Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,207 records · Page 67

Stent Retriever Thrombectomy in Different Thrombus Locations of Anterior Cerebral Circulation

BackgroundMechanical thrombectomy (MT) is a safe and efficient treatment for acute ischemic stroke in patients with proximal anterior occlusion and large penumbra. We evaluated the technical and clinical success of MT in relation to the location of the occlusion (internal carotid artery, M1 and M2 segments of the middle cerebral artery).MethodsWe prospectively reviewed 130 patients of whom 105 met the inclusion criteria. Baseline clinical, procedural and imaging variables, technical outcome (TICI, thrombolysis in cerebral infarction), 24 h imaging outcome and three-month clinical outcome (mRS, modified Rankin Scale) were recorded. Differences between the groups were studied with statistical tests according to the type of the variable.ResultsThere were 37, 46 and 22 patients in the internal carotid artery (ICA), M1 and M2 groups, respectively. TICI 2b or 3 was achieved in 92 cases (88 %) with a non-significant trend towards a better recanalization outcome in the ICA and M1 groups. Overall, 57 of the 105 patients (55 %) experienced favorable clinical outcome (mRS ≤ 2) with no significant differences between the groups. Excellent outcome (mRS ≤ 1) was seen in 40 patients (39 %) and there proportionally more patients with excellent outcome in the ICA and M1 groups (ICA: 44 %, M1: 41 %, M2: 23 % of patients, p = 0.22).ConclusionsThere were no statistically significant differences in the technical or clinical outcomes between the different sites of occlusion (ICA, M1 or M2). There was a non-significant trend towards achieving excellent clinical outcome (3-month mRS ≤ 1) more often and better recanalization results in the two more proximal locations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid-Sparing Intensity-Modulated Radiotherapy for Early-Stage Squamous Cell Carcinoma of the True Vocal Cord

Purpose: To compare radiation doses to carotid arteries among various radiotherapy techniques for treatment of early-stage squamous cell carcinoma (SCC) of the true vocal cords. Methods and Materials: Five patients were simulated using computed tomography (CT). Clinical and planning target volumes (PTV) were created for bilateral and unilateral stage T1 vocal cord cancers. Planning risk volumes for the carotid arteries and spinal cord were delineated. For each patient, three treatment plans were designed for bilateral and unilateral target volumes: opposed laterals (LATS), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT), for a total of 30 plans. More than 95% of the PTV received the prescription dose (63Gy at 2.25 Gy per treatment). Results: Carotid dose was lowest with IMRT. With a bilateral vocal cord target, the median carotid dose was 10Gy with IMRT vs. 25 Gy with 3DCRT and 38 Gy with LATS (p < 0.05); with a unilateral target, the median carotid dose was 4 Gy with IMRT vs. 19 Gy with 3DCRT and 39 Gy with LATS (p < 0.05). The dosimetric tradeoff with IMRT is a small area of high dose in the PTV. The worst heterogeneity results were at a maximum point dose of 80 Gy (127%) in a unilateral target that was close to the carotid. Conclusions: There is no question that IMRT can reduce the dose to the carotid arteries in patients with early-stage vocal cord cancer. The question is whether the potential advantage of reducing the carotid dose outweighs the risk of tumor recurrence due to contouring errors and organ motion and the risk of complications from dose heterogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage Reirradiaton With Stereotactic Body Radiotherapy for Locally Recurrent Head-and-Neck Tumors

Purpose: In this study, we present our results of reirradiation of locally recurrent head-and-neck cancer with image-guided, fractionated, frameless stereotactic body radiotherapy technique. Methods and Materials: From July 2007 to February 2009, 46 patients were treated using the CyberKnife (Accuray, Sunnyvale, CA) at the Department of Radiation Oncology, Hacettepe University, Ankara, Turkey. All patients had recurrent, unresectable, and previously irradiated head-and-neck cancer. The most prominent site was the nasopharynx (32.6%), and the most common histopathology was epidermoid carcinoma. The planning target volume was defined as the gross tumor volume identified on magnetic resonance imaging and computed tomography. There were 22 female and 24 male patients. Median age was 53 years (range, 19-87 years). The median tumor dose with stereotactic body radiotherapy was 30 Gy (range, 18-35 Gy) in a median of five (range, one to five) fractions. Results: Of 37 patients whose response to therapy was evaluated, 10 patients (27%) had complete tumor regression, 11 (29.8%) had partial response, and 10 (27%) had stable disease. Ultimate local disease control was achieved in 31 patients (83.8%). The overall survival was 11.93 months in median (ranged, 11.4 - 17.4 months), and the median progression free survival was 10.5 months. One-year progression-free survival and overall survival were 41% and 46%, respectively. Grade II or greater long-term complications were observed in 6 (13.3%) patients. On follow-up, 8 (17.3%) patients had carotid blow-out syndrome, and 7 (15.2%) patients died of bleeding from carotid arteries. We discovered that this fatal syndrome occurred only in patients with tumor surrounding carotid arteries and carotid arteries receiving all prescribed dose. Conclusions: Stereotactic body radiotherapy is an appealing treatment option for patients with recurrent head-and-neck cancer previously treated with radiation to high doses. Good local control with considerable 1-year survival is achieved with a relatively high rate of morbidity and related mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microangiography in Living Mice Using Synchrotron Radiation

Traditionally, there are no methods available to detect the fine morphologic changes of cerebrovasculature in small living animals such as rats and mice. Newly developed synchrotron radiation microangiography can achieve a fine resolution of several micrometers and had provided us with a powerful tool to study the cerebral vasculature in small animals. The purpose of this study is to identify the morphology of cerebrovasculature especially the structure of Lenticulostriate arteries (LSAs) in living mice using the synchrotron radiation source at Shanghai Synchrotron Radiation Facility (SSRF) in Shanghai, China. Adult CD-1 mice weighing 35-40 grams were anesthetized. Nonionic iodine (Omnipaque, 350 mg I /mL) was used as a contrast agent. The study was performed at the BL13W1 beam line at SSRF. The beam line was derived from a storage ring of electrons with an accelerated energy of 3.5 GeV and an average beam current of 200 mA. X-ray energy of 33.3 keV was used to produce the highest contrast image. Images were acquired every 172 ms by a x-ray camera (Photonic-Science VHR 1.38) with a resolution of 13 {mu}m/pixel. The optimal dose of contrast agent is 100 {mu}l per injection and the injecting rate is 33 {mu}l/sec. The best position for imaging is to have the mouse lay on its right or left side, with ventral side facing the X-ray source. We observed the lenticulostriate artery for the first time in living mice. Our result show that there are 4 to 5 lenticulostriate branches originating from the root of middle cerebral artery in each hemisphere. LSAs have an average diameter of 43{+-}6.8 {mu}m. There were no differences between LSAs from the left and right hemisphere (p<0.05). These results suggest that synchrotron radiation may provide a unique tool for experimental stroke research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A retrospective comparison of smart prep and test bolus multi-detector CT pulmonary angiography protocols

Optimal arterial opacification is crucial in imaging the pulmonary arteries using computed tomography (CT). This poses the challenge of precisely timing data acquisition to coincide with the transit of the contrast bolus through the pulmonary vasculature. The aim of this quality assurance exercise was to investigate if a change in CT pulmonary angiography (CTPA) scanning protocol resulted in improved opacification of the pulmonary arteries. Comparison was made between the smart prep protocol (SPP) and the test bolus protocol (TBP) for opacification in the pulmonary trunk. A total of 160 CTPA examinations (80 using each protocol) performed between January 2010 and February 2011 were assessed retrospectively. CT attenuation coefficients were measured in Hounsfield Units (HU) using regions of interest at the level of the pulmonary trunk. The average pixel value, standard deviation (SD), maximum, and minimum were recorded. For each of these variables a mean value was then calculated and compared for these two CTPA protocols. Minimum opacification of 200 HU was achieved in 98% of the TBP sample but only 90% of the SPP sample. The average CT attenuation over the pulmonary trunk for the SPP was 329 (SD = ±21) HU, whereas for the TBP it was 396 (SD = ±22) HU (P = 0.0017). The TBP also recorded higher maximum (P = 0.0024) and minimum (P = 0.0039) levels of opacification. This study has found that a TBP resulted in significantly better opacification of the pulmonary trunk than the SPP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Appropriateness of Renal Angioplasty. The ANPARIA Software: A Multidisciplinary Expert Panel Approach

Percutaneous transluminal renal angioplasty (PTRA) is an invasive technique that is costly and involves the risk of complications and renal failure. The ability of PTRA to reduce the administration of antihypertensive drugs has been demonstrated. A potentially greater benefit, which nevertheless remains to be proven, is the deferral of the need for chronic dialysis. The aim of the study (ANPARIA) was to assess the appropriateness of PTRA to impact on the evolution of renal function. A standardized expert panel method was used to assess the appropriateness of medical treatment alone or medical treatment with revascularization in various clinical situations. The choice of revascularization by either PTRA or surgery was examined for each clinical situation. Analysis was based on a detailed literature review and on systematically elicited expert opinion, which were obtained during a two-round modified Delphi process. The study provides detailed responses on the appropriateness of PTRA for 1848 distinct clinical scenarios. Depending on the major clinical presentation, appropriateness of revascularization varied from 32% to 75% for individual scenarios (overal 48%). Uncertainty as to revascularization was 41% overall. When revascularization was appropriate, PTRA was favored over surgery in 94% of the scenarios, except in certain cases of aortic atheroma where sugery was the preferred choice. Kidney size >7 cm, absence of coexisting disease, acute renal failure, a high degree of stenosis ({>=}70%), and absence of multiple arteries were identified as predictive variables of favorable appropriateness ratings. Situations such as cardiac failure with pulmonary edema or acute thrombosis of the renal artery were defined as indications for PTRA. This study identified clinical situations in which PTRA or surgery are appropriate for renal artery disease. We built a decision tree which can be used via Internet: the ANPARIA software (http://www.chu-clermontferrand.fr/anpariahttp://www.chu-clermontferrand.fr/anparia/). In numerous clinical situations uncertainty remains as to whether PTRA prevents deterioration of renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lessons from EVA-3S and SPACE

Carotid endarterectomy (CEA) was established as the gold standard for treatment of carotid occlusive disease by several landmark papers published in the 1990s. With the continued trend toward less invasive therapies, carotid artery stenting (CAS) has challenged CEA for treatment of significant carotid artery disease. Several trials have now compared CEA and CAS and a subsequent Cochrane review indicated that the 30-day complication rates were equivalent. Unfortunately, comparative long-term data are still lacking. Two new trials comparing CAS with CAE in patients with symptomatic internal carotid artery disease have recently been published, but to what extent have they usefully added to the available data?.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Modified Metallic Coil Embolization Technique for Pulmonary Arteriovenous Malformations Using Coil Anchors and Occlusion Balloon Catheters

Purpose. To evaluate the feasibility and efficacy of a modified metallic coil embolization technique for pulmonary arteriovenous malformations (PAVMs) using coil anchors and occlusion balloon catheters. Methods. Five consecutive female patients with 6 PAVMs were included in the present study. One of the 6 PAVMs was of the complex type with four feeding arteries. An occlusion balloon catheter was inserted into the feeding artery as close to the venous sac as possible. The coil anchor, which was a simple W-shaped bent stainless steel wire with two markers at each end, was deployed prior to embolization to prevent the systemic migration of embolic materials. Then, metallic coils were deployed around the coil anchors under inflow stoppage using the inflated occlusion balloon catheter. In the complex-type PAVM, the main feeder was occluded by this technique and the other three small feeders were embolized with metallic coils only. Results. In all 5 cases, occlusion balloon catheters could be inserted into the feeding arteries just proximal to the venous sacs, coil anchors were easily deployed, and complete occlusion was achieved without any migration of metallic coils or paradoxical embolism during the procedure. Conclusions. The modified metallic coil embolization technique with coil anchors and occlusion balloon catheters was feasible and considered to be useful in preventing procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Evaluation of a New Embolic Spherical Particle (HepaSphere) in a Kidney Animal Model

HepaSphere is a new spherical embolic material developed in a dry state that absorbs fluids and adapts to the vessel wall, leaving no space between the particle and the arterial wall. The aim of this study was to elucidate the final in vivo size, deformation, final location, and main properties of the particles when reconstituted with two different contrast media (Iodixanol and Ioxaglate) in an animal model. Two sizes of 'dry-state' particles (50-100 and 150-200 {mu}m) were reconstituted using both ionic and nonionic contrast media. The mixture was used to partly embolize both kidneys in an animal model (14 pigs). The animals were sacrificed 4 weeks after the procedure and the samples processed. The final size of the particles was 230.2 {+-} 62.5 {mu}m for the 50- to 100-{mu}m dry-state particles and 314.4 {+-} 71 {mu}m for the 150- to 200-{mu}m dry-state particles. When the contrast medium (ionic versus nonionic) used for the reconstitution was studied to compare (Student's t-test) the final size of the particles, no differences were found (p > 0.05). The mean in vivo deformation for HepaSphere was 17.1% {+-} 12.3%. No differences (p > 0.05) were found in the deformation of the particle regarding the dry-state size or the contrast medium (Mann-Whitney test). We conclude that HepaSphere is stable, occludes perfectly, and morphologically adapts to the vessel lumen of the arteries embolized. There is no recanalization of the arteries 4 weeks after embolization. Its final in vivo size is predictable and the particle has the same properties in terms of size and deformation with the two different contrast media (Iodixanol and Ioxaglate)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Ischemic Model Using a Radiofrequency Wire Electrode in a Rabbit Hindlimb

The purpose of this study was to establish an ischemic rabbit hindlimb model using a radiofrequency (RF) wire electrode. We inserted a polytetrafluoroethylene-coated wire with a 2-cm exposed tip into the left superficial femoral artery of seven New Zealand white rabbits and performed RF ablation (RFA) while pulling the wire back. We assessed the clinical findings, angiography, computed tomography perfusion, and permeability surface until 6 weeks after RFA. The angiography demonstrated complete obstruction from the proximal external iliac artery to the distal superficial femoral artery and showed a gradual increment in the angiogenic score, which represents the degree of angiogenesis (r = 0.86, p < 0.0001). The left-to-right ratios of the computed tomography perfusion and permeability surface were significantly reduced after 4 days (p < 0.05), and then they gradually increased with time. We conclude that endovascular RFA using an RF wire electrode is a reproducible and measurable way to create an ischemic rabbit hindlimb model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of an Unusual Complication of Endovenous Laser Therapy: Multiple Small Arteriovenous Fistulas Causing Complete Recanalization

A 67-year-old woman was admitted to our institution with pain, night cramping, and visible varicose veins on her left leg. Doppler ultrasonography revealed continuous reflux in the great saphenous vein when the patient did the Valsalva maneuver. Endovenous laser therapy was applied to the great saphenous vein. Doppler ultrasonography 7 days later showed recanalization of, and arterialized flow in, the great saphenous vein. There also were small arterial vessels adjunct to the recanalized side. A left femoral angiography via a right femoral approach showed multiple small arteriovenous fistulas between superficial femoral artery muscle branches and the great saphenous vein. A second endovenous laser treatment was done at 80 J/cm, but the recanalization persisted. We offered to treat this endovascularly, but the patient preferred a surgical option. To the best of our knowledge, this is the first report of the demonstration of such a complication with endovenous laser therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment Strategies in Aortoiliac Occlusion

The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Unusual Complication Following Transarterial Chemoembolization: Acute Myocardial Infarction

Transarterial chemoembolization has been widely used to treat unresectable hepatocellular carcinoma. Various complications have been reported, but they have not included acute myocardial infarction. Acute myocardial infarction results mainly from coronary artery occlusion by plaques that are vulnerable to rupture or from coronary spasm, embolization, or dissection of the coronary artery. It is associated with significant morbidity and mortality. We present a case report that describes a patient with hepatocellular carcinoma who underwent transarterial chemoembolization and died subsequently of acute myocardial infarction. To our knowledge, there has been no previous report of this complication induced by transarterial chemoembolization for hepatocellular carcinoma. This case illustrates the need to be aware of acute myocardial infarction when transarterial chemoembolization is planned for the treatment of hepatocellular carcinoma, especially in patients with underlying coronary artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of Intravascular Changes of Superabsorbent Polymer Microsphere (SAP-MS) with Monochromatic X-Ray Imaging

This study was designed to evaluate the intravascular transformation behavior of superabsorbent polymer microsphere (SAP-MS) in vivo macroscopically by using monochromatic X-ray imaging and to quantitatively compare the expansion rate of SAP-MS among different kinds of mixtures. Fifteen rabbits were used for our study and transcatheter arterial embolization (TAE) was performed for their auricular arteries using monochromatic X-ray imaging. We used three kinds of SAP-MS (particle diameter 100-150 {mu}m) mixture as embolic spherical particles: SAP-MS(H) absorbed with sodium meglumine ioxaglate (Hexabrix 320), SAP-MS(V) absorbed with isosmolar contrast medium (Visipaque 270), and SAP-MS(S) absorbed with 0.9% sodium saline. The initial volume of SAP-MS particles just after TAE and its final volume 10 minutes after TAE in the vessel were measured to calculate the expansion rate (ER) (n = 30). Intravascular behavior of SAP-MS particles was clearly observed in real time at monochromatic X-ray imaging. Averaged initial volumes of SAP-MS (H) (1.24 x 10{sup 7} {mu}m{sup 3}) were significantly smaller (p < 0.001) than those of SAP-MS (V) (5.99 x 10{sup 7} {mu}m{sup 3}) and SAP-MS (S) (5.85 x 10{sup 7} {mu}m{sup 3}). Averaged final volumes of SAP-MS (H) were significantly larger than averaged initial volumes (4.41 x 10{sup 7} {mu}m{sup 3} vs. 1.24 x 10{sup 7} {mu}m{sup 3}; p < 0.0001, ER = 3.55). There were no significant difference between averaged final volumes and averaged initial volumes of SAP-MS (V) and SAP-MS (S). SAP-MS (H), which first travels distally, reaches to small arteries, and then expands to adapt to the vessel lumen, is an effective particle as an embolic agent, causing effective embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Pulmonary Embolism: Treatment with the Rotarex Thrombectomy System

This study was designed to evaluate the efficacy and safety of percutaneous mechanical thrombectomy (PMT) for acute massive pulmonary embolism (PE). Fourteen patients (8 men, 6 women) with a mean age of 55.4 (range, 38-71) years with acute massive PE were initially diagnosed by computed tomography (CT) and confirmed by pulmonary angiography. All patients presented with acute PE symptoms and hemodynamic compromise. Each patient was treated with Straub Rotarex thrombectomy device and five patients received additional thrombolysis. Technique success and clinical improvement were achieved in all patients without major complications. The mean pulmonary artery pressure (PAP) decreased from 37.6 {+-} 6.6 to 29 {+-} 6.4 mmHg (P < 0.01) after PMT. Partial arterial pressures of O{sub 2} (PaO{sub 2}) increased from 61.1 {+-} 9.2 to 88 {+-} 5.1 mmHg (P < 0.01). The Miller index was 0.67 {+-} 0.11 and 0.37 {+-} 0.13 (P < 0.01), respectively, before and after PMT (P < 0.01). Eleven patients had no recurrence of PE on a mean follow-up of 28.3 months, whereas the other three patients were lost to follow-up. The preliminary experience in our series suggests that the Straub Rotarex thrombectomy device, which has been utilized in peripheral arteries, also is useful for the treatment of acute massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Dedicated Balloon Catheter for Infrapopliteal Difficult Calcified Lesions in Diabetic Patients With Critical Limb Ischemia

The purpose of this study was to assess the technical performance and immediate procedural outcome of a new balloon catheter in the treatment of calcified lesions in infrapopliteal arterial disease. Sixty-one patients (81 vessels) with infrapopliteal arterial disease were evaluated. Seventy-four of the 81 treated vessels had total occlusions. The ReeKross 18 peripheral transluminal angioplasty catheter (ClearStream, Wexford, Ireland) is an 0.018-inch guidewire system with 4F sheath compatibility and a rigid shaft intended for enhanced pushability. Only technical procedural outcomes were recorded. In 37 of 61 patients (50 infrapopliteal severely stenosed or occluded vessels), an attempt with a standard balloon was made before the ReeKross 18 was used. In 24 patients, the ReeKross 18 was used as the primary catheter in 23 cases involving crural arteries and in 8 cases involving the foot. The ReeKross 18 crossed the lesion in 55 of 59 (93.2%) patients and 72 of 77 (94.5%) vessels, respectively. Postdilatation results for the 51 patients (64 target lesions) in whom ReeKross 18 balloon dilation was achieved showed <30% residual stenosis in all but 4 patients (5 lesions). Of the patients treated with the ReeKross 18 as the primary catheter, the technical success rate (no adjunctive treatment/stent) was obtained in 20 of 24 (83.3%) patients (27 of 31 [87.1%] target lesions). In the treatment of difficult calcified lesions, the choice of a high-pushability angioplasty catheter, such as the ReeKross 18, warrants consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗