Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Characterizing Radiation-Induced Chromium Redox Chemistry

The redox behavior of Cr(III) and Cr(VI) in nuclear environments were studied by analyzing aqueous irradiated chromium ions using UV-Visible spectroscopy. The formation of different chromium oxidation states can occur through gamma radiolysis of chromium solutions. Characterization of radiation-induced chromium is not well understood, and yet important as chromium can make its way into the primary coolant of reactors because of the corrosion of stainless steel reactor components. Furthermore, Cr(VI) is toxic and not suitable for environmental release, therefore Cr speciation is important. Fricke dosimetry was performed to collect doses rates, specific extinction coefficients were obtained from various analytical methods for the two oxidation states of chromium. Chromium samples--conditioned at various pH's and concentration to understand the effects--were then irradiated using a Coblat-60 gamma irradiator. Three optical spectroscopy analytical methods were used , including direct oxidation state measurements and complexation by either EDTA or DPC. Complexation by EDTA was found to not be a reliable method. Radiolytic oxidation of Cr(III) to Cr(VI), and reduction of Cr(VI) to Cr(III) were clearly seen, except for Cr(III) samples were a pH less than or equal to 2, where no change occurred.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Subsampling and DNA pooling can increase gains through genomic selection in switchgrass

Genomic selection (GS) can accelerate breeding cycles in perennial crops such as the bioenergy grass switchgrass (Panicum virgatum L.). The sequencing costs of GS can be reduced by pooling DNA samples in the training population (TP), only sequencing TP phenotypic outliers, or pooling candidate population (CP) samples. These strategies were simulated for two traits (spring vigor and anthesis date) in three breeding populations. Sequencing only the outlier 50% of the TP phenotype distribution resulted in a penalty of <5% of the predictive ability, measured using cross-validation. Predictive ability also decreased when sequencing progressively fewer TP DNA pools, but TPs constructed from only two phenotypically contrasting DNA samples retained a mean of >80% predictive ability relative to individual TP sequencing. Novel group testing methods allowed greater than one CP individual to be screened per sequenced DNA sample but resulted in a predictive ability penalty. To determine the impact of reduced sequencing, genetic gain was calculated for seven GS scenarios with variable sequencing budgets. Reduced TP sequencing and most CP pooling methods were superior to individual sequence-based GS when sequencing resources were restricted (2,000 DNA samples per 5-yr cycle). Only one scenario was superior to individual sequencing when sequencing budgets were large (8,000 DNA samples per 5-yr cycle). This study highlights multiple routes for reduced sequencing costs in GS.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting differential protein abundance by combining peptide level P -values

The majority of methods for detecting differentially abundant proteins between samples in label-free LC-MS bottom-up proteomics experiments rely on statistically testing inferred protein abundances derived from peptide ionization intensities or averaging peptide level statistics. Here in this paper, we statistically test peptide ionization intensities directly and combine the resulting dependent P-values using the Empirical Brown's Method (EBM), avoiding error introduced through the estimation of protein abundances or summarizing test statistics. We show that on a spike-in proteomics dataset, a peptide level approach using EBM outperforms differential abundance detection using a protein level approach and several analysis workflows, including MSstats. Additionally, we demonstrate the effectiveness of this approach by detecting enriched proteins from an activity-based protein profiling dataset.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the NO reduction by CO reaction over oxidized and reduced NiO x /CeO 2 catalysts

CeO 2 -supported NiO x catalysts have been widely studied in various catalytic reactions including NO reduction by CO. This work is mainly focused on investigation of the impact of catalyst synthesis conditions (e.g., oxidation and reduction) on the physicochemical properties of NiO x /CeO 2 catalysts and the catalytic response for the NO reduction by CO reaction. The oxide NiO x /CeO 2 sample was prepared by an incipient wetness impregnation (IWI) method and reduced under hydrogen reduction treatment at high temperatures (500 and 700 °C). The physicochemical properties of the synthesized samples were characterized by BET analysis, Raman spectroscopy, XRD, XPS, EELS and high-resolution transmission electron microscopy (HR-TEM). The results showed that higher reduction temperature led to the decrease in specific surface area (SSA), fewer oxygen vacancy/defect site, larger crystallite size of the CeO 2 support, and formation of metallic Ni on the surface. The oxidized NiO x /CeO 2 catalyst showed the highest catalytic activity, indicating that the presence of oxygen vacancy/defect sites, Ni 2+ oxidation state, and smaller crystallite size are believed to enhance the catalytic activity. In situ DRIFTS confirmed the generation of several intermediate species, such as nitrate, carbonate, and N 2 O. Finally, on the basis of in situ DRIFTS and activity results, the possible reaction mechanism of NO reduction by CO over NiO x /CeO 2 was proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimating the Timing of Early Simian-Human Immunodeficiency Virus Infections: a Comparison between Poisson Fitter and BEAST

Many HIV prevention strategies are currently under consideration where it is highly informative to know the study participants’ times of infection. These can be estimated using viral sequence data sampled early in infection. However, there are several scenarios that, if not addressed, can skew timing estimates. These include multiple transmitted/founder (TF) viruses, APOBEC (apolipoprotein B mRNA editing enzyme, catalytic polypeptide-like)-mediated mutational enrichment, and recombination. Here, we suggest a pipeline to identify these problems and resolve the biases that they introduce. We then compare two modeling strategies to obtain timing estimates from sequence data. The first, Poisson Fitter (PF), is based on a Poisson model of random accumulation of mutations relative to the TF virus (or viruses) that established the infection. The second uses a coalescence-based phylogenetic strategy as implemented in BEAST. The comparison is based on timing predictions using plasma viral RNA (cDNA) sequence data from 28 simian-human immunodeficiency virus (SHIV)-infected animals for which the exact day of infection is known. In this particular setting, based on nucleotide sequences from samples obtained in early infection, the Poisson method yielded more accurate, more precise, and unbiased estimates for the time of infection than did the explored implementations of BEAST. The inference of the time of infection is a critical parameter in testing the efficacy of clinical interventions in protecting against HIV-1 infection. For example, in clinical trials evaluating the efficacy of passively delivered antibodies (Abs) for preventing infections, accurate time of infection data are essential for discerning levels of the Abs required to confer protection, given the natural Ab decay rate in the human body. In such trials, genetic sequences from early in the infection are regularly sampled from study participants, generally prior to immune selection, when the viral population is still expanding and genetic diversity is low. In this particular setting of early viral growth, the Poisson method is superior to the alternative approach based on coalescent methods. This approach can also be applied in human vaccine trials, where accurate estimates of infection times help ascertain if vaccine-elicited immune protection wanes over time.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bile salt hydrolase probe and method of making and using the same

Probe embodiments for targeting, identifying, and isolating enzymes exhibiting BSH activity as well as devices and kits that use the probes are described herein. Methods of making and using the probes, devices, and kits are also described. In some embodiments, probes, devices, and kits for targeting, identifying, and isolating enzymes in a biological sample are disclosed. In some embodiments, compositions and methods of treatment using the probes, devices, and kits disclosed herein are described.

Wright, Aaron T.↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Proposal and application of ROM-Lasso method for sensitivity coefficient evaluation

We propose a novel method for evaluating sensitivity coefficients of neutronics parameters to cross sections, so-called the reduced-order modeling technique ROM-Lasso. In this method, cross sections of interest are randomly sampled, and corresponding perturbed core analyses are performed. Then, the sensitivity coefficient vector of the higher-level model is expanded via the active subspace bases obtained with the lower-level model whose dimensional complexity is smaller than that of the higher-level model, and the expansion coefficients are estimated by the Lasso regression. A unique feature of the ROM-Lasso method allows the use of different bases optimized for each neutronics parameter. We conducted a verification calculation for an accelerator-driven system and demonstrated that the ROM-Lasso method can reproduce the sensitivity coefficients with a much smaller number of forward calculations than the direct method. The proposed method can be used to practically evaluate sensitivity coefficients. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-throughput micro-scale bandgap mapping for perovskite-inspired materials with complex composition space

Abstract To realize the full promise of high-throughput experimental workflows, the rate of sample synthesis must be matched by that of characterization. Of growing interest are contactless optical techniques that can rapidly measure material homogeneity and properties. Here, we present a hyperspectral imaging method to measure local optical bandgap distributions within samples, utilizing spatially-resolved reflectance spectra coupled with automated data analysis. We collect approximately one million optical bandgap data across the compositional space of Cs 3 (Bi x Sb 1-x ) 2 (Br y I 1-y ) 9 perovskite-inspired materials. Our results show non-monotonic bandgap variations (i.e., bandgap bowing) along six composition gradient sequences, in addition to identifying samples with multiple bandgaps in statistics. High-throughput transient absorption spectroscopy reveals that within these compositions, the depletion of the ground state carriers to excited states occurred at discrete energy levels with independent carrier dynamics, consistent with the bandgap observation and indicative of phase separation. This work demonstrates the potential for rapid optical measurements to assess material quality and homogeneity in a high-throughput experimental setting, supporting screening and recipe optimization of optoelectronic material candidates with desired carrier dynamics and optical properties.

Science & Technology - Other Topics↗

The mass profiles of dwarf galaxies from Dark Energy Survey lensing

We present a novel approach to extracting dwarf galaxies from photometric data to measure their average halo mass profile with weak lensing. We characterize their stellar mass and redshift distributions with a spectroscopic calibration sample. By combining the ${\sim} 5000\,\mathrm{deg}^2$ multiband photometry from the Dark Energy Survey and redshifts from the Satellites Around Galactic Analogs Survey with an unsupervised machine learning method, we select a low-mass galaxy sample spanning redshifts $z\lt 0.3$ and divide it into three mass bins. From low to high median mass, the bins contain [146 420, 330 146, 275 028] galaxies and have median stellar masses of $\log _{10}(M_*/\text{M}_\odot)=\left[8.52\substack{+0.57 -0.76},\, 9.02\substack{+0.50 -0.64},\, 9.49\substack{+0.50 -0.58}\right]$ . We measure the stacked excess surface mass density profiles, $\Delta \Sigma (R)$, of these galaxies using galaxy–galaxy lensing with a signal-to-noise ratio of [14, 23, 28]. Through a simulation-based forward-modelling approach, we fit the measurements to constrain the stellar-to-halo mass relation and find the median halo mass of these samples to be $\log _{10}(M_{\rm halo}/\text{M}_\odot)$ = [$10.67\substack{+0.2 -0.4}$, $11.01\substack{+0.14 -0.27}$, $11.40\substack{+0.08 -0.15}$]. The cold dark matter profiles are consistent with NFW (Navarro, Frenk, and White) profiles over scales ${\lesssim} 0.15 \, {h}^{-1}$ Mpc. We find that ${\sim} 20$ per cent of the dwarf galaxy sample are satellites. This is the first measurement of the halo profiles and masses of such a comprehensive, low-mass galaxy sample. The techniques presented here pave the way for extracting and analysing even lower mass dwarf galaxies and for more finely splitting galaxies by their properties with future photometric and spectroscopic survey data.

dark matter↗

Predicting failure parameters of semiconductor devices subjected to stress conditions

A method for predicting failure parameters of semiconductor devices can include receiving a set of data that includes (i) characteristics of a sample semiconductor device, and (ii) parameters characterizing a stress condition. The method further includes extracting a plurality of feature values from the set of data and inputting the plurality of feature values into a trained model executing on the one or more processors, wherein the trained model is configured according to an artificial intelligence (AI) algorithm based on a previous plurality of feature values, and wherein the trained model is operable to output a failure prediction based on the plurality of feature values. Further, the method includes generating, via the trained model, a predicted failure parameter of the sample semiconductor device due to the stress condition.

Ahmed, Moinuddin↗

Analysis and Testing of Parsons NGS Solvent Formulation

Three drums containing solvent used during the Next Generation Solvent Test (NGST) conducted by Parsons in 2014-2015 were received at SRNL. After homogenization, samples from each drum were removed, and a composite sample prepared. This composite was analyzed to determine current SRNL characterization method efficacy, and to determine if the 1,3-dicyclohexyl-2- (isotridecyl) guanidine (DCiTG) suppressor could be selectively removed. The results of this work indicate that the titration analytical method currently employed at SRNL is effective at quantitating the DCiTG. The nuclear magnetic resonance (NMR) method at SRNL can detect the DCiTG, as well its amine and urea decomposition products. However, further development work will be required to allow the 1 H NMR method to quantitate these species. A series of three washing tests were performed on composite samples of the solvent. The results show that up to 67% of the DCiTG was removed from the solvent by simple washing, at multiple ratios of solvent: aqueous phase. This may indicate that a simple pathway exists to wash out the DCiTG and reclaim the solvent (~150 gallons) for future use at the Salt Waste Processing Facility (SWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Molten Salt and Gas Monitoring Using Combined Spectroscopic Methods

The nonproliferation of nuclear material and the development of safeguards technologies to sample and analyze fuel salt is a challenge for molten salt reactor (MSR) developers. We seek online monitoring using combined spectroscopic methods of two distinct material phases from MSR’s. Molten salt transformed to aerosol phase allows for Light Induced Breakdown spectroscopy (LIBS) without adverse splashing (ARPA-E). Vaporized used nuclear fuel through chlorine-based volatility (CBV) allows for uranium separation based on boiling point differences

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SetBERT: the deep learning platform for contextualized embeddings and explainable predictions from high-throughput sequencing

MOTIVATION: High-throughput sequencing (HTS) is a modern sequencing technology used to profile microbiomes by sequencing thousands of short genomic fragments from the microorganisms within a given sample. This technology presents a unique opportunity for artificial intelligence to comprehend the underlying functional relationships of microbial communities. However, due to the unstructured nature of HTS data, nearly all computational models are limited to processing DNA sequences individually. This limitation causes them to miss out on key interactions between microorganisms, significantly hindering our understanding of how these interactions influence the microbial communities as a whole. Furthermore, most computational methods rely on post-processing of samples which could inadvertently introduce unintentional protocol-specific bias. RESULTS: Addressing these concerns, we present SetBERT, a robust pre-training methodology for creating generalized deep learning models for processing HTS data to produce contextualized embeddings and be fine-tuned for downstream tasks with explainable predictions. By leveraging sequence interactions, we show that SetBERT significantly outperforms other models in taxonomic classification with genus-level classification accuracy of 95%. Furthermore, we demonstrate that SetBERT is able to accurately explain its predictions autonomously by confirming the biological-relevance of taxa identified by the model. AVAILABILITY AND IMPLEMENTATION: All source code is available at https://github.com/DLii-Research/setbert. SetBERT may be used through the q2-deepdna QIIME 2 plugin whose source code is available at https://github.com/DLii-Research/q2-deepdna.

Ludwig, David W↗