Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Multiplexed photoionization mass spectrometry investigation of the O( 3 P) + propyne reaction

Here, the reaction of O( 3 P) + propyne (C 3 H 4 ) was investigated at 298 K and 4 Torr using time-resolved multiplexed photoionization mass spectrometry and a synchrotron-generated tunable vacuum ultraviolet light source. The time-resolved mass spectra of the observed products suggest five major channels under our conditions: C 2 H 3 + HCO, CH 3 + HCCO, H + CH 3 CCO, C 2 H 4 + CO, and C 2 H 2 + H 2 + CO. The relative branching ratios for these channels were found to be 1.00, (0.35 ± 0.11), (0.18 ± 0.10), (0.73 ± 0.27), and (1.31 ± 0.62). In addition, we observed signals consistent with minor production of C 3 H 3 + OH and H 2 + CH 2 CCO, although we cannot conclusively assign them as direct product channels from O( 3 P) + propyne. The direct abstraction mechanism plays only a minor role (≤1%), and we estimate that O( 3 P) addition to the central carbon of propyne accounts for 10% of products, with addition to the terminal carbon accounting for the remaining 89%. The isotopologues observed in experiments using d1-propyne (CH 3 CCD) and analysis of product branching in light of previously computed stationary points on the singlet and triplet potential energy surfaces (PESs) relevant to O( 3 P) + propyne suggest that, under our conditions, (84 ± 14)% of the observed product channels from O( 3 P) + propyne result from intersystem crossing from the initial triplet PES to the lower-lying singlet PES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of the human gut microbiome in inflammatory bowel disease

Inflammatory bowel disease (IBD) is characterized by flares of inflammation with periodic need for increased medication and sometimes even surgery. IBD etiology is partly attributed to a deregulated immune response to gut microbiome dysbiosis. Cross-sectional studies have revealed microbial signatures for different IBD diseases, including ulcerative colitis (UC), colonic Crohn’s Disease (CCD), and ileal CD (ICD). Although IBD is dynamic, microbiome studies have primarily focused on single timepoints or few individuals. Here we dissect the long-term dynamic behavior of the gut microbiome in IBD and differentiate this from normal variation. Microbiomes of IBD subjects fluctuate more than healthy individuals, based on deviation from a newly-defined healthy plane (HP). ICD subjects deviated most from the HP, especially subjects with surgical resection. Intriguingly, the microbiomes of some IBD subjects periodically visited the HP then deviated away from it. Inflammation was not directly correlated with distance to the healthy plane, but there was some correlation between observed dramatic fluctuations in the gut microbiome and intensified medication due to a flare of the disease. These results help guide therapies that will re-direct the gut microbiome towards a healthy state and maintain remission in IBD.

gut, human↗

Deep learning with plasma plume image sequences for anomaly detection and prediction of growth kinetics during pulsed laser deposition

Abstract Materials synthesis platforms that are designed for autonomous experimentation are capable of collecting multimodal diagnostic data that can be utilized for feedback to optimize material properties. Pulsed laser deposition (PLD) is emerging as a viable autonomous synthesis tool, and so the need arises to develop machine learning (ML) techniques that are capable of extracting information from in situ diagnostics. Here, we demonstrate that intensified-CCD image sequences of the plasma plume generated during PLD can be used for anomaly detection and the prediction of thin film growth kinetics. We develop multi-output (2 + 1)D convolutional neural network regression models that extract deep features from plume dynamics that not only correlate with the measured chamber pressure and incident laser energy, but more importantly, predict parameters of an auto-catalytic film growth model derived from in situ laser reflectivity experiments. Our results demonstrate how ML with in situ plume diagnostics data in PLD can be utilized to maintain deposition conditions in an optimal regime. Further, the predictive capabilities of plume dynamics on the kinetics of film growth or other film properties prior to deposition provides a means for rapid pre-screening of growth conditions for the non-expert, which promises to accelerate materials optimization with PLD.

36 MATERIALS SCIENCE↗

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

Closed bipolar electrode-enabled dual-cell electrochromic detectors for chemical sensing

Bipolar electrodes (BPE) are electrically floating metallic elements placed in electrified fluids that enable the coupling of anodic and cathodic redox reactions at the opposite ends by electron transfer through the electrode. One particularly compelling application allows electron transfer reactions at one end of a closed BPE to be read out optically by inducing a redox-initiated change in the optical response function of a reporter system at the other end. Here, a BPE-enabled method for electrochemical sensing based on the electrochromic response of a methyl viologen (MV) reporter is developed, characterized, and rendered in a field-deployable format. BPE-enabled devices based on two thin-layer-cells of ITO and Pt were fabricated to couple an analytical reaction in one cell with an MV reporter reaction, producing a color change in the complementary cell. Using Fe(CN) 6 3/4- as a model analyte, the electrochemically induced color change of MV was determined initially by measuring its absorbance via a CCD camera coupled to a microscope. Then, smartphone-based detection and RGB analysis were employed to further simplify the sensing scheme. In both methods a linear relationship between the analyte concentration was produced, the quantity of MV generated, and the colorimetric response, yielding a limit of detection of 1.0 μM. Similar responses were also observed in the detection of dopamine and acetaminophen. Further evolution of the device replaced the potentiostat with batteries to control potential, demonstrating the simplicity and portability of the device. Finally, the physical separation of the reporter and analytical cells renders the device competent to detect analytes in different (e.g. non-aqueous) phases, as demonstrated by using the electrochromic behavior of aqueous MV to detect ferrocene in acetonitrile in the analytical cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A combined experimental and computational study on the reaction dynamics of the 1-propynyl radical (CH 3 CC; X 2 A 1 ) with ethylene (H 2 CCH 2 ; X 1 A 1g ) and the formation of 1-penten-3-yne (CH 2 CHCCCH 3 ; X 1 A')

The crossed molecular beam reactions of the 1-propynyl radical (CH 3 CC; X 2 A 1 ) with ethylene (H 2 CCH 2 ; X 1 A 1g ) and ethylene-d4 (D 2 CCD 2 ; X 1 A 1g ) were performed at collision energies of 31 kJ mol ₋1 under single collision conditions. Combining our laboratory data with ab initio electronic structure and statistical Rice–Ramsperger–Kassel–Marcus (RRKM) calculations, we reveal in this work that the reaction is initiated by the barrierless addition of the 1-propynyl radical to the π-electron density of the unsaturated hydrocarbon of ethylene leading to a doublet C 5 H 7 intermediate(s) with a life time(s) longer than the rotation period(s). The reaction eventually produces 1-penten-3-yne ( p1 ) plus a hydrogen atom with an overall reaction exoergicity of 111 ± 16 kJ mol ₋1 . About 35% of p1 originates from the initial collision complex followed by C–H bond rupture via a tight exit transition state located 22 kJ mol ₋1 above the separated products. The collision complex ( i1 ) can also undergo a [1,2] hydrogen atom shift to the CH 3 CHCCCH 3 intermediate (i2) prior to a hydrogen atom release; RRKM calculations suggest that this pathway contributes to about 65% of p1 . In higher density environments such as in combustion flames and circumstellar envelopes of carbon stars close to the central star, 1-penten-3-yne ( p1 ) may eventually form the cyclopentadiene (c-C 5 H 6 ) isomer via hydrogen atom assisted isomerization followed by hydrogen abstraction to the cyclopentadienyl radical (c-C 5 H 5 ) as an important pathway to key precursors to polycyclic aromatic hydrocarbons (PAHs) and to carbonaceous nanoparticles.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sulfide glass solid-state electrolyte separators for Li metal batteries: using an interlayer to increase rate performance and reduce stack pressure

We report on the solubility of (Li 2 S) 60 (SiS 2 ) x (P 2 S 5 ) 40–x , (0 ≤ x ≤ 40) sulfide glass solid-state electrolytes in the 1:1 (v/v) DME:DOL solvent mixture, a popular choice for lithium metal battery liquid electrolytes. SiS 2 -rich glasses within the compositional range of (Li 2 S) 60 (SiS 2 ) x (P 2 S 5 ) 40–x (28 ≤ x ≤ 40) were found to be functionally insoluble in DME:DOL. Hybrid symmetric test cells with a thin liquid electrolyte layer (0.6 M LiTFSI + 0.4 M LiNO 3 in 1:1 (v/v) DME:DOL) at the interface between lithium metal electrodes and an insoluble (Li 2 S) 60 (SiS 2 ) 28 (P 2 S 5 ) 12 glass wafer were tested. Hybrid test cells delivered a critical current density of 3.0 mA cm –2 at 25 °C and 0.1 MPa, which is nearly double the CCD of comparable dry symmetric test cells cycled at 10× higher stack pressure.

25 ENERGY STORAGE↗

Investigation of MgO additives on microstructure and properties of thin LLZO electrolytes for all-solid-state batteries

To realize high-energy density lithium lanthanum zirconate (LLZO)-based solid-state batteries (SSB), LLZO electrolytes should be fabricated with low thickness and high mechanical strength. An effective strategy for strengthening ceramic materials is to use additives. Here, we employed MgO nanopowders and fibers as additives for the thin LLZO electrolyte in order to improve the mechanical strength. The microstructure, mechanical properties, and electrochemical properties are characterized to investigate the effects of adding MgO and sintering time. The MgO remains at grain boundaries after sintering, making the microstructure of LLZO fine and uniform. The mechanical strength of the MgO-added LLZO was enhanced by more than 60% while maintaining high ionic conductivity (1 × 10 -4 S cm -1 ) at room temperature. Li symmetric cells using the MgO fiber–LLZO and MgO powder–LLZO exhibit 2 and 3 times higher critical current density (CCD) than those of pure LLZO, and a solid-state full cell exhibits stable cycling performance. Further, these results demonstrate that the use of MgO nanopowder or fiber as an additive for thin LLZO is beneficial for high-current density cycling, by improving mechanical properties and microstructure.

25 ENERGY STORAGE↗

The Sloan Digital Sky Survey Quasar Catalog: Twelfth data release

In this paper, we present the Data Release 12 Quasar catalog (DR12Q) from the Baryon Oscillation Spectroscopic Survey (BOSS) of the Sloan Digital Sky Survey III. This catalog includes all SDSS-III/BOSS objects that were spectroscopically targeted as quasar candidates during the full survey and that are confirmed as quasars via visual inspection of the spectra, have luminosities M i [z = 2] < -20.5 (in a ΛCDM cosmology with H 0 = 70 km s -1 Mpc -1 , Ω M = 0.3, and Ω Λ = 0.7), and either display at least one emission line with a full width at half maximum (FWHM) larger than 500 km s -1 or, if not, have interesting/complex absorption features. The catalog also includes previously known quasars (mostly from SDSS-I and II) that were reobserved by BOSS. The catalog contains 297 301 quasars (272 026 are new discoveries since the beginning of SDSS-III) detected over 9376 deg 2 with robust identification and redshift measured by a combination of principal component eigenspectra. The number of quasars with z > 2.15 (184 101, of which 167 742 are new discoveries) is about an order of magnitude greater than the number of z > 2.15 quasars known prior to BOSS. Redshifts and FWHMs are provided for the strongest emission lines (C iv, C iii], Mg ii). The catalog identifies 29 580 broad absorption line quasars and lists their characteristics. For each object, the catalog presents five-band (u, g, r, i, z) CCD-based photometry with typical accuracy of 0.03 mag together with some information on the optical morphology and the selection criteria. When available, the catalog also provides information on the optical variability of quasars using SDSS and Palomar Transient Factory multi-epoch photometry. The catalog also contains X-ray, ultraviolet, near-infrared, and radio emission properties of the quasars, when available, from other large-area surveys. The calibrated digital spectra, covering the wavelength region 3600–10 500 Å at a spectral resolution in the range 1300 < R < 2500, can be retrieved from the SDSS Catalog Archive Server. Finally, we also provide a supplemental list of an additional 4841 quasars that have been identified serendipitously outside of the superset defined to derive the main quasar catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

Suzaku Observations of AGN and Synergy with GLAST

In next five years, dramatic progress is anticipated for the AGN studies, as we have two important missions to observe celestial sources in the high energy regime: GLAST and Suzaku. Suzaku is the 5th Japanese X-ray astronomy satellite which was successfully launched in July 2005. It carries four X-ray sensitive imaging CCD cameras (0.2-12 keV) located in the focal planes of X-ray telescope, and a non-imaging, collimated hard X-ray detector, which extends the bandpass of the observatory to include the 10-600 keV range. Simultaneous monitoring observations by the two instruments (GLAST and Suzaku) will be particularly valuable for variable radio-loud AGN, allowing the cross-correlations of time series as well as detailed modeling of the spectral evolution between the X-ray and gamma-ray energy bands. In this paper, we show early highlights from Suzaku observations of radio-loud AGNs, and discuss what we can do with GLAST in forthcoming years.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Studies of Fast Protons Originated from Fusion Reactions in Plasma-Focus Discharges

The paper describes results of the recent measurements of fusion-reaction protons, which were performed within the PF-360 facility operated at the IPJ in Swierk, Poland. The main aim of those studies was to perform time-integrated measurements of fast protons (of energy of about 3 MeV) by means of ion-pinhole cameras, which were equipped with solid state nuclear track detectors (SSNTD) of the PM-355 type and absorption filters made of thin metal foils. In order to determine the spatial distribution of fusion-produced protons the use was made of several miniature pinhole cameras placed at different angles to the PF-360 axis. The irradiated and etched detectors were analyzed with an optical microscope coupled with a CCD camera and a PC unit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Spectroscopy in ISTTOK

Plasma spectroscopy is a well established technique for impurities study in fusion plasmas. A brief description of the several spectroscopic systems which have been in operation at ISTTOK is given. In ISTTOK a passive spectroscopy diagnostic system is being used to perform spectral and spatial characterization in the 300-850 nm wavelength range. The system used to perform that work consist essentially of a cooled CCD camera coupled to a half a meter imaging spectrograph with collection optics based on a multi-fiber set to allow for enhanced spatial resolution. Experimental data is shown underlining typical plasma fusion spectral lines and specific ISTTOK characteristics. A web based data access tool is presented that allows the spectral plasma survey in specific wavelength ranges. The information provided by this survey has been used to select suitable transmission filters for a diagnostic, currently under development, to measure Zeff parameter for ISTTOK plasmas. A description of this diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impurity Line Emissions in VUV Region of TCABR Tokamak

Spectral emissions in the vacuum ultraviolet region from 50 nm to 320 nm have been measured on TCABR tokamak using an one meter VUV spectrometer and a MCP coupled to a CCD detector. Among the 98 emissions classified, 37 are from first order diffraction, 29 are from second order, 24 are from third order, 7 from fourth order, and one from fifth order diffraction. Main impurity lines are OII to OVII, CII to CIV, NIII to N V, FVII, besides working gas plasma hydrogen Lyman lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral Line Profile Analysis Using Higher Diffraction Order in Vacuum Ultraviolet Region

Using a one meter VUV spectrometer and a MCP coupled to a CCD detector on TCABR tokamak, ion temperatures from impurity species have been measured and much better spectral resolution was obtained using higher order diffraction lines. Due to very small Doppler effect in the VUV region compared to large instrumental broadening, ion temperatures obtained from first order diffraction present large errors. The use of second, third and fourth order diffraction emissions increases the line broadening and results in lower error temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thrust Measurements in Ballistic Pendulum Ablative Laser Propulsion Experiments

This paper describes a setup for thrust measurement in ablative laser propulsion experiments, based on a simple ballistic pendulum associated to an imaging system, which is being assembled at IEAv. A light aluminium pendulum holding samples is placed inside a 100 liters vacuum chamber with two optical windows: the first (in ZnSe) for the laser beam and the second (in fused quartz) for the pendulum visualization. A TEA-CO{sub 2} laser beam is focused to the samples providing ablation and transferring linear moment to the pendulum as a whole. A CCD video camera captures the oscillatory movement of the pendulum and the its trajectory is obtained by image processing. By fitting the trajectory of the pendulum to a dumped sinusoidal curve is possible to obtain the amplitude of the movement which is directly related to the momentum transfered to the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Swift-XRT positions of GRBs

Since GRBs fade rapidly, it is important to publish accurate, precise positions at early times. For Swift-detected bursts, the best promptly available position is most commonly the X-ray Telescope (XRT) position. We present two processes, developed by the Swift team at Leicester, which are now routinely used to improve the precision and accuracy of the XRT positions reported by the Swift team. Both methods, which are fully automated, make use of a PSF-fitting approach which accounts for the bad columns on the CCD. The first method yields positions with 90% error radii <4.4''90% of the time, within 10-20 minutes of the trigger. The second method astrometrically corrects the position using UVOT field stars and the known mapping between the XRT and UVOT detectors, yielding enhanced positions with 90% error radii of <2.8''90% of the time, usually 2 hours after the trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grazing-incidence spectrometer on the SSPX spheromak

The Silver Flat Field Spectrometer (SFFS) is a high-resolution grazing-incidence diagnostic for magnetically confined plasmas. It covers the wavelength range of 25-450 {angstrom} with a resolution of {Delta}{lambda} = 0.3 {angstrom} FWHM. The SFFS employs a spherical 1200 lines/mm grating for flat-field focusing. The imaging is done using a back-illuminated Photometrics CCD camera allowing a bandwidth of around 200 {angstrom} per spectrum. The spectrometer has been used for atomic spectroscopy on electron beam ion traps and for plasma spectroscopy on magnetic confinement devices. The design of the SFFS and the spectrometer setup at the Sustained Spheromak Physics Experiment (SSPX) in Livermore will be presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗