Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Engineering sensitivity and specificity of AraC-based biosensors responsive to triacetic acid lactone and orsellinic acid

Abstract We previously described the design of triacetic acid lactone (TAL) biosensor ‘AraC-TAL1’, based on the AraC regulatory protein. Although useful as a tool to screen for enhanced TAL biosynthesis, this variant shows elevated background (leaky) expression, poor sensitivity and relaxed inducer specificity, including responsiveness to orsellinic acid (OA). More sensitive biosensors specific to either TAL or OA can aid in the study and engineering of polyketide synthases that produce these and similar compounds. In this work, we employed a TetA-based dual-selection to isolate new TAL-responsive AraC variants showing reduced background expression and improved TAL sensitivity. To improve TAL specificity, OA was included as a ‘decoy’ ligand during negative selection, resulting in the isolation of a TAL biosensor that is inhibited by OA. Finally, to engineer OA-specific AraC variants, the iterative protein redesign and optimization computational framework was employed, followed by 2 rounds of directed evolution, resulting in a biosensor with 24-fold improved OA/TAL specificity, relative to AraC-TAL1.

Wang, Zhiqing↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

Demonstration of x-ray fluorescence spectroscopy as a sensitive temperature diagnostic for high-energy-density physics experiments

We present the use of x-ray fluorescence spectroscopy (XFS) to a sensitive temperature diagnostic in shocked foams at temperatures of 30–75 eV. Cobalt-doped foams were shock compressed using a planar drive at the OMEGA laser facility and photo-pumped with a Zn He⁢𝛼 x-ray source. Analysis of the resulting cobalt 𝐾⁢𝛽 x-ray fluorescence spectra using collisional radiative codes allows the temperature to be determined in the shocked foams. Furthermore, this method provides a sensitive and robust technique to determine temperatures in high-energy-density physics experiments in the tens of electronvolts temperature range. In these experiments, we find that radiation hydrodynamic simulations predict a lower temperature in the shocked foams compared to analysis of the XFS data using collisional radiative models. Although additional experiments with an independent temperature diagnostic to absolutely calibrate XFS spectra for these conditions will be required to resolve this discrepancy, these results demonstrate the excellent temperature sensitivity of XFS spectra for high-energy-density physics experiments.

Atomic spectra↗

Effective electric field: Quantifying the sensitivity of searches for new -odd physics with EuCl 3 ∙ 6H 2 O

Laboratory-scale precision experiments are a promising approach to searching for physics beyond the standard model. Noncentrosymmetric solids offer favorable statistical sensitivity for efforts that search for new fields, whose interactions violate the discrete parity and time-reversal symmetries. One example is the cosmic axion spin precession experiment (CASPEr), which can be sensitive to the defining interaction of the quantum chromodynamics (QCD) axion dark matter with gluons in atomic nuclei. The effective electric field is the parameter that quantifies the sensitivity of such experiments to new physics. We describe the theoretical approach to calculating the effective electric field for noncentrosymmetric sites in ionic insulating solids. We consider the specific example of the crystal, which is a particularly promising material. The optimistic estimate of the effective electric field for the isotope in this crystal is . The calculation uncertainty is estimated to be two orders of magnitude, dominated by the evaluation of the europium nuclear Schiff moment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Universal time scalings of sensitivity in Markovian quantum metrology

Assuming Markovian time evolution of a quantum sensing system, we study the general characterization of the optimal sensitivity scalings with time, under most general quantum control protocols. We allow the estimated parameter to influence both the Hamiltonian as well as the dissipative part of the quantum master equation and focus on the asymptotic-time along with the short-time sensitivity scalings. We find that via simple algebraic conditions (in terms of the Hamiltonian, the jump operators as well as their parameter derivatives), one can characterize the four classes of metrological models that represent: quadratic-linear, quadratic-quadratic, linear-linear, and linear-quadratic time scalings. We also investigate the relevant time scales on which the transition between the two regimes appears. Additionally, we provide universal numerical methods to obtain quantitative bounds on sensitivity that are the tightest that exist in the literature. Simplicity and universality of our results make it suitable for diverse applications in quantum metrology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Projected sensitivity of the LUX-ZEPLIN experiment to the $0\nu\beta\beta$ decay of $^{136}Xe$

The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double β decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to Xe136 neutrinoless double β decay, taking advantage of the significant (>600 kg) Xe136 mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of Xe136 is projected to be 1.06×1026 years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with Xe136 at 1.06×1027 years.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian analysis of a future β decay experiment's sensitivity to neutrino mass scale and ordering

Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. In this work, we present procedures for calibrating predictions of an experiment's sensitivity to both continuous and discrete parameters. Using these procedures and a new Bayesian model of the β-decay spectrum, we assess a high-precision β-decay experiment's sensitivity to the neutrino mass scale and ordering for one assumed design scenario. We find that such an experiment could measure the electron-weighted neutrino mass within ~40 meV after 1 year (90% credibility). Neutrino masses > 500 meV could be measured within ≈5 meV. Using only β decay and external reactor neutrino data, we find that next-generation β-decay experiments could potentially constrain the mass ordering using a two-neutrino spectral model analysis. By calibrating mass ordering results, we identify reporting criteria that can be tuned to suppress false ordering claims. In some cases, a two-neutrino analysis can reveal that the mass ordering is inverted, an unobtainable result for the traditional one-neutrino analysis approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of neutron observables to the model input in simulations of 252 Cf ( sf )

Within the framework of $FREYA$ event-by-event fission simulations, we study the sensitivity of various neutron observables to the input yield function $Y$ ($A,Z,$TKE) on which the fission event sampling is based. We first perform a statistical analysis of the available fission data in order to determine the distribution of possible yield functions $Y$ ($A,Z$,TKE) and we then construct a sample of 15,000 such yield functions. For each of these, $FREYA$ is used to generate one million fission events, leading to a corresponding ensemble of fission observables, including the neutron multiplicity distribution and its factorial moments, the neutron energy spectrum, and the neutron-neutron angular correlation. This procedure allows us to study the sensitivity of those neutron observables to the uncertainty in the experimental data. Particular attention is given to the pronounced anticorrelation between the mean neutron multiplicity $\bar{v}$ and the mean total fragment kinetic energy TKE. Because the former observable is very well determined experimentally, it is possible to exploit that inherent anticorrelation to derive a significantly stricter tolerance on TKE. In addition, we study the sensitivity to the various $FREYA$ parameters and we introduce a method for determining a A-dependent x parameter, $x$($A$), based on the measured A-dependent neutron multiplicity, ($A$).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors

The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling 19 F and 12 C nuclei in low-pressure CF 4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30–60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Furthermore assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10–20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of Proposed Search for Axion-induced Magnetic Field using Optically Pumped Magnetometers

We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014)]. The modification of Maxwell’s equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. Here, we discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10 -7 GeV -1 for an axion mass near 3 × 10 -10 eV, which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10 -1 and 10 -7 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resurrecting Hitomi for Decaying Dark Matter and Forecasting Leading Sensitivity for XRISM

The Hitomi x-ray satellite mission carried unique high-resolution spectrometers that were set to revolutionize the search for sterile neutrino dark matter (DM) by looking for narrow x-ray lines arising from DM decays. Unfortunately, the satellite was lost shortly after launch, and to date the only analysis using Hitomi for DM decay used data taken towards the Perseus cluster. Here, in this work we present a significantly more sensitive search from an analysis of archival Hitomi data towards blank sky locations, searching for DM decaying in our own Milky Way. The recently launched XRISM satellite has nearly identical soft-x-ray spectral capabilities to Hitomi; we project the full-mission sensitivity of XRISM for analyses of their future blank-sky data, and we find that XRISM will have the leading sensitivity to decaying DM for masses between roughly 1 to 18 keV, with important implications for sterile neutrino and heavy axionlike particle DM scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Dynamic Temperature-Sensitive Electrical Parameters for Medium-Voltage Low-Current Silicon Carbide and Silicon Devices

This paper presents five dynamic temperature-sensitive electrical parameters (TSEPs) for the medium-voltage silicon carbide (SiC) and silicon (Si) devices. The theoretical temperature dependence of these parameters is analyzed. A test platform that enables to implement the temperature relevant dynamic characterization is developed. The tested TSEPs are summarized in terms of their relationship with junction temperature, drain/collector current, DC voltage, and external gate resistance. The comparison between the 3 kV 12 A Si IGBT and 3.3 kV 5 A SiC MOSFET with the identical TO-263 package is conducted. The results verify that the turn-off drain-source voltage switching rate achieves better thermal sensitivity for medium-voltage low-current SiC MOSFETs compared with Si IGBTs. Both the turn-on and turn-off delay time exhibit better thermal linearity for the two devices. The turn-off delay time further achieves five times better thermal sensitivity than the turn-on delay time for investigated medium-voltage SiC MOSFETs.

Ni, Ze↗

The Sensitivity Analysis of Coil Misalignment for a 200-kW Dynamic Wireless Power Transfer System with an LCC-S and LCC-P Compensation

The dynamic wireless power transfer systems may reduce the battery size of electric vehicles while maintaining the travel range. Similar to the stationary wireless power transfer systems, the compensation networks are desired in dynamic wireless charging systems at the primary and secondary sides to reduce the reactive power requirement from the source and improve the efficiency. Consequently, it is essential to understand the behavior of the compensation networks, especially the sensitivity to misalignments. This paper presents a sensitivity analysis of LCC-S and LCC-P compensation networks for a 200-kW power transfer with variations in the coupling coefficient due to the electric vehicle travel and misalignments between the pads. The sensitivity study combines the electromagnetic finite element analysis and circuit analysis to determine the impact of misalignments on the wireless power transfer system characteristics. The theoretical analysis is verified by conducting circuit simulations at discrete points to verify the accuracy of the mathematical model.

Kavimandan, Utkarsh↗

Efficiency and Output Power Sensitivity to Control Parameter Variations in an LCC-Series Wireless Power Transfer System

In wireless power transfer (WPT) systems, output power (Pout) can be controlled through input parameters such as, input voltage (Vin) , duty cycle (d) , and switching frequency (fsw) . The impact of these control parameters on the overall system efficiency has not been explored in previous studies. This paper focuses on the efficiency (η) and Pout sensitivity to these control parameter variations in an LCC-Series tuned WPT system. There are multiple combinations of Vin, d , and fsw that can achieve a specified target Pout . However, it is important to determine the optimal combination of these control variables that will yield the maximum η for a target Pout . A MATLAB/Simulink model is built to calculate and measure η and Pout . In order to achieve this result, several simulations are run where Vin,d , and fsw are swept across a wide range to cover all possible combinations. MATLAB's Sensitivity Analysis toolbox is used to evaluate how the parameters influence the model's output. Finally, an experimental prototype is implemented. The optimal values acquired using the sensitivity analysis is then plugged into the hardware prototype and compared with the simulation. The results obtained confirm the validity of the proposed method.

Harave, Sudarshan↗

Analysis of TPA Pulsed-Laser-Induced Single-Event Latchup Sensitive-Area

Two-photon absorption (TPA) testing is employed to analyze the laser-induced latchup sensitive-volume (SV) of a specially designed test structure. This method takes into account the existence of an onset region in which the probability of triggering latchup transitions from zero to one as the laser pulse energy increases. This variability is attributed to pulse-to-pulse variability, uncertainty in measurement of the pulse energy, and variation in local carrier density and temperature. For each spatial position, the latchup probability associated with a given energy is calculated from multiple pulses. The latchup probability data are well-described by a Weibull distribution. The results show that the area between p-n-p-n cell structures is more sensitive than the p+ and n+ source areas, and locations far from the well contacts are more sensitive than those near the contact region. The transition from low probability of latchup to high probability is more abrupt near the source contacts than it is for the surrounding areas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Fast Scalable Quasi-Static Time Series Analysis Method for PV Impact Studies Using Linear Sensitivity Model

Understanding the impact of distributed photovoltaic (PV) resources on various elements of the distribution feeder is imperative for their cost effective integration. A year-long quasi-static time series (QSTS) simulation at 1-second granularity is often necessary to fully study these impacts. However, the significant computational burden associated with running QSTS simulations is a major challenge to their adoption. In this paper, we propose a fast scalable QSTS simulation algorithm that is based on a linear sensitivity model for estimating voltage-related PV impact metrics of a three-phase unbalanced, nonradial distribution system with various discrete step control elements including tap changing transformers and capacitor banks. Here, the algorithm relies on computing voltage sensitivities while taking into account all the effects of discrete controllable elements in the circuit. Consequently, the proposed sensitivity model can accurately estimate the state of controllers at each time step and the number of control actions throughout the year. For the test case of a real distribution feeder with 2969 buses (5469 nodes), 6 load/PV time series power profiles, and 9 voltage regulating elements including controller delays, the proposed algorithm demonstrates a dramatic time reduction, more than 180 times faster than traditional QSTS techniques.

14 SOLAR ENERGY↗