Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Code Robustness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

NucMesh: nuclear reactor geometry creation and mesh generation module in NEMoSys

NucMesh is a parameterized geometry and mesh generator for nuclear reactors developed within the Nuclear Energy Modeling System NEMoSys at Illinois Rocstar. NEMoSys is a platform developed for mesh generation, adaptive refinement, and solution verification. NucMesh is implemented to be generalized and extensible with a robust computer aided design engine and multiple mesh generation algorithms for unstructured triangular, quad-dominant, and structured quadrilateral meshing. In this paper, we present the geometric and meshing features of NucMesh. Geometrically objects are constructed bottom-to-top and overlaps are addressed automatically. A sophisticated object tracking algorithm prevents data from being lost for segmented objects. We discuss the primitive objects of circle and polygons that constitute the module and show how they are used with example inputs. Arrays of primitives and arrays of arrays are utilized to build large assemblies of objects. The concept of saved objects is discussed to demonstrate how repetitive objects can be reused easily and augmented in place. Three dimensional meshes can be obtained through mesh extrusion where all materials and side sets are extended to three dimensions. We show that side sets can be defined nearly anywhere within the geometry and can then be applied to the mesh. Finally, example reactor meshes are demonstrated for the Idaho National Laboratory Advanced Test Reactor and Los Alamos National Lab Empire reactor, both of which use control drums that NucMesh handles easily. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Develop a new integrated macro→micro←nano (MMN) multiscale modeling framework to optimize high strength aluminum alloys and processes for vehicle light-weighting​

Bending tests provide a means to study plane strain fracture performance of 6000 series aluminum alloys. Metrics from bending tests have been correlated with self-pierce riveting (SPR) performance of a high strength AA6111 automotive aluminum alloy in previous works. Using the ORNL HPC resources, this project developed an innovative macro→micro←nano (MMN) multiscale microstructure-based finite element (FE) code to further understanding of the relationship between microstructure and fracture properties of high-strength 6000-series alloys. This work started with microstructural characterization in both mesoscale and nanoscale and bending performance characterization of AA6111 HS2-T6 alloy at Ford, the MMN framework was applied to this alloy to simulate 3-point VDA bending. From the results of the macro-modeling of 3-point VDA bending, the critical region of fracture was identified, and the region geometry was used to construct the micro-model. The fracture criterion of micron-scale precipitates and aluminum matrix which contains submicron and nano particles (AL-SMP-NP) in the micro-model was calibrated and validated by comparing simulated and measured bending results. With the AL-SMP-NP fracture strain obtained, the fracture strain of Al-matrix containing nano particles (ALNP) will similarly be determined by a submicron scale-model using an edge-constrained FE modeling approach developed by Hu et al. With the ALNP fracture strain obtained, the fracture strain of Al-matrix containing no particles will similarly be determined by a nano scale-model using an edge-constrained FE modeling approach. After the MMN framework is built and fracture criterion calibrated, nano-model FE simulations with virtual microstructures was performed to obtain a reduced order model (ROM) of the fracture criterion of the ALNP as a function of volume fraction, size, and distribution of the nanoparticle. This nano→submicron→micro modeling part allows exploration of the influence of different material nanostructures from different process conditions on the bending properties within the multiscale bending simulation framework and the ROM of material bendability as a function of nanoparticle size and shape was established. This obtained reduced order model (ROM) could help guide the design and selection of materials to improve existing SPR process models that could replace trial-and-error rivet/die selection and help to design new rivet/die combinations capable of robustly joining new higher strength 6000 5 series alloys in automotive body structures. This would enable lightweighting of Ford vehicles leading to greater fuel efficiency and reduce manufacturing time and energy.

36 MATERIALS SCIENCE↗

kynema-fmb [SWR-23-07]

Kynema-FMB (FKA: Kynema) is an open-source performance portable flexible multibody (FMB) dynamics solver designed for time-domain simulations. While originally tailored for wind turbine structural dynamics, the formulation and implementation are those of a general flexible-multidbody dynamics solver that can readily be applied to a wide range of systems. Kynema was designed with a narrow focus, namely to provide a lightweight, fast, accurate FMD solver for coupling to computational-fluid-dynamics (CFD) codes, especially the CFD codes in the Kynema suite, for fluid-structure-interaction (FSI) simulations. Kynema-FMB is equipped to model systems that can be represented as a collection of beams and rigid bodies that are connected through constraints. Degrees of freedom are defined in the inertial/global frame of reference and include displacements and rotations (formally as rotation matrices, but stored as quaternions). The underlying formulation is built on a Lie-group time integrator designed for index-3 differential-algebraic equations, which is second-order accurate in time (Bruls et al., 2012). Beam models are based on geometrically exact beam theory and are discretized as high-order spectral finite elements similar to those in BeamDyn (Wang et al., 2017). The governing equations for a FMD system like a wind turbine constitute a highly nonlinear system of constrained partial-differential equations. Kynema-FMB uses analytical Jacobians in the nonlinear-system solves in each time step. Linear systems use sparse storage and several third-party sparse-linear-system solvers are enabled. Ill conditioning of linear systems is mitigated with preconditioning described in Bottasso et al, 2008. Kynema-FMB is integrated with a simple open-source controller (ROSCO). There is an application programming interface (API) for coupling to geometry-resolved CFD (like that in Sharma et al., 2023) and actuator-force CFD (like that in Kuhn et al., 2025). In the latter, for actuator-line models, Kynema-FMB includes an internal blade-element solver that depends on user-provided lookup tables for coefficients of lift and drag, i.e., aerodynamic polars. Kynema-FMB is written in C++ and leverages Kokkos and Kokkos-Kernels (KokkosEcosystem) as its performance portability layer enabling simulations on both CPU and GPU systems. The repository is equipped with extensive automated testing at the unit and regression/system levels. The following describes the high-level development objectives conceived for Kynema: *Kynema will follow modern software development best practices, including test-driven development (TDD), version control, hierarchical automated testing, and continuous integration (CI) for a robust development environment. *The core data structures are memory efficient and enable vectorization and parallelization at multiple levels. *Data structures are data-oriented to exploit methods for accelerated computing including high utilization of chip resources (e.g., single instruction multiple data (SIMD) instruction sets) and parallelization using GP-GPUs. *The computational algorithms incorporate robust open-source libraries for mathematical operations, resource allocation, and data management. *The API design considers multiple stakeholder needs and ensure integration with existing and future ecosystems for data science, machine learning, and AI. *Kynema-FMB is written in modern C++ and leverages Kokkos as its performance-portability library with inspiration from the kynema stack.

Sprague, MichaelA.↗

A future of inertial confinement fusion without laser-plasma instabilities

From the beginning of inertial confinement fusion (ICF) research, laser-plasma instabilities excited by narrowband lasers have limited the hydrodynamic design space of all laser-based approaches to inertial fusion energy (IFE). With advances in broadband laser technologies, the next generation of ICF drivers will likely have large bandwidth that is engineered to mitigate laser-plasma instabilities, thereby expanding the hydrodynamic design space to include both robust high yields (>200−MJ) with large-energy laser systems (>4 MJ) and high gains (>10) with moderate-energy laser facilities (<2 MJ). State-of-the-art simulations indicate that laser bandwidths of a few percent are required to mitigate instabilities for IFE-relevant conditions. To test these models and demonstrate that high-bandwidth lasers mitigate laser-plasma instabilities, the Fourth-generation Laser for Ultrabroadband eXperiments will be used with the OMEGA Laser System. The goal is to provide the community with the confidence to invest in a multiple-beam high-bandwidth laser facility that will demonstrate the necessary ablation pressures for robust direct-drive ignition without detrimental levels of hot electrons that degrade the implosion performance. It is important to recognize that the highest performing ICF implosions will likely never be completely LPI free because of the significant advantages to maximizing the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DYNAMICS OF CIRCUMSTELLAR DISKS. III. THE CASE OF GG Tau A

We present two-dimensional hydrodynamic simulations using the Smoothed Particle Hydrodynamic code, VINE, to model a self-gravitating binary system. We model configurations in which a circumbinary torus+disk surrounds a pair of stars in orbit around each other and a circumstellar disk surrounds each star, similar to that observed for the GG Tau A system. We assume that the disks cool as blackbodies, using rates determined independently at each location in the disk by the time dependent temperature of the photosphere there. We assume heating due to hydrodynamical processes and to radiation from the two stars, using rates approximated from a measure of the radiation intercepted by the disk at its photosphere. We simulate a suite of systems configured with semimajor axes of either a = 62 AU (“wide”) or a = 32 AU (“close”), and with assumed orbital eccentricity of either e = 0 or e = 0.3. Each simulation follows the evolution for ∼6500–7500 yr, corresponding to about three orbits of the torus around the center of mass. Our simulations show that strong, sharply defined spiral structures are generated from the stirring action of the binary and that, in some cases, these structures fragment into 1–2 massive clumps. The torus quickly fragments into several dozen such fragments in configurations in which either the binary is replaced by a single star of equal mass, or radiative heating is neglected. The spiral structures extend inwards to the circumstellar environment as large scale material streams for which most material is found on trajectories that return it to the torus on a timescale of 1–200 yr, with only a small fraction accreting into the circumstellar environment. The spiral structures also propagate outwards through the torus, generating net outwards mass flow, and eventually losing coherence at large distances from the stars. The torus becomes significantly eccentric in shape over most of its evolution. In all configurations, accretion onto the stars occurs at a steady rate of a few ×10{sup −8} M {sub ⊙} yr{sup −1}, with the net result that, without replenishment, the disk lifetimes would be shorter than ∼10{sup 4} yr. Our simulations show that only wide orbit configurations are able to retain circumstellar disks, by virtue of accretion driven from the robust material streams generated in wide configurations, which are very weak in close configurations. In wide, eccentric orbit configurations, accretion is episodic and occurs preferentially onto the secondary, with rates strongly peaked near the binary periapse. Based on our results, we conclude that the GG Tau A torus is strongly self gravitating and that a major contribution to its thermal energy input is the shock dissipation associated with spiral structures generated both by self gravitating disturbances and by the stirring action of the binary. We interpret the sharply defined features observed in the torus as manifestations of such spiral structures. We interpret the low density disk surrounding it as an excretion disk created by the outward mass flux generated by the spiral arms as they propagate outwards. Typical eccentricities calculated for the shape of the tori modeled in our simulations are large enough to account for the supposed ∼20° mutual inclination between the stellar orbit plane of GG Tau A and its surrounding torus through a degeneracy between the interpretation of inclination of the torus and its eccentricity. We therefore interpret the observations in favor of a coplanar system with an eccentric torus. Because accretion onto the disks occurs at rates sufficient to sustain them only in wide orbit configurations, we conclude that the gas currently resident in the circumstellar disks of the GG Tau A system has been accreted from the torus within the past few thousand years. Although circumstellar disks will persist over time spans long enough to permit planet formation, the overall environment remains unfavorable due to high temperatures and other conditions. Given the presence of circumstellar disks, robust accretion streams, and our interpretation of the GG Tau A stellar orbit plane as coplanar with the torus surrounding it, we conclude that the GG Tau A system is in an eccentric, a ∼ 62 AU orbit, resolving questions in the literature regarding its orbit parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Data for: Patel et al. Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data

This dataset contains data and code used for the paper "Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data" [DOI COMING SOON]A large literature exists on mechanisms driving soil production of the greenhouse gases CO2 and CH4. Measurements of these gases’ fluxes are often performed using closed-chamber incubations in the laboratory or in situ, i.e., in the field. Although it is common knowledge that measurements obtained through field studies vs. laboratory incubations can diverge because of the vastly different conditions of these environments, few studies have systematically examined these patterns. It is crucial to understand the magnitude and reasons for any differences, as these data are used to parametrize and benchmark ecosystem- to global-scale models, which are then susceptible to the biases of the source data. Here, we specifically examine how greenhouse gas measurements may be influenced by whether the measurement/incubation was conducted in the field vs. laboratory, focusing on CO2 and CH4 measurements. We use Q10 of greenhouse gas flux (temperature sensitivity) for our analyses, because of the ubiquity of this metric in biological and Earth system sciences and its importance to many modeling frameworks. We predicted that laboratory measurements would be less variable, but also less representative of true field conditions. However, there was greater variability in the Q10 values calculated from lab-based measurements of CO2 fluxes, because lab experiments explore extremes rarely seen in situ, and reflect the physical and chemical disturbances occurring during sampling, transport, and incubation. Overall, respiration Q10 values were significantly greater in laboratory incubations (mean = 4.19) than field measurements (mean = 3.05), with strong influences of incubation temperature and climate region/biome. However, this was in part because field measurements typically represent total respiration (Rs), whereas lab incubations typically represent heterotrophic respiration (Rh), making direct comparisons difficult to interpret. Focusing only on Rh-derived Q10, these values showed almost identical distributions across laboratory (n = 1110) and field (n = 581) experiments, providing strong support for using the former as an experimental proxy for the latter, although we caution that geographic biases in the extant data make this conclusion tentative. Due to a smaller sample size of CH4 Q10 data, we were unable to perform a comparable robust analysis, but we expect similar interactions with soil temperature, moisture, and environmental/climatic variables. Our results here suggest the need for more concerted efforts to document and standardize these data, including sample and site metadata. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/kaizadp/field_lab_q10 (DOI: 10.5281/zenodo.7106554).

54 ENVIRONMENTAL SCIENCES↗

Intensity modulated neutron radiotherapy optimization by photon proxy

Purpose: Introducing intensity modulation into neutron radiotherapy (IMNRT) planning has the potential to mitigate some normal tissue complications seen in past neutron trials. While the hardware to deliver IMNRT plans has been in use for several years, until recently the IMNRT planning process has been cumbersome and of lower fidelity than conventional photon plans. Our in-house planning system used to calculate neutron therapy plans allows beam weight optimization of forward planned segments, but does not provide inverse optimization capabilities. Commercial treatment planning systems provide inverse optimization capabilities, but currently cannot model our neutron beam. Methods: We have developed a methodology and software suite to make use of the robust optimization in our commercial planning system while still using our in-house planning system to calculate final neutron dose distributions. Optimized multileaf collimator (MLC) leaf positions for segments designed in the commercial system using a 4 MV photon proxy beam are translated into static neutron ports that can be represented within our in-house treatment planning system. The true neutron dose distribution is calculated in the in-house system and then exported back through the MATLAB software into the commercial treatment planning system for evaluation. Results: The planning process produces optimized IMNRT plans that reduce dose to normal tissue structures as compared to 3D conformal plans using static MLC apertures. The process involves standard planning techniques using a commercially available treatment planning system, and is not significantly more complex than conventional IMRT planning. Using a photon proxy in a commercial optimization algorithm produces IMNRT plans that are more conformal than those previously designed at our center and take much less time to create. Conclusions: The planning process presented here allows for the optimization of IMNRT plans by a commercial treatment planning optimization algorithm, potentially allowing IMNRT to achieve similar conformality in treatment as photon IMRT. The only remaining requirements for the delivery of very highly modulated neutron treatments are incremental improvements upon already implemented hardware systems that should be readily achievable.

60 APPLIED LIFE SCIENCES↗

Microreactor Optimization Using Simulation And Economics (mouse)

Microreactor Optimization Using Simulation and Economics (MOUSE) is a tool that integrates both nuclear microreactor design and reactor economics to provide comprehensive evaluations and optimizations. This tool enables stakeholders to explore the interplay between technical and economic variables, guiding them towards effective and competitive microreactor solutions. For the reactor core simulations, MOUSE leverages the OpenMC Monte Carlo Particle Transport Code to perform detailed core simulations for various microreactor designs. The included OpenMC models are 2D core designs of a Liquid Metal Thermal Microreactor (LMTR), a Gas-Cooled TRISO-Fueled Microreactor (GCMR), and a Heat Pipe Microreactor. Beyond core design, MOUSE includes simplified calculations for: - Calculating the masses of heat exchangers within the system. - Mechanical power of pumps. - Estimating the area occupied by various buildings within the nuclear plant. For the economic analysis, MOUSE provides detailed bottom-up cost estimates, encompassing a wide range of costs including preconstruction costs, direct costs, indirect costs, training costs, financial costs, operation & maintenance (O&M) costs, and fuel costs. These cost estimations are developed using data from the MARVEL project and additional literature sources, enabling the calculation of total capital costs and levelized cost of energy for both first-of-a-kind and nth-of-a-kind microreactors. MOUSE also enables analysis of the cost drivers and competitiveness in the electricity market. MOUSE allows users to modify a wide array of technical and economic parameters to evaluate different scenarios and their impacts. Examples of these parameters include: Fuels, coolants, or reflector materials Enrichment levels Control drum materials and geometry Fuel pin geometry and materials Moderator pin geometry and materials Reactor core and reflector dimensions Packing factor for the TRISO particles Nuclear reactor power and reactor burnup Number of sensors Shielding thickness Reactor vessel and guard vessel dimensions Operational staff requirements Number of emergency shutdowns Levelization period Interest rate Construction duration Since MOUSE is powered by the WATTS toolkit, it supports optimization studies, parametric analyses, and uncertainty calculations/propagation. The optimization techniques enable users to identify optimal design and economic configurations. The parametric analysis tools allow users to explore the sensitivity of various parameters, while uncertainty propagation helps quantify the impact of uncertainties on overall performance and cost. User Interface and Workflow: Currently, MOUSE is a command-line-based tool. Users can input various reactor design or economic parameters, modify the designs, run simulations, and visualize results through comprehensive data visualization and reporting capabilities. The typical workflow involves setting up the reactor model, defining economic parameters, running simulations, and analyzing the results to make informed decisions. By combining advanced design calculations with detailed economic modeling, MOUSE provides a robust framework for optimizing nuclear microreactor technologies, enhancing their competitiveness, and guiding stakeholders towards innovative and cost-effective solutions.

Hanna, Botros [Idaho National Laboratory (INL), Id↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

SU-E-T-136: Dosimetric Robustness of a Magnetic Resonance Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the radiation delivery robustness of the first MR-IGRT system using a commercial cylindrical diode array detector (ArcCHECK) and an ionization thimble chamber (Exradin A18). Methods: The MR-IGRT system is composed of three evenly spaced Co-60 sources on a rotating gantry located between two magnet halves. The collimator for each source consists of 30 doubly-focused leaf pairs that allow the system to deliver both conformal and intensity modulated (IMRT) treatment plans. The system's delivery robustness was tested over a span of 6 months from September 2013 through February 2014. This was achieved by repeatedly delivering 10 patient plans. These plans consisted of 2 conformal prostates, 2 IMRT prostates, 2 IMRT head and neck, 2 IMRT breast, 1 IMRT pancreas, and 1 IMRT bladder. The plans were generated with the system's treatment planning software. Once the plans were generated, quality assurance plans were created on a digital ArcCHECK dataset. The ArcCHECK used for testing was specially designed to be MR-compatible by moving the power supply outside of the magnetic field. The A18 ionization chamber was placed in a custom plastic plug insert in the center of the ArcCHECK. Gamma analysis was used with the ArcCHECK for relative dose evaluating both 3%/3mm and 2%/2mm. Absolute point dose was compared between ion chamber measurement and treatment plan. Results: The ArcCHECK passing rate remained constant over the 6 month period. The average passing rate for 3%/3mm and 2%/2mm analysis was 98.6% ± 0.7 and 88.8% ± 2.9, respectively. The ion chamber measurements showed little variation with an average percent difference between planned dose verses measured dose of 0.9% ± 0.7. Conclusion: Minimal differences were noted in the delivery of the 10 patient plans. Over a period that included acceptance testing, commissioning, and clinical deliveries, the MR-IGRT system remained consistent in radiation delivery.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-01: Development of An Image-Guided Dosimetric Planning System for Injectable Brachytherapy Using ELP Nanoparticles

Purpose: To develop, validate, and evaluate a methodology for determining dosimetry for intratumoral injections of elastin-like-polypeptide (ELP) brachytherapy nanoparticles. These organic-polymer-based nanoparticles are injectable, biodegradable, and genetically tunable. We present a genetically encoded polymer-solution, composed of novel radiolabeled-ELP nanoparticles that are custom-designed to self-assemble into a local source upon intratumoral injection. Our preliminary results of a small animal study demonstrate 100% tumor response, effective radionuclide retention-rates, strong in vivo stability, and no polymer-induced toxicities. While our approach is therefore highly promising for improved brachytherapy, the current workflow lacks a dosimetry framework. Methods: We are developing a robust software framework that provides image-guided dosimetric-planning capabilities for ELP brachytherapy. The user graphically places ELP injection sites within a µCT-planning-image, and independently defines each injection volume, concentration, and radioisotope to be used. The resulting internal dosimetry is then pre-determined by first modeling post-injection ELP advection-diffusion, and then calculating the resulting dose distribution based on a point- dose-kernel-convolution algorithm. We have experimentally measured ELP steady-state concentrations via µSPECT acquisition, and validated our dose calculation algorithm against Monte Carlo simulations of several radioactivity distributions. Finally, we have investigated potential advantages and limitations of various ELP injection parameters. Results: The µSPECT results demonstrated inhomogeneous steady-state distributions of ELP in tissue, and Monte Carlo radioactivity distributions were designed accordingly. Our algorithm yielded a root-mean-square-error of less than 2% for each distribution tested (average root-mean-square-error was 0.73%). Dose-Volume-Histogram analysis of five different plans showed how strategic injection placement, and an injection volume-tapering technique, could be used to achieve D95% target coverage. Conclusion: We have preliminarily developed a novel planning framework for ELP brachytherapy. Its dosimetry accuracy has been validated against Monte Carlo, and we have started to investigate the potential advantages of injection-based planning. This system, once fully developed, will serve as the technical foundation for our novel approach.

60 APPLIED LIFE SCIENCES↗

Scaling Input Distributions for Probabilistic Models - 19472

It is important to address scaling issues when building models to support risk-based decisions for radioactive waste disposal sites. Currently, probabilistic risk assessment and probabilistic performance assessment models are run for multiple realizations where each realization uses one value from each input distribution over the entire modeled time. The input distributions represent the current state of knowledge in the mean of the input variable over the spatial region of interest and over the time period of the model run. This paper focuses on the time factor in input distribution scaling because it presents more serious conceptual and distributional challenges than the spatial factor. One of the challenges in temporal scaling is the effect of non-linearity on propagation of distribution uncertainty through to uncertainty in results. Radioactive waste disposal models tend to have both linear and non-linear components in their models. Dose assessment calculations are typically represented by linear models, while contaminant transport models have linear and non-linear components. In principle, temporal scaling of input parameter distributions for a linear model is straightforward, but scaling of input distributions for non-linear models is not. This paper uses examples to investigate the effects of input distribution temporal scaling on simple linear and non-linear models. Different scaling scenarios were investigated by comparing three analysis tools: analytical mathematical representations, statistical software programming, and GoldSim Monte Carlo simulation software. R statistical software is an open source statistical programming language often used for statistical analyses and graphical representation of data. GoldSim is a robust probabilistic dynamic modeling platform used in performance assessment modeling of radioactive waste sites. A simple linear model, a quadratic model and a multiplicative model were the cases explored for each of these tools. For the three analysis tools considered and with each of the scaling cases, 1,000 realizations were implemented from distributions of the random variables of interest. This is a sufficient number of realizations for simple models to capture the model space. An annual temporal resolution of a 100-year simulation period was chosen for all models and analysis tools. The effects of temporal scaling were demonstrated by investigating two different options for time scaling. Option 1 was set up so that the input distributions represented the expected value on an annual time scale, and a new value from that distribution was chosen every year (at every time step which equaled a year) for 100 years. In Option 2, the input distributions were scaled to represent the expected mean value of the input variable over the 100 years of simulation, and one value from that distribution was chosen for the entire elapsed time. Results show agreement across the three analysis tools. As expected, the linear models have identical results for the two different scaling Options, and the non-linear models diverge in the results for different time scale implementation. The implications of this work point to the need for careful consideration of input distribution temporal scaling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-PIS-Exhibit Hall-5: Use of the Enterprise-wide Dose Tracking Software Radimetrics In an Academic Medical System

The current clinical standard of organ respiratory imaging, 4D-CT, is fundamentally limited by poor soft-tissue contrast and imaging dose. These limitations are potential barriers to beneficial “4D” radiotherapy methods which optimize the target and OAR dose-volume considering breathing motion but rely on a robust motion characterization. Conversely, MRI imparts no known radiation risk and has excellent soft-tissue contrast. MRI-based motion management is therefore highly desirable and holds great promise to improve radiotherapy of moving cancers, particularly in the abdomen. Over the past decade, MRI techniques have improved significantly, making MR-based motion management clinically feasible. For example, cine MRI has high temporal resolution up to 10 f/s and has been used to track and/or characterize tumor motion, study correlation between external and internal motions. New MR technologies, such as 4D-MRI and MRI hybrid treatment machines (i.e. MR-linac or MR-Co60), have been recently developed. These technologies can lead to more accurate target volume determination and more precise radiation dose delivery via direct tumor gating or tracking. Despite all these promises, great challenges exist and the achievable clinical benefit of MRI-based tumor motion management has yet to be fully explored, much less realized. In this proposal, we will review novel MR-based motion management methods and technologies, the state-of-the-art concerning MRI development and clinical application and the barriers to more widespread adoption. Learning Objectives: Discuss the need of MR-based motion management for improving patient care in radiotherapy. Understand MR techniques for motion imaging and tumor motion characterization. Understand the current state of the art and future steps for clinical integration. Henry Ford Health System holds research agreements with Philips Healthcare. Research sponsored in part by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

Verification of the DIF3D Software to Support Fast Reactor Analysis

Ongoing design activities at Argonne National Laboratory are requiring a thorough verification of the Argonne Reactor Computation codes be performed. DIF3D is central to this system. The driver for this effort requires the 3D Cartesian, triangular-Z, and hexagonal-Z core geometry options of DIF3D be verified. Previous work identified the DIF3D features required to be verified to support current design activities, features of which are generally applicable to hexagonal-Z fast reactor designs. The scope of this verification effort includes verifying DIF3D’s ability to correctly translate the user’s model in to DIF3D’s preferred format, verifying that options planned for use have the desired effect, and verifying the correctness of the eigenvalue, fixed-source, forward, and adjoint solvers in DIF3D-FD and DIF3D-VARIANT. This manuscript provides the verification tasks and their results with respect to the features needed for current design activities. Since analytic solutions of the neutron diffusion and transport equations are either limited in scope or not possible, multiple tiers of problems unique to each solver and geometry type were implemented. Each of these tiers tests features independent and complementary arguments for why the separate testing of functionalities is acceptable. Finally, this separate testing was also supplemented with a high-level integral check of each the diffusion and transport capabilities and applicable geometries. To accommodate cases which an analytic solution is not feasible, MCNP6.2 was relied upon to provide a higher-order reference solution. This therefore required that the capabilities within MCNP6.2 which were relied upon for this work are also verified in this work. No MCNP discrepancies were noted in this effort. Note that the MCNP6.2 verification included in this work does not stand as a full verification of MCNP6.2, but merely verifies the features used in verifying DIF3D. The verification effort identified no issues that are debilitating or otherwise impactful to design usage of DIF3D, and thus DIF3D version 11.0, release 3012 is considered verified. The types of issues that were identified were predominantly in the areas of: unclear documentation, software bugs which were inconsequential to final results, editing options which were ignored in favor of printing more information than requested, bugs in the outputs of intermediate results, or secondary output binary file information which was not present. While not a bug, this verification report also identified that the algorithm used to evaluate the peak fast flux in a nodal transport solution can be quite unreliable due to the polynomial order used and the location of the peak within the mesh. The authors of the report therefore recommend the usage of the EvaluateFlux software (distributed with ARC) as a more robust alternative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

Advanced Simulation Capability for Environmental Management - Current Status and Phase II Demonstration Results - 13161

The U.S. Department of Energy (US DOE) Office of Environmental Management (EM), Office of Soil and Groundwater, is supporting development of the Advanced Simulation Capability for Environmental Management (ASCEM). ASCEM is a state-of-the-art scientific tool and approach for understanding and predicting contaminant fate and transport in natural and engineered systems. The modular and open source high-performance computing tool facilitates integrated approaches to modeling and site characterization that enable robust and standardized assessments of performance and risk for EM cleanup and closure activities. The ASCEM project continues to make significant progress in development of computer software capabilities with an emphasis on integration of capabilities in FY12. Capability development is occurring for both the Platform and Integrated Tool-sets and High-Performance Computing (HPC) Multi-process Simulator. The Platform capabilities provide the user interface and tools for end-to-end model development, starting with definition of the conceptual model, management of data for model input, model calibration and uncertainty analysis, and processing of model output, including visualization. The HPC capabilities target increased functionality of process model representations, tool-sets for interaction with Platform, and verification and model confidence testing. The Platform and HPC capabilities are being tested and evaluated for EM applications in a set of demonstrations as part of Site Applications Thrust Area activities. The Phase I demonstration focusing on individual capabilities of the initial tool-sets was completed in 2010. The Phase II demonstration completed in 2012 focused on showcasing integrated ASCEM capabilities. For Phase II, the Hanford Site deep vadose zone (BC Cribs) served as an application site for an end-to-end demonstration of capabilities, with emphasis on integration and linkages between the Platform and HPC components. Other demonstrations, addressing attenuation-based remedies at the Savannah River Site F Area and performance assessment for a representative waste tank, illustrate integration of linked ASCEM capabilities and initial integration efforts with tools from the Cementitious Barriers Partnership. (authors)

54 ENVIRONMENTAL SCIENCES↗

PRIMA-X - Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing

The PRIMA-X (Performance Retargeting of Instrumentation, Measurement, and Analysis Technologies for Exascale Computing) project is the successor of the DOE PRIMA (Performance Refactoring of Instrumentation, Measurement, and Analysis Technologies for Petascale Computing) project, which addressed the challenge of creating a core measurement infrastructure that would serve as a common platform for both integrating leading parallel performance systems (notably TAU and Scalasca) and developing next-generation scalable performance tools. The PRIMA-X project shifts the focus away from refactorization of robust performance tools towards a re-targeting of the parallel performance measurement and analysis architecture for extreme scales. The massive concurrency, asynchronous execution dynamics, hardware heterogeneity, and multi-objective prerequisites (performance, power, resilience) that identify exascale systems introduce fundamental constraints on the ability to carry forward existing performance methodologies. In particular, there must be a deemphasis of per-thread observation techniques to significantly reduce the otherwise unsustainable flood of redundant performance data. Instead, it will be necessary to assimilate multi-level resource observations into macroscopic performance views, from which resilient performance metrics can be attributed to the computational features of the application. This requires a scalable framework for node-level and system-wide monitoring and runtime analyses of dynamic performance information. Also, the interest in optimizing parallelism parameters with respect to performance and energy drives the integration of tool capabilities in the exascale environment further. Initially, PRIMA-X was a collaborative project between the University of Oregon (lead institution) and the German Research School for Simulation Sciences (GRS). Because Prof. Wolf, the PI at GRS, accepted a position as full professor at Technische Universitaet Darmstadt (TU Darmstadt) starting February 1st, 2015, the work of GRS was continued at TU Darmstadt. This report covers the work at TU Darmstadt after the transition. The first main accomplishment of TU Darmstadt is the development of different techniques to aggregate performance data on the level of threads. TU Darmstadt evaluated different schemes designed at GRS during the first phase of this project and integrated them into Score-P, a widely used performance measurement framework for HPC applications. The second main accomplishment is a substantial increase of Score-P’s scalability, achieved by improving its internal representation of the underlying system. Third, we extended our performance-modeling tool Extra-P to automatically create models with more than one input parameter (e.g., process count and input size), which was previously impossible. These models allow the performance behavior of an application to be extrapolated to larger machines. Specific applications of the new multi-parameter capability realized in this project include modeling the isoefficiency function of task-based applications and a novel co-design methodology. Further extensions of Extra-P comprise online modeling functionality, automatic refinement of the model search space, and segmented performance modeling. Further contributions include new locality metrics for both shared- and distributed-memory applications, a new way of measuring the impact of inter-application inference on the execution time of an application, and finally an automatic method that selects appropriate OpenMP constructs for the parallelization of sequential code and classifies the affected variables based on their sharing semantics.

97 MATHEMATICS AND COMPUTING↗