Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Investigation of Thulium and Other Rare Earth Element Mass Fractions in NIST SRM 1632a Bituminous Coal Reference Material by Quadrupole ICP-MS

Inductively coupled plasma-mass spectrometry after lithium metaborate fusion and digestion was used to measure the rare earth element (REE) mass fractions of several reference materials including NIST SRM 1632a, a historical bituminous Pennsylvania seam coal. While most of the REE mass fractions measured in this study were consistent with the published consensus data, the measured mass fraction of thulium for NIST SRM 1632a was consistently lower compared with the published data. Chondrite normalisation of the published consensus data for NIST SRM 1632a produced a positive thulium anomaly (Tm = 1.78), which is inconsistent with a terrestrial source of sediment. The Normalisation of REE mass fractions collected in this study produced no significant Tm anomaly (Tm = 0.93), which agrees with the sedimentary depositional environment of coal. Therefore, a revised mass fraction of 0.16 mg kg -1 Tm in NIST SRM 1632a is recommended.

58 GEOSCIENCES↗

Mass spectrometric approaches for chemical characterisation of atmospheric aerosols: critical review of the most recent advances

This manuscript presents an overview of the most recent instrument developments for the field and laboratory applications of mass spectrometry (MS) to investigate the chemistry and physics of atmospheric aerosols. A range of MS instruments, employing different sample introduction methods, ionisation and mass detection techniques are used both for ‘online’ and ‘offline’ characterisation of aerosols. Online MS techniques enable detection of individual particles with simultaneous measurement of particle size distributions and aerodynamic characteristics and are ideally suited for field studies that require high temporal resolution. Offline MS techniques provide a means for detailed molecular-level analysis of aerosol samples, which is essential to gain fundamental knowledge regarding aerosol chemistry, mechanisms of particle formation and atmospheric aging. Combined, complementary MS techniques provide comprehensive information on the chemical composition, size, morphology and phase of aerosols – data of key importance for evaluating hygroscopic and optical properties of particles, their health effects, understanding their origins and atmospheric evolution. Over the last few years, developments and applications of MS techniques in aerosol research have expanded remarkably as evident by skyrocketing publication statistics. Finally, the goal of this review is to present the most recent developments in the field of aerosol mass spectrometry for the time period of late 2010 to early 2012, which have not been conveyed in previous reviews.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis

In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid–liquid and liquid–vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable to use for in situ liquid SIMS to study solid–liquid and liquid–vacuum interfaces.

36 MATERIALS SCIENCE↗

A Library of Proton-Transfer Reactions of H{sub 3}O{sup +} Ions Used for Trace Gas Detection

We have collected data on the proton-transfer reactions with H{sub 3}O{sup +} ions for trace gas detection into an online and publicly available library. The library allows users of proton-transfer-reaction mass spectrometry (PTR-MS) and selected-ion flow-tube mass spectrometry (SIFT-MS) to look up at which m/z a trace gas of interest is detected. Vice versa, the library also allows looking up what trace gas may have been responsible for a product ion detected in PTR-MS and SIFT-MS. Finally, the library may serve as a dataset for further research on calculating instrument sensitivity and product-ion fragmentation, improving identification and quantification of newly detectable compounds as advances in instrumentation continue. To demonstrate the utility of the library, we present a brief analysis of product-ion fragmentation. We show that oxygenated organic compounds exhibit trends in neutral loss according to their functionality, and that on average neutral losses decrease the carbon number and increase the extent of unsaturation of product ions. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Insights into the histology of planarian flatworm Phagocata gracilis based on location specific, intact lipid information provided by GCIB-ToF-SIMS imaging

Planarian flatworms are known as the masters of regeneration, re-growing an entire organism from as little as 1/279th part of their body. While the proteomics of these processes has been studied extensively, the planarian lipodome remains relatively unknown. In this study we investigate the lipid profile of planarian tissue sections with imaging Time-of-Flight – Secondary-Ion-Mass-Spectrometry (ToF-SIMS). ToF-SIMS is a label-free technique capable of gathering intact, location specific lipid information on a cellular scale. Lipid identities are confirmed using LC-MS/MS. Our data shows that different organ structures within planarians have unique lipid profiles. The 22-carbon atom poly unsaturated fatty acids (PUFAs) which occur in unusually high amounts in planarians are found to be mainly located in the testes. Additionally, we observe that planarians contain various odd numbered fatty acid species that are usually found in bacteria, localized in the reproductive and ectodermal structures of the planarian. An abundance of poorly understood ether fatty acids and ether lipids were found in unique areas in planarians as well as a new, yet unidentified class of potential lipids in planarian intestines. Identifying the location of these lipids in the planarian body provides insights into their bodily functions and, in combination with knowledge about their diet and their genome, enables drawing conclusions about planarian fatty acid processing.

Angerer, Tina B.↗

Observation of carbon fractionation in HE debris by large geometry secondary ion mass spectrometry

Detonation of high explosives (HE) is an exothermic process producing a variety of simple gaseous molecules (e.g. CO, CO 2 , N 2 , H 2 O) and solid carbon soot. The chemistry of formed carbon soot is influenced by the high pressures (P) and temperatures (T) induced by shock compression that occurs due to detonation. This can result in isotopic fractionation of the soot as the lighter 12 C is more likely to participate in reactions forming gaseous products, resulting in 13 C enriched particulate soot material. Isotopic analysis of HE soot is usually performed at the bulk level of an agglomerated sample, which gives an average value of HE derived soot and other bystander debris and can obscure trends among individual particles. To study C isotopic fractionation of HE debris at the individual particle level, we have used Large Geometry Secondary Ion Mass Spectrometry (LG-SIMS), which has the ability to deliver in-situ high precision and accuracy isotope ratios of individual particles. This allows for evaluating thousands of individual particles from HE detonations, providing isotopic data at the per particle level. HE debris particles from a variety of detonation conditions (P ranging from 25 – 85 GPa) have been measured by LG-SIMS showing a general trend of higher 13 C fractionation with increasing P.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superior Cardiac Function Via Anaplerotic Pyruvate in the Immature Swine Heart After Cardiopulmonary Bypass and Reperfusion

Pyruvate produces inotropic responses in the adult reperfused heart. Pyruvate oxidation and anaplerotic entry into the citric acid cycle (CAC) via carboxylation are linked to stimulation of contractile function. The goals of this study were to determine if these metabolic pathways operate and are maintained in the developing myocardium after reperfusion. Immature male swine (age 10-18 days) were subjected to cardiopulmonary bypass (CPB). Intracoronary infusion of [2]-13C-pyruvate (to achieve a final concentration of 8 mM) was given for 35 minutes starting either during weaning (Group I), after discontinuation (Group II) or without (Control) CPB. Hemodynamic data was collected. 13C NMR spectroscopy was used to determine the fraction of pyruvate entering the CAC via pyruvate carboxylation (PC) to total CAC entry (PC plus decarboxlyation via pyruvate dehydrogenase). Liquid chromatography-mass spectrometry was used to determine total glutamate enrichment.

59 BASIC BIOLOGICAL SCIENCES↗

Investigation of Low-Level Nitrogen in Niobium by Secondary Ion Mass Spectrometry

Understanding the improvement of the SRF cavity quality factor by low-level nitrogen addition (?N-doping?) is attracting much attention from researchers. Precise, repeatable measurement of the nitrogen profile in the parts-per-thousand to parts-per-million range is vital. Secondary Ion Mass Spectrometry (SIMS) is the approach of choice because of excellent sensitivity and depth resolution. Accurate quantitation must consider sample properties, such as surface topography and crystal structure, calibration of the instrument with reference materials, and data analysis. We report the results of a SIMS study in which polycrystal and single crystal coupons were N-doped, each accompanied by new SRF-grade niobium sheet equivalent to a single cell cavity.

Tuggle, Jay↗

2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results at Rio Blanco, Colorado

The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rio Blanco, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–21, 2015. This report documents the analytical results of the Rio Blanco annual monitoring event, the trip report, and the data validation package. The groundwater and surface water monitoring samples were shipped to the GEL Group Inc. laboratories for conventional analysis of tritium and analysis of gamma-emitting radionuclides by high-resolution gamma spectrometry. A subset of water samples collected from wells near the Rio Blanco site was also sent to GEL Group Inc. for enriched tritium analysis. All requested analyses were successfully completed. Samples were collected from a total of four onsite wells, including two that are privately owned. Samples were also collected from two additional private wells at nearby locations and from nine surface water locations. Samples were analyzed for gamma-emitting radionuclides by high-resolution gamma spectrometry, and they were analyzed for tritium using the conventional method with a detection limit on the order of 400 picocuries per liter (pCi/L). Four locations (one well and three surface locations) were analyzed using the enriched tritium method, which has a detection limit on the order of 3 pCi/L. The enriched locations included the well at the Brennan Windmill and surface locations at CER-1, CER-4, and Fawn Creek 500 feet upstream.

54 ENVIRONMENTAL SCIENCES↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics FY2022 Project Report

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques. In this first year of the project, all uranium oxide samples were synthesized and characterized using conventional analyses by the analytical chemistry laboratory. Conventional analysis methods included powder x-ray diffraction, scanning electron microscopy, impurity analysis via inductively coupled plasma mass spectrometry, and infrared spectroscopy. Impurity analysis shows a drop in boron content from UO 3 to the lowest U 3 O 8 calcination temperature, but otherwise no appreciable difference in any sample. Analysis of diffraction data shows a flip of peaks from UO 3 dominated for the 600 °C calcined sample to U 3 O 8 dominated at 700 °C and 800 °C. Analysis of scanning electron microscopy images shows that with increased calcination temperature the size distribution of particles seems to increase and broaden. Both of these last findings are in line with previously published data, though this work used significantly fewer particles to simply show similar trends instead of getting truly quantitative particle analysis. Infrared analysis similarly shows ingrowth of U 3 O 8 as calcination temperature is increased, along with depression of peaks associated with UO 3 and water. Samples were prepared for analysis at the Advanced Photon Source at beamline 1-ID. It is anticipated that analysis will occur in November of 2022. AI/ML techniques to de-noise data coming out of 1-ID during the analyses was also developed during this time using previously gathered data. Preliminary results using a self-supervision technique called Noise2Selfshow good de-noising of data. Once the uranium oxide samples are analyzed, real data will be used to test the de-noising and other AI/ML techniques that may be developed in the second year of the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry

Stable isotope ratio measurements using IRMS have been shown by LANL to be effective for tracking co-processed biogenic carbon, with results approaching that of AMS. The lower cost of an IRMS may enable deployment to refineries improving access and analysis turnaround times (≤ 2-hours), and by extension data that can allow process optimization to maximize renewable carbon in desired refinery products. This work will apply chemical separation approaches as part of the IRMS analyses, enabling biogenic carbon tracking in fuel product streams by boiling point range, by chemical class, or even by compound. This work will show IRMS to be at a minimum as reliable and comparable to AMS, by using separations to improve sensitivity at low blend ratios and enable refinery process optimization through onsite analysis.

36 MATERIALS SCIENCE↗

Evaluation of Properties for Microsample Identification

A study was conducted to determine if individual particle characteristics could be used to identify particles of interest, sub-samples, from bulk post-detonation debris. Three archived post-detonation debris samples were used for this effort. Particles from these samples were identified as active (produced fission tracks), and inactive (did not produce fission tracks), as the first defining characteristic. Morphology was the secondary characteristic to select particles for further study, i.e. spherical/non-spherical. Once particles were identified and isolated, they were characterized by optical microscopy for size in µm, number of fission tracks, morphology, transmitted light color, and reflected light color. Particles were then analyzed by scanning electron microscopy for morphology, elemental content, and compound identification. Raman spectroscopy was attempted on five particles with indeterminate results due to environmental mixing (heterogeneity) during the events of particle formation. Once all non-destructive analyses were completed all particles were analyzed by thermal ionization mass spectrometry to determine isotopic atom percents of plutonium and uranium, and an estimate of atoms of plutonium and uranium in each particle. An estimate of the ratio of uranium to plutonium was also obtained (U/Pu). Data analytics of the data from the particles showed that combining characteristics of the particles have a high probability of identifying particles of interest from bulk post-detonation debris samples. Please note that this version of the report is an abridged version of the full report (Wagnon et al. 2025) that has been edited to be appropriate for public release.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electronic drive and acquisition system for mass spectrometry

The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

Schaefer, Rembrandt Thomas↗

Trace Elemental Abundances in Calcium-Aluminum-Rich Inclusions in CV Chondrites

Introduction: Calcium-aluminum-rich inclusions (CAIs), are the first formed solids that define the age of the Solar System [1,2]. CAIs are thought to have condensed from nebular gas [3,4] within the first <1 Ma of Solar System formation [5,6]. CAIs have experienced numerous early Solar System processes including condensation, evaporation, melting, recrystallization, and aqueous alteration [e.g., 7]. The chemical, mineralogical, and textural diversity among CAIs results from a range of chemical and physical processes recorded during nebular and parent body epoch. This study aims to explore the mineralogical, textural, and chemical compositions of CAIs including the trace elemental abundances in CAI phases to determine the early Solar System processes recorded in them. Samples and Analytical Methods: We analyzed one CAI each from CV3 chondrites Northwest Africa (NWA) 5508 designated as ‘Saguaro’, and Northwest Africa (NWA) 12772 designated as ‘Hoopoe’. Back-scatter electron (BSE) images were collected using a Phenom XL scanning electron microscope (SEM) at the Lunar and Planetary Institute (LPI) and the JEOL JXA-8530F electron probe microanalyzer (EPMA) at Johnson Space Center (JSC)-NASA. Additionally, energy dispersive X-ray spectrometry (EDS) elemental maps of select areas for these samples were collected using a 15.0kV beam energy and a 40µA emission current. Using the EPMA, wavelength-dispersive X-ray spectroscopy (WDS) quantitative data were collected. In-situ trace element measurements for both CAIs were determined at JSC-NASA using a Photon Machines 193nm laser ablation system and a Thermo-Scientific Element-XR inductively coupled plasma mass spectrometer (ICP-MS). Analyses consisted of 30s ablations at 10Hz, spot sizes of 20-25µm, and a fluence of 6.0 J/cm2 for anorthite and melilite, and a 3.5 J/cm2 fluence for all other phases. NIST612 was used to correct for instrument drift, while BHVO-2g was used as a primary calibration standard. BCR-2g and in-house mineral standards were regularly measured as unknowns to ensure accuracy. Results: Saguaro is a coarse-grained CAI, ~11 x 6 mm in dimensions. Saguaro contains spinel, Al-rich pyroxene, anorthite, Mg-rich melilite, and minor perovskite in its interior and is therefore classified as a Type B CAI. Individual melilite grains shows normal compositional zoning with an Ak content ranging from ~24 to 54 with no apparent trend from the core to the edge of the CAI. The spinel appears euhedral and occurs both as clusters and as spinel palisades [8]. Two rim sequences surround most of the sample: the inner rim being a Wark-Lovering (WL) rim (~10-35 µm) containing pyroxene, spinel, and melilite (or anorthite), and the outer rim is a finer-grained, thicker (~100 µm), accretionary rim (Fig. 1). The mineral phases in Saguaro record an overall flat REE pattern with an average negative Eu anomaly in pyroxene, and an average positive Eu anomaly in anorthite and melilite respectively. Anorthite, melilite, and pyroxene have a minor depletion in Tm (Fig. 2). The Hoopoe CAI is a compact, coarse-grained ~6 × 4 mm in size. The major mineralogy includes hibonite, spinel, melilite, anorthite, and perovskite. Therefore, it is classified as a compact transitional type A and B. (?)zoning was observed in some hibonites. Individual melilite grains show both reverse and normal zoning, where the Ak content ranges from ~6- to 28. Melilite shows two distinct textures. One texture consisted of smooth melilite that appeared homogenous, while the second appeared to consist of many fine fractures. The spinel also often appears clustered. The WL-rim sequence surrounding Hoopoe is ~25 µm thick and composed of spinel, perovskite, hibonite, and melilite/anorthite. It is then partially surrounded by an outer accretionary rim (~75µm). Like before, refractory metal nuggets appeared concentrated near the WL rims. Other metal assemblages rich in Fe and Ni were also observed. All major mineral phases in Hoopoe display relatively flat REE patterns, except for varying Eu and Tm between phases (Fig. 2). There is a prominent negative Eu anomaly in perovskite and an average positive Eu anomaly in spinel, anorthite, and hibonite respectively (Fig. 2, 3). The mixed phases along the rim of the CAI also display a negative Eu anomaly, and all phases the CAI were depleted in Pb. Discussion: The CV3 CAIs analyzed in this study were classified based on their mineralogy and textures into Type A versus Type B CAIs [10]. Hibonite appears to be pseudomorphically replacing the spinel, (i.e., is hibonite in composition, but appears in the shape of spinel). Spinel palisades. The presence of spinel palisades present in Saguaro are consistent with the melting and recrystallization experienced by this CAI. Trace elemental analyses. Saguaro and Hoopoe display similar trace element patterns to each other, with both appearing generally flat, with anomalies in Eu, and Tm. Melilite and anorthite display positive Eu anomalies in both CAIs, in addition to the hibonite in Hoopoe (Fig. 2). The phases that are depleted in Eu are pyroxene and perovskite in both Saguaro and Hoopoe, respectively (Fig. 3). Given that Eu is volatile in reducing environments [11], this could possibly indicate reducing conditions at the time anorthite and melilite crystallized, with the gas they formed from containing Eu. As these CAIs continued to form, this gas as a result would become depleted in Eu. This also could be supported by the propensity of anorthite and melilite to take up Eu from its surroundings and incorporate it into their structure [12]. In addition, analyzing the assemblage of the phases in the Saguaro, melilite and anorthite (Eu enriched) often surround the pyroxene (Eu depleted) as they are crystallized. This intergrowth of phases and the proximity of the phases would support that the Eu is being incorporated into some phases, preventing it from incorporating into other. Trace elemental analyses of the CAI rims will be evaluated in more detail, as they are complicated by the transient signal being composed of a mixture of mineral phases. Broadly, however, the patterns in the rims of both CAIs are comparable to each other, and for Hoopoe, to the mixed phase patterns in the core (Fig. 3). Other studies have found that CAI rims can be depleted in Ce and Yb [13], however we did not observe these anomalies in the two CAIs discussed here. Given their similarity, the trace elemental analyses of the mixed interior (i.e. core) and rim phases could be interpreted as forming from similar, if not the same, reservoirs. The REE abundance between the rim and core of Hoopoe are also similar, indicating they may have formed from a gas of the same or similar composition. Acknowledgments: We thank the ASU Center for Meteorite Studies for loaning the samples used in this work and Tabb Prissel for his assistance with the analysis. Mouti Al-Hashimi thanks Sam Crossley and Cyrena Goodrich for their help with the LPI SEM training. This work was supported by the LPI Summer Intern Program in Planetary Science and the LPI Cooperative Agreement. References: [1] Connelly J.N. (2012) Science, 338, 651-655. [2] MacPherson G. J. (2014) Treatise on Geochem., 2, 139-179. [3] Grossman L. (1972) GCA, 36, 597-619. [4] Ebel, D.S. (2006) Meteorites and the Early Solar System II (D. S. Lauretta & H. Y. McSween, Eds.) 253-277. [5] MacPherson G. J. (2012) Earth Planet. Sci. Lett., 331-332, 43-54. [6] MacPherson G.J. (2017) GCA, 201, 65-82. [7] Krot A.N. (1995) Meteoritics & Planet. Sci., 30, 748-775. [8] Wark and Lovering (1982) GCA, 46, 2595-2607. [9] Palme H. and Jones A. (2003) Treatise on Geochemistry (H. D. Holland and K. K. Turekian Eds.), 1, 41-61. [10] Grossman L. (1980) Ann. Rev. Earth Planet. Sci., 8, 559-608. [11] Floss C. et al. (1996) GCA, 60, 1975-1997. [12] Mason B. and Martin P. M. (1974) Earth Planet. Sci. Lett., 22, 141-144. [13] Wark B. and Boynton W. V. (2001) Meteoritics & Planet. Sci., 36, 1135-1166.

X Mouti↗

The Spatial Distribution of Soluble Organic Matter and Their Relationship to Minerals in the Asteroid (162173) Ryugu

We performed in-situ analysis on a ~1 mm-sized grain A0080 returned by the Hayabusa2 spacecraft from near-Earth asteroid (162173) Ryugu to investigate the relationship of soluble organic matter (SOM) to minerals. Desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) imaging mapped more than 200 CHN, CHO, CHO–Na (sodium adducted), and CHNO soluble organic compounds. A heterogeneous spatial distribution was observed for different compound classes of SOM as well as among alkylated homologues on the sample surface. The A0080 sample showed mineralogy more like an Ivuna-type (CI) carbonaceous chondrite than other meteorites. It contained two different lithologies, which are either rich (lithology 1) or poor (lithology 2) in magnetite, pyrrhotite, and dolomite. CHN compounds were more concentrated in lithology 1 than in lithology 2; on the other hand, CHO, CHO–Na, and CHNO compounds were distributed in both lithologies. Such different spatial distribution of SOM is likely the result of interaction of the SOM with minerals, during precipitation of the SOM via fluid activity, or could be due to difference in transportation efficiencies of SOMs in aqueous fluid. Organic-related ions measured by time-of-flight secondary ion mass spectrometry (ToF–SIMS) did not coincide with the spatial distribution revealed by DESI-HRMS imaging. This result may be because the different ionization mechanism between DESI and SIMS, or indicate that the ToF–SIMS data would be mainly derived from methanol-insoluble organic matter in A0080. In the Orgueil meteorite, such relationship between altered minerals and SOM distributions was not observed by DESI-HRMS analysis and field-emission scanning electron microscopy, which would result from differences of SOM formation processes and sequent alteration process on the parent bodies or even on the Earth. Alkylated homologues of CHN compounds were identified in A0080 by DESI-HRMS imaging as observed in the Murchison meteorite, but not from the Orgueil meteorite. These compounds with a large C number were enriched in Murchison fragments with abundant carbonate grains. In contrast, such relationship was not observed in A0080, implying different formation or growth mechanisms for the alkylated CHN compounds by interaction with fluid and minerals on the Murchison parent body and asteroid Ryugu.

Ryugu↗

Interpretable Machine Learning for Molecular Biosignatures: a Novel Single-Sample Feature Importance Method That Is Sensitive To Statistical Interactions

Isotope ratio mass spectrometry (IRMS) of volatiles (e.g., CO 2 ) promises to be a powerful tool for potential biosignature detection for future missions to ocean worlds (OW) such as Europa and Enceladus. Machine learning (ML) methods for IRMS data could enable science autonomy by onboard prediction of seawater chemistry and biosignature presence. However, ML models are likely to be complex and involve statistical interactions between features (variables), which can make predictions seem opaque and enigmatic. For ML predictions as significant as extraterrestrial biosignatures, we must place extraordinary confidence in models. It is therefore essential that these models make interpretable predictions (i.e., human-understandable) and include false-prediction diagnostics. We achieve high accuracy and interpretability in ML biosignature and seawater chemistry models for OW through a nearest-neighbors feature selection tool that detects statistical interactions between predictors, constructs interaction networks for visualization of selected features working together to make a prediction, and reports single-sample feature importance scores for false-detection diagnostics. Here we develop a novel single-sample nearest-neighbors projected distance regression(ssNPDR) feature selection method that improves upon existing single-sample algorithms through the inclusion of statistical interactions while providing false-prediction diagnostics for ML models.

geochemistry↗

A Laser-Based Method for On-Site Analysis of UF6 at Enrichment Plants

The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DA samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.

LAARS↗