Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position uncertainties, and marker displacement. Results: The sensor positions and the limit for the CWL condition were measured with excellent reproducibility (standard deviation ≤ 0.39 mm). The ghost marker detection algorithm had perfect detection accuracy for both the jig (1544 samples) and the anthropomorphic phantom (2045 samples). Pattern matching was successful for all samples from both phantoms as well as the 40 patient marker patterns. Conclusions: The authors proposed a simple model to explain the origin of ghost markers and identified the CWL condition as the necessary condition for ghost marker occurrence. The retrospective ghost marker detection and elimination algorithms guarantee complete ghost marker elimination while providing the users with maximum flexibility in selecting the number of markers and their configuration to meet their clinic needs.

60 APPLIED LIFE SCIENCES↗

Field data collection of miscellaneous electrical loads in Northern California: Initial results

This report describes efforts to measure energy use of miscellaneous electrical loads (MELs) in 880 San Francisco Bay Area homes during the summer of 2012. Ten regions were selected for metering: Antioch, Berkeley, Fremont, Livermore, Marin County (San Rafael, Novato, Fairfax, and Mill Valley), Oakland/Emeryville, Pleasanton, Richmond, San Leandro, and Union City. The project focused on three major categories of devices: entertainment (game consoles, set-top boxes, televisions and video players), home office (computers, monitors and network equipment), and kitchen plug-loads (coffee/espresso makers, microwave ovens/toaster ovens/toasters, rice/slow cookers and wine chillers). These categories were important to meter because they either dominated the estimated overall energy use of MELs, are rapidly changing, or there are very little energy consumption data published. A total of 1,176 energy meters and 143 other sensors were deployed, and 90% of these meters and sensors were retrieved. After data cleaning, we obtained 711 valid device energy use measurements, which were used to estimate, for a number of device subcategories, the average time spent in high power, low power and “off” modes, the average energy use in each mode, and the average overall energy use. Consistent with observations made in previous studies, we find on average that information technology (IT) devices (home entertainment and home office equipment) consume more energy (15.0 and 13.0 W, respectively) than non-IT devices (kitchen plug-loads; 4.9 W). Opportunities for energy savings were identified in almost every device category, based on the time spent in various modes and/or the power levels consumed in those modes. Future reports will analyze the collected data in detail by device category and compare results to those obtained from prior studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tamper-Indicating Enclosures with Visually Obvious Tamper Response (Final Project Report)

Sandia National Laboratories is developing a new method for detecting penetration of tamper - indicating enclosures (TIEs). This method incorporates the use of "bleeding" materials (analogous to visually obvious, colorful bruised skin that doesn't heal) into the design of TIEs. As designed, it will allow inspectors to use simple visual observation to detect attempts to penetrate the external surfaces of a TIE, without providing adversaries the ability to repair damage. A material of this type can enhance tamper indication of current TIEs used to support treaty verification regimes. Current TIE inspections are time - consuming and rely on subjective visual assessment by an inspector, equipment such as eddy current or camera devices, or involve approaches that may be limited due to application environment. The complexities and requirements that volumetric sealing methods (or TIEs) must address are: (1) enclosures that are non - standard in size/shape; (2) enclosures that may be inspectorate - or facility - owned; (3) finding tamper attempts that are difficult and time consuming for an inspector to locate; (4) enclosures that are reliable and durable enough to survive the conditions that exist in the operating environment (including facility handling); and (5) methods that prevent adversaries from repairing penetrations. Early project R&D [1] focused on encapsulated transition metals. Due to the challenges associated with the transition metal - based approach, a mitigation approach was investigated resulting in two separate research paths — one that involves fabricating custom TIE molds that meet the specific (size and shape) needs of safeguards equipment a nd one that can be deployed as a sprayed on or painted coating to an existing TIE or surface. The "custom mold" approach is based on creating thin layers of materials that , when penetrated, expose an inner material to O 2 which causes an irreversible color change. The "in-situ coating" approach is based on applying a sensor solution containing color changing microcapsules that bleed when the microcapsule is ruptured. The anticipated benefits of this work are passive, flexible, scalable, robust , cost-effective TIEs with visually obvious responses to tamper attempts. This provides more efficient and effective monitoring , as inspectors will require little or no additional equipment and will be able to detect tamper without extensive time - consuming visual examination. Applications include custom TIEs (cabinets , equipment enclosures or seal bodies ), or spray-coating/painting onto facility-owned items, walls or structures, or circuit boards. The paper describes research and testing completed to-date on the method and integration of select system components.

36 MATERIALS SCIENCE↗

Nanoparticle-Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve AgentsOrganophosphate Pesticides and Nerve Agents

A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE) adducts, which is a potential exposure biomarker for organophosphate pesticides (OP) and chemical warfare nerve agent exposures. Zirconia nanoparticles (ZrO2 NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to track the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO2 NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as a model OP insecticide to prepare the phosphorylated AChE adduct to demonstrate the proof of principle for this sensor technology. The paraoxon-AChE adduct was characterized by Fourier Transform Infrared Spectrum, and the binding affinity of anti-AChE to the paraoxon-AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO2 NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM paraoxon-AChE, and the limit of detection is estimated to be 8 pM. This new nanoparticle-based electrochemical immunosensor thus provides a sensitive and quantitative tool for biomonitoring exposure to OP pesticides and nerve agents.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High resolution dual detector volume-of-interest cone beam breast CT - Demonstration with a bench top system

Purpose: In this study, we used a small field high resolution detector in conjunction with a full field flat panel detector to implement and investigate the dual detector volume-of-interest (VOI) cone beam breast computed tomography (CBCT) technique on a bench-top system. The potential of using this technique to image small calcifications without increasing the overall dose to the breast was demonstrated. Significant reduction of scatter components in the high resolution projection image data of the VOI was also shown. Methods: With the regular flat panel based CBCT technique, exposures were made at 80 kVp to generate an air kerma of 6 mGys at the isocenter. With the dual detector VOI CBCT technique, a high resolution small field CMOS detector was used to scan a cylindrical VOI (2.5 cm in diameter and height, 4.5 cm off-center) with collimated x-rays at four times of regular exposure level. A flat panel detector was used for full field scan with low x-ray exposures at half of the regular exposure level. The low exposure full field image data were used to fill in the truncated space in the VOI scan data and generate a complete projection image set. The Feldkamp-Davis-Kress (FDK) filtered backprojection algorithm was used to reconstruct high resolution images for the VOI. Two scanning techniques, one breast centered and the other VOI centered, were implemented and investigated. Paraffin cylinders with embedded thin aluminum (Al) wires were imaged and used in conjunction with optically stimulated luminescence (OSL) dose measurements to demonstrate the ability of this technique to image small calcifications without increasing the mean glandular dose (MGD). Results: Using exposures that produce an air kerma of 6 mGys at the isocenter, the regular CBCT technique was able to resolve the cross-sections of Al wires as thin as 254 {mu}m in diameter in the phantom. For the specific VOI studied, by increasing the exposure level by a factor of 4 for the VOI scan and reducing the exposure level by a factor of 2 for the full filed scan, the dual-detector CBCT technique was able to resolve the cross-sections of Al wires as thin as 152 {mu}m in diameter. The CNR evaluated for the entire Al wire cross-section was found to be improved from 5.5 in regular CBCT to 14.4 and 16.8 with the breast centered and VOI centered scanning techniques, respectively. Even inside VOI center, the VOI scan resulted in significant dose saving with the dose reduced by a factor of 1.6 at the VOI center. Dose saving outside the VOI was substantial with the dose reduced by a factor of 7.3 and 7.8 at the breast center for the breast centered and VOI centered scans, respectively, when compared to full field scan at the same exposure level. The differences between the two dual detector techniques in terms of dose saving and scatter reduction were small with VOI scan at 4x exposure level and full field scan at 0.5x exposure level. The MGDs were only 94% of that from the regular CBCT scan. Conclusions: For the specific VOI studied, the dual detector VOI CBCT technique has the potential to provide high quality images inside the VOI with MGD similar to or even lower than that of full field breast CBCT. It was also found that our results were compromised by the use of inadequate detectors for the VOI scan. An appropriately selected detector would better optimize the image quality improvement that can be achieved with the VOI CBCT technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus and method for selectively channeling a fluid

An apparatus for selectively channeling a high temperature fluid without chemically reacting with the fluid. The apparatus includes an inlet and a membrane positioned adjacent to the inlet, each composed of a chemically inert material. The membrane is formed by compressive preloading techniques. The apparatus further includes a seat disposed on the inlet adjacent to the membrane. The seat is composed of a heat resistant and chemically inert material. Operation of the apparatus requires that the temperature of the fluid remains below the chemical characteristic melting point of the seat. The apparatus further includes an actuator coupled to the membrane for rendering the membrane in an open and a closed position with respect to the seat. Specifically, the actuator supplies a load in the normal direction to the membrane to selectively engage the membrane in a plurality of predetermined configurations. Operatively, the apparatus receives the fluid at the inlet. The fluid is received at a high temperature and is directed from the inlet to the membrane. In the closed position, the actuator engages the membrane to prevent the fluid from flowing from the inlet between the membrane and the seat. Alternatively, in the open position, the actuator engages the membrane to permit fluid flow from the inlet between the membrane and the seat to at least one outlet provided by the apparatus. In one exemplary embodiment, the fluid may be discharged from the at least one outlet to a sensor in fluid communication with the at least one outlet. Accordingly, the sensor may measure the fluid channeled through the heat resistant and chemically inert environment provided by the apparatus.

47 OTHER INSTRUMENTATION↗

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitive and Selective NH3 Monitoring at Room Temperature Using ZnO Ceramic Nanofibers Decorated with Poly(styrene sulfonate)

Ammonia (NH3) gas is a prominent air pollutant that is frequently found in industrial and livestock production environments. Due to the importance in controlling pollution and protecting public health, the development of new platforms for sensing NH3 at room temperature has attracted great attention. In this study, a sensitive NH3 gas device with enhanced selectivity is developed based on zinc oxide nanofibers (ZnO NFs) decorated with poly(styrene sulfonate) (PSS) and operated at room temperature. ZnO NFs were prepared by electrospinning followed by calcination at 500 °C for 3 h. The electrospun ZnO NFs are characterized to evaluate the properties of the as-prepared sensing materials. The loading of PSS to prepare ZnO NFs/PSS composite is also optimized based on the best sensing performance. Under the optimal composition, ZnO NFs/PSS displays rapid, reversible, and sensitive response upon NH3 exposure at room temperature. The device shows a dynamic linear range up to 100 ppm and a limit of detection of 3.22 ppm and enhanced selectivity toward NH3 in synthetic air, against NO2 and CO, compared to pure ZnO NFs. Additionally, a sensing mechanism is proposed to illustrate the sensing performance using ZnO NFs/PSS composite. Therefore, this study provides a simple methodology to design a sensitive platform for NH3 monitoring at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing Sensor Fusion and Multimodal Chemometric Models for Monitoring U(VI) in Complex Environments Representative of Irradiated Nuclear Fuel

Optical sensors and chemometric models were leveraged for the quantification of uranium(VI) (0–100 μg mL –1 ), europium (0–150 μg mL –1 ), samarium (0–250 μg mL –1 ), praseodymium (0–350 μg mL –1 ), neodymium (0–1000 μg mL –1 ), and HNO 3 (2–4 M) with varying corrosion product (iron, nickel, and chromium) levels using laser fluorescence, Raman scattering, and ultraviolet–visible–near-infrared absorption spectra. In this paper, an efficient approach to developing and evaluating tens of thousands of partial least-squares regression (PLSR) models, built from fused optical spectra or multimodal acquisitions, is discussed. Each PLSR model was optimized with unique preprocessing combinations, and features were selected using genetic algorithm filters. The 7-factor D-optimal design training set contained just 55 samples to minimize the number of samples. The performance of PLSR models was evaluated by using an automated latent variable selection script. PLS1 regression models tailored to each species outperformed a global PLS2 model. PLS1 models built using fused spectra data and a multimodal (i.e., analyzed separately) approach yielded similar information, resulting in percent root-mean-square error of prediction values of 0.9–5.7% for the seven factors. Further, the optical techniques and data processing strategies established in this study allow for the direct analysis of numerous species without measuring luminescence lifetimes or relying on a standard addition approach, making it optimal for near-real-time, in situ measurements. Nuclear reactor modeling helped bound training set conditions and identified elemental ratios of lanthanide fission products to characterize the burnup of irradiated nuclear fuel. Leveraging fluorescence, spectrophotometry, experimental design, and chemometrics can enable the remote quantification and characterization of complex systems with numerous species, monitor system performance, help identify the source of materials, and enable rapid high-throughput experiments in a variety of industrial processes and fundamental studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanostructured Bulk Thermoelectric Generator for Efficient Power Harvesting for Self-powered Sensor Networks

The objective of this Nuclear Energy Enabling Technology research project is to develop high-efficiency and reliable thermoelectric generators for self-powered wireless sensors nodes utilizing thermal energy from nuclear plant or fuel cycle. The power harvesting technology has crosscutting significance to address critical technology gaps in monitoring nuclear plants and fuel cycle. The outcomes of the project will lead to significant advancement in sensors and instrumentation technology, reducing cost, improving monitoring reliability and therefore enhancing safety. The self-powered wireless sensor networks could support the long-term safe and economical operation of all the reactor designs and fuel cycle concepts, as well as spent fuel storage and many other nuclear science and engineering applications. The research is based on recent breakthroughs in high-performance nanostructured bulk (nanobulk) thermoelectric materials that enable high-efficiency direct heat-to-electricity conversion over a wide temperature range. The nanobulk thermoelectric materials that the research team at Boise State University and University of Houston has developed yield up to a 50% increase in the thermoelectric figure of merit, ZT, compared with state-of-the-art bulk counterparts. This report focuses on the selection of optimal thermoelectric materials for this project. The team has performed extensive study on two thermoelectric materials systems, i.e. the half-Heusler materials, and the Bismuth-Telluride materials. The report contains our recent research results on the fabrication, characterization and thermoelectric property measurements of these two materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of the cryogenic system of AEgIS at CERN

The AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment is located at the antiproton decelerator complex of CERN. The main goal of the experiment is to perform the first direct measurement of the Earth’s gravitational acceleration on antihydrogen atoms within 1% precision. The antihydrogen is produced in a cylindrical Penning trap by combining antiprotons with positrons. To reach the precision of 1%, the antihydrogen has to be cooled to 100 mK to reduce its random velocity. A dilution refrigerator is selected to deliver the necessary cooling capacity of 100 μW at 50 mK. The AEgIS cryogenic system basically consists of cryostats for a 1-T and for a 5-T superconducting magnet, a central region cryostat, a dilution refrigerator cryostat and a measurement cryostat with a Moiré deflectometer to measure the gravitational acceleration. In autumn 2012, the 1-T cryostat, 5-T cryostat and central region cryostat were assembled and commissioned. The apparatus is cooled down in eight days using 2500 L of liquid helium and liquid nitrogen. During operation, the average consumption of liquid helium is 150 L⋅day{sup −1} and of liquid nitrogen 5 L⋅day{sup −1}. The temperature sensors at the Penning traps measured 12 K to 18 K, which is higher than expected. Simulations show that this is caused by a bad thermalization of the trap wiring. The implementation of the sub-kelvin region is foreseen for mid-2015. The antihydrogen will be cooled down to 100 mK in an ultra-cold trap consisting of multiple high-voltage electrodes made of sapphire with gold plated electrode sectors.

43 PARTICLE ACCELERATORS↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays: Report 3

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3 of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic measurement functions plus electronic functional testing (power dissipation, voltage offset changes, noise variations, etc.). This suite will be developed as part of this task.

42 ENGINEERING↗

High‐Asymmetry Metasurface: A New Solution for Terahertz Resonance via Active Learning‐Augmented Diffusion Model

Terahertz (THz) metamaterials with high‐figure‐of‐merit (high‐FoM) performance resonance are essential for advancing sensors, detectors, and imagers. Conventional designs focus on symmetric or low‐asymmetry geometric structures, leaving high‐asymmetry designs largely unexplored due to the inefficiency of trial‐and‐error‐based rational design. Recent deep learning techniques offer automation and acceleration but are constrained by the need for large datasets inherent to their data‐driven nature. Here, a novel prior knowledge‐guided generative model augmented by a physics‐constrained active learning mechanism to design high‐asymmetry metamaterials. An advanced diffusion model learns features from a small set of classical structures with high‐FoM THz resonance and generates new high‐asymmetry structures. To mitigate the limited number of classical structures, the generated high‐asymmetry structures are actively selected and integrated into the initial training dataset based on their physical characteristics. Experimental results demonstrate the superior resonance performance of the generated high‐asymmetry metamaterials over classical designs, exhibiting improvements exceeding 30% in key resonance metrics. Remarkably, this performance is attained using only 68 classical structures as the initial training dataset, significantly reducing the data requirements for deep learning‐based metamaterial design. The proposed scheme for generating high‐asymmetry structures provides a new effective and efficient solution for high‐FoM resonance, expanding applications in high‐sensitivity THz metadevices.

diffusion model↗

Safer and optimized vulnerability scanning for operational technology through integrated and automated passive monitoring and active scanning

Vulnerability scanning of embedded sensors and controllers have a history of causing disruption and malfunction within operation technology environments. Traditional information technology vulnerability scanning generally consists of blunt exercising all or a large population of test conditions to understand how equipment responds. Often the large number and varied conditions of the tests are too much for embedded systems to handle. This paper presents a methodology and framework for integrating passive monitoring and active scanning techniques to optimize the type and amount of necessary active communication tests while achieving acceptable levels of device and vulnerability discovery. Bayesian probability and networks are leveraged for inference to drive the automation of the scanning actions to achieve confidence in discovery. Through inference, selecting the optimal active scans with the least risk and highest confidence impact is possible, thereby eliminating unnecessary scans with uncertain effects. Results of experimenting with real power systems and the following probabilities are provided.

Key Management, ICS, SCADA, Authentication↗

Simulation and laboratory test results of 3D CMS pixel detectors for HL-LHC

The CMS pixel detector is the innermost tracking device at the LHC, reconstructing interaction vertices and charged particle trajectories. The current planar sensors located in the innermost layer of the pixel detector will be exposed to very high fluences which will degrade their performances. As a possible replacement for planar pixel sensors in the High Luminosity-LHC (HL-LHC), 3D silicon technology is under consideration due to its expected good performance in harsh radiation environments. Studies are also in progress for using 3D silicon pixel detectors in near-beam proton spectrometers at the LHC. Deep Reactive Ion Etching (DRIE) plays a key role in fabricating 3D silicon detectors in which readout and ohmic electrodes are processed through the silicon substrate instead of being implanted on the silicon surface. 3D pixel devices considered in this study were processed at FBK (Trento, Italy), bump bonded to the CMS pixel readout chip, and characterized in the laboratory. Numerical simulations were also carried out. We report on selected results from laboratory measurements and TCAD simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geobacter strains that use alternate organic compounds, methods of making, and methods of use thereof

In preferred embodiments, the present invention provides new isolated strains of a Geobacter species that are capable of using a carbon source that is selected from C.sub.3 to C.sub.12 organic compounds selected from pyruvate or metabolic precursors of pyruvate as an electron donor in metabolism and in subsequent energy production. The wild type strain of the microorganisms has been shown to be unable to use these C.sub.3 to C.sub.12 organic compounds as electron donors. The inventive strains of microorganisms are useful for improving bioremediation applications, including in situ bioremediation (including uranium bioremediation and halogenated solvent bioremediation), microbial fuel cells, power generation from small and large-scale waste facilities (e.g., biomass waste from dairy, agriculture, food processing, brewery, or vintner industries, etc.) using microbial fuel cells, and other applications of microbial fuel cells, including, but not limited to, improved electrical power supplies for environmental sensors, electronic devices, and electric vehicles.

09 BIOMASS FUELS↗

Comment on "Tunable generation and adsorption of energetic compounds in the vapor phase at trace levels: A tool for testing and developing sensitive and selective substrates for explosive detection"

The evaluation of developed technologies and research on new detection approaches require the ability to generate explosive vapors in the gas phase. In this correspondence, the authors comment on a technical note describing a vaopr generator, discuss safety issues associated with explosives for vapor generators, and provide a concise review of vapor generators for explosive compounds. Approaches to measuring or monitoring the output of a vapor generators are also discussed.

2,4-DNT↗

Enhancing Analytical Performance of (Mg,Fe)3O4/Glassy Carbon Electrodes by Tailoring Chemical Composition of (Mg,Fe)3O4 Nanoparticles

A series of MgxFe3-xO{sup 4} (x = 0-1) nanoparticles was synthesized in order to prepare novel MgxFe3-xO{sup 4}/glassy carbon modified electrodes. Effects of magnesium content (x) on the analytical performance of the modified electrodes in the detection of gallic acid were evaluated. It was found that magnesium concentration and crystallite/particle size of the prepared nanoparticles play significant roles in the sensing properties of modified electrodes. The increase of magnesium concentration up to the value of x = 0.4 in MgxFe3-xO{sup 4}/glassy carbon paste was accompanied by an increase of the corresponding oxidation current of gallic acid. However, further growth of x value caused decline of the obtained oxidation current. An electroanalytical procedure was established, and the analytical performance of the proposed Mg0.4Fe2.6O{sup }4#/glassy carbon paste electrode was monitored using previously optimized experimental conditions. A working linear range from 1-39 µM gallic acid was obtained with detection limit of 0.29 µM. According to these results, the developed procedure can be applied for detection of low concentrations of gallic acid with satisfactory selectivity in the presence of some common naturally occurring compounds. Experimental results indicate that the developed procedure could be a novel approach in the detection of antioxidant, overcoming some known disadvantages such as passivation, and could be a promising replacement for sophisticated chromatographic methods.

60 APPLIED LIFE SCIENCES↗