Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Fast modulating electron cyclotron emission (FMECE) diagnostic for tokamaks

Utilizing variable-frequency channels, e.g., yttrium iron garnet (YIG) bandpass filters, in the intermediate frequency (IF) section of an electron cyclotron emission (ECE) radiometer facilitates flexibility in the volume viewed by the ECE channels as well as high resolution electron temperature and temperature fluctuation measurements in tokamaks. Fast modulating electron cyclotron emission (FMECE), a stand-alone IF section with eight channels, is a novel application of YIG filters for real-time electron temperature gradient and gradient scale length measurements. Key to FMECE is a simultaneous input/output data acquisition unit, as well as a modified type of YIG filters, which is capable of fast switching of their center (set) frequencies with a frequency slew rate of 600 μs/GHz. A new FMECE has been implemented and tested on the DIII-D tokamak, demonstrating its capability in real-time gradient measurements. Here, the data presented here shows that FMECE can identify flattening in the electron temperature profile; the latter can be used as a sensor for real time monitoring and control of plasma instabilities. Implementation and application are planned for the EAST tokamak.

47 OTHER INSTRUMENTATION↗

Quantifying the Thermodynamic Impacts on the Atmospheric Boundary Layer due to the Sea Breeze in the Coastal Houston Region

The atmospheric boundary layer (ABL) is unique in coastal regions because of kinematic and thermodynamic influences from continental and marine environments. Sea-breeze (SB) circulations act to equilibrate the land–sea temperature gradient through advecting marine air onshore. The strength of the SB varies in terms of stability, temperature, and moisture advection and influences air quality and weather forecasts. The Tracking Aerosol Convection Interactions Experiment (TRACER) collected a wealth of data on coastal boundary layer evolution, including observations from uncrewed aerial systems (UASs). Vertical profiles of temperature, humidity, and winds were collected by the OU CopterSonde UAS from June to September in the coastal region of Houston. These profiles offer 5-m vertical resolution, on average, every 30 min through diurnal transitions, SB events, and nearby deep convection. During the campaign, CopterSonde observations were gathered through 17 SB events, six of which led to convection initiation. The UAS data can resolve the thermodynamic evolution and interactions between the SB and the preexisting convective boundary layer. Results show large variability across observed SBs and their impacts on temperature and moisture. The intensity of thermodynamic changes depends on the time of sea-breeze passage and influence from the Galveston Bay Breeze, a secondary marine circulation commonly observed in this region. In quantifying the spectrum of SB impacts, equivalent potential temperature θ e is used to contextualize its role in convection initiation and evolution. In conclusion, while all SBs tend to increase θ e from moisture advection, the rate and timing of the θ e rise can distinguish convective from nonconvective cases.

54 ENVIRONMENTAL SCIENCES↗

Thermal stability of the surface layer and its relation to the dispersion of primary pollutants in St. Louis

The present investigation is concerned with the applicability of the vertical temperature gradient, DT, as a dispersion parameter for urban area sources. Data on DT were tabulated from temperature measurements at 5 m and 30 m obtained on 30 m towers at 12 stations. DT was obtained by subtracting the value at 5 m from that at 30 m. Positive DT values represent an inversion. Accuracy of the DT data is 0.1 K. Hourly measurements of DT along with concentrations of the primary pollutants, CO, NO, and total hydrocarbons (THC), are available from the 1976 RAPS data base for St. Louis. Linear correlations between a given pollutant species concentration and DT are developed from that data set. It could be confirmed that a strong positive correlation exists at night between the thermal stability of the lowest part of the boundary layer and the urban concentration of the primary pollutants CO, NO, and hydrocarbons.

Remsberg, E. E.↗

Combination Heat-Flux and Temperature Gage

Instrument measures both temperature and temperature gradient in confined areas. With thermopile embedded in epoxy close to thermocouple, single unit measures both temperature and heat flow. Epoxy selected for low thermal conductivity and compatibility with test environment.

Knox, E. C.↗

Time- and position-varying infrared scene simulation

Rapidly changing infrared scenes can be generated as a function of position using thermally produced irradiance. This can be done most conveniently by using a variable dwell-time, variable diameter, and scanning laser beam to deposit a predetermined amount of laser energy, as a function of position, on the target surface. An infrared target simulator has been designed and tested to perform within stringent temperature simulation requirements: heating rate of over 100 K/sec is achieved, and temperature gradients of 200 K/mm can be maintained. Problems with heat transfer between adjacent elements at different temperatures are solved by modeling the thermal layer on the target surface as a low-pass filter, which cuts off all the frequencies above the thermal cutoff frequency. When the system approach is taken to the infrared simulation design, the optical system limited performance results in the best realizable performance. In this case, the thermal layer on the target surface is designed so that the thermal cutoff frequency is above the optical cutoff frequency.

Scholl, Marija S.↗

Optical experiments on thermophoretically augmented submicron particle deposition from 'dusty' high temperature gas flows

A real-time laser reflectivity method and Pt ribbon targets are used to obtain experimental data on the initial deposition rate of MgO(s) particles of approximately 700 nm diameter from otherwise clean combustion products as a function of target temperature (about 950-1450 K) and mainstream gas temperature (about 1500-1600 K). These preliminary data are used to demonstrate the dominant role of thermophoresis (particle drift down a temperature gradient) and to assess the utility of recently developed theoretical methods for predicting and correlating the temperature dependence of thermophoretically augmented convective-diffusion 'dust' deposition rates from flowing hot gases.

Rosner, Daniel E.↗

Topology of microwave background fluctuations - Theory

Topological measures are used to characterize the microwave background temperature fluctuations produced by 'standard' scenarios (Gaussian) and by cosmic strings (non-Gaussian). Three topological quantities: total area of the excursion regions, total length, and total curvature (genus) of the isotemperature contours, are studied for simulated Gaussian microwave background anisotropy maps and then compared with those of the non-Gaussian anisotropy pattern produced by cosmic strings. In general, the temperature gradient field shows the non-Gaussian behavior of the string map more distinctively than the temperature field for all topology measures. The total contour length and the genus are found to be more sensitive to the existence of a stringy pattern than the usual temperature histogram. Situations when instrumental noise is superposed on the map, are considered to find the critical signal-to-noise ratio for which strings can be detected.

Gott, J. Richard, III↗

Preliminary analysis for a Mach 8 crossflow transition experiment on the Pegasus (R) space booster

A boundary-layer transition is proposed for a future flight mission of the air-launched Pegasus space booster. The flight experiment requires attaching a glove assembly to the wing of the first-stage booster. The glove design consists of a spring and hook attachment system which allows for thermal growth of a steel 4130 skin. The results from one- and two-dimensional thermal analyses of the initial design are presented. Results obtained from the thermal analysis using turbulent flow conditions showed a maximum temperature of approximately 305 C and a chordwise temperature gradient of less than 8.9 C/cm for the critical areas in the upper glove skin. The temperatures obtained from these thermal analyses are well within the required temperature limits of the glove.

Gong, Leslie↗

Oxygen Isotopes in Fresh Water Biogenic Opal: Northeastern US Alleroed-Younger Dryas Temperature Shift

The first oxygen isotope analysis of biogenic opal from lake sediments, from the Allerod/Younger Dryas transition in a core from Linsley Pond, Connecticut, gives an average estimate of a 6 C drop in temperature during the Younger Dryas. This shift represents temperatures during the bloom season, and may be less than the winter temperature drop. The sharp transition itself, with a duration of about 200 years, suggests that the temperature decrease may have been as large as 12 C. Previous estimates of the Allerod/Younger Dryas temperature shifts are controversial, and range from 3-20 C, suggesting that further interdisciplinary research on the same samples is warranted. One way that global climate change manifests itself is by redistributing energy throughout the globe. The Northern Hemisphere latitudinal temperature gradient during the late-glacial is at present a controversial topic. The magnitude of air temperature shifts during the Allerod/Younger Dryas (YD) oscillation are estimated from mid-latitude pollen records surrounding the North Atlantic to be 3-5 C in Europe [Lowe et al., 19941 and 3-4 C in the eastern US [Peteet et al., 1993]. In contrast, lake temperatures estimates derived from aquatic midge larvae in the Canadian eastern maritimes and Maine range from 6-20 C, with larger shifts at more southern sites [Levesque et al., 1997]. The magnitude of YD cooling in Greenland ice cores ranges from at least 7 C from the Bolling warming [Dansgaard et al., 1989] to 15 C - a more recent estimate from borehole temperatures [Cuffey et al., 1995]. The ice core geochemical records reveal that massive frequent and short-term (decadal or less) changes in atmospheric composition occurred throughout this event, suggesting a very dynamic circulation [Mayewski et al., 1993).

Shemesh, Aldo↗

Seasonal Changes in Surface Temperatures on Titan

The surface brightness temperatures on Titan have been measured by the Composite Infrared Spectrometer (CIRS) aboard Cassini during the period spanning late northern winter through vernal equinox. CIRS observes radiance from the surface through a spectral window at 19 microns where the atmosphere has an opacity minimum [I]. CIRS is now seeing a shift in the latitudinal distribution of temperatures froth a distinctly warmer south to a more symmetrical north -south pattern, similar to that found by Voyager IRIS [2,3] at the time of the previous vernal equinox. Near the equator the temperatures remain close to the 93.7 K value found at the surface by Huygens [4]. From the equator to the poles the temperature gradients are 2-3 K. When compared with predictions froth general circulation models [5] the measured temperatures and their seasonal changes constrain the possible types of surface material. As Cassini continues through Titan's northern spring CiRS will extend its, global coverage to took for correlations between surface temperatures and albedo and to search for diurnal temperature variations

Jennings, D. E.↗

Subsurface Emission Effects in AMSR-E Measurements: Implications for Land Surface Microwave Emissivity Retrieval

An analysis of land surface microwave emission time series shows that the characteristic diurnal signature associated with subsurface emission in sandy deserts carry over to arid and semi-arid region worldwide. Prior work found that diurnal variation of Special Sensor Microwave/Imager (SSM/I) brightness temperatures in deserts was small relative to International Satellite Cloud Climatology Project land surface temperature (LST) variation and that the difference varied with surface type and was largest in sand sea regions. Here we find more widespread subsurface emission effects in Advanced Microwave Scanning Radiometer-EOS (AMSR-E) measurements. The AMSR-E orbit has equator crossing times near 01:30 and 13 :30 local time, resulting in sampling when near-surface temperature gradients are likely to be large and amplifying the influence of emission depth on effective emitting temperature relative to other factors. AMSR-E measurements are also temporally coincident with Moderate Resolution Imaging Spectroradiometer (MODIS) LST measurements, eliminating time lag as a source of LST uncertainty and reducing LST errors due to undetected clouds. This paper presents monthly global emissivity and emission depth index retrievals for 2003 at 11, 19, 37, and 89 GHz from AMSR-E, MODIS, and SSM/I time series data. Retrieval model fit error, stability, self-consistency, and land surface modeling results provide evidence for the validity of the subsurface emission hypothesis and the retrieval approach. An analysis of emission depth index, emissivity, precipitation, and vegetation index seasonal trends in northern and southern Africa suggests that changes in the emission depth index may be tied to changes in land surface moisture and vegetation conditions

Galantowicz, John F.↗

Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three- dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp'TM' Authoring Workspace which performs automated integration between Pro-Engineer®, Thermal Desktop®, MSC Nastran'TM', SigFit'TM', Code V'TM', and MATLAB®. This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.

Scola, Salvatore J.↗

Plant invasion impacts on fungal community structure and function depend on soil warming and nitrogen enrichment

The impacts of invasive species on biodiversity may be mitigated or exacerbated by abiotic environmental changes. Invasive plants can restructure soil fungal communities with important implications for native biodiversity and nutrient cycling, yet fungal responses to invasion may depend on numerous anthropogenic stressors. In this study, we experimentally invaded a long-term soil warming and simulated nitrogen deposition experiment with the widespread invasive plant Alliaria petiolata (garlic mustard) and tested the responses of soil fungal communities to invasion, abiotic factors, and their interaction. We focused on the phytotoxic garlic mustard because it suppresses native mycorrhizae across forests of North America. We found that invasion in combination with warming, but not under ambient conditions or elevated nitrogen, significantly reduced soil fungal biomass and ectomycorrhizal relative abundances and increased relative abundances of general soil saprotrophs and fungal genes encoding for hydrolytic enzymes. These results suggest that warming potentially exacerbates fungal responses to plant invasion. Soils collected from uninvaded and invaded plots across eight forests spanning a 4 °C temperature gradient further demonstrated that the magnitude of fungal responses to invasion was positively correlated with mean annual temperature. Our study is one of the first empirical tests to show that the impacts of invasion on fungal communities depends on additional anthropogenic pressures and were greater in concert with warming than under elevated nitrogen or ambient conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Energy transfer process of anisothermal wall-bounded flows

Strong temperature gradients introduce a major external agency into the wall-bounded turbulent flows. In these flows, the temperature field and the turbulent velocity field are highly correlated. In fact, standard RANS turbulent models are not able to accurately reproduce these flows. In order to improve the performance of the models, we need to understand how the energy is produced, transferred, and dissipated in a strong anisothermal wall-bounded flow. Overall, this letter presents a first detailed investigation on the roles played by each contributor in the energy transfer equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Theory for the Response of Tropical Moist Convection to Mechanical Orographic Forcing

Abstract Spatial patterns of tropical rainfall are strongly influenced by mountains. Although theories for precipitation induced by convectively stable upslope ascent exist for the midlatitudes, these do not represent the interaction of moist convection with orographic forcing. Here, we present a theory for convective precipitation produced by the mechanical interaction of a tropical ridge with a basic-state horizontal wind. Deviations from this basic state are represented as the sum of a “dry” perturbation, due to the stationary orographic gravity wave, and a “moist” perturbation that carries the convective response. The moist component dynamics are subject to the weak temperature gradient approximation; they are forced by the dry mode’s influence on lower-tropospheric moisture and temperature. Analytical solutions provide estimates of the precipitation distribution, including peak precipitation, upstream extent, and rain shadow extent. The theory can be used with several degrees of complexity depending on the technique used to compute the dry mode, which can be drawn from linear mountain wave theory or full numerical simulations. To evaluate the theory, we use a set of convection-permitting simulations with a flow-perpendicular ridge in a long channel. The theory makes a good prediction for the cross-slope precipitation profile, indicating that the organization of convective rain by orography can be quantitatively understood by considering the effect of stationary orographic gravity waves on a lower-tropospheric convective quasi-equilibrium state.

54 ENVIRONMENTAL SCIENCES↗

Integral Solution of Two-Region Solid–Liquid Phase Change in Annular Geometries and Application to Phase Change Materials–Air Heat Exchangers

A mathematical model based on the integral method is developed to solve the problem of conduction-controlled solid–liquid phase change in annular geometries with temperature gradients in both phases. The inner and outer boundaries of the annulus were subject to convective, constant temperature or adiabatic boundary conditions. The developed model was validated by comparison with control volume-based computational results using the temperature-transforming phase change model, and an excellent agreement was achieved. The model was used to conduct parametric studies on the effect of annuli geometry, thermophysical properties of the phase change materials (PCM), and thermal boundary conditions on the dynamics of phase change. For an initially liquid PCM, it was found that increasing the radii ratio increased the total solidification time. Also, increasing the Biot number at the cooled (heated) boundary and Stefan number of the solid (liquid) PCM, decreased (increased) the solidification time and resulted in a greater (smaller) solid volume fraction at steady state. The application of the developed method was demonstrated by design and analysis of a PCM–air heat exchanger for HVAC systems. The model can also be easily employed for design and optimization of annular PCM systems for all associated applications in a fraction of time needed for computational simulations.

Shabgard, Hamidreza↗

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗

Air-Cooled Turbine Blades with Tip Cap For Improved Leading-Edge Cooling

An investigation was conducted in a modified turbojet engine to determine the cooling characteristics of the semistrut corrugated air- cooled turbine blade and to compare and evaluate a leading-edge tip cap as a means for improving the leading-edge cooling characteristics of cooled turbine blades. Temperature data were obtained from uncapped air-cooled blades (blade A), cooled blades with the leading-edge tip area capped (blade B), and blades with slanted corrugations in addition to leading-edge tip caps (blade C). All data are for rated engine speed and turbine-inlet temperature (1660 F). A comparison of temperature data from blades A and B showed a leading-edge temperature reduction of about 130 F that could be attributed to the use of tip caps. Even better leading-edge cooling was obtained with blade C. Blade C also operated with the smallest chordwise temperature gradients of the blades tested, but tip-capped blade B operated with the lowest average chordwise temperature. According to a correlation of the experimental data, all three blade types 0 could operate satisfactorily with a turbine-inlet temperature of 2000 F and a coolant flow of 3 percent of engine mass flow or less, with an average chordwise temperature limit of 1400 F. Within the range of coolant flows investigated, however, only blade C could maintain a leading-edge temperature of 1400 F for a turbine-inlet temperature of 2000 F.

Calvert, Howard F.↗