Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Impact of eV-mass sterile neutrinos on neutrino-driven supernova outflows

Motivated by recent hints for sterile neutrinos from the reactor anomaly, we study active-sterile conversions in a three-flavor scenario (2 active + 1 sterile families) for three different representative times during the neutrino-cooling evolution of the proto-neutron star born in an electron-capture supernova. In our ''early model'' (0.5 s post bounce), the ν{sub e}-ν{sub s} MSW effect driven by Δm{sup 2} = 2.35eV{sup 2} is dominated by ordinary matter and leads to a complete ν{sub e}-ν{sub s} swap with little or no trace of collective flavor oscillations. In our ''intermediate'' (2.9 s p.b.) and ''late models'' (6.5 s p.b.), neutrinos themselves significantly modify the ν{sub e}-ν{sub s} matter effect, and, in particular in the late model, νν refraction strongly reduces the matter effect, largely suppressing the overall ν{sub e}-ν{sub s} MSW conversion. This phenomenon has not been reported in previous studies of active-sterile supernova neutrino oscillations. We always include the feedback effect on the electron fraction Y{sub e} due to neutrino oscillations. In all examples, Y{sub e} is reduced and therefore the presence of sterile neutrinos can affect the conditions for heavy-element formation in the supernova ejecta, even if probably not enabling the r-process in the investigated outflows of an electron-capture supernova. The impact of neutrino-neutrino refraction is strong but complicated, leaving open the possibility that with a more complete treatment, or for other supernova models, active-sterile neutrino oscillations could generate conditions suitable for the r-process.

79 ASTRONOMY AND ASTROPHYSICS↗

Atlas of solar hidden photon emission

Hidden photons, gauge bosons of a U(1) symmetry of a hidden sector, can constitute the dark matter of the universe and a smoking gun for large volume compactifications of string theory. In the sub-eV mass range, a possible discovery experiment consists on searching the copious flux of these particles emitted from the Sun in a helioscope setup à la Sikivie. In this paper, we compute in great detail the flux of HPs from the Sun, a necessary ingredient for interpreting such experiments. We provide a detailed exposition of transverse photon-HP oscillations in inhomogenous media, with special focus on resonance oscillations, which play a leading role in many cases. The region of the Sun emitting HPs resonantly is a thin spherical shell for which we justify an averaged-emission formula and which implies a distinctive morphology of the angular distribution of HPs on Earth in many cases. Low mass HPs with energies in the visible and IR have resonances very close to the photosphere where the solar plasma is not fully ionised and requires building a detailed model of solar refraction and absorption. We present results for a broad range of HP masses (from 0–1 keV) and energies (from the IR to the X-ray range), the most complete atlas of solar HP emission to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extragalactic photon-ALP conversion at CTA energies

Magnetic fields in extragalactic space between galaxy clusters may induce conversions between photons and axion-like particles (ALPs), thereby shielding the photons from absorption on the extragalactic background light. For TeV gamma rays, the oscillation length (l osc ) of the photon-ALP system becomes inevitably of the same order as the coherence length of the magnetic field l and the length over which the field changes significantly (transition length l t ) due to refraction on background photons. We derive exact statistical evolution equations for the mean and variance of the photon and ALP transfer functions in the non-adiabatic regime (l osc ~ l >> l t ). We also make analytical predictions for the transfer functions in the quasi-adiabatic regime (l osc < t ). Our results are important in light of the upcoming Cherenkov Telescope Array (CTA), and may also be applied to models with non-zero ALP masses.

79 ASTRONOMY AND ASTROPHYSICS↗

General scaling limitations of ground-plane and isolated-object cloaks

We prove that, for arbitrary three-dimensional transformation-based invisibility cloaking of an object above a ground plane or of isolated objects, there are practical constraints that increase with the object size. In particular, we show that the cloak thickness must scale proportionally to the thickness of the object being cloaked, assuming bounded refractive indices, and that absorption discrepancies and other imperfections must scale inversely with the object thickness. For isolated objects, we also show that bounded refractive indices imply a lower bound on the effective cross section.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced and switchable spin Hall effect of light near the Brewster angle on reflection

We theorize an enhanced and switchable spin Hall effect (SHE) of light near the Brewster angle on reflection and demonstrate it experimentally. The obtained spin-dependent splitting reaches 3200 nm near the Brewster angle, which is 50 times larger than the previously reported values in refraction. We find that the amplifying factor in weak measurement is not a constant, which is significantly different from that in refraction. As an analogy of SHE in an electronic system, a switchable spin accumulation in SHE of light is detected. We were able to switch the direction of the spin accumulations by slightly adjusting the incident angle.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four-dimensional visualization of single and multiple laser filaments using in-line holographic microscopy

It is shown, both through simulations and experiments, that the in-line holographic microscopy technique can be used to retrieve very small refractive-index perturbations caused during the filamentation of ultrashort laser pulses. This technique provides the possibility of having spatially and temporally (four dimensions) resolved measurements of refractive-index changes, down to 10{sup -4}, from objects with diameters as small as 10 {mu}m. Moreover, we demonstrate the power of the technique in discriminating multiple filaments in a precise quantitative way.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunneling away the relic neutrino asymmetry

The Earth acts as a matter potential for relic neutrinos which modifies their index of refraction from vacuum by δ ∼ 10 − 8 . It has been argued that the refractive effects from this potential should lead to a large O ( δ ) neutrino-antineutrino asymmetry at the surface of the Earth. This result was computed by treating the Earth as flat. In this work, we revisit this calculation in the context of a perfectly spherical Earth. We demonstrate, both numerically and through analytic arguments, that the flat-Earth result is only recovered under the condition δ 3 / 2 k R ≫ 1 , where k is the typical momentum of the relic neutrinos and R is the radius of the Earth. This condition is required to prevent antineutrinos from tunneling into classically inaccessible trajectories below the Earth’s surface and washing away the large asymmetry. As the physical parameters of the Earth do not satisfy this condition, we find that the asymmetry at the surface should only be O ( δ ) . While the asphericity of the Earth may serve as a loophole to our conclusions, we argue that it is still difficult to generate a large asymmetry even in the presence of local terrain. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Colored hard coatings with AlN–TiN multilayer structures

AlN–TiN multilayer structures can be used to extend the color gamut of hard coatings while maintaining good hardness and corrosion resistance. This study used reactive magnetron sputtering on a glass substrate to produce coatings with a microhardness of 19 GPa as well as optical reflectance exceeding 80% and controllable saturation (chroma) for various hues of red, yellow, green, blue, and purple. The authors characterized the complex index of refraction of the TiN films using ellipsometry; the real refractive indices of the AlN films were derived from the reflectance values obtained using photometry. Finally, the colors of the samples were quantified using CIE-1931 chromaticity coordinates in the L*a*b* color space, and the microhardness of the films was measured using a nanoindenter. Simulation results using a multiple-beam-interference recursive method presented good consistency with experimental measurements with regard to the optical reflective spectra of AlN–TiN multilayer thin film samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial atomic layer deposition: Performance of low temperature H{sub 2}O and O{sub 3} oxidant chemistry for flexible electronics encapsulation

Water and oxygen were compared as oxidizing agents for the Al{sub 2}O{sub 3} atomic layer deposition process using spatial atomic layer deposition reactor. The influence of the precursor dose on the deposition rate and refractive index, which was used as a proxy for film density, was measured as a function of residence time, defined as the time which the moving substrate spent within one precursor gas zone. The effect of temperature on the growth characteristics was also measured. The water-based process gave faster deposition rates and higher refractive indices but the ozone process allowed deposition to take place at lower temperatures while still maintaining good film quality. In general, processes based on both oxidation chemistries were able to produce excellent moisture barrier films with water vapor transmission rate levels of 10{sup −4} g/m{sup 2} day measured at 38 °C and 90% of relative humidity on polyethylene naphthalate substrates. However, the best result of <5 × 10{sup −5} was obtained at 100 °C process temperature with water as precursor.

36 MATERIALS SCIENCE↗

Low-temperature sequential pulsed chemical vapor deposition of ternary B{sub x}Ga{sub 1-x}N and B{sub x}In{sub 1-x}N thin film alloys

In this work, the authors have performed sequential pulsed chemical vapor deposition of ternary B{sub x}Ga{sub 1-x}N and B{sub x}In{sub 1-x}N alloys at a growth temperature of 450 °C. Triethylboron, triethylgallium, trimethylindium, and N{sub 2} or N{sub 2}/H{sub 2} plasma have been utilized as boron, gallium, indium, and nitrogen precursors, respectively. The authors have studied the compositional dependence of structural, optical, and morphological properties of B{sub x}Ga{sub 1-x}N and B{sub x}In{sub 1-x}N ternary thin film alloys. Grazing incidence X-ray diffraction measurements showed that boron incorporation in wurtzite lattice of GaN and InN diminishes the crystallinity of B{sub x}Ga{sub 1-x}N and B{sub x}In{sub 1-x}N sample. Refractive index decreased from 2.24 to 1.65 as the B concentration of B{sub x}Ga{sub 1-x}N increased from 35% to 88%. Similarly, refractive index of B{sub x}In{sub 1-x}N changed from 1.98 to 1.74 for increase in B concentration value from 32% to 87%, respectively. Optical transmission band edge values of the B{sub x}Ga{sub 1-x}N and B{sub x}In{sub 1-x}N films shifted to lower wavelengths with increasing boron content, indicating the tunability of energy band gap with alloy composition. Atomic force microscopy measurements revealed an increase in surface roughness with boron concentration of B{sub x}Ga{sub 1-x}N, while an opposite trend was observed for B{sub x}In{sub 1-x}N thin films.

36 MATERIALS SCIENCE↗

Spatial atomic layer deposition of ZnO/TiO{sub 2} nanolaminates

Spatial atomic layer deposition (S-ALD) is a potential high-throughput manufacturing technique offering fast and large scale ultrathin films deposition. Here, an S-ALD system with modular injectors is introduced for fabricating binary oxides and their nanolaminates. By optimizing the deposition conditions, both ZnO and TiO{sub 2} films demonstrate linear growth and desired surface morphology. The as-deposited ZnO film has high carrier mobility, and the TiO{sub 2} film shows suitable optical transmittance and band gap. The ZnO/TiO{sub 2} nanolaminates are fabricated by alternating substrate movement between each S-ALD modular units of ZnO and TiO{sub 2}. The grazing incidence x-ray diffraction spectra of nanolaminates demonstrating the signature peaks are weaker for the same thickness nanolaminates with more bilayers, suggesting tuning nanolaminates from crystalline to amorphous. Optical transmittances of ZnO/TiO{sub 2} laminates are enhanced with the increase of the bilayers' number in the visible range. Refractive indices of nanolaminates increase with the thickness of each bilayer decreasing, which demonstrates the feasibility of obtaining desired refractive indices by controlling the bilayer number. The electronic properties, including mobility, carrier concentration, and conductivity, are also tunable with different bilayers.

42 ENGINEERING↗

Modeling thin layers of analytes on substrates for spectral analysis: use of solid/liquid n and k values to model reflectance spectra

Since solids are only sometimes seen en masse in a pure bulk form, and for liquids other than water almost never, a capability to model reflectance spectra from analytes deposited on various substrates would be highly advantageous. If available, the real, n ( ν ) , and imaginary, k ( ν ) , components of the complex refractive index, n n + i k , can be used to simulate infrared spectra, accounting for reflection, refraction, and absorption phenomena as a function of wavelength. We focus on using the Pacific Northwest National Laboratory (PNNL) derived n / k vectors for solid and liquid analytes deposited as thin layers on different types of substrates including conductors, such as aluminum, and inorganic dielectrics, such as glass. The model is an adaptation of the Monte Carlo ray trace modeling program, TracePro, extended through the use of its macrolanguage. The model is tested using thin films of organic liquids including silicone oil and no. 2 diesel fuel, as well as organic solids such as caffeine and acetaminophen on aluminum and glass. The predicted spectra for the solid films were compared to experimental hemispherical reflectance data measured using a Fourier transform spectrometer with an integrating sphere. The thickness of the calculated layer is a parameter for predicting the (transflectance) spectra and is obtained using the areal density measured from gravimetric methods to generate the thin-layer samples. Comparison of the calculated spectra with experimental hemispherical reflectance data shows excellent agreement, indicating promise for the use of measured n / k data to synthesize reference spectral data. In particular, accounting for the inhomogeneity of the deposits greatly improved the match with experimental data. Finally, the theoretical modeling shows that for thicker layers (ca. 20 to 100 μm) of typical organics possessing moderately strong k values, the longwave infrared features are often saturated and better spectral contrast is obtained from the overtone/combination bands in the shortwave infrared.

42 ENGINEERING↗

Terahertz time-domain spectroscopy imaging of pancreatic ductal adenocarcinoma tissues

Pancreatic ductal adenocarcinoma (PDAC) ranks among the malignancies with the highest fatality and morbidity rates. This is predominantly attributable to an absence of understanding the intricate and diverse microenvironment of the tumor. We use terahertz time-domain spectroscopy (THz-TDS) imaging in transmission geometry to probe ex-vivo the heterogenous microenvironment of the genetically modified murine PDAC tissue that closely resembles the PDAC heterogeneity in human malignancy. We introduced a maximum a-posteriori probability estimation algorithm to objectively the tumor’s heterogenous microenvironment using the average values of refractive index and absorption coefficient within the useable terahertz bandwidth as imaging markers. Furthermore, direct comparison of stained histopathologic images and the refractive index and the absorption coefficient high-resolution, two dimensional maps of the same PDAC samples confirms the high potential of the THz-TDS method for tumor tissue characterization.

absorption↗

An alternative method of changing the pulse duration in a stretcher-compressor pair by changing the gas pressure in the compressor

The relatively narrow bandwidth of neodymium glass requires a much larger stretch ratio of chirped-pulse amplification (CPA) systems. This factor, together with a large incident angle on the gratings, makes glass CPA systems extremely sensitive to the refractive index of the medium in the stretcher-compressor. High sensitivity of the stretcher-compressor pair for hybrid optical parametric chirped-pulse amplification and an Nd:glass laser to the refractive index was demonstrated in air, vacuum, and carbon dioxide, and a pulse duration close to the transform limit was reached. An alternative way to change the pulse duration was proposed. The pulse duration from the best compression of 500 fs to 30 ps was smoothly varied by changing the air pressure from 10 -6 Torr to 1 atm in the compressor and up to 52 ps in carbon dioxide, while the stretcher and compressor remained untouched. Finally, excellent agreement of the measured pulse duration with theoretical calculations was demonstrated.

47 OTHER INSTRUMENTATION↗

Phase-based x-ray scattering—A possible method to detect cancer cells in a very early stage

Purpose: This theoretical work contains a detailed investigation of the potential and sensitivity of phase-based x-ray scattering for cancer detection in biopsies if cancer is in a very early stage of development. Methods: Cancer cells in their early stage of development differ from healthy ones mainly due to their faster growing cell nuclei and the enlargement of their densities. This growth is accompanied by an altered nucleus–plasma relation for the benefit of the cell nuclei, that changes the physical properties especially the index of refraction of the cell and the one of the cell nuclei. Interaction of radiation with matter is known to be highly sensitive to small changes of the index of refraction of matter; therefore a detection of such changes of volume and density of cell nuclei by means of high angular resolved phase-based scattering of x rays might provide a technique to distinguish malignant cells from healthy ones ifthe cell–cell nucleus system is considered as a coherent phase shifting object. Then one can observe from a thin biopsy which represents a monolayer of cells (no multiple scattering) that phase-based x-ray scattering curves from healthy cells differ from those of cancer cells in their early stage of development. Results: Detailed calculations of x-ray scattering patterns from healthy and cancer cell nuclei yield graphs and numbers with which one can distinguish healthy cells from cancer ones, taking into account that both kinds of cells occur in a tissue within a range of size and density. One important result is the role and the influence of the (lateral) coherence width of the radiation on the scattering curves and the sensitivity of phase-based scattering for cancer detection. A major result is that a larger coherence width yields a larger sensitivity for cancer detection. Further import results are calculated limits for critical sizes and densities of cell nuclei in order to attribute the investigated tissue to be healthy or diseased. Conclusions: With this proposed method it should be in principle possible to detect cancer cells in apparently healthy tissues in biopsies and/or in samples of the far border region of abscised or excised tissues. Thus this method could support established methods in diagnostics of cancer-suspicious samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-164: An Investigation of a Low-Cost ‘dry’ Optical-CT Scanning System for 3D Dosimetry

Purpose: To characterize and explore the efficacy of a novel low-cost, lowfluid, broad-beam optical-CT system for 3D-dosimetry in radiochromic Presage dosimeters. Leading current optical-CT systems incorporate expensive glass-based telecentric lens technology, and a fluid bath with substantial amounts of fluid (which introduces an inconvenience factor) to minimize refraction artifacts. Here we introduce a novel system which addresses both these limitations by: (1) the use of Fresnel lenses in a telecentric arrangement, and (2) a ‘solid’ fluid bath which dramatically reduces the amount of fluid required for refractive-index (RI) matching. Materials Methods: A fresnel based telecentric optical-CT system was constructed which expands light from a single red LED source into a nominally parallel beam into which a cubic ‘dry-tank’ is placed. The drytank consists of a solid polyurethane cube (with the same RI as Presage) but containing a cylindrical cavity (11.5cm diameter × 11cm ) into which the dosimeter is placed for imaging. A narrow (1-3mm) gap between the walls of the dosimeter and dry-tank is filled with a fluid of similar RI. This arrangement reduces the amount of RI fluid from about 1000cc to 75cc, yielding substantial practical benefit in convenience and cost. The new system was evaluated in direct comparison against Eclipse planning system from a 4-field parallel-opposed treatmen Results: Gamma calculations of dose from DFOS-dry system versus Eclipse showed 92% and 97% agreement with 4mm/4% and 5mm/5% criteria, respectively, in the central 80% of dose distribution. Reconstructions showed some edge artifacts, as well as some dose underestimation towards the dosimeter edge. Conclusion: The implementation of Fresnel based ‘dry’ optical-CT for 3Ddosimetry would represent an important advance enhancing costeffectiveness and practical viability. The performance of the prototype presented here is not yet comparable to the state-of-the-art, but shows sufficient promise for further investigation to elevate image quality to match gold-standard optical-CT systems. This work was supported by NIH R01CA100835.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Blood Serum by the Method of Refractometry in Antitumor Therapy in Patients with Multiple Myeloma

The serum of patients with multiple myeloma was examined by refractometric methods before and after the course of antitumor therapy. It was found that the amount of protein in the serum of patients with multiple myeloma, determined by the value of the serum refractive index, tended to decrease after the course of treatment. The value of the refractive index of blood serum can be used as an additional criterion for assessing the dynamics of changes in blood-serum properties during antitumor therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refractometric Parameters of Nonlinear Optical Molecular Cocrystals Based on the Aminopyridine Series

Refractive indices of new nonlinear optical materials based on 4-nitrophenol cocrystals with the aminopyridines 2-aminopyridine, 2,6-aminopyridine, and 4-aminopyridine have been studied. The refractive indices of the compounds under study are presented: n = 1.694 (optical microscopy) and 1.605 (Abbe method) for 2-aminopyridine-4-nitrophenol (2AP4N), n = 1.541 (optical microscopy) and 1.589 (Abbe method) for 2,6-diaminopyridine-4-nitrophenol (2,6DAP4N), and n = 1.561 (optical microscopy) and 1.591 (Abbe method) for 4-aminopyridine-4-nitrophenol (4AP4N).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗