Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AmP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Standing Alfven wave current system at Io: Voyager 1 observations

The enigmatic control of the occurrence frequency of Jupiter's decametric emissions by the satellite Io is explained theoretically on the basis of its strong electrodynamic interaction with the corotating Jovian magnetosphere leading to field aligned currents connecting Io with the Jovian ionosphere. Direct measurements of the perturbation magnetic fields due to this current system were obtained by the magnetic field experiment on Voyager 1 on 5 March 1979 when it passed within 20,500 km south of Io. An interpretation in the framework of Alfven waves radiated by Io leads to current estimates of 2.8 million amps. A mass density of 7400 to 13600 proton mass units per Cu cm is derived which compares very favorably with independent observations of the torus composition characterized by 7-9 proton mass units per electron for a local electron density of 1050 to 1500 per cu cm. The power dissipated in the current system may be important for heating the Io heavy ion torus, inner magnetosphere, Jovian ionosphere, and possibly the ionosphere or even the interior of Io.

Acuna, M. H.↗

Toroidal cell and battery

A toroidal storage battery designed to handle relatively high amp-hour loads is described. The cell includes a wound core disposed within a pair of toroidal channel shaped electrodes spaced apart by nylon insulator. The shape of the case electrodes of this toroidal cell allows a first planar doughnut shaped surface and the inner cylindrical case wall to be used as a first electrode and a second planar doughnut shaped surface and the outer cylindrical case wall to be used as a second electrode. Connectors may be used to stack two or more toroidal cells together by connecting substantially the entire surface area of the first electrode of a first cell to substantially the entire surface area of the second electrode of a second cell. The central cavity of each toroidal cell may be used as a conduit for pumping a fluid through the toroidal cell to thereby cool the cell.

Nagle, W. J.↗

Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR)

The preliminary design of the cryogenic cooling system for the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR) instrument to be flown on the Atmospheric Magnetospheric Physics Satellite (AMPS) was studied. The top level trade studies were extensive due to the instrument requirement for cooling at three temperature levels as opposed to the two levels initially described for the instrument. Approximately 12 different combinations of cryogens were investigated. The basic lifetime requirement for the instrument was 30 days. However, studies were also conducted for a follow-up mission requiring a 1 year lifetime. The top level trades led to the selection of a single stage supercritical helium baseline.

Sherman, A.↗

Preparation and characterization of electrodes for the NASA Redox storage system

Electrodes for the Redox energy storage system based on iron and chromium chloride reactants is discussed. The physical properties of several lots of felt were determined. Procedures were developed for evaluating electrode performance in lab scale cells. Experimental procedures for evaluating electrodes by cyclic voltammetry are described which minimize the IR losses due to the high internal resistance in the felt (distributed resistance). Methods to prepare electrodes which reduced the coevolution of hydrogen at the chromium electrode and eleminate the drop in voltage on discharge occasionally seen with previous electrodes were discussed. Single cells of 0.3329 ft area with improved membranes and electrodes are operating at over 80% voltage efficiency and coulombic efficiencies of over 98% at current densities of 16 to 20 amp % ft.

Reid, M. A.↗

Effect of positive pulse charge waveforms on the energy efficiency of lead-acid traction cells

The effects of four different charge methods on the energy conversion efficiency of 300 ampere hour lead acid traction cells were investigated. Three of the methods were positive pulse charge waveforms; the fourth, a constant current method, was used as a baseline of comparison. The positive pulse charge waveforms were: 120 Hz full wave rectified sinusoidal; 120 Hz silicon controlled rectified; and 1 kHz square wave. The constant current charger was set at the time average pulse current of each pulse waveform, which was 150 amps. The energy efficiency does not include charger losses. The lead acid traction cells were charged to 70 percent of rated ampere hour capacity in each case. The results of charging the cells using the three different pulse charge waveforms indicate there was no significant difference in energy conversion efficiency when compared to constant current charging at the time average pulse current value.

Smithrick, J. J.↗

High resolution, low cost solar cell contact development

The MIDFILM cell fabrication and encapsulation processes were demonstrated as a means of applying low-cost solar cell collector metallization. The average cell efficiency of 12.0 percent (AM1, 28 C) was achieved with fritted silver metallization with a demonstration run of 500 starting wafers. A 98 percent mechanical yield and 80 percent electrical yield were achieved through the MIDFILM process. High series resistance was responsible for over 90 percent of the electrical failures and was the major factor causing the low average cell efficiency. Environmental evaluations suggest that the MIDFILM cells do not degrade. A slight degradation in power was experienced in the MIDFILM minimodules when the AMP Solarlok connector delaminated during the environmental testing.

Mardesich, N.↗

Effects of arc current on the life in burner rig thermal cycling of plasma sprayed ZrOsub2-Ysub2Osub3

An analysis of thermal cycle life data for four sets of eight thermal barrier coated specimens representing arc currents (plasma gun power) of 525, 600, 800, or 950 amps is presented. The ZrO2-8Y2O3/NiCrAlY plasma spray coated Rene 41 rods were thermal cycled to 1040 C in a Mach 0.3-Jet A/air burner flame. The experimental results indicate the existance of a minimum or threshold power level which coating life expectancy is less than 500 cycles. Above the threshold power level, coating life expectancy more than doubles and increases with arc current.

Hendricks, R. C.↗

The Conference on High Temperature Electronics

The status of and directions for high temperature electronics research and development were evaluated. Major objectives were to (1) identify common user needs; (2) put into perspective the directions for future work; and (3) address the problem of bringing to practical fruition the results of these efforts. More than half of the presentations dealt with materials and devices, rather than circuits and systems. Conference session titles and an example of a paper presented in each session are (1) User requirements: High temperature electronics applications in space explorations; (2) Devices: Passive components for high temperature operation; (3) Circuits and systems: Process characteristics and design methods for a 300 degree QUAD or AMP; and (4) Packaging: Presently available energy supply for high temperature environment.

Hamilton, D. J.↗

A low-power photovoltaic system with energy storage for radio communications: Description and design methodology

A low power photovoltaic system was constructed with approximately 500 amp hours of battery energy storage to provide power to an emergency amateur radio communications center. The system can power the communications center for about 72 hours of continuous nonsun operation. Complete construction details and a design methodology algorithm are given with abundant engineering data and adequate theory to allow similar systems to be constructed, scaled up or down, with minimum design effort.

Chapman, C. P.↗

Free electron lasers for transmission of energy in space

A one-dimensional resonant-particle model of a free electron laser (FEL) is used to calculate laser gain and conversion efficiency of electron energy to photon energy. The optical beam profile for a resonant optical cavity is included in the model as an axial variation of laser intensity. The electron beam profile is matched to the optical beam profile and modeled as an axial variation of current density. Effective energy spread due to beam emittance is included. Accelerators appropriate for a space-based FEL oscillator are reviewed. Constraints on the concentric optical resonator and on systems required for space operation are described. An example is given of a space-based FEL that would produce 1.7 MW of average output power at 0.5 micrometer wavelength with over 50% conversion efficiency of electrical energy to laser energy. It would utilize a 10 m-long amplifier centered in a 200 m-long optical cavity. A 3-amp, 65 meV electrostatic accelerator would provide the electron beam and recover the beam after it passes through the amplifier. Three to five shuttle flights would be needed to place the laser in orbit.

Segall, S. B.↗

Power management of multi-hundred kilowatt spacecraft power systems

A NASA-sponsored study of space power distribution system technology is in progress to develop an Autonomously Managed Power System (AMPS) for large space power platforms. The conceptual design of a 250 kW photovoltaic power system, including the power management subsystem (PMS), is presented. A PMS concept is derived based on the need to accommodate the increased complexity of a utility-type power system, and to minimize Shuttle resupply and ground station operational costs. The main PMS functions are discussed along with the control strategies of the autonomously managed power system.

Decker, D. K.↗

Binding of nickel /II/ to 5-prime-nucleoside monophosphates and related compounds

The interactions of Ni(II) cation with a representative suite of purine bases and the respective nucleosides and nucleotides have been studied by ultraviolet difference spectroscopy. Apparent association constants were determined for each system at pH 7.0, using computer linear regression coupled with an iteration technique. The specificity of binding of Ni(2+) for the purine nucleotides studied at pH 7.0 was 5-prime-GMP greater than 5-prime-AMP; a similar ordering was also found for the respective nucleosides and bases. In this study binding was not observed for the suite of pyramidines used, although an Ni(2+) -cytidine complex has been observed (Fiskin and Beer, 1965). It was also found that Ni(2+) bound more strongly to the purine 5-prime-nucleotides than to the respective nucleosides and bases. These trends are explained in terms of metal-ligand bonds and available bonding positions on the ligands. A role for metal-ion-nucleotide types of complexes is suggested in the processes that might have given rise to the origin of life.

Orenberg, J. B.↗

Photovoltaic stand-alone modular systems, phase 2

The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

Naff, G. J.↗

Apparatus and method for heating a material in a transparent ampoule

An improved process for heating a material within a fused silica ampoule by radiation through the wall of the ampoule, while simultaneously passing a cooling gas around the ampoule is described. The radiation passes through a screen of fused silica so as to remove those components capable of directly heating the silica, therby increasing the temperature of the material within the ampoule above the strain point of the ampoule, while maintaining the exterior of the ampoule cool enough to prevent rupturing the amp.

Holland, L. R.↗

Prostacyclin-induced hyperthermia - Implication of a protein mediator

The mechanism of the prostacyclin-linked hyperthermia is studied in rabbits. Results show that intracerebroventricular administration of prostacyclin (PGI2) induces dose-related hyperthermia at room temperature (21 C), as well as at low (4 C) and high (30 C) ambient temperatures. It is found that this PGI2-induced hyperthermia is not mediated by its stable metabolite 6-keto prostaglandin F-1(alpha). Only one of the three anion transport systems, the liver transport system, appears to be important to the central inactivation of pyrogen, prostaglandin E2, and PGI2. Phenoxybenzamine and pimozide have no thermolytic effect on PGI2-induced hyperthermia, while PGI2 still induces hyperthermia after norepinephrine (NE) and dopamine levels are depleted by 6-hydroxydopamine. Indomethacin and SC-19220 (a PG antagonist) do not antagonize PGI2 induced hyperthermia, while theophylline does not accentuate the PGI2-induced hyperthermia. However, the hyperthermic response to PGI2 is attenuated by central administration of the protein synthesis inhibitor, anisomycin. It is concluded that PGI2-induced hyperthermia is not induced by NE, dopamine, or cyclic AMP, but rather that a protein mediator is implicated in the induction of fever by PG12.

Kandasamy, S. B.↗

Deposition stress effects on thermal barrier coating burner rig life

A study of the effect of plasma spray processing parameters on the life of a two layer thermal barrier coating was conducted. The ceramic layer was plasma sprayed at plasma arc currents of 900 and 600 amps onto uncooled tubes, cooled tubes, and solid bars of Waspalloy in a lathe with 1 or 8 passes of the plasma gun. These processing changes affected the residual stress state of the coating. When the specimens were tested in a Mach 0.3 cyclic burner rig at 1130 deg C, a wide range of coating lives resulted. Processing factors which reduced the residual stress state in the coating, such as reduced plasma temperature and increased heat dissipation, significantly increased coating life.

Watson, J. W.↗

Land Mobile Satellite Service (LMSS) channel simulator: An end-to-end hardware simulation and study of the LMSS communications links

The design and implementation of the Land Mobile Satellite Service (LMSS) channel simulator as a facility for an end to end hardware simulation of the LMSS communications links, primarily with the mobile terminal is described. A number of studies are reported which show the applications of the channel simulator as a facility for validation and assessment of the LMSS design requirements and capabilities by performing quantitative measurements and qualitative audio evaluations for various link design parameters and channel impairments under simulated LMSS operating conditions. As a first application, the LMSS channel simulator was used in the evaluation of a system based on the voice processing and modulation (e.g., NBFM with 30 kHz of channel spacing and a 2 kHz rms frequency deviation for average talkers) selected for the Bell System's Advanced Mobile Phone Service (AMPS). The various details of the hardware design, qualitative audio evaluation techniques, signal to channel impairment measurement techniques, the justifications for criteria of different parameter selection in regards to the voice processing and modulation methods, and the results of a number of parametric studies are further described.

Salmasi, A. B.↗

An improved logarithmic amplifier circuit for PDS microdensitometers

A high speed logarithmic amplifier circuit for the Perkin-Elmer PDS microdensitometer is discussed. The circuit is designed around an Analog Devices 757p log-amp module. The amplifier produces undistorted profiles of rapidly changing, dense ( 4) images over the available range of scanning speeds. The circuit board was designed to replace directly the manufacturer supplied unit; neither electrical nor mechanical modifications of the basic PDS are required. The performance of the circuit is illustrated through its effects on the overall modulation transfer function of the instrument and by scans of a well exposed stellar image. Circuit diagrams and parts lists a mechanism for obtaining either circuit board layout art work or finished circuit boards are presented.

Anderson, C. M.↗