Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Graphics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants

Purpose: Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed “incision-less surgery.” Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy. Methods: A clinical Philips Sonalleve MRgFUS system was expanded to perform transcranial treatment. A five degree-of-freedom MR-conditional robot was designed and manufactured using MR compatible materials. The robot electronics and control were integrated into existing Philips electronics and software interfaces. The user commands the position of the robot with a graphical user interface, and is presented with real-time MR imaging of the patient throughout the surgery. The robot is validated through a series of experiments that characterize accuracy, signal-to-noise ratio degeneration of an MR image as a result of the robot, MR imaging artifacts generated by the robot, and the robot’s ability to operate in a representative surgical environment inside an MR machine. Results: Experimental results show the robot responds reliably within an MR environment, has achieved 0.59 ± 0.25 mm accuracy, does not produce severe MR-imaging artifacts, has a workspace providing sufficient coverage of a neonatal brain, and can manipulate a 5 kg payload. A full system demonstration shows these characteristics apply in an application environment. Conclusions: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment. An MR conditional robot has been designed and manufactured to design specifications. The system has demonstrated its feasibility as a platform for MRgFUS interventions for neonatal patients. The success of the system in experimental trials suggests that it is ready to be used for validation of the transcranial intervention in animal studies.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-02: SIMAC: A Simulation Tool for Teaching Linear Accelerator Physics

Purpose: The first goal of this work is to develop software that can simulate the physics of linear accelerators (linac). The second goal is to show that this simulation tool is effective in teaching linac physics to medical physicists and linac service engineers. Methods: Linacs were modeled using analytical expressions that can correctly describe the physical response of a linac to parameter changes in real time. These expressions were programmed with a graphical user interface in order to produce an environment similar to that of linac service mode. The software, “SIMAC”, has been used as a learning aid in a professional development course 3 times (2014 – 2016) as well as in a physics graduate program. Exercises were developed to supplement the didactic components of the courses consisting of activites designed to reinforce the concepts of beam loading; the effect of steering coil currents on beam symmetry; and the relationship between beam energy and flatness. Results: SIMAC was used to teach 35 professionals (medical physicists; regulators; service engineers; 1 week course) as well as 20 graduate students (1 month project). In the student evaluations, 85% of the students rated the effectiveness of SIMAC as very good or outstanding, and 70% rated the software as the most effective part of the courses. Exercise results were collected showing that 100% of the students were able to use the software correctly. In exercises involving gross changes to linac operating points (i.e. energy changes) the majority of students were able to correctly perform these beam adjustments. Conclusion: Software simulation(SIMAC), can be used to effectively teach linac physics. In short courses, students were able to correctly make gross parameter adjustments that typically require much longer training times using conventional training methods.

60 APPLIED LIFE SCIENCES↗

Compact video content representation for video coding using low multi-linear tensor rank approximation with dynamic core tensor order

Tensor is a multi-way representation of an entity that is widely used in many applications of mathematics and physics. The wide range of tensor algebra operations attract the researchers of graphical and vision field to identify unique methods for various applications such as segmentation, compression, indexing and so on. In this paper, low multi-linear rank approximation of a tensor is used for decomposition so as to perform compression on a video that is represented as a 4D tensor. Thus, the encoder has blocks for (1) multilinear rank approximation method so as to aid decomposition, (2) sparsity removal of residual data to reduce the required memory storage to a small level, (3) quantization on the sparse less residual data and (4) LZ77 dictionary coding for the video. The decoder uses a tensor reconstruction block along with residual error correction block that reduces loss/error in the reconstructed video. The size of core tensor is an important factor in rank approximation. It is identified at run time depending on the video contents. This size is determined adaptively using Tikhonov’s regularization method. The best value of core tensor size is identified with the corner of L-curve which preserves the video contents from heavy loss/error. Experimental results of the proposed work on comparison with H.264/AVC compression method indicate that the proposed method achieves up to 10% improvement in compression ratio with the least amount of loss and a maximum signal to noise ratio of 0.14. The proposed system gives better compression ratio than H.265 for videos with more number of frames without compromising quality.

97 MATHEMATICS AND COMPUTING↗

TH-C-12A-12: Veritas: An Open Source Tool to Facilitate User Interaction with TrueBeam Developer Mode

Purpose: To address the challenges of creating delivery trajectories and imaging sequences with TrueBeam Developer Mode, a new open-source graphical XML builder, Veritas, has been developed, tested and made freely available. Veritas eliminates most of the need to understand the underlying schema and write XML scripts, by providing a graphical menu for each control point specifying the state of 30 mechanical/dose axes. All capabilities of Developer Mode are accessible in Veritas. Methods: Veritas was designed using QT Designer, a ‘what-you-is-what-you-get’ (WYSIWIG) tool for building graphical user interfaces (GUI). Different components of the GUI are integrated using QT's signals and slots mechanism. Functionalities are added using PySide, an open source, cross platform Python binding for the QT framework. The XML code generated is immediately visible, making it an interactive learning tool. A user starts from an anonymized DICOM file or XML example and introduces delivery modifications, or begins their experiment from scratch, then uses the GUI to modify control points as desired. The software automatically generates XML plans following the appropriate schema. Results: Veritas was tested by generating and delivering two XML plans at Brigham and Women's Hospital. The first example was created to irradiate the letter ‘B’ with a narrow MV beam using dynamic couch movements. The second was created to acquire 4D CBCT projections for four minutes. The delivery of the letter ‘B’ was observed using a 2D array of ionization chambers. Both deliveries were generated quickly in Veritas by non-expert Developer Mode users. Conclusion: We introduced a new open source tool Veritas for generating XML plans (delivery trajectories and imaging sequences). Veritas makes Developer Mode more accessible by reducing the learning curve for quick translation of research ideas into XML plans. Veritas is an open source initiative, creating the possibility for future developments and collaboration with other researchers. I am an employee of Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

NDMAS implementation and data qualification for accident tolerant fuel experiments

In order to meet quality and regulatory requirements associated with the U.S. Department of Energy Accident Tolerant Fuels (ATF) experiments, all data and documentation associated with ATF component fabrication, characterization, traceability, testing and post irradiation examination are being managed using the Nuclear Data Management and Analysis System (NDMAS). NDMAS melds commercial off-the-shelf software to provide the full range of needed functionality. The core component of NDMAS is the SAS Enterprise Business Intelligence software, which provides data manipulation, statistical and graphical capabilities, and delivery of live content to web pages. Content delivery to both Idaho National Laboratory researchers and external users via a web interface is managed using SharePoint, which is access-controlled. Additionally, scripts, macros, and commercial wrappers may be used or written by the NDMAS team to control interfaces between SAS and the structured query language server, where much of the data reside. ATF experiment data and documentation stored in the NDMAS database may be utilized to support Nuclear Regulatory Commission licensing of ATF concepts for commercial Light Water Reactor demonstration. Therefore, Data Qualification Plans are being developed to screen and tag all document and data input for ATR water loop testing, Transient Reactor Testing (TREAT), and post irradiation examination. A project-wide document library has been created in the ATF NDMAS SharePoint Site for general unrestricted document and information access. Restricted libraries have also been created to allow individual customer access to restricted documents. Data from ATR water loop instrumented lead experimentation, TREAT, and post-irradiation examination will be available to program participants on the SharePoint site as they are collected. This offers a unique capability for team collaboration while these tests are being conducted. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MO-FG-BRA-01: Development of An Image-Guided Dosimetric Planning System for Injectable Brachytherapy Using ELP Nanoparticles

Purpose: To develop, validate, and evaluate a methodology for determining dosimetry for intratumoral injections of elastin-like-polypeptide (ELP) brachytherapy nanoparticles. These organic-polymer-based nanoparticles are injectable, biodegradable, and genetically tunable. We present a genetically encoded polymer-solution, composed of novel radiolabeled-ELP nanoparticles that are custom-designed to self-assemble into a local source upon intratumoral injection. Our preliminary results of a small animal study demonstrate 100% tumor response, effective radionuclide retention-rates, strong in vivo stability, and no polymer-induced toxicities. While our approach is therefore highly promising for improved brachytherapy, the current workflow lacks a dosimetry framework. Methods: We are developing a robust software framework that provides image-guided dosimetric-planning capabilities for ELP brachytherapy. The user graphically places ELP injection sites within a µCT-planning-image, and independently defines each injection volume, concentration, and radioisotope to be used. The resulting internal dosimetry is then pre-determined by first modeling post-injection ELP advection-diffusion, and then calculating the resulting dose distribution based on a point- dose-kernel-convolution algorithm. We have experimentally measured ELP steady-state concentrations via µSPECT acquisition, and validated our dose calculation algorithm against Monte Carlo simulations of several radioactivity distributions. Finally, we have investigated potential advantages and limitations of various ELP injection parameters. Results: The µSPECT results demonstrated inhomogeneous steady-state distributions of ELP in tissue, and Monte Carlo radioactivity distributions were designed accordingly. Our algorithm yielded a root-mean-square-error of less than 2% for each distribution tested (average root-mean-square-error was 0.73%). Dose-Volume-Histogram analysis of five different plans showed how strategic injection placement, and an injection volume-tapering technique, could be used to achieve D95% target coverage. Conclusion: We have preliminarily developed a novel planning framework for ELP brachytherapy. Its dosimetry accuracy has been validated against Monte Carlo, and we have started to investigate the potential advantages of injection-based planning. This system, once fully developed, will serve as the technical foundation for our novel approach.

60 APPLIED LIFE SCIENCES↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Toward the validation of crowdsourced experiments for lightness perception

Crowdsource platforms have been used to study a range of perceptual stimuli such as the graphical perception of scatterplots and various aspects of human color perception. Given the lack of control over a crowdsourced participant’s experimental setup, there are valid concerns on the use of crowdsourcing for color studies as the perception of the stimuli is highly dependent on the stimulus presentation. Here, we propose that the error due to a crowdsourced experimental design can be effectively averaged out because the crowdsourced experiment can be accommodated by the Thurstonian model as the convolution of two normal distributions, one that is perceptual in nature and one that captures the error due to variability in stimulus presentation. Based on this, we provide a mathematical estimate for the sample size needed to produce a crowdsourced experiment with the same power as the corresponding in-person study. We tested this claim by replicating a large-scale, crowdsourced study of human lightness perception with a diverse sample with a highly controlled, in-person study with a sample taken from psychology undergraduates. Our claim was supported by the replication of the results from the latter. These findings suggest that, with sufficient sample size, color vision studies may be completed online, giving access to a larger and more representative sample. With this framework at hand, experimentalists have the validation that choosing either many online participants or few in person participants will not sacrifice the impact of their results.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-468: Efficient Scanning Data Analysis for TomoTherapy

Purpose: The standard TomoTherapy 2D scanning system requires manual analysis using spreadsheets or similar software. Manual analysis is time consuming and does not allow efficient use of the medical physicist or timely results that may indicate issues during the acquisition of data. The purpose of this study is to determine if an in-house solution can provide timely analysis of TomoTherapy scan data. Methods: A custom MATLAB program utilizing a streamlined graphical interface was developed to interpret the native scanning data acquired by the TomoTherapy Electrometer Measurement System (TEMS). The gold beam data provided by the manufacturer was used as a baseline for the acquired data. Two separate sets of scan data were used including longitudinal, transverse, and percent depth dose (PDD). The scan data were compared visually in an overlay and analytically for each beam width using the full width half max (FWHM) for longitudinal profiles and difference inside the field core for the transverse profiles as recommended by TG-148. A plot of the PDD percent error at each point along the curve was generated to show agreement. The time to analysis was measured on a laptop running an Intel i5 processor with 8GB of RAM. Results: The software program required on average less than 5 seconds to load and analyze the results. No conversion or reformatting of the data was required. This allowed real-time visualization of the comparison to the gold beam data as well as the parameters recommended by TG-148. The average percent difference was 0.3% for the longitudinal profiles and 0.1% for the transverse profiles. All PDD data was less than 1% different beyond dmax. Conclusion: We have developed a tool to analyze TomoTherapy scan data in real-time. This allows an efficient method to perform beam commissioning, annual QA, and adjust the beam parameters if necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrical and optical properties of nitrogen doped SnO{sub 2} thin films deposited on flexible substrates by magnetron sputtering

Graphical abstract: The best SnO{sub 2}:N TCO film: about 80% transmittance and 9.1 × 10{sup −4} Ω cm. - Highlights: • Nitrogen-doped tin oxide film was deposited on PET by RF-magnetron sputtering. • Effects of oxygen partial pressure on the properties of thin films were investigated. • For SnO{sub 2}:N film, visible light transmittance was 80% and electrical resistivity was 9.1 × 10{sup −4} Ω cm. - Abstract: Nitrogen-doped tin oxide (SnO{sub 2}:N) thin films were deposited on flexible polyethylene terephthalate (PET) substrates at room temperature by RF-magnetron sputtering. Effects of oxygen partial pressure (0–4%) on electrical and optical properties of thin films were investigated. Experimental results showed that SnO{sub 2}:N films were amorphous state, and O/Sn ratios of SnO{sub 2}:N films were deviated from the standard stoichiometry 2:1. Optical band gap of SnO{sub 2}:N films increased from approximately 3.10 eV to 3.42 eV as oxygen partial pressure increased from 0% to 4%. For SnO{sub 2}:N thin films deposited on PET, transmittance was about 80% in the visible light region. The best transparent conductive oxide (TCO) deposited on flexible PET substrates was SnO{sub 2}:N thin films preparing at 2% oxygen partial pressure, the transmittance was about 80% and electrical conductivity was about 9.1 × 10{sup −4} Ω cm.

36 MATERIALS SCIENCE↗

Evaluation of the FIR Example using Xilinx Vivado High-Level Synthesis Compiler

Compared to central processing units (CPUs) and graphics processing units (GPUs), field programmable gate arrays (FPGAs) have major advantages in reconfigurability and performance achieved per watt. This development flow has been augmented with high-level synthesis (HLS) flow that can convert programs written in a high-level programming language to Hardware Description Language (HDL). Using high-level programming languages such as C, C++, and OpenCL for FPGA-based development could allow software developers, who have little FPGA knowledge, to take advantage of the FPGA-based application acceleration. This improves developer productivity and makes the FPGA-based acceleration accessible to hardware and software developers. Xilinx Vivado HLS compiler is a high-level synthesis tool that enables C, C++ and System C specification to be directly targeted into Xilinx FPGAs without the need to create RTL manually. The white paper [1] published recently by Xilinx uses a finite impulse response (FIR) example to demonstrate the variable-precision features in the Vivado HLS compiler and the resource and power benefits of converting floating point to fixed point for a design. To get a better understanding of variable-precision features in terms of resource usage and performance, this report presents the experimental results of evaluating the FIR example using Vivado HLS 2017.1 and a Kintex Ultrascale FPGA. In addition, we evaluated the half-precision floating-point data type against the double-precision and single-precision data type and present the detailed results.

97 MATHEMATICS AND COMPUTING↗

A Surveillance Infrastructure for Malaria Analytics: Provisioning Data Access and Preservation of Interoperability

Background: According to the World Health Organization, malaria surveillance is weakest in countries and regions with the highest malaria burden. A core obstacle is that the data required to perform malaria surveillance are fragmented in multiple data silos distributed across geographic regions. Furthermore, consistent integrated malaria data sources are few, and a low degree of interoperability exists between them. As a result, it is difficult to identify disease trends and to plan for effective interventions. Objective: We propose the Semantics, Interoperability, and Evolution for Malaria Analytics (SIEMA) platform for use in malaria surveillance based on semantic data federation. Using this approach, it is possible to access distributed data, extend and preserve interoperability between multiple dynamic distributed malaria sources, and facilitate detection of system changes that can interrupt mission-critical global surveillance activities. Methods: We used Semantic Automated Discovery and Integration (SADI) Semantic Web Services to enable data access and improve interoperability, and the graphical user interface-enabled semantic query engine HYDRA to implement the target queries typical of malaria programs. We implemented a custom algorithm to detect changes to community-developed terminologies, data sources, and services that are core to SIEMA. This algorithm reports to a dashboard. Valet SADI is used to mitigate the impact of changes by rebuilding affected services. Results: We developed a prototype surveillance and change management platform from a combination of third-party tools, community-developed terminologies, and custom algorithms. We illustrated a methodology and core infrastructure to facilitate interoperable access to distributed data sources using SADI Semantic Web services. This degree of access makes it possible to implement complex queries needed by our user community with minimal technical skill. We implemented a dashboard that reports on terminology changes that can render the services inactive, jeopardizing system interoperability. Using this information, end users can control and reactively rebuild services to preserve interoperability and minimize service downtime. Conclusions: We introduce a framework suitable for use in malaria surveillance that supports the creation of flexible surveillance queries across distributed data resources. The platform provides interoperable access to target data sources, is domain agnostic, and with updates to core terminological resources is readily transferable to other surveillance activities. A dashboard enables users to review changes to the infrastructure and invoke system updates. The platform significantly extends the range of functionalities offered by malaria information systems, beyond the state-of-the-art.

60 APPLIED LIFE SCIENCES↗

Calibrating a finite-strain phase-field model of fracture for bonded granular materials with uncertainty quantification

To study the mechanical behavior of mock high explosives, an experimental and simulation program was developed to calibrate, with quantified uncertainty, a material model of the bonded granular material Idoxuridine and nitroplasticized Estane-5703. This paper reports on the efficacy of such a framework as a generalizable methodology for calibrating material models against experimental data with uncertainty quantification. Additionally, this paper studies the effect of two manufacturing temperatures and three initial granular configurations on the unconfined compressive behavior of the resulting bonded granular materials. In each of these cases, the same calibration framework was used; in that, hundreds of high-fidelity direct numerical simulations using a new, graphics processing unit-enabled, high-performance finite element method software, Ratel, were run to calibrate a finite-strain phase-field fracture model against experimental data. It was found that manufacturing temperature influenced the elastic response of the mock high explosives, with higher temperatures yielding a stiffer response. By contrast, it was found that the initial configuration of the grains had a negligible impact on the overall behavior of the mock high explosives though it remains possible that local damage accumulation within the specimens could be altered by the initial configurations. Overall, the calibration framework was successful at creating well-calibrated models, showing its usefulness as an engineering and scientific tool.

36 MATERIALS SCIENCE↗

Ultra-secure RF Tags for Safeguards and Security - SBIR Phase II Final Report

This is the Final Report for the DOE Phase II SBIR project “Ultra-secure RF Tags for Safeguards and Security.” The topics covered herein include technical progress made, progress against the planned milestones and deliverables, project outcomes (results, collaborations, intellectual property, etc.), and a discussion on future expectations of deployment and impacts of the results of this work. In brief, all planned work for the project was successfully completed, on or ahead of schedule and on budget. The major accomplishment was the successful development of a very advanced passive ultra-secure RFID tag system with combined security features unmatched by any commercially available ones. These tags have high-level dynamic encrypted authentication, a novel tamper-proofing mechanism, system software including graphical user interfaces and networking, and integration with a fiber-optic seal mechanism. This is all accomplished passively (with no battery) by incorporating sophisticated hardware in the tag which harvests the energy from the RFID readers that are interrogating the tag. Based on initial feedback (and deployments) at DOE’s Lawrence Livermore National Laboratory (LLNL), it is anticipated these tags and their offspring will meet DOE and international community needs for highly secure RFID systems. Beyond the accomplishment of those original objectives for the ultra-secure RF tags, major new spin-off thrusts from the original work were identified and successfully pursued with the cognizance of the DOE sponsor office. In particular, new classes of less sophisticated RFID tags were developed whose lineage derives from the core R&D thrusts of this SBIR. These RF “tag variants” have some, but not necessarily all, of the advanced characteristics described above and can therefore be less expensive and meet far wider markets. With customer pull from the DOE and its national laboratories, new RFID tags and systems (including custom readers and software) for government needs in asset management and tracking were developed. These were tested at a national laboratory and other government facilities, and resulted in immediate procurement actions by the government and deployment of these new systems. Thus, commercialization of the results of this Phase II DOE SBIR was already underway before the end of the SBIR itself. More importantly, operations involving asset management at selected DoE and government sites are already being impacted favorably and could have much broader impacts in the near future.

42 ENGINEERING↗

Scaling Input Distributions for Probabilistic Models - 19472

It is important to address scaling issues when building models to support risk-based decisions for radioactive waste disposal sites. Currently, probabilistic risk assessment and probabilistic performance assessment models are run for multiple realizations where each realization uses one value from each input distribution over the entire modeled time. The input distributions represent the current state of knowledge in the mean of the input variable over the spatial region of interest and over the time period of the model run. This paper focuses on the time factor in input distribution scaling because it presents more serious conceptual and distributional challenges than the spatial factor. One of the challenges in temporal scaling is the effect of non-linearity on propagation of distribution uncertainty through to uncertainty in results. Radioactive waste disposal models tend to have both linear and non-linear components in their models. Dose assessment calculations are typically represented by linear models, while contaminant transport models have linear and non-linear components. In principle, temporal scaling of input parameter distributions for a linear model is straightforward, but scaling of input distributions for non-linear models is not. This paper uses examples to investigate the effects of input distribution temporal scaling on simple linear and non-linear models. Different scaling scenarios were investigated by comparing three analysis tools: analytical mathematical representations, statistical software programming, and GoldSim Monte Carlo simulation software. R statistical software is an open source statistical programming language often used for statistical analyses and graphical representation of data. GoldSim is a robust probabilistic dynamic modeling platform used in performance assessment modeling of radioactive waste sites. A simple linear model, a quadratic model and a multiplicative model were the cases explored for each of these tools. For the three analysis tools considered and with each of the scaling cases, 1,000 realizations were implemented from distributions of the random variables of interest. This is a sufficient number of realizations for simple models to capture the model space. An annual temporal resolution of a 100-year simulation period was chosen for all models and analysis tools. The effects of temporal scaling were demonstrated by investigating two different options for time scaling. Option 1 was set up so that the input distributions represented the expected value on an annual time scale, and a new value from that distribution was chosen every year (at every time step which equaled a year) for 100 years. In Option 2, the input distributions were scaled to represent the expected mean value of the input variable over the 100 years of simulation, and one value from that distribution was chosen for the entire elapsed time. Results show agreement across the three analysis tools. As expected, the linear models have identical results for the two different scaling Options, and the non-linear models diverge in the results for different time scale implementation. The implications of this work point to the need for careful consideration of input distribution temporal scaling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods, software and datasets to verify DVH calculations against analytical values: Twenty years late(r)

Purpose: The authors designed data, methods, and metrics that can serve as a standard, independent of any software package, to evaluate dose-volume histogram (DVH) calculation accuracy and detect limitations. The authors use simple geometrical objects at different orientations combined with dose grids of varying spatial resolution with linear 1D dose gradients; when combined, ground truth DVH curves can be calculated analytically in closed form to serve as the absolute standards. Methods: DICOM RT structure sets containing a small sphere, cylinder, and cone were created programmatically with axial plane spacing varying from 0.2 to 3 mm. Cylinders and cones were modeled in two different orientations with respect to the IEC 1217 Y axis. The contours were designed to stringently but methodically test voxelation methods required for DVH. Synthetic RT dose files were generated with 1D linear dose gradient and with grid resolution varying from 0.4 to 3 mm. Two commercial DVH algorithms—PINNACLE (Philips Radiation Oncology Systems) and PlanIQ (Sun Nuclear Corp.)—were tested against analytical values using custom, noncommercial analysis software. In Test 1, axial contour spacing was constant at 0.2 mm while dose grid resolution varied. In Tests 2 and 3, the dose grid resolution was matched to varying subsampled axial contours with spacing of 1, 2, and 3 mm, and difference analysis and metrics were employed: (1) histograms of the accuracy of various DVH parameters (total volume, D{sub max}, D{sub min}, and doses to % volume: D99, D95, D5, D1, D0.03 cm{sup 3}) and (2) volume errors extracted along the DVH curves were generated and summarized in tabular and graphical forms. Results: In Test 1, PINNACLE produced 52 deviations (15%) while PlanIQ produced 5 (1.5%). In Test 2, PINNACLE and PlanIQ differed from analytical by >3% in 93 (36%) and 18 (7%) times, respectively. Excluding D{sub min} and D{sub max} as least clinically relevant would result in 32 (15%) vs 5 (2%) scored deviations for PINNACLE vs PlanIQ in Test 1, while Test 2 would yield 53 (25%) vs 17 (8%). In Test 3, statistical analyses of volume errors extracted continuously along the curves show PINNACLE to have more errors and higher variability (relative to PlanIQ), primarily due to PINNACLE’s lack of sufficient 3D grid supersampling. Another major driver for PINNACLE errors is an inconsistency in implementation of the “end-capping”; the additional volume resulting from expanding superior and inferior contours halfway to the next slice is included in the total volume calculation, but dose voxels in this expanded volume are excluded from the DVH. PlanIQ had fewer deviations, and most were associated with a rotated cylinder modeled by rectangular axial contours; for coarser axial spacing, the limited number of cross-sectional rectangles hinders the ability to render the true structure volume. Conclusions: The method is applicable to any DVH-calculating software capable of importing DICOM RT structure set and dose objects (the authors’ examples are available for download). It includes a collection of tests that probe the design of the DVH algorithm, measure its accuracy, and identify failure modes. Merits and applicability of each test are discussed.

60 APPLIED LIFE SCIENCES↗

Multiscale Universal Interface: A concurrent framework for coupling heterogeneous solvers

Graphical abstract: - Abstract: Concurrently coupled numerical simulations using heterogeneous solvers are powerful tools for modeling multiscale phenomena. However, major modifications to existing codes are often required to enable such simulations, posing significant difficulties in practice. In this paper we present a C++ library, i.e. the Multiscale Universal Interface (MUI), which is capable of facilitating the coupling effort for a wide range of multiscale simulations. The library adopts a header-only form with minimal external dependency and hence can be easily dropped into existing codes. A data sampler concept is introduced, combined with a hybrid dynamic/static typing mechanism, to create an easily customizable framework for solver-independent data interpretation. The library integrates MPI MPMD support and an asynchronous communication protocol to handle inter-solver information exchange irrespective of the solvers' own MPI awareness. Template metaprogramming is heavily employed to simultaneously improve runtime performance and code flexibility. We validated the library by solving three different multiscale problems, which also serve to demonstrate the flexibility of the framework in handling heterogeneous models and solvers. In the first example, a Couette flow was simulated using two concurrently coupled Smoothed Particle Hydrodynamics (SPH) simulations of different spatial resolutions. In the second example, we coupled the deterministic SPH method with the stochastic Dissipative Particle Dynamics (DPD) method to study the effect of surface grafting on the hydrodynamics properties on the surface. In the third example, we consider conjugate heat transfer between a solid domain and a fluid domain by coupling the particle-based energy-conserving DPD (eDPD) method with the Finite Element Method (FEM)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification of RESRAD-RDD. (Version 2.01)

In this report, the results generated by RESRAD-RDD version 2.01 are compared with those produced by RESRAD-RDD version 1.7 for different scenarios with different sets of input parameters. RESRAD-RDD version 1.7 is spreadsheet-driven, performing calculations with Microsoft Excel spreadsheets. RESRAD-RDD version 2.01 revamped version 1.7 by using command-driven programs designed with Visual Basic.NET to direct calculations with data saved in Microsoft Access database, and re-facing the graphical user interface (GUI) to provide more flexibility and choices in guideline derivation. Because version 1.7 and version 2.01 perform the same calculations, the comparison of their results serves as verification of both versions. The verification covered calculation results for 11 radionuclides included in both versions: Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90. At first, all nuclide-specific data used in both versions were compared to ensure that they are identical. Then generic operational guidelines and measurement-based radiation doses or stay times associated with a specific operational guideline group were calculated with both versions using different sets of input parameters, and the results obtained with the same set of input parameters were compared. A total of 12 sets of input parameters were used for the verification, and the comparison was performed for each operational guideline group, from A to G, sequentially. The verification shows that RESRAD-RDD version 1.7 and RESRAD-RDD version 2.01 generate almost identical results; the slight differences could be attributed to differences in numerical precision with Microsoft Excel and Visual Basic.NET. RESRAD-RDD version 2.01 allows the selection of different units for use in reporting calculation results. The results of SI units were obtained and compared with the base results (in traditional units) used for comparison with version 1.7. The comparison shows that RESRAD-RDD version 2.01 correctly reports calculation results in the unit specified in the GUI.

54 ENVIRONMENTAL SCIENCES↗