Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “soft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Determination of radial location of rotating magnetic islands by use of poloidal soft x-ray detector arrays in the STOR-M tokamak

A technique is presented for determining the radial location of the rotating magnetic islands in the STOR-M tokamak by use of soft x-ray (SXR) detector arrays. The location is determined by examining the difference in the integrated SXR emission intensities through two adjacent lines of sight. A model for calculating dependence of the line integrated SXR emission intensity on the radius, the mode numbers and the magnetic island geometry, has been developed. The SXR difference signal shows phase inversion when the impact parameter of the line of sight sweeps across the magnetic islands. Experimentally, the difference SXR signals significantly reduce noise and suppress the influence of background plasma fluctuations through common mode rejection when a dominant mode exists in the STOR-M tokamak. The radial locations of the m= 2 magnetic islands have been determined under several experimental conditions in the STOR-M discharges. With the decrease in the tokamak discharge current and thus the increase of the safety factor at the edge, the radial location of the m= 2 magnetic islands has been found to move radially inward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

Development of Computer Tomography System for the Soft X-ray Microscope at Ritsumeikan University

A synchrotron-based full-field imaging soft x-ray microscope was tuned appropriately to perform computer tomography. The contrast and focal depth of the optical system were evaluated by using a Fresnel zone plate as a test object of variable spatial frequency. A focal depth of 15 {mu}m was obtained at the spatial frequency of 4.3 {mu}m{sup -1} according to Rayleigh's criterion. As a first trial of three-dimensional observation using this system, the cerebral cortex of the brain of a mouse, trimmed to a columnar shape by focused ion beam milling, was studied using a wavelength of 1.87-nm.

43 PARTICLE ACCELERATORS↗

The Soft X-ray Spectromicroscopy Beamline at SSRF

Commissioning of the soft x-ray spectromicroscopy beanmline at SSRF was formally started on Dec 26, 2008. Beamline performance has reached or surpassed the designing goals according to the measurements by domestic experts, especially for its high energy resolution and high spatial resolution. Since its first operation by users on May 6, 2009, tens of experiments have been conducted, and some preliminary exciting results have been acquired.

07 ISOTOPE AND RADIATION SOURCES↗

Aplanatic Three-Mirror Objective for High-Magnification Soft X-Ray Microscopy

An innovative solution for high-magnification microscopy, based on attaching afocal optics for focal length reduction, is proposed. The solution, consisting of three spherical mirrors, allows one to enhance a magnification of a laboratory based soft x-ray microscope over 1000x, where movies with diffraction-limited resolution can be observed with an x-ray CCD. The design example, having a numerical aperture of 0.25, was successfully demonstrated both a high magnification and a large field of view.

07 ISOTOPE AND RADIATION SOURCES↗

Soft X-ray Microscopy of Green Cements

The present status of the cement and concrete industry is not sustainable. The production of Portland cement is responsible for 7% of the CO{sub 2} emissions in the world and existing reinforced concrete infrastructure is deteriorating at a fast pace. The change in the existing technology requires new developments in our understanding of the nanostructure of hydration products and the complex deterioration reactions. We have been developing an elaborate research program to advance the existing cement and concrete science by characterizing its nanostructure by synchrotron radiation. A new generation of green cements is being studied using high-resolution soft x-ray microscopy at the nano-level.

36 MATERIALS SCIENCE↗

Electron-hole correlation effects in core-level spectroscopy probed by the resonant inelastic soft x-ray scattering map of C{sub 60}

We have employed a unique spectroscopic approach, a resonant inelastic soft x-ray scattering (RIXS) map, to identify and separate electron-hole correlation effects in core-level spectroscopy. With this approach, we are able to derive a comprehensive picture of the electronic structure, separating ground state properties (such as the HOMO-LUMO separation) from excited state properties (such as the C 1s core-exciton binding energy of C{sub 60}). In particular, our approach allows us to determine the difference between core- and valence exciton binding energies in C{sub 60}[0.5 ({+-}0.2) eV]. Furthermore, the RIXS map gives detailed insight into the symmetries of the intermediate and final states of the RIXS process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft x-ray array system with variable filters for the DIII-D tokamak

Recent upgrades to the soft x-ray (SXR) array system on the DIII-D tokamak are described. The system consists of two 32-channel arrays at one toroidal location and three toroidally distributed 12-channel arrays. The 32-channel arrays have been completely rebuilt to allow the switching of SXR filters without breaking vacuum. The 12-channel arrays have had upgrades performed to detectors, view slits, and data acquisition. Absolute extreme ultraviolet (AXUV) photodiodes are used as detectors in all arrays, allowing detection of photons ranging in energy from 2 eV to 10 keV. In the fixed-filter arrays, 127 {mu}m Be filters are used. In the variable-filter arrays, filter wheels are used to switch between five different possible pinhole/filter combinations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved soft x-ray absorption setup using multi-bunch operation modes at synchrotrons

Here, we report on a novel experimental apparatus for performing time-resolved soft x-ray absorption spectroscopy in the sub-ns time scale using non-hybrid multi-bunch mode synchrotron radiation. The present setup is based on a variable repetition rate Ti:sapphire laser (pump pulse) synchronized with the {approx}500 MHz x-ray synchrotron radiation bunches and on a detection system that discriminates and singles out the significant x-ray photon pulses by means of a custom made photon counting unit. The whole setup has been validated by measuring the time evolution of the L{sub 3} absorption edge during the melting and the solidification of a Ge single crystal irradiated by an intense ultrafast laser pulse. These results pave the way for performing synchrotron time-resolved experiments in the sub-ns time domain with variable repetition rate exploiting the full flux of the synchrotron radiation.

43 PARTICLE ACCELERATORS↗

Ultrahigh resolution soft x-ray emission spectrometer at BL07LSU in SPring-8

An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution {Delta}E < 100 meV and/or an E/{Delta}E{approx} 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 {mu}m) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/{Delta}E= 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.

43 PARTICLE ACCELERATORS↗

Development of soft x-ray time-resolved photoemission spectroscopy system with a two-dimensional angle-resolved time-of-flight analyzer at SPring-8 BL07LSU

We have developed a soft x-ray time-resolved photoemission spectroscopy system using synchrotron radiation (SR) at SPring-8 BL07LSU and an ultrashort pulse laser system. Two-dimensional angle-resolved measurements were performed with a time-of-flight-type analyzer. The photoemission spectroscopy system is synchronized to light pulses of SR and laser using a time control unit. The performance of the instrument is demonstrated by mapping the band structure of a Si(111) crystal over the surface Brillouin zones and observing relaxation of the surface photo-voltage effect using the pump (laser) and probe (SR) method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elimination of higher-order diffraction using zigzag transmission grating in soft x-ray region

We present a realization of the sinusoidal transmission function using a series of zigzag-profiled strips where the transmission takes on the binary values 0 and 1 in a two-dimensional distribution. A zigzag transmission grating of 1000 line/mm has been fabricated and demonstrated on the soft x-ray beam of synchrotron radiation. The axial single-order diffraction indicates that the zigzag transmission grating is adequate for spectroscopic application.

43 PARTICLE ACCELERATORS↗

Nuclear dynamics and spectator effects in resonant inelastic soft x-ray scattering of gas-phase water molecules

The electronic structure of gas-phase H{sub 2}O and D{sub 2}O molecules has been investigated using resonant inelastic soft x-ray scattering (RIXS). We observe spectator shifts for all valence orbitals when exciting into the lowest three absorption resonances. Strong changes of the relative valence orbital emission intensities are found when exciting into the different absorption resonances, which can be related to the angular anisotropy of the RIXS process. Furthermore, excitation into the 4a{sub 1} resonance leads to nuclear dynamics on the time scale of the RIXS process; we find evidence for vibrational coupling and molecular dissociation in both, the spectator and the participant emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of multilayer mirror for harmonic analysis in soft X-ray region

Order contamination in soft x-ray beamline is a severe problem which poses difficulty in various analysis techniques. Generally grating analyzer is used to estimate the higher order contribution where poor knowledge of wall and land roughness contribution makes it difficult to get theoretical fit and so analysis gives qualitative estimation only. Here we demonstrate the application of multilayer mirror for accurate determination of order contamination in Toroidal grating monochromator (TGM) at reflectivity beamline of Indus-1. We used a Mo/Si multilayer of d{approx}100Aa period to quantify 2{sup nd} and 3{sup rd} order composition to identify order contamination below 0.5% or better.

43 PARTICLE ACCELERATORS↗

Plasma ion source for in situ ion bombardment in a soft x-ray magnetic scattering diffractometer

A new plasma ion source for in situ keV He ion bombardment of solid state samples or thin films was designed and built for ion fluences between 1 x 10{sup 12} and 1 x 10{sup 17} ions/cm{sup 2}. The system was designed to be mounted to different diffraction chambers for soft x-ray resonant magnetic scattering. Without breaking the vacuum due to He-ion bombardment, structural and magnetic modifications of the samples can be studied in situ and element specifically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas

Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray tomography for real-time applications: present status at Tore Supra and possible future developments

This paper is focused on the soft x-ray (SXR) tomography system setup at Tore Supra (DTOMOX) and the recent developments made to automatically get precise information about plasma features from inverted data. The first part describes the main aspects of the tomographic inversion optimization process. Several observations are made using this new tool and a set of shape factors is defined to help characterizing the emissivity field in a real-time perspective. The second part presents a detailed off-line analysis comparing the positions of the magnetic axis obtained from a magnetic equilibrium solver, and the maximum of the reconstructed emissivity field for ohmic and heated pulses. A systematic discrepancy of about 5 cm is found in both cases and it is shown that this discrepancy increases during sawtooth crashes. Finally, evidence of radially localized tungsten accumulation with an in-out asymmetry during a lower hybrid current drive pulse is provided to illustrate the DTOMOX capabilities for a precise observation of local phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact 'diode-based' multi-energy soft x-ray diagnostic for NSTX

A novel and compact, diode-based, multi-energy soft x-ray (ME-SXR) diagnostic has been developed for the National Spherical Tokamak Experiment. The new edge ME-SXR system tested on NSTX consists of a set of vertically stacked diode arrays, each viewing the plasma tangentially through independent pinholes and filters providing an overlapping view of the plasma midplane which allows simultaneous SXR measurements with coarse sub-sampling of the x-ray spectrum. Using computed x-ray spectral emission data, combinations of filters can provide fast (>10 kHz) measurements of changes in the electron temperature and density profiles providing a method to 'fill-in' the gaps of the multi-point Thomson scattering system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗