Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IceCube Search for Neutrinos Coincident with Compact Binary Mergers from LIGO-Virgo’s First Gravitational-wave Transient Catalog

Using the IceCube Neutrino Observatory, we search for high-energy neutrino emission coincident with compact binary mergers observed by the LIGO and Virgo gravitational-wave (GW) detectors during their first and second observing runs. In this paper, we present results from two searches targeting emission coincident with the sky localization of each GW event within a 1000 s time window centered around the reported merger time. One search uses a model-independent unbinned maximum-likelihood analysis, which uses neutrino data from IceCube to search for pointlike neutrino sources consistent with the sky localization of GW events. The other uses the Low-Latency Algorithm for Multi-messenger Astrophysics, which incorporates astrophysical priors through a Bayesian framework and includes LIGO-Virgo detector characteristics to determine the association between the GW source and the neutrinos. No significant neutrino coincidence is seen by either search during the first two observing runs of the LIGO-Virgo detectors. We set upper limits on the time-integrated neutrino emission within the 1000 s window for each of the 11 GW events. These limits range from 0.02 to 0.7 GeV cm -2 . We also set limits on the total isotropic equivalent energy, E iso , emitted in high-energy neutrinos by each GW event. These limits range from 1.7 × 10 51 to 1.8 × 10 55 erg. We conclude with an outlook for LIGO-Virgo observing run O3, during which both analyses are running in real time.

79 ASTRONOMY AND ASTROPHYSICS↗

MalGen: Malware Generation with Specific Behaviors to Improve Machine Learning-based Detectors

In recent years, infections and damage caused by malware have increased at exponential rates. At the same time, machine learning (ML) techniques have shown tremendous promise in many domains, often out performing human efforts by learning from large amounts of data. Results in the open literature suggest that ML is able to provide similar results for malware detection, achieving greater than 99% classifcation accuracy [49]. However, the same detection rates when applied in deployed settings have not been achieved. Malware is distinct from many other domains in which ML has shown success in that (1) it purposefully tries to hide, leading to noisy labels and (2) often its behavior is similar to benign software only differing in intent, among other complicating factors. This report details the reasons for the diffcultly of detecting novel malware by ML methods and offers solutions to improve the detection of novel malware.

97 MATHEMATICS AND COMPUTING↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

Development of readout electronics for the CMS ME0 muon detector

The Large Hadron Collider (LHC) in the High Luminosity (HL-LHC) era will be upgraded to deliver instantaneous luminosities up to 5 X 10 34 cm -2 s -1 , five times more than the original design value. In order to maintain performance of the Compact Muon Solenoid (CMS) Experiment under these conditions, ME0 is one of the new muon detectors to be added, along with GE1/1, GE2/1, RE3/1 and RE4/1. ME0 uses the triple Gas Electron Multiplier (GEM) technology and is designed to cover the far-forward region of 2.0 < |η| < 2.8. Further, the readout electronics for ME0 must be designed to deal with high data rates and be sufficiently radiation hard to operate very close to the beamline. The design and development status of the readout electronics for ME0 are presented, along with recent results from integration tests performed using the latest electronics prototypes with GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

GEM detectors for the CMS endcap muon system: status of three new detector stations

The High-Luminosity LHC (HL-LHC, or Phase-2 LHC) will deliver proton-proton collisions at 5–7.5 times the nominal LHC luminosity, with an expected number of 140–200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the performance of muon triggering and reconstruction under high background, the forward part of the Muon Spectrometer of the CMS experiment will be upgraded with Gas Electron Multipliers (GEM) and improved Resistive Plate Chambers (iRPC) detectors. A first GEM station (GE1/1) was installed during Long Shutdown 2 (LS2, 2019–2021), a 2 nd station (GE2/1) of Triple-GEM detectors will be installed in winter 2023–24 and 2024–25, while a new 6-layer station (ME0) will be installed in the third Long Shutdown (LS3, 2026–2028). GE11 is considered an early Phase-2 upgrade as it will reduce the p T threshold by combining GEM and Cathode Strip Chamber (CSC) hits in the forward muon system at twice the LHC design luminosity ($\mathcal{L}$ = 2 · 10 34 cm -2 s -1 , 50 PU). After a successful start of Run-3 in 2022, with almost 40 fb -1 collected, the commissioning of the GE1/1 detector is nearly complete. Most chambers are operated stably with an efficiency in excess of 95%, next being the demonstration of the combined CSC-GEM trigger in 2023. The lessons learnt with the first large-area GEM station have lead to improvements in detector and electronics design for the Phase 2 detectors GE2/1 and ME0. This proceeding will discuss the progress made since last MPGD Conference (MPGD 2019), discussing the commissioning and early performance of GE1/1; the design improvements and start of construction of GE2/1; and the R&D currently ongoing for ME0.

47 OTHER INSTRUMENTATION↗

Core collapse supernova gravitational wave emission for progenitors of 9.6, 15, and 25 M ⊙

Here, we present gravitational wave emission predictions based on three core collapse supernova simulations corresponding to three different progenitor masses. The masses span a large range, between 9.6 and 25M ⊙ , are all initially nonrotating, and are of two metallicities: zero and solar. We compute both the temporal evolution of the gravitational wave strains for both the plus and the cross polarizations, as well as their spectral decomposition and characteristic strains. The temporal evolution of our zero metallicity 9.6M ⊙ progenitor model is distinct from the temporal evolution of our solar metallicity 15M ⊙ progenitor model and our zero metallicity 25M ⊙ progenitor model. In the former case, the high-frequency gravitational wave emission is largely confined to a brief time period ~75 ms after bounce, whereas in the latter two cases high-frequency emission does not commence until ~125 ms after bounce or later. The excitation mechanisms of the high-frequency emission in all three cases correspond to proto-neutron star convection and accretion onto the proto-neutron star from the convective gain layer above it, with the former playing the dominant role for most of the evolution. The low-frequency emission in all three models exhibits very similar behavior. At frequencies below ~250 Hz, gravitational waves are emitted by neutrino-driven convection and the standing accretion shock instability (SASI). This emission extends throughout the simulations when a gain region is present. In all three models, explosion is observed at ~125, ~500, and ~250 ms after bounce in the 9.6, 15, and 25M ⊙ progenitor models, respectively. At these times, the low-frequency gravitational wave emission is joined by very low-frequency emission, below ~10 Hz. These very low-frequency episodes are the result of explosion and begin at the above designated explosion times in each of our models. Our characteristic strains tell us that, in principle, all three gravitational wave signals would be detectable by current-generation detectors for a supernova at a distance of 10 kpc. However, our 9.6M ⊙ progenitor model is a significantly weaker source of gravitational waves, with strain amplitudes approximately 5–10 times less than in our other two models. The characteristic strain for this model tells us that such a supernova would be detectable only within a much more narrow frequency range around the maximum sensitivity of today’s detectors. Finally, in our 9.6M ⊙ progenitor model, we see very high-frequency gravitational radiation, extending up to ~2000 Hz. This feature results from the interaction of shock- and deleptonization-induced convection with perturbations introduced in the progenitor by nuclear burning during core collapse. While unique to the 9.6M ⊙ progenitor model analyzed here, this very high-frequency emission may, in fact, be a generic feature of the predictions for the gravitational wave emission from all core collapse supernova models when simulations are performed with three-dimensional progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages

Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of 241 Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Bound-preserving finite element approximations of the Keller–Segel equations

We report this paper aims to develop numerical approximations of the Keller–Segel equations that mimic at the discrete level the lower bounds and the energy law of the continuous problem. We solve these equations for two unknowns: the organism (or cell) density, which is a positive variable, and the chemoattractant density, which is a non-negative variable. We propose two algorithms, which combine a stabilized finite element method and a semi-implicit time integration. The stabilization consists of a nonlinear artificial diffusion that employs a graph-Laplacian operator and a shock detector that localizes local extrema. As a result, both algorithms turn out to be nonlinear and can generate cell and chemoattractant numerical densities fulfilling lower bounds. However, the first algorithm requires a suitable constraint between the space and time discrete parameters, whereas the second one does not. We design the latter to attain a discrete energy law on acute meshes. We report some numerical experiments to validate the theoretical results on blowup and nonblowup phenomena. In the blowup setting, we identify a locking phenomenon that relates the L ∞ (Ω)-norm to the L 1 (Ω)-norm limiting the growth of the singularity when supported on a macroelement.

97 MATHEMATICS AND COMPUTING↗

Search for Higgs boson pair production in the $\mathrm{b}\overline{\mathrm{b}}\mathrm{WW}$ decay channel with two leptons in the final state using proton-proton collision data at $\sqrt{s}=13.6$ TeV

A search for Higgs boson pair production is presented, targeting final states where one Higgs boson decays to a bottom quark-antiquark pair and the other Higgs boson decays to two W bosons, both of which decay leptonically, to an electron or a muon, and a neutrino. For the first time, the search is conducted with proton-proton collision data from the LHC at $\sqrt{s}=13.6$ TeV, recorded with the CMS detector in 2022 and 2023 and corresponding to an integrated luminosity of 62 fb −1 . The results are consistent with the standard model predictions. An upper limit of 12.0 times the standard model prediction at 95% confidence level is set on the Higgs boson pair production cross section, with an expected limit of 18.5. The results are also used to constrain the strength of the trilinear self-coupling of the Higgs boson, as well as of the quartic coupling between two Higgs bosons and two vector bosons.

Hadron-Hadron Scattering↗

A Time-Gated, Time-Correlated Single-Photon-Counting Lidar to Observe Atmospheric Clouds at Submeter Resolution

Most lidars used for cloud observations have the range resolution of about 10 m, so they are incapable of resolving submeter-scale processes that are crucial to cloud evolution. This article describes a prototype of a ground-based, vertically pointing, time-gated, time-correlated single-photon-counting lidar (referred to as the T2 lidar) developed to explore atmospheric clouds at range resolution two orders of magnitude finer than traditional atmospheric lidars. The T2 lidar emits green-light pulses (532 nm) at a repetition rate of 20.6 kHz and a pulse width of ∼650 ps, which enables the observation of aerosol and cloud layers at heights from a few hundred meters to 7.28 km above the ground level at range resolution down to 10 cm. In addition, a digital delay pulse generator controls the detector to only receive photons for a short period after each laser pulse. This time-gated technique blocks photons arriving from regions outside the target zone, thus significantly reducing the noise level and allowing observation even inside clouds. Initial observations show that the T2 lidar can detect sharp cloud boundaries and fine structures near the cloud base. Such refined measurements of cloud structure could lead to an improved understanding of microphysical processes such as droplet activation, entrainment and mixing, and precipitation.

54 ENVIRONMENTAL SCIENCES↗