottom by 10%-60%. Additionally, the number of gray-level values used in the joint entropy histogram was varied. The ability of mutual information to predict the clinical acceptability of a temporal subtraction image was evaluated through receiver operating characteristic (ROC) analysis. Results: The mean correlation coefficient obtained between mutual information computed on constituent images and the subjective rating of temporal subtraction image quality was 0.785. ROC analysis yielded an average A{sub z} value of 0.852 for the ability of mutual information to distinguish between temporal subtraction images of clinically acceptable and clinically unacceptable quality. Conclusions: The results of this study establish a relationship between mutual information and temporal subtraction registration accuracy and demonstrate the ability of mutual information to objectively indicate the presence of misregistration artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a method to estimate organ doses for pediatric CT examinations

Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

60 APPLIED LIFE SCIENCES↗

SU-D-204-03: Comparison of Patient Positioning Methods Through Modeling of Acute Rectal Toxicity in Intensity Modulated Radiation Therapy for Prostate Cancer. Does Quality of Data Matter More Than the Quantity?

Purpose: To determine if differences in patient positioning methods have an impact on the incidence and modeling of grade >=2 acute rectal toxicity in prostate cancer patients who were treated with Intensity Modulated Radiation Therapy (IMRT). Methods: We compared two databases of patients treated with radiation therapy for prostate cancer: a database of 79 patients who were treated with 7 field IMRT and daily image guided positioning based on implanted gold markers (IGRTdb), and a database of 302 patients who were treated with 5 field IMRT and daily positioning using a trans-abdominal ultrasound system (USdb). Complete planning dosimetry was available for IGRTdb patients while limited planning dosimetry, recorded at the time of planning, was available for USdb patients. We fit Lyman-Kutcher-Burman (LKB) model to IGRTdb only, and Univariate Logistic Regression (ULR) NTCP model to both databases. We perform Receiver Operating Characteristics analysis to determine the predictive power of NTCP models. Results: The incidence of grade >= 2 acute rectal toxicity in IGRTdb was 20%, while the incidence in USdb was 54%. Fits of both LKB and ULR models yielded predictive NTCP models for IGRTdb patients with Area Under the Curve (AUC) in the 0.63 – 0.67 range. Extrapolation of the ULR model from IGRTdb to planning dosimetry in USdb predicts that the incidence of acute rectal toxicity in USdb should not exceed 40%. Fits of the ULR model to the USdb do not yield predictive NTCP models and their AUC is consistent with AUC = 0.5. Conclusion: Accuracy of a patient positioning system affects clinically observed toxicity rates and the quality of NTCP models that can be derived from toxicity data. Poor correlation between planned and clinically delivered dosimetry may lead to erroneous or poorly performing NTCP models, even if the number of patients in a database is large.

60 APPLIED LIFE SCIENCES↗

Discovering polyelemental nanostructures with redistributed plasmonic modes through combinatorial synthesis

Coupling plasmonic and functional materials provides a promising way to generate multifunctional structures. However, finding plasmonic nanomaterials and elucidating the roles of various geometric and dielectric configurations are tedious. This work describes a combinatorial approach to rapidly exploring and identifying plasmonic heteronanomaterials. Symmetry-broken noble/non-noble metal particle heterojunctions (~100 nanometers) were synthesized on multiwindow silicon chips with silicon nitride membranes. The metal types and the interface locations were controlled to establish a nanoparticle library, where the particle morphology and scattering color can be rapidly screened. By correlating structural data with near- and far-field single-particle spectroscopy data, we found that certain low-energy plasmonic modes could be supported across the heterointerface, while others are localized. Furthermore, we found a series of triangular heteronanoplates stabilized by epitaxial Moiré superlattices, which show strong plasmonic responses despite largely comprising a lossy metal (~70 atomic %). These architectures can become the basis for multifunctional and cost-effective plasmonic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio calculations of exciton effects in optical spectra of an α-B{sub 12} crystal

The dielectric functions and energy loss spectrum of electrons of a rhombohedral α-B{sub 12} crystal are studied both in the single-particle and many-particle approximations using Bethe–Salpeter equations. The opposite roles of different contributions to exciton effects are discussed. The anisotropy of dielectric functions is shown, which demonstrates their high sensitivity with respect to the three-dimensional packing of icosahedrons. The influence of the coherent mixing of electronic and exciton states on the redistribution of oscillator strengths is found. The position of the plasmon of valence electrons and the high-frequency permittivity are found to be consistent with experimental data. The correlation between the distribution of oscillator strengths and features of the density of electronic states is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cumulative production of three-nucleon nuclei in {sup 16}Op collisions at a momentum of 3.25 GeV/c per nucleon

The production of cumulative three-nucleon nuclei ({sup 3}H and {sup 3}He) in {sup 16}Op collisions at a momentum of 3.25 GeV/c per nucleon were studied for the first time under conditions of 4{pi} geometry. The slope parameter of the cross section for the production of cumulative three-nucleon nuclei was determined, and new data on correlations of the yields of A = 3 cumulative nuclei, charged particles, and fragments in {sup 16}Op interactions are reported. The properties of cumulative and noncumulative events were found to be substantially different, and evidence for the presence of a common universal feature in the mechanisms for the cumulative production of hadrons and light nuclear fragments was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning for Automating Analysis of Speckle Dynamics

Code used for generating results in the publication for automating analysis of non-equilibrium X-ray Photon Correlation Spectroscopy data, 'Machine Learning for analysis of speckle dynamics: quantification and outlier detection'.

Konstantinova, Tatiana [Brookhaven National Lab. (↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Platelet cloaking of circulating tumour cells in patients with metastatic prostate cancer: Results from ExPeCT, a randomised controlled trial

Background: Circulating tumour cells (CTCs) represent a morphologically distinct subset of cancer cells, which aid the metastatic spread. The ExPeCT trial aimed to examine the effectiveness of a structured exercise programme in modulating levels of CTCs and platelet cloaking in patients with metastatic prostate cancer. Methods: Participants (n = 61) were randomised into either standard care (control) or exercise arms. Whole blood was collected for all participants at baseline (T0), three months (T3) and six months (T6), and analysed for the presence of CTCs, CTC clusters and platelet cloaking. CTC data was correlated with clinico-pathological information. Results: Changes in CTC number were observed within group over time, however no significant difference in CTC number was observed between groups over time. Platelet cloaking was identified in 29.5% of participants. A positive correlation between CTC number and white cell count (WCC) was observed (p = 0.0001), in addition to a positive relationship between CTC clusters and PSA levels (p = 0.0393). Conclusion: The presence of platelet cloaking has been observed in this patient population for the first time, in addition to a significant correlation between CTC number and WCC. Trial registration: ClincalTrials.gov identifier NCT02453139 .

60 APPLIED LIFE SCIENCES↗

Applying machine learning methods to prediction problems of lattice observables

We discuss the prediction of critical behavior of lattice observables in SU(2) and SU(3) gauge theories. We show that feed-forward neural network, trained on the lattice configurations of gauge fields as input data, finds correlations with the target observable, which is also true in the critical region where the neural network has not been trained. We have verified that the neural network constructs a gauge-invariant function and this property does not change over the entire range of the parameter space.

Gerasimeniuk, Nikolai↗