Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Rare earth element geochemistry of outcrop and core samples from the Marcellus Shale

In this paper, we studied the geochemistry of the rare earth elements (REE) in eleven outcrop samples and six, depth-interval samples of a core from the Marcellus Shale. The REE are classically applied analytes for investigating depositional environments and inferring geochemical processes, making them of interest as potential, naturally occurring indicators of fluid sources as well as indicators of geochemical processes in solid waste disposal. However, little is known of the REE occurrence in the Marcellus Shale or its produced waters, and this study represents one of the first, thorough characterizations of the REE in the Marcellus Shale. In these samples, the abundance of REE and the fractionation of REE profiles were correlated with different mineral components of the shale. Namely, samples with a larger clay component were inferred to have higher absolute concentrations of REE but have less distinctive patterns. Conversely, samples with larger carbonate fractions exhibited a greater degree of fractionation, albeit with lower total abundance. Further study is necessary to determine release mechanisms, as well as REE fate-and-transport, however these results have implications for future brine and solid waste management applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Microbial Detection Array Combined with Random Phi29-Amplification Used as a Diagnostic Tool for Virus Detection in Clinical Samples

A common technique used for sensitive and specific diagnostic virus detection in clinical samples is PCR that can identify one or several viruses in one assay. However, a diagnostic microarray containing probes for all human pathogens could replace hundreds of individual PCR-reactions and remove the need for a clear clinical hypothesis regarding a suspected pathogen. We have established such a diagnostic platform for random amplification and subsequent microarray identification of viral pathogens in clinical samples. We show that Phi29 polymerase-amplification of a diverse set of clinical samples generates enough viral material for successful identification by the Microbial Detection Array, demonstrating the potential of the microarray technique for broad-spectrum pathogen detection. We conclude that this method detects both DNA and RNA virus, present in the same sample, as well as differentiates between different virus subtypes. We propose this assay for diagnostic analysis of viruses in clinical samples.

59 BASIC BIOLOGICAL SCIENCES↗

Investigating the Impact of Storage Conditions on Microbial Community Composition in Soil Samples

Recent advances in DNA sequencing technologies have allowed scientists to probe increasingly complex biological systems, including the diversity of bacteria in the environment. However, despite a multitude of recent studies incorporating these methods, many questions regarding how environmental samples should be collected and stored still persist. Here, we assess the impact of different soil storage conditions on microbial community composition using Illumina-based 16S rRNA V4 amplicon sequencing. Both storage time and temperature affected bacterial community composition and structure. Frozen samples maintained the highest alpha diversity and differed least in beta diversity, suggesting the utility of cold storage for maintaining consistent communities. Samples stored for intermediate times (three and seven days) had both the highest alpha diversity and the largest differences in overall beta diversity, showing the degree of community change after sample collection. These divergences notwithstanding, differences in neither storage time nor storage temperature substantially altered overall communities relative to more than 500 previously examined soil samples. These results systematically support previous studies and stress the importance of methodological consistency for accurate characterization and comparison of soil microbiological assemblages.

59 BASIC BIOLOGICAL SCIENCES↗

Locations, metadata, and species cover from field sampling survey associated with NEON AOP survey, East River, CO 2018

Locations and descriptions of the sites where field sampling was conducted during the 2018 National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) imaging spectroscopy and lidar surveys in Gunnison County, Colorado. The sampling sites were located across East River, Washington Gulch, Slate River, and Coal Creek watersheds and contained a mixture of meadow, shrub, and tree sampling sites. This data package contains the location, metadata, species composition, and vector files for the sampling sites in this project. Species vouchers that have been preserved in the Rocky Mountain Biological Laboratory herbarium can be found on the Consortia of Southern Rocky Mountain Herbaria website: http://soroherbaria.org/portal/collections/index.php. Vector files provided here are for areas delineated based on the AOP reflectance data and mosaic developed by Brodrick et al. (doi: 10.15485/1618131), and use with other datasets should be closely evaluated. Subsequent data packages will contain additional biogeochemical, microbial, and geophysical data as they become available for these sampling sites. For full documentation, please see associated reference and additional references will be added here as they become available.

2018 NEON and 2025 CHESS Campaigns↗

Site-level Foliar C, N, delta13C data from samples collected during field survey associated with NEON AOP survey, East River, CO 2018

Carbon (C) and nitrogen (N) weight percent concentrations were obtained from the bulk foliar samples collected across East River, Washington Gulch, Slate River, and Coal Creek watersheds in Gunnison, Colorado during the summer of 2018. These samples were collected from sun-lit leaves of meadow, shrub, and tree vegetation types within 72 hours of the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) hyperspectral survey. These samples were dried and then run on an elemental analyzer coupled to a mass spectrometer for C and N concentrations and delta13C. The intention of these data were to provide ground truth data to develop foliar nutrient models across the imaging spectroscopy domain. Additional associated site metadata and vegetation fractional cover information can be found in the associated data releases (DOI: 10.15485/1618130). Here we provide site level C, N, and delta 13C data in the CN_Results_Foliar.csv. All of these samples were also registered with IGSN codes, and the details from that registration with metadata for the samples is included in foliar_sample_igsn_metadata.csv.

54 ENVIRONMENTAL SCIENCES↗

DATA QUALITY OBJECTIVES FOR SELECTING WASTE SAMPLES FOR THE BENCH STEAM REFORMER TEST

This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required. The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

VERIFICATION OF THE DEFENSE WASTE PROCESSING FACILITY'S (DWPF) PROCESS DIGESTION METHOD FOR THE SLUDGE BATCH 7A QUALIFICATION SAMPLE

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs confirmation of the applicability of the digestion method to be used by the DWPF lab for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) receipt samples and SRAT product process control samples. DWPF SRAT samples are typically dissolved using a room temperature HF-HNO{sub 3} acid dissolution (i.e., DWPF Cold Chem Method, see DWPF Procedure SW4-15.201) and then analyzed by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). This report contains the results and comparison of data generated from performing the Aqua Regia (AR), Sodium peroxide/Hydroxide Fusion (PF) and DWPF Cold Chem (CC) method digestions of Sludge Batch 7a (SB7a) SRAT Receipt and SB7a SRAT Product samples. The SB7a SRAT Receipt and SB7a SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constituates the SB7a Batch or qualification composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 6 (SB6), to form the Sb7a Blend composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 AND MCU-11-319

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 are reported. The results show that the solvent at MCU does not require an Isopar{reg_sign} L addition, but it will require addition of trioctylamine. Cesium mass transfer testing with the solvent matches expected extraction behavior but shows a slightly lower stripping efficiency than seen in the original process demonstration for Macrobatch 3. The entrained aqueous solution indicates the scrub wash is significantly out of specification. As a result, the facility replaced the scrub wash. Unlike the previous solvent sample results, these analyses indicate that the solvent does not require minor Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended. The {sup 137}Cs mass transfer results from the solvent sample testing show possible evidence of slightly reduced stripping efficiency. An evaluation (using a model) of expected system performance for MCU using the measured distribution values predicts an {approx}50% decline in DFs given the ESS test results. The customer should consider pulling a SHT sample for reanalysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Germanium-76 Sample Analysis: Revision 3

The MAJORANA DEMONSTRATOR is a large array of ultra-low background high-purity germanium detectors, enriched in 76Ge, designed to search for zero-neutrino double-beta decay (0{nu}{beta}{beta}). The DEMONSTRATOR will utilize 76Ge from Russia. The first one-gram sample was received from the supplier for analysis on April 24, 2011. The second one-gram sample was received from the supplier for analysis on July 12, 2011. The third sample, which came from the first large shipment of germanium from the vendor, was received from Oak Ridge National Laboratory (ORNL) on September 13, 2011. The Environmental Molecular Sciences facility, a DOE user facility at PNNL, was used to make the required isotopic and chemical purity measurements that are essential to the quality assurance for the MAJORANA DEMONSTRATOR. The results of these analyses are reported here. The isotopic composition of a sample of natural germanium was also measured twice. Differences in the result between these two measurements led to a re-measurement of the second 76Ge sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CHARACTERIZATION OF DWPF MELTER OFF-GAS QUENCHER SAMPLE

The Savannah River National Laboratory (SRNL) recently received a deposit sample from the Melter Primary Off Gas System (POG) of the Defense Waste Processing Facility (DWPF). This sample was composed of material that had been collected while the quencher was in operation January 27, 2011 through March 31, 2011. DWPF requested, through a technical assistance request, characterization of the melter off-gas deposits by x-ray diffraction (XRD), scanning electron microscopy (SEM), and chemical analysis. The purpose of the Melter Off-Gas System is to reduce the amount of radioactive particles and mercury in the gases vented to the atmosphere. Gases emitted from the melter pass through the primary film cooler, quencher, Off-Gas Condensate Tank (OGCT), Steam Atomized Scrubbers (SAS), a condenser, a high efficiency mist eliminator, and a high efficiency particulate air filter, before being vented to the Process Vessel Vent System. The film coolers cool the gases leaving the melter vapor space from {approx}750 C to {approx}375 C, by introducing air and steam to the flow. In the next step, the quencher cools the gas to about 60 C by bringing the condensate from the OGCT in contact with the effluent (Figure 1). Most of the steam in the effluent is then condensed and the melter vapor space pressure is reduced. The purpose of the OGCT is to collect and store the condensate formed during the melter operation. Condensate from the OGCT is circulated to the SAS and atomized with steam. This atomized condensate is mixed with the off-gas to wet and join the particulate which is then removed in the cyclone. The next stage incorporates a chilled water condenser which separates the vapors and elemental mercury from the off-gas steam. Primary off-gas deposit samples from the DWPF melter have previously been analyzed. In 2003, samples from just past the film cooler, from the inlet of the quencher and inside the quencher were analyzed at SRNL. It was determined that the samples were a mixture of sludge and glass frit. The major component was Si along with Fe, Al, and other elements in the radioactive waste being processed. The deposits analyzed also contained U-235 fission products and actinide elements. Prior to that, deposits in the off-gas system in the DWPF nonradioactive half scale melter and the one-tenth scale integrated DWPF melter system were analyzed and determined to be mixtures of alkali rich chlorides, sulfates, borates, and fluorides entrained with iron oxides, spinels and frit particles formed by vapor-phase transport and condensation. Additional work was performed in 2007 in which researchers similarly found the deposits to be a combination of sludge and frit particles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REPORT ON THE ANALYSIS OF WAC SAMPLES FROM EVAPORATOR OVERHEADS FOR 2011

This report tabulates the chemical analysis of the 3H, 2H and 2F evaporator overhead samples including the inorganic, organic, and radionuclide species according the ETP WAC (rev.4). In addition, the physical properties including pH, total suspended solids, and average particle size are listed for each sample. The report identifies all sample receipt dates, preparation methods, and analyses completed to accumulate these values. All values were found to be within the ETP WAC specifications for WWCT except for the {sup 137}Cs concentration for the 2F sample which was slightly above the limit (~5%). However, tank farm personnel sample each tank overhead for beta/gamma prior to transfer using a pulse height analyzer and these field readings were all well within limits. Additional actions will be taken to help understand the reason in the discrepancy of the field measurement versus laboratory analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 16 Annulus Samples

The closure of Tank 16H will require removal of material from the annulus of the tank. Samples from Tank 16H annulus were characterized and tested to provide information to evaluate various alternatives for removing the annulus waste. The analysis found all four annulus samples to be composed mainly of Si, Na, and Al and lesser amounts of other elements. The XRD data indicate quartz (SiO 2 ) and sodium aluminum nitrate silicate hydrate (Na 8 (Al 6 Si 6 O 24 )(NO 3 ) 2 .4H 2 O) as the predominant crystalline mineral phases in the samples. The XRD data also indicate the presence of crystalline sodium nitrate, sodium nitrite, gibbsite, hydrated sodium bicarbonate, and muscovite. Based on the weight of solids remaining at the end of the test, the water leaching test results indicate approximately 20-35% of the solids dissolved after three contacts with an approximately 3:1 volume of water at 45 C. The chemical analysis of the leachates and the XRD results of the remaining solids indicate sodium salts of nitrate, nitrite, sulfate, and possibly carbonate/bicarbonate make up the majority of the dissolved material. The majority of these salts were dissolved in the first water contact and simply diluted with each subsequent water contact. The water leaching removed large amounts of the uranium in two of the samples and {approx}1/3 of the {sup 99}Tc from all four samples. Most of the other radionuclides analyzed showed low solubility in the water leaching test. The preliminary data on the oxalic acid leaching test indicate the three acid contacts at 45 C dissolved from {approx}34-47% of the solids. The somewhat higher dissolution found in the oxalic acid leaching test versus the water leaching test might be offset by the tendency of the oxalic acid solutions to take on a gel-like consistency. The filtered solids left behind after three oxalic acid contacts were sticky and formed large clumps after drying. These two observations could indicate potential processing difficulties with solutions and solids from oxalic acid leaching. The gel formation might be avoided by using larger volumes of the acid. Further testing would be recommended before using oxalic acid to dissolve the Tank 16H annulus waste to ensure no processing difficulties are encountered in the full scale process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis Of DWPF Sludge Batch 7a (Macrobatch 8) Pour Stream Samples

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 7a (SB7a), also referred to as Macrobatch 8 (MB8), in June 2011. SB7a is a blend of the heel of Tank 40 from Sludge Batch 6 (SB6) and the SB7a material that was transferred to Tank 40 from Tank 51. SB7a was processed using Frit 418. During processing of each sludge batch, the DWPF is required to take at least one glass sample to meet the objectives of the Glass Product Control Program (GPCP), which is governed by the DWPF Waste Compliance Plan, and to complete the necessary Production Records so that the final glass product may be disposed of at a Federal Repository. Three pour stream glass samples and two Melter Feed Tank (MFT) slurry samples were collected while processing SB7a. These additional samples were taken during SB7a to understand the impact of antifoam and the melter bubblers on glass redox chemistry. The samples were transferred to the Savannah River National Laboratory (SRNL) where they were analyzed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Report on Post-Irradiation Dimensional Change of AGC-1 Samples

This report summarizes the initial dimensional changes for loaded and unloaded AGC-1 samples. The dimensional change for all samples is presented as a function of dose. The data is further presented by graphite type and applied load levels to illustrate the differences between graphite forming processes and stress levels within the graphite components. While the three different loads placed on the samples have been verified [ ref: Larry Hull’s report] verification of the AGC-1 sample temperatures and dose levels are expected in the summer of 2012. Only estimated dose and temperature values for the samples are presented in this report to allow a partial analysis of the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wipe Sampling Collection Efficiencies and Holding Time Studies

Despite the fact that wipe sampling is commonly performed and the data produced by this technique is used to make numerous decisions, there is not an overwhelming consensus on the best method for collecting a wipe sample. It is generally agreed that, in order to produce reproducible quantitative results, consistent wetting solvents, wipe materials, sampling techniques, and sampling areas must be used. In addition, wetting solvents should be selected with consideration of the analyte of interest and wet wipes are better than dry wipes for the collection of organic chemicals. Thus, the goal of the Lawrence Livermore National Laboratory (LLNL) study was to understand factors affecting wipe sampling for specific chemical warfare agents (CWAs), including sarin (GB), soman (GD), cyclosarin (GF), distilled sulfur mustard (HD), and O-ethyl-S-(2-diisopropylaminoethyl) methylphosphonothioate (VX), and the pesticides diazinon and malathion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics of STP Pre-2004 Archived KE Basin Sludge Samples Before and After Re-Jarring in the RPL - April 2012

This report describes results of work performed in the Shielded Analytical Laboratory (SAL) at the Pacific Northwest National Laboratory’s (PNNL) Radiochemical Processing Laboratory (RPL) with archive K East (KE) Basin sludge samples obtained before the year 2004, with some of them composited and initially characterized five years ago (Delegard et al. 2011). The previously performed testing included the physical properties determinations for selected samples (settled and particle densities, water and solids concentrations), the pH, as well as identification of crystalline phases by X-ray diffractometry (XRD) for selected samples. Another objective of the previous characterization and testing campaign was to transfer some sludge composites and individual samples into new storage containers to overcome the embrittlement effect which develops in original glass containers as a result of extended exposure to high radiation fields and which increases probability of sample loss.

K Basin↗

BioWatch Sample Management System (SMS) Field Operator Guide

The BioWatch Sample Management System is software developed by Los Alamos National Laboratory to support the Department of Homeland Security BioWatch program. Field Operators use the software to keep track of samples and to provide information on the sample management process to other users and software programs within BioWatch. The information tracked about a sample includes the date and time the filter media is assembled in a filter holder, deployed to the field, placed in and removed from a collector, and received from the field, and identifies who performs each task. Field Operators can also use the software to prepare and print forms to document the chain-of-custody transfer of the samples. The BioWatch SMS Field Operator Guide provides easy-to-understand procedures for each task a Field Operator performs. This guide gives basic information about using the computer and other equipment, instructions about checking and editing data, and provides reference information, including appendices of error messages and solutions, words used interchangeably, and safety warnings plus a glossary and an index.

99 GENERAL AND MISCELLANEOUS↗

Analytical Results For MOX Colemanite Concrete Samples Received On September 4, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received three samples of colemanite concrete for analysis on September 4, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗