Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Compact collimated fiber optic array diagnostic for railgun plasmas

We developed and tested a compact collimated 16 channel fiber optic array diagnostic for studying the light emission of railgun armature plasmas with approximately millimeter spatial and submicrosecond temporal resolution. The design and operational details of the diagnostic are described. Plasma velocities, oscillation, and dimension data from the diagnostic for the Livermore fixed hybrid armature experiment are presented and compared with one-dimensional simulations. The techniques and principles discussed allow the extension of the diagnostic to other railgun and related dense plasma experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Compact Disk Type Plasma Propulsion System with Modulated Magnetic Field for Nanoscale Space Vehicles

A compact 5 mm disk type plasma thruster simply composed of only a set of antenna windings and bias field coil which produces significant thrust of 0.74 mN with rotating magnetic field has been proposed and successfully developed for future applications to low altitude nanosatellites. The key technology issue is that the rotating speed is set above the ion plasma frequency but far below the electron plasma frequency, in order to produce the electron drag current and axial electric field as a consequence of the interaction with the bias field. The formation of axial electric field was confirmed and the produced plasma density was >6x10{sup 18} m{sup -3}, whereas the power consumption is 500 W in the inductively coupled mode of operation. The anticipated thrust density and specific thrust could potentially be extended to 7.64 Nm{sup -2} and 850 s, respectively, which is comparable to conventional Hall effect thrusters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a compact electron ion coincidence analyzer using a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes

A compact electron ion coincidence (EICO) analyzer that uses a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes was developed for surface science and surface analysis. The apparatus is especially useful in the study of ion desorption stimulated by an Auger process because information on the mass, yield, desorption polar angle, and kinetic energy of ions can be obtained for the selected core-ionization-final-states or the selected Auger-final-states. The analyzer can be used also for analysis of the configuration of specific surface molecules because the desorption polar angles reflect the direction of surface bonds. The EICO analyzer was evaluated by measuring polar-angle-resolved-ion yield spectra and coincidence spectra of Auger-electron and polar-angle-resolved H{sup +} from condensed water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 2.8 K cryogen-free cryostat with compact optical geometry for multiple photon counting

Interest in solid scintillators down to liquid helium temperature and below has grown recently, fuelled by searches for exotic processes in particle physics. We describe a closed-cycle optical cryostat with a 2.8 K base temperature and a compact optical geometry for multiple photon counting. The large numerical aperture achieved, of the order of 0.79 from the optical center to each of the two windows and amounting to 40% of the total solid angle, allows a significant gain in the efficiency of photon collection. This and the relatively big sample size that can be used facilitate the study of scintillators under {gamma} irradiation. These features should be an asset for multiple photon counting techniques at low temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the Development of Humanitarian Landmine Detection System by a Compact Fusion Neutron Source and Dual Sensors

A 5-year task is described on the research and development of the advanced humanitarian landmine detection system by using a compact discharge-type fusion neutron source called IECF (Inertial-Electrostatic Confinement Fusion) device and 3 dual sensors made of BGO and NaI(Tl). With 10{sup 7} D-D neutrons/s stably produced in steady-state mode, H-2.2 MeV, N-5.3, 10.8 MeV {gamma} rays from (n,{gamma}) reaction with hydrogen and nitrogen atoms in the explosives are measured for two kinds of explosives (TNT, RDX), under the conditions of three different buried depths, and soil moistures each. Final probabilities of detection for arid soil are found to be 100% in the present tests. The neutron backscattering method is also found to be efficient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact LaBr{sub 3}: Ce Gamma Ray Detector with Si-APD Readout

BrilLanCe 380 (LaBr{sub 3}:Ce) crystal scintillators available from Saint-Gobain Crystals have achieved 2.6% FWHM for 662 keV photons. This is accomplished with PMT light sensors. Attempts to have similarly good results with PIN photo-diodes and APDs have not been successful. PIN photodiodes do not have any gain and the signal to noise ratio is poor at room temperature. Similarly, even though APDs have sufficient gain, they have poor signal to noise at room temperature. Recently there have been improvements in APDs decreasing the internal noise and increasing their sensitivity, making them an excellent light sensor. With the improved APD, it is now possible to achieve performance with a solid state light sensor comparable to that of PMTs. We have measured 2.8% for 662 keV gamma rays at room temperature using an APD for a light sensor on a 20 mm long crystal of 1.6 cc volume. APDs have advantages of compactness, inherent ruggedness and minimal sensitivity to magnetic fields. Such a device is very practical for hand held and portable field measurement applications. (Performance reported in SGC literature.)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact microwave re-entrant cavity applicator for plasma-assisted combustion

The design and experimental operation of a compact microwave/rf applicator is described. This applicator operates at atmospheric pressure and couples electromagnetic energy into a premixed CH{sub 4}/O{sub 2} flame. The addition of only 2-15 W of microwave power to a premixed combustion flame with a flame power of 10-40 W serves to extend the flammability limits for fuel lean conditions, increases the flame length and intensity, and increases the number density and mixture of excited radical species in the flame vicinity. The downstream gas temperature also increases. Optical emission spectroscopy measurements show gas rotational temperatures in the range of 2500-3600 K. At the higher input power of {>=}10 W microplasma discharges can be produced in the high electric field region of the applicator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Physics for Compact Stars

A brief overview is given of the different lines of research developed under the INFN project 'Compact Stellar Objects and Dense Hadronic Matter' (acronym CT51). The emphasis of the project is on the structure of Neutron Stars (NS) and related objects. Starting from crust, the different Nuclear Physics problems are described which are encountered going inside a NS down to its inner core. The theoretical challenges and the observational inputs are discussed in some detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

General relativistic compact stars with exotic matter

We study the structures of general relativistic compact stars with exotic matter. Our study is based on axisymetric and stationary formalism including purely toroidal magnetic field. We also study the finite size effects of quark-hadron mixed phase on the structures of magnetars. For hybrid stars, we find the characteristic distribution of magnetic field, which has a discontinuity originated in the quark-hadron mixed phase. These distributions of magnetic field will change astrophysical phenomena, such as cooling processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact surface decontamination system for surface-sensitive magnetic imaging

A surface decontamination system for application in surface sensitive magnetic imaging tools, such as a spin-polarized scanning electron microscope, is described. Adsorbed contaminant is chemically decomposed with the use of active oxygen in a compact vacuum chamber mounted in a microscope. The present method is especially suitable for fragile magnetic surfaces of complex oxide materials to which the conventional physical etching widely used for magnetic metals could cause serious structural damage. We have succeeded in detecting magnetic signals from a decontaminated oxide surface and visualizing domain images with sufficient magnetic contrast to analyze detailed domain structures.

36 MATERIALS SCIENCE↗

Laser-driven electron beam acceleration and future application to compact light sources

Laser-driven plasma accelerators are gaining much attention by the advanced accelerator community due to the potential these accelerators hold in miniaturizing future high-energy and medium-energy machines. In the laser wakefield accelerator (LWFA), the ponderomotive force of an ultrashort high intensity laser pulse excites a longitudinal plasma wave or bubble. Due to huge charge separation, electric fields created in the plasma bubble can be several orders of magnitude higher than those available in conventional microwave and RF-based accelerator facilities which are limited (up to approx100 MV/m) by material breakdown. Therefore, if an electron bunch is injected into the bubble in phase with its field, it will gain relativistic energies within an extremely short distance. Here, in the LWFA we show the generation of high-quality and high-energy electron beams up to the GeV-class within a few millimeters of gas-jet plasmas irradiated by tens of terawatt ultrashort laser pulses. Thus we realize approximately four orders of magnitude acceleration gradients higher than available by conventional technology. As a practical application of the stable high-energy electron beam generation, we are planning on injecting the electron beams into a few-meters long conventional undulator in order to realize compact X-ray synchrotron (immediate) and FEL (future) light sources. Stable laser-driven electron beam and radiation devices will surely open a new era in science, medicine and technology and will benefit a larger number of users in those fields.

43 PARTICLE ACCELERATORS↗

A compact molecular beam machine

We have developed a compact, low cost, modular, crossed molecular beam machine. The new apparatus utilizes several technological advancements in molecular beams valves, ion detection, and vacuum pumping to reduce the size, cost, and complexity of a molecular beam apparatus. We apply these simplifications to construct a linear molecular beam machine as well as a crossed-atomic and molecular beam machine. The new apparatus measures almost 50 cm in length, with a total laboratory footprint less than 0.25 m{sup 2} for the crossed-atomic and molecular beam machine. We demonstrate the performance of the apparatus by measuring the rotational temperature of nitric oxide from three common molecular beam valves and by observing collisional energy transfer in nitric oxide from a collision with argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation of stable Alfven eigenmodes by application of alternating magnetic field perturbations in the Compact Helical System

Stable toroidicity-induced Alfven eigenmodes (TAEs) with low toroidal mode number (n=1 and n=2) were excited by application of alternating magnetic field perturbations generated with a set of electrodes inserted into the edge region of neutral beam injection heated plasmas on the Compact Helical System [K. Nishimura, K. Matsuoka, M. Fujiwara et al., Fusion Technol. 17, 86 (1990)]. The gap locations of TAEs excited by the electrodes are in the plasma peripheral region of {rho}>0.7 ({rho} is the normalized minor radius) where energetic ion drive is negligibly small, while some AEs are excited by energetic ions in the plasma core region of {rho}<0.4. The damping rate of these stable TAEs derived from plasma responses to applied perturbations is fairly large, that is, {approx}9% to {approx}12% of the angular eigenfrequency. This large damping rate is thought to be dominantly caused by continuum damping and radiative damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact shell solitons in K field theories

Some models providing shell-shaped static solutions with compact support (compactons) in 3+1 and 4+1 dimensions are introduced, and the corresponding exact solutions are calculated analytically. These solutions turn out to be topological solitons and may be classified as maps S{sup 3}{yields}S{sup 3} and suspended Hopf maps, respectively. The Lagrangian of these models is given by a scalar field with a nonstandard kinetic term (K field) coupled to a pure Skyrme term restricted to S{sup 2}, rised to the appropriate power to avoid the Derrick scaling argument. Further, the existence of infinitely many exact shell solitons is explained using the generalized integrability approach. Finally, similar models allowing for nontopological compactons of the ball type in 3+1 dimensions are briefly discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tandem-based compact dual-energy gamma generator

A dual-energy tandem-type gamma generator has been developed at E. O. Lawrence Berkeley National Laboratory and Sandia National Laboratories. The tandem accelerator geometry allows higher energy nuclear reactions to be reached, thereby allowing more flexible generation of MeV-energy gammas for active interrogation applications. Both positively charged ions and atoms of hydrogen are created from negative ions via a gas stripper. In this paper, we show first results of the working tandem-based gamma generator and that a gas stripper can be utilized in a compact source design. Preliminary results of monoenergetic gamma production are shown.

43 PARTICLE ACCELERATORS↗

Electron density measurements of a field-reversed configuration plasma using a novel compact ultrastable second-harmonic interferometer

A compact high-sensitivity second-harmonic interferometer for line-integrated electron density measurements on a large plasma machine is presented. The device is based on a fiber coupled near-infrared continuous-wave Nd:YAG laser and is remotely controlled. The performances of the instrument are tested on the Irvine field-reversed configuration machine, and a sensitivity of few 10{sup 14} cm{sup -2} in measuring line integrated electron density is demonstrated with a time resolution of a few microseconds. The interferometer is self calibrated, has an impressive stability, and it does not require any further alignment after proper installation. These features make this device a real turn-key system suitable for electron density measurement in large plasma machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose Compact Spectrometric Unit

A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage, Real Time Clock and several voltage regulators providing the power for user peripherals (e.g. amplifier, temperature sensors, etc.). Spectrometer is connected with a notebook via high-speed USB 2.0 bus. The spectrometer is multipurpose device, which is planned to be used for measurements of Rn activities, energy of detected particles by CdTe pixel detector or for coincidence measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a compact, permanent magnet electron cyclotron resonance ion source for proton and H{sub 2}{sup +} beam production

A 2.45 GHz microwave ion source was developed at China Institute of Atomic Energy (CIAE) for proton beam production of over 60 mA [B.-Q. Cui, Y.-W. Bao, L.-Q. Li, W.-S. Jiang, and R.-W. Wang, Proceedings of the High Current Electron Cyclotron Resonance (ECR) Ion Source for Proton Accelerator, APAC-2001, 2001 (unpublished)]. For various proton beam applications, another 2.45 GHz microwave ion source with a compact structure is designed and will be built at CIAE as well for high current proton beam production. It is also considered to be used for the test of H{sub 2}{sup +} beam, which could be injected into the central region model cyclotron at CIAE, and accelerated to 5 MeV before extraction by stripping. The required ECR magnetic field is supplied by all the permanent magnets rather than electrical solenoids and six poles. The magnetic field distribution provided by this permanent magnets configuration is a large and uniformly volume of ECR zone, with central magnetic field of a magnitude of {approx}875 Gs[T. Taylor and J. S. C. Wills, Nucl. Instrum. Methods Phys. Res. A 309, 37 (1991)]. The field adjustment at the extraction end can be implemented by moving the position of the magnet blocks. The results of plasma, coupling with 2.45 GHz microwave in the ECR zone inside the ion source are simulated by particle-in-cell code to optimize the density by adjusting the magnetic field distribution. The design configuration of the ion source will be summarized in the paper.

43 PARTICLE ACCELERATORS↗