Radiometric temperature reference Patent
Development of system with electrical properties which vary with changes in temperature for use with feedback loop in operational amplifier circuit
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development of system with electrical properties which vary with changes in temperature for use with feedback loop in operational amplifier circuit
The Attitude Control System for the IUE spacecraft is described. The basic mission objectives are stated and a sequential discussion of the mission is presented. Desired accuracy for each mission phase is noted and where applicable the onboard control mechanization is shown. Sensors and actuator systems utilized by the control algorithms are described. Finally, onboard software is discussed to a level necessary to understand the prime mission mode operation.
This document is a technical report for use in developing a consensus on what is required to operate a permanent, or indefinite long-term, archive of digital information. It may be useful as a starting point for a similar document addressing the indefinite long-term preservation of non-digital information. This report establishes a common framework of terms and concepts which comprise an Open Archival Information System (OAIS). It allows existing and future archives to be more meaningfully compared and contrasted. It provides a basis for further standardization of within an archival context and it should promote greater vendor awareness of, and support of , archival requirements. Through the process of normal evolution, it is expected that expansion, deletion, or modification to this document may occur. This report is therefore subject to CCSDS document management and change control procedures.
Description of a technique for single-axis control of a model of a highly flexible space station. Active damping of lower frequency flexibility modes is employed. In the control technique, referred to as invariant poles feedback control, feedback gains are adjusted so that the closed-loop system characteristic equation is matched to that of a reference model. Hence closed-loop system poles will not move; they will be invariant (provided that bending frequencies and parameters can be identified accurately). This is accomplished by obtaining the system characteristic equation in closed form; equating respective coefficients between terms of like powers in s in the system and reference model characteristic equations; and solving for the feedback gains. The feedback gains are explicit functions of system plant parameters and the coefficients of the reference model characteristic equation, and are easily programmed for the digital computer.
This paper presents a method for estimating time delay margin for model-reference adaptive control of systems with almost linear structured uncertainty. The bounded linear stability analysis method seeks to represent the conventional model-reference adaptive law by a locally bounded linear approximation within a small time window using the comparison lemma. The locally bounded linear approximation of the combined adaptive system is cast in a form of an input-time-delay differential equation over a small time window. The time delay margin of this system represents a local stability measure and is computed analytically by a matrix measure method, which provides a simple analytical technique for estimating an upper bound of time delay margin. Based on simulation results for a scalar model-reference adaptive control system, both the bounded linear stability method and the matrix measure method are seen to provide a reasonably accurate and yet not too conservative time delay margin estimation.
The Savannah River Site (SRS) is a Department of Energy site which has produced nuclear materials for national defense, research, space, and medical programs since the 1950's. As a by-product of this activity, approximately 37 million gallons of high-level liquid waste containing approximately 292 million curies of radioactivity is stored on an interim basis in 45 underground storage tanks. Originally, 51 tanks were constructed and utilized to support the mission. Four tanks have been closed and taken out of service and two are currently undergoing the closure process. The Liquid Waste System is a highly integrated operation involving safely storing liquid waste in underground storage tanks; removing, treating, and dispositioning the low-level waste fraction in grout; vitrifying the higher activity waste at the Defense Waste Processing Facility; and storing the vitrified waste in stainless steel canisters until permanent disposition. After waste removal and processing, the storage and processing facilities are decontaminated and closed. A Liquid Waste System Plan (hereinafter referred to as the Plan) was developed to integrate and document the activities required to disposition legacy and future High-Level Waste and to remove from service radioactive liquid waste tanks and facilities. It establishes and records a planning basis for waste processing in the liquid waste system through the end of the program mission. The integrated Plan which recognizes the challenges of constrained funding provides a path forward to complete the liquid waste mission within all regulatory and legal requirements. The overarching objective of the Plan is to meet all Federal Facility Agreement and Site Treatment Plan regulatory commitments on or ahead of schedule while preserving as much life cycle acceleration as possible through incorporation of numerous cost savings initiatives, elimination of non-essential scope, and deferral of other scope not on the critical path to compliance. There is currently a premium on processing and storage space in the radioactive liquid waste tank system. To enable continuation of risk reduction initiatives, the Plan establishes a processing strategy that provides tank space required to meet, or minimizes the impacts to meeting, programmatic objectives. The Plan also addresses perturbations in funding and schedule impacts. (authors)
Highlights: • Relative Fisher information in both r and p spaces is calculated analytically. • In case of central potentials, circular state of a given l, is selected as reference. • In hydrogenic system IR provides better result than that of I. • In case of oscillator potentials IR comments about change of bond strength with n{sub r}. - Abstract: Relative Fisher information (IR) was pursued for 1D quantum harmonic oscillator (QHO), 3D isotropic QHO, hydrogen atom and pseudoharmonic potential (PHP) in both r and p spaces. In 1D case, the n=0 state is chosen as reference, whereas for a central potential, the respective circular (corresponding to lowest radial quantum number n{sub r}) state of a given l quantum number, is selected. Starting from their exact wave functions, expressions of IR in both r and p spaces are obtained in closed analytical forms in all these systems. For the 1D QHO, IR in r,p spaces increases linearly with n. For 3D QHO and PHP, it varies with single power of n{sub r} in both spaces. But, in H atom they depend on both principal (n) and azimuthal (l) quantum numbers. However, at a fixed l, IR initially advances with rise of n and then falls off; also for a given n, it always decreases with l.
The James Webb Space Telescope science instruments are in the final stages of being integrated into the Integrated Science Instrument Module (ISIM) element. Each instrument is tied into a common coordinate system through mechanical references that are used for optical alignment and metrology within ISIM after element-level assembly. In addition, a set of ground support equipment (GSE) consisting of large, precisely calibrated, ambient, and cryogenic structures are used as alignment references and gauges during various phases of integration and test (I&T). This GSE, the flight instruments, and ISIM structure feature different types of complimentary metrology targeting. These GSE targets are used to establish and track six degrees of freedom instrument alignment during I&T in the vehicle coordinate system (VCS). This paper describes the optomechanical metrology conducted during science instrument integration and alignment in the Spacecraft Systems Development and Integration Facility (SSDIF) cleanroom at NASA Goddard Space Flight Center (GSFC). The measurement of each instrument's ambient entrance pupil location in the telescope coordinate system is discussed. The construction of the database of target locations and the development of metrology uncertainties is also discussed.
This report contributes to the body of literature by reviewing key challenges for competitive wholesale electricity market design in deeply decarbonized power systems and establishing potential solutions and associated research needs. We provide a long-term perspective on ways in which competitive wholesale electricity markets can evolve to ensure that they still operate efficiently throughout the transition to a deeply decarbonized future. In this report, we use the term “deep decarbonization” to refer broadly to systems that generate nearly all their electricity from zero-carbon or carbon-neutral resources, while recognizing that there are many potential configurations of such systems. We also stress that many of these issues will arise to varying degrees as systems move toward full decarbonization, even if they are not truly 100% carbon-free.
Design criteria and technology requirements for a system of radar reference devices to be fixed to the surfaces of the inner planets are discussed. Offshoot applications include the use of radar corner reflectors as landing beacons on the planetary surfaces and some deep space applications that may yield a greatly enhanced knowledge of the gravitational and electromagnetic structure of the solar system. Passive retroreflectors with dimensions of about 4 meters and weighing about 10 kg are feasible for use with orbiting radar at Venus and Mars. Earth-based observation of passive reflectors, however, would require very large and complex structures to be delivered to the surfaces. For Earth-based measurements, surface transponders offer a distinct advantage in accuracy over passive reflectors. A conceptual design for a high temperature transponder is presented. The design appears feasible for the Venus surface using existing electronics and power components.
A systematic review and harmonization of life cycle assessment (LCA) literature of utility-scale wind power systems was performed to determine the causes of and, where possible, reduce variability in estimates of life cycle greenhouse gas (GHG) emissions. Screening of approximately 240 LCAs of onshore and offshore systems yielded 72 references meeting minimum thresholds for quality, transparency, and relevance. Of those, 49 references provided 126 estimates of life cycle GHG emissions. Published estimates ranged from 1.7 to 81 grams CO{sub 2}-equivalent per kilowatt-hour (g CO{sub 2}-eq/kWh), with median and interquartile range (IQR) both at 12 g CO{sub 2}-eq/kWh. After adjusting the published estimates to use consistent gross system boundaries and values for several important system parameters, the total range was reduced by 47% to 3.0 to 45 g CO{sub 2}-eq/kWh and the IQR was reduced by 14% to 10 g CO{sub 2}-eq/kWh, while the median remained relatively constant (11 g CO{sub 2}-eq/kWh). Harmonization of capacity factor resulted in the largest reduction in variability in life cycle GHG emission estimates. This study concludes that the large number of previously published life cycle GHG emission estimates of wind power systems and their tight distribution suggest that new process-based LCAs of similar wind turbine technologies are unlikely to differ greatly. However, additional consequential LCAs would enhance the understanding of true life cycle GHG emissions of wind power (e.g., changes to other generators operations when wind electricity is added to the grid), although even those are unlikely to fundamentally change the comparison of wind to other electricity generation sources.
Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.
VLBI measurements of extragalactic radio sources are utilized to develop a definition system for local inertial reference frames. Significant astrometric errors are identified and minimized by means of a parameter-estimation technique. A reference frame is measured for 30 min to observe the radio emission of the object to be located in the frame as well as the emission from about five additional sources which define the frame. Because the structures of the objects are unknown and tropospheric fluctuations exist, limiting errors exist for both single-epoch position determination and epoch-to-epoch differential position measurements. Data are presented regarding relativistic gravitational deflection by Jupiter which show that the local reference frame is stable at 240 microarcseconds over 12 days.
Starting with an assumed ideal network having perfect clocks at every node and known fixed transmission delays between nodes, the effects of adding tolerances to both transmission delays and nodal clocks is described. The advantages of controlling tolerances on time rather than frequency are discussed. Then a concept is presented for maintaining these tolerances on time throughout the network. This concept, called time reference distribution, is a systematic technique for distributing time reference to all nodes of the network. It is reliable, survivable and possesses many other desirable characteristics. Some of its features such as an excellent self monitoring capability will be pointed out. Some preliminary estimates of the accuracy that might be expected are developed and there is a brief discussion of the impact upon communication system costs. Time reference distribution is a concept that appears very attractive. It has not had experimental evaluation and has not yet been endorsed for use in any communication network.
In a coordinate system moving with the plasma and random magnetic fields of a wind that blows with constant velocity in the direction of the guiding field, transport of energetic particles is described by a Boltzmann equation which is similar to the one that describes unconvected transport. Although this formulation is mathematically identical to that developed by Luhmann, which refers to the system where the guiding field is static, there are both practical and fundamental reasons to adopt the new approach. It leads to first-order approximate transport equations which are similar to those that apply in the absence of convection. However, these equations are more general than Parker's description of diffusion and convection, for they describe the coherent modes of transport that appear when the mean free path is large compared to the scale length for spatial variations of the guiding field, and they are valid for arbitrary wind velocity. The latter characteristic opens up new possibilities for analyzing particle transport in relativistic flows seen in some astronomical objects.
The variations in feedstock characteristics, such as moisture and particle size distribution, lead to an inconsistent flow of feedstock from the biomass pre-processing system to the reactor in-feed system. These inconsistencies result in low on-stream times at the reactor in-feed equipment. This research develops an optimal process control method for a biomass pre-processing system comprised of milling and densification operations to provide the consistent flow of feedstock to a reactor's throat. This method uses a mixed-integer optimization model to identify optimal bale sequencing, equipment in-feed rate, and buffer location and size in the biomass pre-processing system. This method, referred to as the hybrid process control (HPC), aims to maximize throughput over time. We compare HPC with a baseline feed forward process control. Our case study based on switchgrass finds that HPC reduces the variation of a reactor's feeding rate by up to 100% without increasing the operating cost of the biomass pre-processing system for biomass with moisture ranging from 10 to 25%. Additionally, HPC reduces the cost of processing biomass by 0.36%–2.22%, and reduces processing time by 0.35%-2.24%. Furthermore, a biorefinery can adapt HPC to achieve its design capacity.
The HEAO-B Gas Control System consists of a high pressure gas storage supply together with distribution and regulation assemblies and their associated electronics for management of gas required for HEAO-B X-ray counter experiments. The Gas Control System replenishes a gas mixture (82 percent argon, 12.3 percent carbon dioxide, 5.7 percent xenon) in the counter volumes which is lost by: diffusion through controlled leakage plugs, diffusion through counter windows, and consumption resulting from periodic purges. The gas density in each counter volume is maintained constant to within 0.25 percent by comparison with a sealed reference volume. The system is fully redundant, capable of operating at atmospheric pressure as well as in a vacuum, contains interlocks which shut down gas flow in the event of either leakage or excessive pressure, and is able to shut down counter high voltage if counter pressure is abnormally low. The system is electronically controlled by ground command and self-sustaining in orbit for a period of at least one year.
Drought is a water deficit state caused by large-scale climate change that cannot be avoided by a water resource management system. Water scarcity refers to the unsustainable utilization of water resources over a long time, which is the result of water management policies. However, water deficits caused by drought and water scarcity often occur simultaneously and are indistinguishable. This study proposes a model-based simulation framework that can quantitatively distinguish natural factors (drought) from human factors (water scarcity) in a hydrological system. The simulation was applied to the Zhangweinan Canal Basin, based on the runoff sequences from 1950 to 2004. The results show that the runoff curve number, soil depth, soil available water, soil evaporation compensation coefficient, base runoff α coefficient and the maximum canopy interception have the highest sensitivity to runoff, and that the calibrated and validated SWAT model can effectively simulate the runoff process in the Zhangweinan Canal Basin and similar areas. Abrupt changes in human activities in 1975 and water scarcity led to the disappearance of the summer peak runoff period in both wet and dry years. Human factors are the main reason for the change in the hydrological system in the study area; the runoff loss caused by human factors is four times that caused by natural factors according to the proposed variable threshold. This study proposes a model-based simulation framework that can help water resource managers to distinguish the effects of drought and water scarcity in water-stressed areas and adjust management accordingly.