Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,189 records · Page 66

Update on friction bonding of monolithic U-Mo fuel plates

Friction Bonding (FB), formerly referred to as Friction Stir Welding, is an alternative plate fabrication technique to encapsulate monolithic U-Mo fuel foils inside 6061-T6 aluminum alloy cladding. Over the past year, significant progress has been made in the area of FB, including improvements in tool material, tool design, process parameters, cooling capability and capacity and modeling, all of which improve and enhance the quality of fabricated fuel plates, reproducibility of the fabrication process and bond quality of the fuel plates. Details of this progress and how it relates to the observed improvements and enhancements are discussed. In addition, details on how these improvements have been implemented into the last two RERTR mini-plate irradiation campaigns are also discussed. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NASA-Modified Precipitation Products to Improve EPA Nonpoint Source Water Quality Modeling for the Chesapeake Bay

The Environmental Protection Agency (EPA) has estimated that over 20,000 water bodies within the United States do not meet water quality standards. Ninety percent of the impairments are typically caused by nonpoint sources. One of the regulations in the Clean Water Act of 1972 requires States to monitor the Total Maximum Daily Load (TMDL), or the amount of pollution that can be carried by a water body before it is determined to be "polluted", for any watershed in the U.S.. In response to this mandate, the EPA developed Better Assessment Science Integrating Nonpoint Sources (BASINS) as a Decision Support Tool (DST) for assessing pollution and to guide the decision making process for improving water quality. One of the models in BASINS, the Hydrological Simulation Program -- Fortran (HSPF), computes daily stream flow rates and pollutant concentration at each basin outlet. By design, precipitation and other meteorological data from weather stations serve as standard model input. In practice, these stations may be unable to capture the spatial heterogeneity of precipitation events especially if they are few and far between. An attempt was made to resolve this issue by substituting station data with NASA modified/NOAA precipitation data. Using these data within HSPF, stream flow was calculated for seven watersheds in the Chesapeake Bay Basin during low flow periods, convective storm periods, and annual flows. In almost every case, the modeling performance of HSPF increased when using the NASA-modified precipitation data, resulting in better stream flow statistics and, ultimately, in improved water quality assessment.

Nigro, Joseph↗

Many-Body Majorana Braiding without an Exponential Hilbert Space

Qubits built out of Majorana zero modes constitute the primary path toward topologically protected quantum computing. Simulating the braiding process of multiple Majorana zero modes corresponds to the quantum dynamics of a superconducting many-body system. It is crucial to study the Majorana dynamics both in the presence of all other quasiparticles and for reasonably large system sizes. We present a method to calculate arbitrary many-body wave functions as well as their expectation values, correlators, and overlaps from time evolved single-particle states of a superconductor, allowing for significantly larger system sizes. We calculate the fidelity, transition probabilities, and joint parities of Majorana pairs to track the quality of the braiding process. Here, we show how the braiding success depends on the speed of the braid. Moreover, we demonstrate the topological CNOT two-qubit gate as an example of two-qubit entanglement. Our Letter opens the path to test and analyze the many theoretical implementations of Majorana qubits. Moreover, this method can be used to study the dynamics of any noninteracting superconductor.

Majorana bound states↗

Vision Systems Illuminate Industrial Processes

When NASA designs a spacecraft to undertake a new mission, innovation does not stop after the design phase. In many cases, these spacecraft are firsts of their kind, requiring not only remarkable imagination and expertise in their conception but new technologies and methods for their manufacture. In the realm of manufacturing, NASA has from necessity worked on the cutting-edge, seeking new techniques and materials for creating unprecedented structures, as well as capabilities for reducing the cost and increasing the efficiency of existing manufacturing technologies. From friction stir welding enhancements (Spinoff 2009) to thermoset composites (Spinoff 2011), NASA s innovations in manufacturing have often transferred to the public in ways that enable the expansion of the Nation s industrial productivity. NASA has long pursued ways of improving upon and ensuring quality results from manufacturing processes ranging from arc welding to thermal coating applications. But many of these processes generate blinding light (hence the need for special eyewear during welding) that obscures the process while it is happening, making it difficult to monitor and evaluate. In the 1980s, NASA partnered with a company to develop technology to address this issue. Today, that collaboration has spawned multiple commercial products that not only support effective manufacturing for private industry but also may support NASA in the use of an exciting, rapidly growing field of manufacturing ideal for long-duration space missions.

Source record↗

WE-AB-BRA-07: Operating Room Quality Assurance (ORQA) for Spine Surgery Using Known-Component 3D-2D Image Registration

Purpose: Intraoperative x-ray radiography/fluoroscopy is commonly used to qualitatively assess delivery of surgical devices (e.g., spine pedicle screws) but can fail to reliably detect suboptimal placement (e.g., breach of adjacent critical structures). We present a method wherein prior knowledge of the patient and surgical components is leveraged to match preoperative CT and intraoperative radiographs for quantitative assessment of 3D pose. The method presents a new means of operating room quantitative quality assurance (ORQA) that could improve quality and safety, and reduce the frequency of revision surgeries. Methods: The algorithm (known-component registration, KC-Reg) uses patient-specific preoperative CT and parametrically defined surgical component models within a robust 3D-2D registration method to iteratively optimize gradient similarity using the covariance matrix adaptation evolution strategy. Advances from previous work address key challenges to clinical translation: i) absolving the need for offline geometric calibration of the C-arm; and ii) solving multiple component bodies simultaneously, thereby allowing QA in a single step (e.g., spinal construct with 4–20 screws), rather than sequential QA of each component. Performance was tested in a spine phantom with 10 pedicle screws, and first results from clinical studies are reported. Results: Phantom experiments demonstrated median target registration error (TRE) of (1.0±0.3) mm at the screw tip and (0.7°±0.4°) in angulation. The simultaneous multi-body registration approach improved TRE from the previous (sequential) method by 42%, reduced outliers, and fits into the natural workflow. Initial application of KC-Reg in clinical data shows TRE of (2.5±4.5) mm and (4.7°±0.5°). Conclusion: The KC-Reg algorithm offers a potentially valuable method for quantitative QA of the surgical product, using radiographic systems that are already within the surgical arsenal. For spine surgery, the method offers a near-real-time independent check on the quality of surgical product, facilitating immediate revision if necessary and potentially avoiding postoperative morbidity and/or revision surgery. Gerhard Kleinszig and Sebastian Vogt are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Kinetic modelling of an environmentally friendly carbamazepine synthesis via urea and iminostilbene in batch and continuous processes

Accurate kinetic models for reaction systems allow for improved process understanding and greater quality control, which is particularly beneficial as the pharmaceutical industry shifts from batch to continuous manufacturing (CM). In this work, a first principles kinetic model has been developed for the synthesis of carbamazepine (CBZ) from iminostilbene and urea, starting in a batch reactor and subsequently in a continuous flow reactor. An eco-friendly reaction pathway using urea was selected to avoid the toxic reagents that are typically used for synthesis of CBZ. The kinetic parameters determined from batch reactions were utilized in a MATLAB based kinetic model to simulate the yield for the continuous process. Overall, good agreement between the model prediction and corresponding experimental values was observed for the batch and continuous reaction systems within the full factorial design space. However, the model slightly overpredicted the yield of the continuous reaction system for higher conversion values (>60%) since it did not account for the reverse reaction that can occur at the studied reaction conditions. Here, the use of broken order kinetics was compared with whole number orders, and it was determined that the whole number orders resulted in better agreement at all conversion values for the continuous system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Lignite Quality Variables: A Practical Approach with Sequential Gaussian Simulation

Traditional mine planning methods based on block models built with interpolation techniques such as inverse distance and kriging are inadequate in assessing the uncertainty associated with the technological parameters of coal deposit variables, which are modeled for short-range mine planning because of smoothing effects. However, simulation methods aim at reproducing in situ quality variability and spatial continuity of the attributes of interest. This study outlines the spatial distribution and uncertainty of quality variables at the Tufanbeyli (Adana-Turkey) lignite deposit using a probabilistic approach. A practical approach was based on geostatistical sequential Gaussian simulation (SGS) used to yield a series of conditional images characterized by equally probable spatial distributions of the quality parameters across the deposit. Post processing of many simulations allowed the mapping of maximum/minimum limits for quality values and provided a model for the uncertainty in the spatial distribution of the quality parameters. SGS was validated by a number of tests such as descriptive statistics, histogram, and variogram reproductions. The advantages of SGS were practically illustrated through the case study. The simulated models can be incorporated into mine planning and scheduling.

01 COAL, LIGNITE, AND PEAT↗

Automatic Waveform Quality Control for Surface Waves Using Machine Learning

Surface-wave seismograms are widely used by researchers to study Earth’s interior and earthquakes. To extract information reliably and robustly from a suite of surface waveforms, the signals require quality control screening to reduce artifacts from signal complexity and noise. This process has usually been completed by human experts labeling each waveform visually, which is time consuming and tedious for large data sets. We explore automated approaches to improve the efficiency of waveform quality control processing by investigating logistic regression, support vector machines, K-nearest neighbors, random forests (RF), and artificial neural networks (ANN) algorithms. To speed up signal quality assessment, we trained these five machine learning (ML) methods using nearly 400,000 human-labeled waveforms. The ANN and RF models outperformed other algorithms and achieved a test accuracy of 92%. We evaluated these two best-performing models using seismic events from geographic regions not used for training. The results show that the two trained models agree with labels from human analysts but required only 0.4% of the time. Although the original (human) quality assignments assessed general waveform signal-to-noise, the ANN or RF labels can help facilitate detailed waveform analysis. Our investigations demonstrate the capability of the automated processing using these two ML models to reduce outliers in surface-wave-related measurements without human quality control screening.

58 GEOSCIENCES↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

Reduction of a grid moire pattern by integrating a carbon-interspaced high precision x-ray grid with a digital radiographic detector

The stationary grid commonly used with a digital x-ray detector causes a moire interference pattern due to the inadequate sampling of the grid shadows by the detector pixels. There are limitations with the previous methods used to remove the moire such as imperfect electromagnetic interference shielding and the loss of image information. A new method is proposed for removing the moire pattern by integrating a carbon-interspaced high precision x-ray grid with high grid line uniformity with the detector for frequency matching. The grid was aligned to the detector by translating and rotating the x-ray grid with respect to the detector using microcontrolled alignment mechanism. The gap between the grid and the detector surface was adjusted with micrometer precision to precisely match the projected grid line pitch to the detector pixel pitch. Considering the magnification of the grid shadows on the detector plane, the grids were manufactured such that the grid line frequency was slightly higher than the detector sampling frequency. This study examined the factors that affect the moire pattern, particularly the line frequency and displacement. The frequency of the moire pattern was found to be sensitive to the angular displacement of the grid with respect to the detector while the horizontal translation alters the phase but not the moire frequency. The frequency of the moire pattern also decreased with decreasing difference in frequency between the grid and the detector, and a moire-free image was produced after complete matching for a given source to detector distance. The image quality factors including the contrast, signal-to-noise ratio and uniformity in the images with and without the moire pattern were investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179

Purpose: Commercial CT-based image-guided radiotherapy (IGRT) systems allow widespread management of geometric variations in patient setup and internal organ motion. This document provides consensus recommendations for quality assurance protocols that ensure patient safety and patient treatment fidelity for such systems. Methods: The AAPM TG-179 reviews clinical implementation and quality assurance aspects for commercially available CT-based IGRT, each with their unique capabilities and underlying physics. The systems described are kilovolt and megavolt cone-beam CT, fan-beam MVCT, and CT-on-rails. A summary of the literature describing current clinical usage is also provided. Results: This report proposes a generic quality assurance program for CT-based IGRT systems in an effort to provide a vendor-independent program for clinical users. Published data from long-term, repeated quality control tests form the basis of the proposed test frequencies and tolerances.Conclusion: A program for quality control of CT-based image-guidance systems has been produced, with focus on geometry, image quality, image dose, system operation, and safety. Agreement and clarification with respect to reports from the AAPM TG-101, TG-104, TG-142, and TG-148 has been addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and Pre-treatment of LLW in Turkey - 12572

Pre-treatment of radioactive waste is the first step in waste management program that occurs after waste generation from various applications in Turkey. Pre-treatment and characterization practices are carried out in Radioactive Waste Management Unit (RWMU) at Cekmece Nuclear Research and Training Center (CNRTC) in Istanbul. This facility has been assigned to take all low-level radioactive wastes generated by nuclear applications in Turkey. The wastes are generated from research and nuclear applications mainly in medicine, biology, agriculture, quality control in metal processing and construction industries. These wastes are classified as low- level radioactive wastes. Pre-treatment practices cover several steps. In this paper, main steps of pre-treatment and characterization are presented. Basically these are; collection, segregation, chemical adjustment, size reduction and decontamination operations. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precipitable Water Vapor Characterization In The Gulf Of Cadiz Region (Southwestern Spain) Based On Sun Photometer, GPS And Radiosonde Data

Column integrated water vapor (IWV) data in the Gulf of Cádiz area (Southwestern Spain) are analyzed during the period 2001 to 2005 with two aims: 1) to establish the climatology over this area using three different techniques, such as Sun-Photometer (SP), Global Position System (GPS) and Radiosondes, and 2) to take advantage of this comparative process to assess the quality of radiometric IWV data collected at the RIMA-AERONET station. The 5 years of climatological series gives a mean value of about 2 cm (STD=0.72) and a clear seasonal behavior as a general feature, with the highest values in summer and the lowest in winter. In the multi-annual monthly means basis, the highest values are reached in August-September, with a mean value of 2.5-2.6 cm, whereas the lowest are obtained in January-February, with an average of 1.4-24 1.5. However the most relevant results for this area is the observed local minimum in July, occurring during the maximum of desert dust intrusions in the southern Iberian Peninsula. A comparison process allows us to evaluate the agreement of IWV data sets between these three different techniques at different temporal scales because of different time sampling. On a daily basis and taking GPS as the reference value we have a bias or difference between Radiosonde and GPS measurements for the entire data base of 0.07 cm (relative bias of 3%) and RMSE of 0.33. For SP-GPS we have a bias of 0.14 cm (about 7%) and RMSE of 0.37. On a monthly basis the differences between Radiosonde and GPS values varies from summer with 2% to winter with -8% and between SP and GPS values from 3% in summer to -14% in winter. The observed bias between GPS and SP varies during each SP operational period, with lower values at the beginning of the measurements and increasing until the end of its measurement term and with the bias values being quite dependent on each individual SP. The observed differences highlight the importance of drift in each Sun-Photometer, because of filter aging or other calibration problems. Hence the comparison with GPS appears to be a powerful tool to assess the quality of Sun-Photometer for IWV retrieval.

54 ENVIRONMENTAL SCIENCES↗

A phantom for testing of 4D-CT for radiotherapy of small lesions

Purpose: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. Methods: The phantom of 'see-saw' design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET/CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. Results: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. Conclusions: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter/intervendor testing of commercial 4D-CT systems. When imaging objects with large amplitudes, the completeness criterion described here indicates the number of phase bins required to prevent missing data in MIPs and AIPs. This is most relevant for small lesions undergoing large motions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-B-304-01: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-02: Quantitative FMEA of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗