Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Short x-ray pulse generation using deflecting cavities at the Advanced Photon Source.

Storage-ring-based third-generation light sources can provide intense radiation pulses with durations as short as 100 ps. However, there is growing interest within the synchrotron radiation user community in performing experiments with much shorter X-ray pulses. Zholents et al. [Nucl. Instr. and Meth. A 425 (1999) 385] recently proposed using RF orbit deflection to generate sub-ps X-ray pulses. In this scheme, two deflecting cavities are used to deliver a longitudinally dependent vertical kick to the beam. An optical slit can then be used to slice out a short part of the radiation pulse. Implementation of this scheme is planned for one APS beamline in the near future. In this paper, we summarize our feasibility study of this method and the expected X-ray beam parameters. We find that a pulse length of less than two picoseconds can be achieved.

43 PARTICLE ACCELERATORS↗

Effects of the laser pulse irradiation point on a double layer target on the accelerated ion beam parameters

In proton acceleration by a laser pulse obliquely incident on a double layer target, it is shown by PIC simulations that the energy spread of the generated protons can be reduced by irradiating the laser pulse on to the off-center position of the target. This provides a way to control the proton energy spectrum. High energy protons are found to come from an area shifted from the initial target center towards the propagation direction of the laser pulse. We show that high energy protons with much smaller energy spread can be obtained by appropriately adjusting the size and position of the second proton layer.

43 PARTICLE ACCELERATORS↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

Large area fabrication of plasmonic nanoparticle grating structure by conventional scanning electron microscope

Plasmonic nanoparticle grating (PNG) structure of different periods has been fabricated by electron beam lithography using silver halide based transmission electron microscope film as a substrate. Conventional scanning electron microscope is used as a fabrication tool for electron beam lithography. Optical microscope and energy dispersive spectroscopy (EDS) have been used for its morphological and elemental characterization. Optical characterization is performed by UV-Vis absorption spectroscopic technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NIO1 diagnostics

The radio frequency ion source NIO1, jointly developed by Consorzio RFX and INFN-LNL, will generate a 60kV-135mA hydrogen negative ion beam, composed of 9 beamlets over an area of about 40 × 40 mm{sup 2}. This experiment will operate in continuous mode and in conditions similar to those foreseen for the larger ion sources of the Neutral Beam Injectors for ITER. The modular design of NIO1 is convenient to address the several still open important issues related to beam extraction, optics, and performance optimization. To this purpose a set of diagnostics is being implemented. Electric and water cooling plant related measurements will allow monitoring current, pressure, flow, and temperature. The plasma in the source will be characterized by emission spectroscopy, cavity ring-down and laser absorption spectroscopy. The accelerated beam will be analyzed with a fast emittance scanner, its intensity profile and divergence with beam emission spectroscopy and visible tomography. The power distribution of the beam on the calorimeter will be monitored by thermocouples and by an infrared camera. This contribution presents the implementation and initial operation of some of these diagnostics in the commissioning phase of the experiment, in particular the cooling water calorimetry and emission spectroscopy.

43 PARTICLE ACCELERATORS↗

Racetrack FFAG muon decay ring for nuSTORM with triplet focusing

The neutrino beam produced from muons decaying in a storage ring would be an ideal tool for precise neutrino cross section measurements and the search for sterile neutrinos due to its precisely known flavour content and spectrum. In the proposed nuSTORM facility, pions would be directly injected into a racetrack storage ring, where the circulating muon beam would be captured. In this paper we show that a muon decay ring based on a racetrack scaling FFAG (Fixed Field Alternating Gradient) with triplet focusing structures is a very promising option with potential advantages over the FODO based solution. Finally, we discuss the ring concept, machine parameters, linear optics design, beam dynamics and the injection system.

43 PARTICLE ACCELERATORS↗

New SC Algorithm for MAD-X

MAD-X allows to simulate space-charge effects by approximating the macroparticle ensemble with a Gaussian distribution and using analytic formulas for calculation of the space-charge kick at locations which should be chosen in advance e.g. with V. Kapin’s external code. The new MAD-X version features two innovations: a symplectic three-dimensional space-charge kick and Gaussian fit of particle distribution which – in principle – does not require a linearly stable closed optics to exist thus permitting simulations studies of the parametric resonance stopband crossing. It also allows for non stationary distribution so that envelope resonances can be simulated.

43 PARTICLE ACCELERATORS↗

Mitigation of Laser Beam Scintillation in Free-Space Optical Communication Systems Through Coherence-Reducing Optical Materials

Free-space optical communication systems (also known as lasercom systems) offer several performance advantages over traditional radio frequency communication systems. These advantages include increased data rates and reduced operating power and system weight. One serious limiting factor in a lasercom system is Optical turbulence in Earth's atmosphere. This turbulence breaks up the laser beam used to transmit the information into multiple segments that interfere with each other when the beam is focused onto the receiver. This interference pattern at the receiver changes with time causing fluctuations in the received optical intensity (scintillation). Scintillation leads to intermittent losses of the signal and an overall reduction in the lasercom system's performance. Since scintillation is a coherent effect, reducing the spatial and temporal coherence of the laser beam will reduce the scintillation. Transmitting a laser beam through certain materials is thought to reduce its coherence. Materials that were tested included: sapphire, BK7 glass, fused silica and others. The spatial and temporal coherence of the laser beam was determined by examining the interference patterns (fringes) it formed when interacting with various interferometers and etalons.

Renner, Christoffer J.↗

Beam Dynamics Simulations of Optically-Enhanced Field Emission from Structured Cathodes

Structured cathodes - cathodes with a segmented emission surface - are finding an increasing number of applications and can be combined with a variety of emission mechanisms, including photoemission and field emission. These cathodes have been used to enhance the quantum efficiency of metallic cathodes when operated as plasmonic cathodes, have produced high-current electron bunches though field emission from multiple tips, and can be used to form beams with transverse segmentations necessary for improving the performance of accelerator-based light sources. In this report we present recent progress towards the development of finite-difference time-domain particle-in-cell simulations using the emission process in structured cathodes based on the WARP framework. The simulations give further insight on the localized source of the emitted electrons which could be used for additional high-fidelity start-to-end simulations of electron accelerators that employ this type of electron source.

43 PARTICLE ACCELERATORS↗

Low-energy ion beam-based deposition of gallium nitride

An ion source with a remote plasma chamber excited by a 13.56 MHz radio frequency power was used for low-energy broad ion beam extraction. Optical emission spectral analyses showed the sputtering and postionization of a liquid gallium (Ga) target placed in a chamber separated from the source bombarded by argon (Ar) plasma guided by a bent magnetic field. In addition, an E × B probe successfully showed the extraction of low-energy Ga and Ar ion beams using a dual-electrode extractor configuration. By introducing dilute amounts of nitrogen gas into the system, formation of thin Ga-based films on a silicon substrate was demonstrated as determined from X-ray diffraction and X-ray reflectivity studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide-view charge exchange recombination spectroscopy diagnostic for Alcator C-Mod

This diagnostic measures temperature, density, and rotation for the fully stripped boron ion between the pedestal top and the plasma core with resolution consistent with the profile gradients. The diagnostic neutral beam used for the measurements generates a 50 keV, 6 A hydrogen beam. The optical systems provide views in both poloidal and toroidal directions. The imaging spectrometer is optimized to simultaneously accept 45 views as input with minimum cross-talk. In situ calibration techniques are applied for spatial location, spectral intensity, and wavelength. In the analysis, measured spectra are fitted to a model constructed from a detailed description of the emission physics. Methods for removal of interfering spectra are included. Applications include impurity and thermal transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ~100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-550: Radiochromic Plastic Thin Sheet Dosimeter: Initial Performance

Purpose: Thin sheets, of a high sensitivity formulation of radiochromic dosimeter, Presage were prepared and evaluated for optical readout. Methods: Sheets of radiochromic polyurethane, 12 cm long, 10 cm wide and 0.2 cm thick were prepared with leuco crystal violet as the reporter molecule. Sample transmission was evaluated at a wavelength of 590 nm with in-house constructed instruments: optical cone beam laser CT scanner, fixed and scanning spot densitometers. Sample sequential irradiations to a total dose of 40 Gy were conducted with a modified, Theratron 60, cobalt radiotherapy machine at dose rates of 1 or 0.25 Gy per minute. Exposure to ambient and readout light was minimized to limit background photochromic signals. Samples were stored at 4°C. Optical activity was assessed from linearly polarized transmission images. Comparison sensitivity measurements with EBT3 film were conducted. Results: Samples were transparent, smooth and pale purple before irradiation. Radiochromic reaction was completed in less than 5 minutes. A linear dose response with a sensitivity of 0.5 cm-1Gy-1 was observed. Micrometer measurements found sheet thickness variations up to 20%. Uniform dose, 2 Gy attenuation images, correlated with local sheet thicknesses. Comparable measurements with EBT3 film were 3 times more sensitive at 1 Gy but above 15 Gy, EBT3 film had lower sensitivity than 0.2 cm thick Presage sheet dosimeter due to its non-linear response. Conclusion: Dose sensitivity provided a 10% decrease in transmission for a 1 Gy dose. Improvements in mold design are expected to allow production of sheets with less than 5% variation in thickness. Above, 10 Gy, Presage sheet dosimeter performance expected to exceed EBT3 film based on linearity, sensitivity, transparency and smoothness of samples. J Adamovics is owner of Heuris Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artificial Temperature Anisotropy of Crystals in X-Ray Frequency Range

The effect of artificial temperature anisotropy of crystals in X-ray frequency range was observed for the first time and an effort to theoretically interpret this effect in Bragg-Laue diffraction case was made. It was established that an isotropic crystal optically turns into an artificially anisotropic one with optical axis along the direction of applied external influence as a symmetry axis, giving rise to the double refraction.

43 PARTICLE ACCELERATORS↗

Terahertz emission from a two-color plasma filament in a slot waveguide

Terahertz emission in forward direction from a long two-color filament placed in the center of a slot waveguide is reported. The waveguide improves the collection and imaging of the generated THz radiation. By tuning the plate separation and position of the waveguide along the filament axis, the emitted mode can be matched to the collection optics. We achieved an increase of the detected electric field by 40% and of the THz pulse energy by four times compared to the case without waveguide.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗