Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

World Record Earned Value Management System Certification for Cleanup of the East Tennessee Technology Park, Oak Ridge, Tennessee, USA - 13181

On projects that require Earned Value Management (EVMS) Certification, it is critical to quickly prepare for and then successfully obtain certification. This is especially true for government contracts. Projects that do poorly during the review are subject to financial penalties to their company and they lose creditability with their customer creating problems with the project at the outset. At East Tennessee Technology Park (ETTP), we began preparing for Department of Energy (DOE) certification early during proposal development. Once the contract was awarded, while still in transition phase from the previous contractor to our new company, we immediately began reviewing the project controls systems that were in place on the project and determined if any replacements needed to be made immediately. The ETTP contract required the scheduling software to be upgraded to Primavera P6 and we determined that no other software changes would be done prior to certification. Next, preparation of the Project Controls System Description (PCSD) and associated procedures began using corporate standards as related to the project controls systems. During the transition phase, development was started on the Performance Measurement Baseline which is the resource loaded schedule used to measure our performance on the project and which is critical to good Earned Value Management of the project. Early on, and throughout the baseline review, there was positive feedback from the Department of Energy that the quality of the new baseline was good. Having this superior baseline also contributed to our success in EVMS certification. The combined companies of URS and CH2M Hill had recent experience with certifications at other Department of Energy sites and we were able to capitalize on that knowledge and experience. Generic PCSD and procedures consistent with our co-operations approach to Earned Value Management were available to us and were easily tailorable to the specifics of our contract and site. We also had corporate EVMS experts available to us so as to draw upon their recent certification experiences with lessons learned. This knowledge was especially helpful for training of personnel that were involved in the certification which included Project Controls, Project Management and Control Account Managers. We were also able to bring in these corporate experts to assist with our training efforts. To assure our readiness for the review, we conducted a 'White Hat' review. The 'White Hat' team consisted of corporate experts in EVMS along with an industry expert in EVMS from Humphrey and Associates. This review identified early any weaknesses that we had so corrections could be enacted prior to the EVMS Certification Readiness Review. It also helped give the evaluators confidence that we had done proper due diligence prior to their arrival. Also critical to our success, was early communication with our evaluators. It is important to start the communications early to ensure you understand the expectations of the certification team and the process that will be used during the certification. Communication through the entire process is critical to understand expectations and issues along the way. Very important to the overall process was management commitment, support and reinforcement. Management made sure that all personnel involved knew the importance and made preparations a priority. This was noted as a key strength by the evaluators during the out-brief. As a result of our preparation, our review yielded one Corrective Action Report (CAR) and two Continuous Improvement Opportunities (CIOs). The Certification team in their out-brief explained that this was the lowest number of CARs and CIOs in the history of EVMS certifications in the DOE Complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New controller for high voltage converter modulator at spallation neutron source

The Spallation Neutron Source (SNS) has developed a new control system for the High Voltage Convertor Modulator (HVCM) at the SNS to replace the original control system which is approaching obsolescence. The original system was based on controllers for similar high voltage systems that were already in use [1]. The new controller, based on National Instruments PXI/FlexRIO Field Programmable Gate Array (FPGA) platform, offers enhancements such as modular construction, flexibility and non-proprietary software. The new controller also provides new capabilities like various methods for modulator pulse flattening, waveform capture, and first fault detection. This paper will discuss the design of the system, including the human machine interface, based on lessons learned at the SNS and other projects. It will also discuss performance and other issues related to its operation in an accelerator facility which requires high availability. To date, 73% of the operational HVCMs have been upgraded to with the new controller, and the remainder are scheduled for completion by mid-2017.

Wezensky, Mark W↗

Fully vs. Sequentially Coupled Loads Analysis of Offshore Wind Turbines

The design and analysis methods for offshore wind turbines must consider the aerodynamic and hydrodynamic loads and response of the entire system (turbine, tower, substructure, and foundation) coupled to the turbine control system dynamics. Whereas a fully coupled (turbine and support structure) modeling approach is more rigorous, intellectual property concerns can preclude this approach. In fact, turbine control system algorithms and turbine properties are strictly guarded and often not shared. In many cases, a partially coupled analysis using separate tools and an exchange of reduced sets of data via sequential coupling may be necessary. In the sequentially coupled approach, the turbine and substructure designers will independently determine and exchange an abridged model of their respective subsystems to be used in their partners' dynamic simulations. Although the ability to achieve design optimization is sacrificed to some degree with a sequentially coupled analysis method, the central question here is whether this approach can deliver the required safety and how the differences in the results from the fully coupled method could affect the design. This work summarizes the scope and preliminary results of a study conducted for the Bureau of Safety and Environmental Enforcement aimed at quantifying differences between these approaches through aero-hydro-servo-elastic simulations of two offshore wind turbines on a monopile and jacket substructure.

17 WIND ENERGY↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Design of a Microgrid Transition Controller II: System Recovery Under Abnormal Conditions: Preprint

This paper presents a microgrid transition controller for managing emergency operation when the microgrid experiences a system blackout caused by an internal or external fault. The developed transition controller consists of various application function blocks, including normal operation, emergency operation, and coordination between them. The developed microgrid transition controller is validated by a sample microgrid, and two test cases are investigated: islanded black start and grid-connected black start. The simulation results demonstrate the feasibility and effectiveness of the proposed microgrid transition controller for handling emergency operation and transitioning to normal operation.

14 SOLAR ENERGY↗

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Experimental Investigation of Gas/Slag/Matte/Tridymite Equilibria in the Cu-Fe-O-S-Si System in Controlled Atmospheres: Development of Technique

The majority of primary pyrometallurgical copper making processes involve the formation of two immiscible liquid phases, i.e., matte product and the slag phase. There are significant gaps and discrepancies in the phase equilibria data of the slag and the matte systems due to issues and difficulties in performing the experiments and phase analysis. The present study aims to develop an improved experimental methodology for accurate characterisation of gas/slag/matte/tridymite equilibria in the Cu-Fe-O-S-Si system under controlled atmospheres. The experiments involve high-temperature equilibration of synthetic mixtures on silica substrates in CO/CO{sub 2}/SO{sub 2}/Ar atmospheres, rapid quenching of samples into water, and direct composition measurement of the equilibrium phases using Electron Probe X-ray Microanalysis (EPMA). A four-point-test procedure was applied to ensure the achievement of equilibrium, which included the following: (i) investigation of equilibration as a function of time, (ii) assessment of phase homogeneity, (iii) confirmation of equilibrium by approaching from different starting conditions, and (iv) systematic analysis of the reactions specific to the system. An iterative improved experimental methodology was developed using this four-point-test approach to characterize the complex multi-component, multi-phase equilibria with high accuracy and precision. The present study is a part of a broader overall research program on the characterisation of the multi-component (Cu-Fe-O-S-Si-Al-Ca-Mg), multi-phase (gas/slag/matte/metal/solids) systems with minor elements (Pb, Zn, As, Bi, Sn, Sb, Ag, and Au).

36 MATERIALS SCIENCE↗

A Game Changer: Electrifying Remote Communities by Using Isolated Microgrids

Microgrids, as self-contained entities, are of increasing interest in modern electric grids. Microgrids provide a sustainable solution to aggregate distributed energy resources (DERs) [e.g., photovoltaics (PVs), wind turbines], energy storage, and loads in a localized manner, especially in distribution systems. As a controllable unit, a microgrid can manage and balance the source and load power inside it to ensure stable and reliable operation. Moreover, through coordination with upper-level control systems, it can be dispatched and respond to the control commands issued by the central controller in the distribution system-in other words, a system that is effectively a distribution management system (DMS).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control and optimization system and method for chemical looping processes

A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control and optimization system and method for chemical looping processes

A control system for optimizing a chemical loop system includes one or more sensors for measuring one or more parameters in a chemical loop. The sensors are disposed on or in a conduit positioned in the chemical loop. The sensors generate one or more data signals representative of an amount of solids in the conduit. The control system includes a data acquisition system in communication with the sensors and a controller in communication with the data acquisition system. The data acquisition system receives the data signals and the controller generates the control signals. The controller is in communication with one or more valves positioned in the chemical loop. The valves are configured to regulate a flow of the solids through the chemical loop.

47 OTHER INSTRUMENTATION↗

Linux-Based Software Control for Xenon Systems

This paper will review software control solutions for systems requiring automated control and analysis. Written in the C++ language under the Linux operating system (OS), a client/server architecture was developed for automated systems enabling modularized processes to perform system control. In this scheme, narrowly focused clients and servers communicate with each other to perform tasks necessary for system execution. Each hardware interface, such as analog input/output modules, instrumentation, and detectors, have a server associated with it that can be accessed individually with various client interface programs. These servers also inherently support reporting all sensor values to a state-of-health server. One advantage to this software architecture is that all software servers can be accessed and altered independently without stopping the entire control system providing flexibility during development and operation. Automation is achieved using a state-machine based control program that implements the process necessary to run the system. The state-machine provides a well-defined process flow with each state defining one step in the overall control process. The state-machine framework is highly flexible. During development, states can easily be modified, added, or removed as needed.

Suarez, Reynold↗

On the evaluation and selection of network-level traffic control policies: Perimeter control, TUC, and their combination

Perimeter control (PC) of urban traffic networks can be effective in increasing network-wide efficiency. PC operates on the border of a protected region of a traffic network. Most studies thus far considered fixed-time plans for the inner part of these regions. A few studies have shown that combining PC with locally actuated or decentralized traffic control systems may have positive effects on traffic performance, including better-defined Network Macroscopic Fundamental Diagrams (NMFDs), increased network throughput, and reduced delays. The Traffic-responsive Urban Control (TUC) is a real-time network-wide traffic control system with particular design characteristics, such as the balancing of link's occupancies and an inherent gating feature. These characteristics suggest that TUC may enhance the traffic network performance when combined with PC whilst improving the resulting NMFDs and network throughput and delays. Here, in this work, we investigate the effect of feedback perimeter control (FPC), TUC, and their combination on the NMFD and on the traffic conditions of general traffic and public transport in the microsimulation of a realistic model of the Christchurch Central Business District in New Zealand. We perform a thorough investigation of practical aspects of both control strategies and their combination, including parameter tuning and infrastructure requirements, and how they may affect the control system choice. Results show higher throughput and less hysteresis on the NMFDs, particularly when TUC is involved. PC provides benefits concentrated in the protected region which can greatly benefit public transportation if there is an overlap with the transit network. The combination of TUC and FPC boosts network-wide throughput.

33 ADVANCED PROPULSION SYSTEMS↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs: Preprint

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Toward particle accelerator machine state embeddings as a modality for large language models

Understanding and diagnosing the state of a particle accelerator requires navigating high-dimensional control system data, often involving hundreds of interdependent parameters. We propose a novel multimodal embedding framework that jointly learns representations of machine states from both numerical control system readouts and natural language descriptions. This enables the translation of complex machine conditions into human-readable summaries while maintaining fidelity to the underlying physical system. The obtained embeddings are subsequently adapted to an open-weights large language model via cross-attention conditioning. We demonstrate a first implementation trained on European XFEL machine state data. This work covers the embedding model architecture, training methodology, and presents initial examples demonstrating the model's capabilities in action. Due to the general concept of machine state, the model can be easily adapted to other facilities and control system environments.

Accelerator Physics↗

An open-source data storage and visualization platform for collaborative qubit control

Developing collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the lack of dedicated data management platforms presents a significant obstacle to progress, highlighting the necessity for essential assistive tools tailored for this purpose. Current qubit control systems are unable to handle complicated management of extensive calibration data and do not support effectively visualizing intricate quantum experiment outcomes. In this paper, we introduce Qubit Control Storage and Visualization ( QubiCSV ), a platform specifically designed to meet the demands of quantum computing research, focusing on the storage and analysis of calibration and characterization data in qubit control systems. As an open-source tool, QubiCSV facilitates efficient data management of quantum computing, providing data versioning capabilities for data storage and allowing researchers and programmers to interact with qubits in real time. The insightful visualization are developed to interpret complex quantum experiments and optimize qubit performance. QubiCSV not only streamlines the handling of qubit control system data but also improves the user experience with intuitive visualization features, making it a valuable asset for researchers in the quantum computing domain.

97 MATHEMATICS AND COMPUTING↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗